Wippermann, Dominik; Pieper, Andrea; Zimmermann, Tristan; Klein, Ole; Pröfrock, Daniel: Trace metal distribution for water samples of the cruise AT004 [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.973612 (dataset in review)

Show MapGoogle Earth

Abstract:
Offshore wind energy is a steadily growing sector contributing to the worldwide energy production. The impact of these offshore constructions on the marine environment, however, remains unclear in many aspects. In fact, little is known about potential emissions from corrosion protection systems such as organic coatings or galvanic anodes composed of Al and Zn alloys, used to protect offshore structures. In order to assess potential chemical emissions from offshore wind farms and their impact on the marine environment water and sediment samples were taken in and around offshore wind farms of the German Bight between 12.04.2021 and 23.04.2021 within the context of the Hereon-BSH project OffChEm II. The water samples were taken in metal-free GO-FLO sampling bottles, filtered over <0.45 µm polycarbonate filters into pre-cleaned LDPE bottles and acidified with nitric acid. The filtrates were then measured for their (trace) metal concentrations with ICP-MS/MS coupled online to a seaFAST preconcentration and matrix removal system.
Related to:
Ebeling, Anna; Zimmermann, Tristan; Klein, Ole; Irrgeher, Johanna; Pröfrock, Daniel (2022): Analysis of Seventeen Certified Water Reference Materials for Trace and Technology‐Critical Elements. Geostandards and Geoanalytical Research, 46(2), 351-378, https://doi.org/10.1111/ggr.12422
Petrauskas, Catharina; Wippermann, Dominik; Zimmermann, Tristan; Klein, Ole; Pröfrock, Daniel: Metal distribution for sediment samples of the cruise AT004 [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.973656
Wippermann, Dominik; Zimmermann, Tristan; Klein, Ole; Pröfrock, Daniel: Grain size distribution for sediment samples of the cruise AT004 [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.973616
Project(s):
Coverage:
Median Latitude: 54.587272 * Median Longitude: 6.596240 * South-bound Latitude: 53.523016 * West-bound Longitude: 3.343307 * North-bound Latitude: 55.921855 * East-bound Longitude: 8.582320
Date/Time Start: 2021-04-13T19:42:00 * Date/Time End: 2021-04-20T09:19:00
Minimum DEPTH, water: 10 m * Maximum DEPTH, water: 10 m
Event(s):
AT004_Stat_S_002_WS (AT004_Stat_S_002) * Latitude: 54.066585 * Longitude: 8.127276 * Date/Time: 2021-04-13T19:42:00 * Elevation: -20.5 m * Location: German Bight * Campaign: Atair004 (AT004) * Basis: Atair * Method/Device: Go-Flo bottles (GOFLO)
AT004_Stat_S_003_WS (AT004_Stat_S_003) * Latitude: 54.073998 * Longitude: 7.175509 * Date/Time: 2021-04-14T06:33:00 * Elevation: -35.0 m * Location: German Bight * Campaign: Atair004 (AT004) * Basis: Atair * Method/Device: Go-Flo bottles (GOFLO)
AT004_Stat_S_004_WS (AT004_Stat_S_004) * Latitude: 54.058142 * Longitude: 7.041611 * Date/Time: 2021-04-14T07:59:00 * Elevation: -35.0 m * Location: German Bight * Campaign: Atair004 (AT004) * Basis: Atair * Method/Device: Go-Flo bottles (GOFLO)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventWippermann, Dominik
2Sample code/labelSample labelWippermann, Dominik
3International Generic Sample NumberIGSNWippermann, Dominik
4Optional event labelEvent 2Wippermann, Dominik
5Station labelStationWippermann, Dominik
6Elevation of eventElevationmWippermann, Dominik
7Latitude of eventLatitudeWippermann, Dominik
8Longitude of eventLongitudeWippermann, Dominik
9Date/Time of eventDate/TimeWippermann, Dominik
10Method/Device of eventMethod/DeviceWippermann, Dominik
11DEPTH, waterDepth watermWippermann, DominikGeocode
12AluminiumAlng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 68 ng/l, limit of quantification: 196 ng/l
13Aluminium, uncertaintyAl unc±Wippermann, Dominik
14TitaniumTing/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 2.4 ng/l, limit of quantification: 6 ng/l
15Titanium, uncertaintyTi unc±Wippermann, Dominik
16VanadiumVng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.8 ng/l, limit of quantification: 2.6 ng/l
17Vanadium, uncertaintyV unc±Wippermann, Dominik
18ManganeseMnng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 12 ng/l, limit of quantification: 38 ng/l
19Manganese, uncertaintyMn unc±Wippermann, Dominik
20IronFeng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 225 ng/l, limit of quantification: 681 ng/l
21Iron, uncertaintyFe unc±Wippermann, Dominik
22CobaltCong/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.6 ng/l, limit of quantification: 1.6 ng/l
23Cobalt, uncertaintyCo unc±Wippermann, Dominik
24ErbiumErng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.004 ng/l, limit of quantification: 0.013 ng/l
25Erbium, uncertaintyEr unc±Wippermann, Dominik
26ThuliumTmng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.004 ng/l, limit of quantification: 0.014 ng/l
27Thulium, uncertaintyTm unc±Wippermann, Dominik
28YtterbiumYbng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.009 ng/l, limit of quantification: 0.029 ng/l
29Ytterbium, uncertaintyYb unc±Wippermann, Dominik
30LutetiumLung/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.005 ng/l, limit of quantification: 0.018 ng/l
31Lutetium, uncertaintyLu unc±Wippermann, Dominik
32TungstenWng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.31 ng/l, limit of quantification: 0.7 ng/l
33Tungsten, uncertaintyW unc±Wippermann, Dominik
34LeadPbng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 1.4 ng/l, limit of quantification: 4.3 ng/l
35Lead, uncertaintyPb unc±Wippermann, Dominik
36SamariumSmng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.005 ng/l, limit of quantification: 0.016 ng/l
37Samarium, uncertaintySm unc±Wippermann, Dominik
38EuropiumEung/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.005 ng/l, limit of quantification: 0.017 ng/l
39Europium, uncertaintyEu unc±Wippermann, Dominik
40GadoliniumGdng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.18 ng/l, limit of quantification: 0.6 ng/l
41Gadolinium, uncertaintyGd unc±Wippermann, Dominik
42TerbiumTbng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.0035 ng/l, limit of quantification: 0.011 ng/l
43Terbium, uncertaintyTb unc±Wippermann, Dominik
44DysprosiumDyng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.008 ng/l, limit of quantification: 0.026 ng/l
45Dysprosium, uncertaintyDy unc±Wippermann, Dominik
46HolmiumHong/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.0033 ng/l, limit of quantification: 0.01 ng/l
47Holmium, uncertaintyHo unc±Wippermann, Dominik
48IndiumInng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.008 ng/l, limit of quantification: 0.027 ng/l
49Indium, uncertaintyIn unc±Wippermann, Dominik
50TinSnng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 1.2 ng/l, limit of quantification: 3.5 ng/l
51Tin, uncertaintySn unc±Wippermann, Dominik
52LanthanumLang/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.17 ng/l, limit of quantification: 0.6 ng/l
53Lanthanum, uncertaintyLa unc±Wippermann, Dominik
54CeriumCeng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.16 ng/l, limit of quantification: 0.5 ng/l
55Cerium, uncertaintyCe unc±Wippermann, Dominik
56PraseodymiumPrng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.008 ng/l, limit of quantification: 0.024 ng/l
57Praseodymium, uncertaintyPr unc±Wippermann, Dominik
58NeodymiumNdng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.018 ng/l, limit of quantification: 0.05 ng/l
59Neodymium, uncertaintyNd unc±Wippermann, Dominik
60NickelNing/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 33 ng/l, limit of quantification: 109 ng/l
61Nickel, uncertaintyNi unc±Wippermann, Dominik
62CopperCung/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 23 ng/l, limit of quantification: 74 ng/l
63Copper, uncertaintyCu unc±Wippermann, Dominik
64ZincZnng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 115 ng/l, limit of quantification: 379 ng/l
65Zinc, uncertaintyZn unc±Wippermann, Dominik
66GalliumGang/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.4 ng/l, limit of quantification: 1.2 ng/l
67Gallium, uncertaintyGa unc±Wippermann, Dominik
68YttriumYng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.06 ng/l, limit of quantification: 0.19 ng/l
69Yttrium, uncertaintyY unc±Wippermann, Dominik
70CadmiumCdng/lWippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, limit of detection: 0.14 ng/l, limit of quantification: 0.5 ng/l
71Cadmium, uncertaintyCd unc±Wippermann, Dominik
72Gadolinium anomalyGd/Gd*Wippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, quality flag: 0
73Gadolinium anomaly, uncertaintyGd/Gd* unc±Wippermann, Dominik
74Quality assessmentQuality assessmentWippermann, Dominikof Gadolinium anomaly
75Gadolinium, anthropogenicGd anthrop%Wippermann, DominikElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, <0.45 µm filtrate, quality flag: 0
76Gadolinium, anthropogenic, uncertaintyGd anthrop unc±Wippermann, Dominik
77Quality assessmentQuality assessmentWippermann, Dominikof Gadolinium anthropogenic amount
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
3100 data points