Petrauskas, Catharina; Wippermann, Dominik; Zimmermann, Tristan; Klein, Ole; Pröfrock, Daniel (2024): Metal distribution for sediment samples of the cruise AT004 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.973656
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2024-11-29 • DOI registered: 2024-12-28
Abstract:
Offshore wind energy is a steadily growing sector contributing to the worldwide energy production. The impact of these offshore constructions on the marine environment, however, remains unclear in many aspects. In fact, little is known about potential emissions from corrosion protection systems such as organic coatings or galvanic anodes composed of Al and Zn alloys, used to protect offshore structures. In order to assess potential chemical emissions from offshore wind farms and their impact on the marine environment water and sediment were taken in and around offshore wind farms of the German Bight between 12.04.2021 and 23.04.2021 within the context of the Hereon-BSH project OffChEm II. The surface sediment samples were taken by a box grab, homogenized, freeze-dried and wet-sieved to gain the <20 µm grain size fraction. The <20 µm grain size fraction was acid digested and measured by ICP-MS/MS for their (trace) metal mass fractions.
Related to:
Ebeling, Anna; Wippermann, Dominik; Zimmermann, Tristan; Klein, Ole; Kirchgeorg, Torben; Weinberg, Ingo; Hasenbein, Simone; Plaß, Anna; Pröfrock, Daniel (2023): Investigation of potential metal emissions from galvanic anodes in offshore wind farms into North Sea sediments. Marine Pollution Bulletin, 194, 115396, https://doi.org/10.1016/j.marpolbul.2023.115396
Hasenbein, Simone; Zimmermann, Tristan; Klein, Ole; de la Granda Grandoso, Francisco; Köllner, Manuela; Schneehorst, Anja (2024): Oceanographic parameters for the sample stations of the cruise AT004 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.973582
Klein, Ole; Zimmermann, Tristan; Pröfrock, Daniel (2021): Improved determination of technologically critical elements in sediment digests by ICP-MS/MS using N2O as a reaction gas. Journal of Analytical Atomic Spectrometry, 36(7), 1524-1532, https://doi.org/10.1039/D1JA00088H
Wippermann, Dominik; Pieper, Andrea; Zimmermann, Tristan; Klein, Ole; Pröfrock, Daniel: Trace metal distribution for water samples of the cruise AT004 [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.973612
Wippermann, Dominik; Zimmermann, Tristan; Klein, Ole; Pröfrock, Daniel (2024): Grain size distribution for sediment samples of the cruise AT004 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.973616
Zimmermann, Tristan; von der Au, Marcus; Reese, Anna; Klein, Ole; Hildebrandt, Lars; Pröfrock, Daniel (2020): Substituting HF by HBF 4 – an optimized digestion method for multi-elemental sediment analysis via ICP-MS/MS. Analytical Methods, 12(30), 3778-3787, https://doi.org/10.1039/D0AY01049A
Project(s):
Helmholtz-Zentrum Hereon (Hereon)
Coverage:
Median Latitude: 54.552763 * Median Longitude: 6.618340 * South-bound Latitude: 53.523016 * West-bound Longitude: 3.343307 * North-bound Latitude: 55.921855 * East-bound Longitude: 8.718262
Date/Time Start: 2021-04-13T07:48:00 * Date/Time End: 2021-04-20T09:19:00
Minimum DEPTH, sediment/rock: 0 m * Maximum DEPTH, sediment/rock: 0 m
Event(s):
AT004_Stat_S_001_BC (AT004_Stat_S_001) * Latitude: 53.883232 * Longitude: 8.718262 * Date/Time: 2021-04-13T07:48:00 * Location: German Bight * Campaign: Atair004 (AT004) * Basis: Atair * Method/Device: Box corer (BC)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Event label | Event | ||||
2 | Sample code/label | Sample label | ||||
3 | International Generic Sample Number | IGSN | ||||
4 | Optional event label | Event 2 | ||||
5 | Station label | Station | ||||
6 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
7 | Latitude of event | Latitude | ||||
8 | Longitude of event | Longitude | ||||
9 | Date/Time of event | Date/Time | ||||
10 | Method/Device of event | Method/Device | ||||
11 | Elevation of event | Elevation | m | |||
12 | Chromium | Cr | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
13 | Chromium, limit of detection | Cr LOD | µg/kg | |||
14 | Chromium, limit of quantification | Cr LOQ | µg/kg | |||
15 | Chromium, uncertainty | Cr unc | ± | |||
16 | Cobalt | Co | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
17 | Cobalt, limit of detection | Co LOD | µg/kg | |||
18 | Cobalt, limit of quantification | Co LOQ | µg/kg | |||
19 | Cobalt, uncertainty | Co unc | ± | |||
20 | Nickel | Ni | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
21 | Nickel, limit of detection | Ni LOD | µg/kg | |||
22 | Nickel, limit of quantification | Ni LOQ | µg/kg | |||
23 | Nickel, uncertainty | Ni unc | ± | |||
24 | Copper | Cu | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
25 | Copper, limit of detection | Cu LOD | µg/kg | |||
26 | Copper, limit of quantification | Cu LOQ | µg/kg | |||
27 | Copper, uncertainty | Cu unc | ± | |||
28 | Zinc | Zn | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
29 | Zinc, limit of detection | Zn LOD | µg/kg | |||
30 | Zinc, limit of quantification | Zn LOQ | µg/kg | |||
31 | Zinc, uncertainty | Zn unc | ± | |||
32 | Gallium | Ga | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
33 | Gallium, limit of detection | Ga LOD | µg/kg | |||
34 | Gallium, limit of quantification | Ga LOQ | µg/kg | |||
35 | Gallium, uncertainty | Ga unc | ± | |||
36 | Aluminium | Al3+ | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
37 | Aluminium, limit of detection | Al LOD | µg/kg | |||
38 | Aluminium, limit of quantification | Al LOQ | µg/kg | |||
39 | Aluminium, uncertainty | Al unc | ± | |||
40 | Potassium | K+ | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
41 | Potassium, limit of detection | K LOD | µg/kg | |||
42 | Potassium, limit of quantification | K LOQ | µg/kg | |||
43 | Potassium, uncertainty | K unc | ± | |||
44 | Calcium | Ca | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
45 | Calcium, limit of detection | Ca LOD | µg/kg | |||
46 | Calcium, limit of quantification | Ca LOQ | µg/kg | |||
47 | Calcium, uncertainty | Ca unc | ± | |||
48 | Magnesium | Mg | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
49 | Magnesium, limit of detection | Mg LOD | µg/kg | |||
50 | Magnesium, limit of quantification | Mg LOQ | µg/kg | |||
51 | Magnesium, uncertainty | Mg unc | ± | |||
52 | Iron | Fe | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
53 | Iron, limit of detection | Fe LOD | µg/kg | |||
54 | Iron, limit of quantification | Fe LOQ | µg/kg | |||
55 | Iron, uncertainty | Fe unc | ± | |||
56 | Manganese | Mn | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
57 | Manganese, limit of detection | Mn LOD | µg/kg | |||
58 | Manganese, limit of quantification | Mn LOQ | µg/kg | |||
59 | Manganese, uncertainty | Mn unc | ± | |||
60 | Barium | Ba | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
61 | Barium, limit of detection | Ba LOD | µg/kg | |||
62 | Barium, limit of quantification | Ba LOQ | µg/kg | |||
63 | Barium, uncertainty | Ba unc | ± | |||
64 | Thulium | Tm | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
65 | Thulium, limit of detection | Tm LOD | µg/kg | |||
66 | Thulium, limit of quantification | Tm LOQ | µg/kg | |||
67 | Thulium, uncertainty | Tm unc | ± | |||
68 | Ytterbium | Yb | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
69 | Ytterbium, limit of detection | Yb LOD | µg/kg | |||
70 | Ytterbium, limit of quantification | Yb LOQ | µg/kg | |||
71 | Ytterbium, uncertainty | Yb unc | ± | |||
72 | Lutetium | Lu | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
73 | Lutetium, limit of detection | Lu LOD | µg/kg | |||
74 | Lutetium, limit of quantification | Lu LOQ | µg/kg | |||
75 | Lutetium, uncertainty | Lu unc | ± | |||
76 | Tantalum | Ta | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
77 | Tantalum, limit of detection | Ta LOD | µg/kg | |||
78 | Tantalum, limit of quantification | Ta LOQ | µg/kg | |||
79 | Tantalum, uncertainty | Ta unc | ± | |||
80 | Lithium | Li | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
81 | Lithium, limit of detection | Li LOD | µg/kg | |||
82 | Lithium, limit of quantification | Li LOQ | µg/kg | |||
83 | Lithium, uncertainty | Li unc | ± | |||
84 | Selenium | Se | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
85 | Selenium, limit of detection | Se LOD | µg/kg | |||
86 | Selenium, limit of quantification | SeLOQ | µg/kg | |||
87 | Selenium, uncertainty | Se | ± | |||
88 | Gadolinium | Gd | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
89 | Gadolinium, limit of detection | Gd LOD | µg/kg | |||
90 | Gadolinium, limit of quantification | Gd LOQ | µg/kg | |||
91 | Gadolinium, uncertainty | Gd unc | ± | |||
92 | Terbium | Tb | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
93 | Terbium, limit of detection | Tb LOD | µg/kg | |||
94 | Terbium, limit of quantification | Tb LOQ | µg/kg | |||
95 | Terbium, uncertainty | Tb unc | ± | |||
96 | Dysprosium | Dy | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
97 | Dysprosium, limit of detection | Dy LOD | µg/kg | |||
98 | Dysprosium, limit of quantification | Dy LOQ | µg/kg | |||
99 | Dysprosium, uncertainty | Dy unc | ± | |||
100 | Holmium | Ho | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
101 | Holmium, limit of detection | Ho LOD | µg/kg | |||
102 | Holmium, limit of quantification | Ho LOQ | µg/kg | |||
103 | Holmium, uncertainty | Ho unc | ± | |||
104 | Erbium | Er | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
105 | Erbium, limit of detection | Er LOD | µg/kg | |||
106 | Erbium, limit of quantification | Er LOQ | µg/kg | |||
107 | Erbium, uncertainty | Er unc | ± | |||
108 | Zirconium | Zr | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
109 | Zirconium, limit of detection | Zr LOD | µg/kg | |||
110 | Zirconium, limit of quantification | Zr LOQ | µg/kg | |||
111 | Zirconium, uncertainty | Zr unc | ± | |||
112 | Lanthanum | La | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
113 | Lanthanum, limit of detection | La LOD | µg/kg | |||
114 | Lanthanum, limit of quantification | La LOQ | µg/kg | |||
115 | Lanthanum, uncertainty | La unc | ± | |||
116 | Europium | Eu | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
117 | Europium, limit of detection | Eu LOD | µg/kg | |||
118 | Europium, limit of quantification | Eu LOQ | µg/kg | |||
119 | Europium, uncertainty | Eu unc | ± | |||
120 | Niobium | Nb | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
121 | Niobium, limit of detection | Nb LOD | µg/kg | |||
122 | Niobium, limit of quantification | Nb LOQ | µg/kg | |||
123 | Niobium, uncertainty | Nb unc | ± | |||
124 | Cerium | Ce | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
125 | Cerium, limit of detection | Ce LOD | µg/kg | |||
126 | Cerium, limit of quantification | Ce LOQ | µg/kg | |||
127 | Cerium, uncertainty | Ce unc | ± | |||
128 | Praseodymium | Pr | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
129 | Praseodymium, limit of detection | Pr LOD | µg/kg | |||
130 | Praseodymium, limit of quantification | Pr LOQ | µg/kg | |||
131 | Praseodymium, uncertainty | Pr unc | ± | |||
132 | Neodymium | Nd | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
133 | Neodymium, limit of detection | Nd LOD | µg/kg | |||
134 | Neodymium, limit of quantification | Nd LOQ | µg/kg | |||
135 | Neodymium, uncertainty | Nd unc | ± | |||
136 | Samarium | Sm | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
137 | Samarium, limit of detection | Sm LOD | µg/kg | |||
138 | Samarium, limit of quantification | Sm LOQ | µg/kg | |||
139 | Samarium, uncertainty | Sm unc | ± | |||
140 | Thorium | Th | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
141 | Thorium, limit of detection | Th LOD | µg/kg | |||
142 | Thorium, limit of quantification | Th LOQ | µg/kg | |||
143 | Thorium, uncertainty | Th unc | ± | |||
144 | Uranium | U | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
145 | Uranium, limit of detection | U LOD | µg/kg | |||
146 | Uranium, limit of quantification | U LOQ | µg/kg | |||
147 | Uranium, uncertainty | U unc | ± | |||
148 | Phosphorus | P | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
149 | Phosphorus, limit of detection | P LOD | µg/kg | |||
150 | Phosphorus, limit of quantification | PLOQ | µg/kg | |||
151 | Phosphorus, uncertainty | P unc | ± | |||
152 | Scandium | Sc | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
153 | Scandium, limit of detection | Sc LOD | µg/kg | |||
154 | Scandium, limit of quantification | Sc LOQ | µg/kg | |||
155 | Scandium, uncertainty | Sc unc | ± | |||
156 | Titanium | Ti | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
157 | Titanium, limit of detection | Ti LOD | µg/kg | |||
158 | Titanium, limit of quantification | Ti LOQ | µg/kg | |||
159 | Titanium, uncertainty | Ti unc | ± | |||
160 | Vanadium | V | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
161 | Vanadium, limit of detection | V LOD | µg/kg | |||
162 | Vanadium, limit of quantification | V LOQ | µg/kg | |||
163 | Vanadium, uncertainty | V unc | ± | |||
164 | Indium | In | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
165 | Indium, limit of detection | In LOD | µg/kg | |||
166 | Indium, limit of quantification | In LOQ | µg/kg | |||
167 | Indium, uncertainty | In unc | ± | |||
168 | Antimony | Sb | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
169 | Antimony, limit of detection | Sb LOD | µg/kg | |||
170 | Antimony, limit of quantification | Sb LOQ | µg/kg | |||
171 | Antimony, uncertainty | Sb unc | ± | |||
172 | Caesium | Cs | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
173 | Caesium, limit of detection | Cs LOD | µg/kg | |||
174 | Caesium, limit of quantification | Cs LOQ | µg/kg | |||
175 | Caesium, uncertainty | Cs unc | ± | |||
176 | Thallium | Tl | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
177 | Thallium, limit of detection | Tl LOD | µg/kg | |||
178 | Thallium, limit of quantification | Tl LOQ | µg/kg | |||
179 | Thallium, uncertainty | Tl unc | ± | |||
180 | Lead | Pb | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
181 | Lead, limit of detection | Pb LOD | µg/kg | |||
182 | Lead, limit of quantification | Pb LOQ | µg/kg | |||
183 | Lead, uncertainty | Pb unc | ± | |||
184 | Bismuth | Bi | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
185 | Bismuth, limit of detection | Bi LOD | µg/kg | |||
186 | Bismuth, limit of quantification | Bi LOQ | µg/kg | |||
187 | Bismuth, uncertainty | Bi unc | ± | |||
188 | Germanium | Ge | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
189 | Germanium, limit of detection | Ge LOD | µg/kg | |||
190 | Germanium, limit of quantification | Ge LOQ | µg/kg | |||
191 | Germanium, uncertainty | Ge unc | ± | |||
192 | Arsenic | As | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
193 | Arsenic, limit of detection | As LOD | µg/kg | |||
194 | Arsenic, limit of quantification | As LOQ | µg/kg | |||
195 | Arsenic, uncertainty | As unc | ± | |||
196 | Rubidium | Rb | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
197 | Rubidium, limit of detection | Rb LOD | µg/kg | |||
198 | Rubidium, limit of quantification | Rb LOQ | µg/kg | |||
199 | Rubidium, uncertainty | Rb unc | ± | |||
200 | Strontium | Sr | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
201 | Strontium, limit of detection | Sr LOD | µg/kg | |||
202 | Strontium, limit of quantification | Sr LOQ | µg/kg | |||
203 | Strontium, uncertainty | Sr unc | ± | |||
204 | Molybdenum | Mo | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
205 | Molybdenum, limit of detection | Mo LOD | µg/kg | |||
206 | Molybdenum, limit of quantification | Mo LOQ | µg/kg | |||
207 | Molybdenum, uncertainty | Mo unc | ± | |||
208 | Cadmium | Cd | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
209 | Cadmium, limit of detection | Cd LOD | µg/kg | |||
210 | Cadmium, limit of quantification | Cd LOQ | µg/kg | |||
211 | Cadmium, uncertainty | Cd unc | ± | |||
212 | Tungsten | W | µg/kg | Element analysis grain size fraction < 20 microns via ICP-MS (total digest) | measured in sediment, <20 µm | |
213 | Tungsten, limit of detection | W LOD | µg/kg | |||
214 | Tungsten, limit of quantification | W LOQ | µg/kg | |||
215 | Tungsten, uncertainty | W unc | ± |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
8760 data points
Download Data
View dataset as HTML (shows only first 2000 rows)
Datasets with similar metadata
- Wippermann, D; Petrauskas, C; Faust, S et al. (2025): Metal distribution for sediment samples of the cruise AT010. https://doi.org/10.1594/PANGAEA.973676
- Ebeling, A; Petrauskas, C; Kruse, M et al. (2023): Metal distribution for sediment samples of Ludwig Prandtl cruise LP20200629. https://doi.org/10.1594/PANGAEA.963886
- Wippermann, D; Pieper, A; Zimmermann, T et al. (2025): Trace metal distribution for water samples of the cruise AT004. https://doi.pangaea.de/10.1594/PANGAEA.973612
Users interested in this dataset were also interested in
- Wippermann, D; Zimmermann, T; Klein, O et al. (2024): Grain size distribution for sediment samples of the cruise AT004. https://doi.org/10.1594/PANGAEA.973616
- Bracher, A; Liu, Y; Wiegmann, S et al. (2025): Absorption coefficients by coloured dissolved organic matter from the East Greenland Sea measured at fixed stations with a Liquid Waveguide Capillary Cell system during POLARSTERN cruise PS107. https://doi.org/10.1594/PANGAEA.971585
- Van Tiggelen, M; Smeets, PCJP; Reijmer, CH et al. (2024): Daily surface energy balance (SEB) and quality-controlled meteorological quantities measured at station GRL_KPC_L on the Greenland ice sheet. https://doi.org/10.1594/PANGAEA.970141