Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Bouat, Loic (2024): Uranium-Lead LA-ICPMS analysis of calcite sample Vendee_PP5 from the Vendée coast [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.948391, In: Bouat, L (2024): Uranium-Lead LA-ICPMS analysis of calcite samples from the Vendée coast [dataset publication series]. PANGAEA, https://doi.org/10.1594/PANGAEA.948396

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2024-09-16DOI registered: 2024-10-14

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Abstract:
This data provide all details concerning LA-ICPMS U-Pb analyzis on calcites from the Vendée coast in France. The 3 calcites samples PP5, PN201 and ASN201 come from veins hosted in the sedimentary cover below the unconformity with the Armorican Massif below.
The LA-ICPMS U-Pb analyzis were proceed with the GeOHeLiS Platform from Université Rennes 1 (France) using WC1 standard as quality control.
Keyword(s):
Calcite; dating; U-Pb dating
Coverage:
Latitude: 46.426810 * Longitude: -1.647895
Minimum ELEVATION: m a.s.l. * Maximum ELEVATION: m a.s.l.
Event(s):
Vendee_PP5 * Latitude: 46.426810 * Longitude: -1.647895 * Method/Device: Rock sample (ROCK)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1LATITUDELatitudeBouat, LoicGeocode
2LONGITUDELongitudeBouat, LoicGeocode
3ELEVATIONElevationm a.s.l.Bouat, LoicGeocode
4Year of analysisYear analysisa ADBouat, Loic
5IdentificationIDBouat, Loic
6Lead-206206Pbmg/kgBouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)ppm
7Uranium-238238Umg/kgBouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)ppm
8Uranium-238/Lead-206 ratio238U/206PbBouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)
9Uranium-238/Lead-206 ratio, error, relative238U/206Pb e rel%Bouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)2se
10Lead-207/Lead-206 ratio207Pb/206PbBouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)
11Lead-207/Lead-206 ratio, error, relative207Pb/206Pb e rel%Bouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)2se
12Correlation coefficient, isotope ratio errorRhoBouat, Loic207Pb/206Pb
13Lead-207/Uranium-235 ratio207Pb/235UBouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)
14Lead-207/Uranium-235 ratio, error, relative207Pb/235U e rel%Bouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)2se
15Lead-206/Uranium-238 ratio206Pb/238UBouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)
16Lead-206/Uranium-238 ratio, error, relative206Pb/238U e rel%Bouat, LoicLaser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS)2se
17Correlation coefficient, isotope ratio errorRhoBouat, Loic206Pb/238U
18Age, datedAge datedkaBouat, LoicAge, 207Pb/206Pb Lead-Lead
19Age, dated standard errorAge std e±Bouat, LoicAge, 207Pb/206Pb Lead-Lead2se (abs)
20Age, datedAge datedkaBouat, LoicAge, 206Pb/238U Lead-Uranium
21Age, dated standard errorAge std e±Bouat, LoicAge, 206Pb/238U Lead-Uranium2se (abs)
22Age, datedAge datedkaBouat, LoicAge, 207Pb/235U Lead-Uranium
23Age, dated standard errorAge std e±Bouat, LoicAge, 207Pb/235U Lead-Uranium2se (abs)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
400 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML