Bouat, Loic (2024): Uranium-Lead LA-ICPMS analysis of quality control calcite sample WC1 [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.948395 (DOI registration in progress), In: Bouat, L (2024): Uranium-Lead LA-ICPMS analysis of calcite samples from the Vendée coast [dataset publication series]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.948396 (DOI registration in progress)

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX Citation

Abstract:
This data provide all details concerning LA-ICPMS U-Pb analyzis on calcites from the Vendée coast in France. The 3 calcites samples PP5, PN201 and ASN201 come from veins hosted in the sedimentary cover below the unconformity with the Armorican Massif below.
The LA-ICPMS U-Pb analyzis were proceed with the GeOHeLiS Platform from Université Rennes 1 (France) using WC1 standard as quality control.
Keyword(s):
calcite; dating; U-Pb dating
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Year of analysisYear analysisa ADBouat, Loic
2IdentificationIDBouat, Loic
3Lead-206206Pbmg/kgBouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometerppm
4Uranium-238238Umg/kgBouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometerppm
5Uranium-238/Lead-206 ratio238U/206PbBouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer
6Uranium-238/Lead-206, error, relative238U/206Pb e rel%Bouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer2se
7Lead-207/Lead-206 ratio207Pb/206PbBouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer
8Lead-207/Lead-206, error, relative207Pb/206Pb e rel%Bouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer2se
9Correlation coefficient, isotope ratio errorRhoBouat, Loic207Pb/206Pb
10Lead-207/Uranium-235 ratio207Pb/235UBouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer
11Lead-207/Uranium-235, error, relative207Pb/235U e rel%Bouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer2se
12Lead-206/Uranium-238 ratio206Pb/238UBouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer
13Lead-206/Uranium-238, error, relative206Pb/238U e rel%Bouat, LoicLA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer2se
14Correlation coefficient, isotope ratio errorRhoBouat, Loic206Pb/238U
15Age, datedAge datedkaBouat, LoicAge, 207Pb/206Pb Lead-Lead
16Age, dated standard errorAge std e±Bouat, LoicAge, 207Pb/206Pb Lead-Lead2se (abs)
17Age, datedAge datedkaBouat, LoicAge, 206Pb/238U Lead-Uranium
18Age, dated standard errorAge std e±Bouat, LoicAge, 206Pb/238U Lead-Uranium2se (abs)
19Age, datedAge datedkaBouat, LoicAge, 207Pb/235U Lead-Uranium
20Age, dated standard errorAge std e±Bouat, LoicAge, 207Pb/235U Lead-Uranium2se (abs)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
200 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML