Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science
Abstract:
The river Elbe flows through Geesthacht right before the tidal part of the Elbe begins. In order to monitor and investigate the metal load and transport from the upstream river with a study focus on extreme events, water samples were taken weekly from the Geesthacht riverbank a couple of kilometers upstream of the weir starting in April 2018 and going until April 2023. During extreme events, i.e. floods or droughts, the sampling interval was increased to (bi-)daily sampling. The water samples were taken in pre-cleaned LDPE bottles, filtered over <0.45 µm polycarbonate filters into pre-cleaned LDPE bottles/tubes and acidified with nitric acid. The filtrates were then measured for their (trace) metal concentrations with ICP-MS/MS coupled online to a seaFAST preconcentration and matrix removal system. The physiochemical parameters pH value, dissolved oxygen, temperature and conductivity were measured for each sample using a corresponding multimeter probe.
Related to:
Ebeling, Anna; Zimmermann, Tristan; Klein, Ole; Irrgeher, Johanna; Pröfrock, Daniel (2022): Analysis of Seventeen Certified Water Reference Materials for Trace and Technology-Critical Elements. Geostandards and Geoanalytical Research, 46(2), 351-378, https://doi.org/10.1111/ggr.12422
Project(s):
Coverage:
Latitude: 53.421261 * Longitude: 10.387050
Date/Time Start: 2018-08-20T22:00:00 * Date/Time End: 2023-04-14T13:00:00
Minimum DEPTH, water: 0.5 m * Maximum DEPTH, water: 0.5 m
Event(s):
ElbeElementExplorer_Gee_Langzeit * Latitude: 53.421261 * Longitude: 10.387050 * Date/Time Start: 2018-08-20T22:00:00 * Date/Time End: 2023-04-14T13:00:00 * Location: Elbe, Germany, Europe * Method/Device: Monitoring station (MONS) * Comment: event was not logged in DSHIP
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventRust, Bettina
2Sample code/labelSample labelRust, Bettina
3DEPTH, waterDepth watermRust, BettinaGeocode
4LATITUDELatitudeRust, BettinaGeocode
5LONGITUDELongitudeRust, BettinaGeocode
6DATE/TIMEDate/TimeRust, BettinaGeocode – UTC
7Sample methodSample methodRust, BettinaDevice
8Temperature, waterTemp°CRust, BettinaMulti-parameter portable meter, Xylem Analytics, WTW MultiLine® 3630 IDSmeasured in water column, quality flag: 0
9OxygenO2mg/lRust, BettinaMulti-parameter portable meter, Xylem Analytics, WTW MultiLine® 3630 IDSmeasured in water column, quality flag: 0
10pHpHRust, BettinaMulti-parameter portable meter, Xylem Analytics, WTW MultiLine® 3630 IDSmeasured in water column, quality flag: 0
11ConductivityCondmS/cmRust, BettinaMulti-parameter portable meter, Xylem Analytics, WTW MultiLine® 3630 IDSmeasured in water column, quality flag: 0
12BerylliumBeng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
13Beryllium, limit of detectionBe LODng/lRust, Bettina
14Beryllium, limit of quantificationBe LOQng/lRust, Bettina
15Beryllium, uncertaintyBe unc±Rust, Bettina
16SeleniumSeng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
17Selenium, limit of detectionSe LODng/lRust, Bettina
18Selenium, limit of quantificationSe LOQng/lRust, Bettina
19Selenium, uncertaintySe±Rust, Bettina
20RubidiumRung/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 88 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
21Rubidium, limit of detectionRu LODng/lRust, Bettina
22Rubidium, limit of quantificationRu LOQng/lRust, Bettina
23Rubidium, uncertaintyRb unc±Rust, Bettina
24StrontiumSrng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 88 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
25Strontium, limit of detectionSr LODng/lRust, Bettina
26Strontium, limit of quantificationSr LOQng/lRust, Bettina
27Strontium, uncertaintySr unc±Rust, Bettina
28SilverAgng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 88 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
29Silver, limit of detectionAg LODng/lRust, Bettina
30Silver, limit of quantificationAg LOQng/lRust, Bettina
31Silver, uncertaintyAg unc±Rust, Bettina
32TelluriumTeng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
33Tellurium, limit of detectionTe LODng/lRust, Bettina
34Tellurium, limit of quantificationTe LOQng/lRust, Bettina
35Tellurium, uncertaintyTe unc±Rust, Bettina
36BariumBang/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
37Barium, limit of detectionBa LODng/lRust, Bettina
38Barium, limit of quantificationBA LOQng/lRust, Bettina
39Barium, uncertaintyBa unc±Rust, Bettina
40LeadPbng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
41Lead, limit of detectionPb LODng/lRust, Bettina
42Lead, limit of quantificationPb LOQng/lRust, Bettina
43Lead, uncertaintyPb unc±Rust, Bettina
44ThoriumThng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
45Thorium, limit of detectionTh LODng/lRust, Bettina
46Thorium, limit of quantificationTh LOQng/lRust, Bettina
47Thorium, uncertaintyTh unc±Rust, Bettina
48LithiumLing/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
49Lithium, limit of detectionLi LODng/lRust, Bettina
50Lithium, limit of quantificationLi LOQng/lRust, Bettina
51Lithium, uncertaintyLi unc±Rust, Bettina
52SodiumNa+ng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
53Sodium, limit of detectionNa+ LODng/lRust, Bettina
54Sodium, limit of quantificationNa+ LOQng/lRust, Bettina
55Sodium, uncertaintyNa unc±Rust, Bettina
56MagnesiumMg2+ng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
57Magnesium, limit of detectionMg2+ LODng/lRust, Bettina
58Magnesium, limit of quantificationMg2+ LOQng/lRust, Bettina
59Magnesium, uncertaintyMg unc±Rust, Bettina
60PotassiumK+ng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
61Potassium, limit of detectionK+ LODng/lRust, Bettina
62Potassium, limit of quantificationK+ LOQng/lRust, Bettina
63Potassium, uncertaintyK unc±Rust, Bettina
64CalciumCa2+ng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
65Calcium, limit of detectionCa2+ LODng/lRust, Bettina
66Calcium, limit of quantificationCa2+ LOQng/lRust, Bettina
67Calcium, uncertaintyCa unc±Rust, Bettina
68ChromiumCrng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
69Chromium, limit of detectionCr LODng/lRust, Bettina
70Chromium, limit of quantificationCr LOQng/lRust, Bettina
71Chromium, standard deviationCr std dev±Rust, Bettina
72ManganeseMnng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
73Manganese, limit of detectionMn LODng/lRust, Bettina
74Manganese, limit of quantificationMn LOQng/lRust, Bettina
75Manganese, uncertaintyMn unc±Rust, Bettina
76CobaltCong/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
77Cobalt, limit of detectionCo LODng/lRust, Bettina
78Cobalt, limit of quantificationCo LOQng/lRust, Bettina
79Cobalt, uncertaintyCo unc±Rust, Bettina
80NickelNing/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
81Nickel, limit of detectionNi LODng/lRust, Bettina
82Nickel, limit of quantificationNi LOQng/lRust, Bettina
83Nickel, uncertaintyNi unc±Rust, Bettina
84CopperCung/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 88 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
85Copper, limit of detectionCu LODng/lRust, Bettina
86Copper, limit of quantificationCu LOQng/lRust, Bettina
87Copper, uncertaintyCu unc±Rust, Bettina
88ZincZnng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 104 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
89Zinc, limit of detectionZn LODng/lRust, Bettina
90Zinc, limit of quantificationZn LOQng/lRust, Bettina
91Zinc, uncertaintyZn unc±Rust, Bettina
92GalliumGang/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
93Gallium, limit of detectionGa LODng/lRust, Bettina
94Gallium, limit of quantificationGa LOQng/lRust, Bettina
95Gallium, uncertaintyGa unc±Rust, Bettina
96VanadiumVng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 88 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
97Vanadium, limit of detectionV LODng/lRust, Bettina
98Vanadium, limit of quantificationV LOQng/lRust, Bettina
99Vanadium, uncertaintyV unc±Rust, Bettina
100ArsenicAsng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
101Arsenic, limit of detectionAs LODng/lRust, Bettina
102Arsenic, limit of quantificationAs LOQng/lRust, Bettina
103Arsenic, uncertaintyAs unc±Rust, Bettina
104MolybdenumMong/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 88 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
105Molybdenum, limit of detectionMo LODng/lRust, Bettina
106Molybdenum, limit of quantificationMo LOQng/lRust, Bettina
107Molybdenum, uncertaintyMo unc±Rust, Bettina
108BismuthBing/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
109Bismuth, limit of detectionBi LODng/lRust, Bettina
110Bismuth, limit of quantificationBi LOQng/lRust, Bettina
111Bismuth, uncertaintyBi unc±Rust, Bettina
112UraniumUng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
113Uranium, limit of detectionU LODng/lRust, Bettina
114Uranium, limit of quantificationU LOQng/lRust, Bettina
115Uranium, uncertaintyU unc±Rust, Bettina
116BoronBong/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
117Boron, limit of detectionBo LODng/lRust, Bettina
118Boron, uncertaintyBo unc±Rust, Bettina
119CadmiumCdng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 88 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
120Cadmium, limit of detectionCd LODng/lRust, Bettina
121Cadmium, limit of quantificationCd LOQng/lRust, Bettina
122Cadmium, uncertaintyCd unc±Rust, Bettina
123IndiumInng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 104 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
124Indium, limit of detectionIn LODng/lRust, Bettina
125Indium, limit of quantificationIn LOQng/lRust, Bettina
126Indium, uncertaintyIn unc±Rust, Bettina
127AluminiumAlng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 88 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
128Aluminium, limit of detectionAl LODng/lRust, Bettina
129Aluminium, limit of quantificationAl LOQng/lRust, Bettina
130Aluminium, uncertaintyAl unc±Rust, Bettina
131IronFeng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
132Iron, limit of detectionFe LODng/lRust, Bettina
133Iron, limit of quantificationFe LOQng/lRust, Bettina
134Iron, uncertaintyFe unc±Rust, Bettina
135TinSnng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 104 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
136Tin, limit of detectionSn LODng/lRust, Bettina
137Tin, limit of quantificationSn LOQng/lRust, Bettina
138Tin, uncertaintySn unc±Rust, Bettina
139MercuryHgng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
140Mercury, limit of detectionHg LODng/lRust, Bettina
141Mercury, limit of quantificationHg LOQng/lRust, Bettina
142Mercury, uncertaintyHg unc±Rust, Bettina
143ThalliumTlng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
144Thallium, limit of detectionTl LODng/lRust, Bettina
145Thallium, limit of quantificationTl LOQng/lRust, Bettina
146Thallium, uncertaintyTl unc±Rust, Bettina
147RutheniumRung/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
148Ruthenium, limit of detectionRu LODng/lRust, Bettina
149Ruthenium, limit of quantificationRu LOQng/lRust, Bettina
150CaesiumCsng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
151Caesium, limit of detectionCs LODng/lRust, Bettina
152Caesium, limit of quantificationCs LOQng/lRust, Bettina
153Caesium, uncertaintyCs unc±Rust, Bettina
154PlatinumPtng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
155Platinum, limit of detectionPt LODng/lRust, Bettina
156Platinum, limit of quantificationPt LOQng/lRust, Bettina
157PalladiumPdng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
158Palladium, limit of detectionPd LODng/lRust, Bettina
159Palladium, limit of quantificationPd LOQng/lRust, Bettina
160Palladium, uncertaintyPd unc±Rust, Bettina
161ZirconiumZrng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 88 to 103: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
162Zirconium, limit of detectionZr LODng/lRust, Bettina
163Zirconium, limit of quantificationZr LOQng/lRust, Bettina
164Zirconium, uncertaintyZr unc±Rust, Bettina
165TungstenWng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 88 to 103: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
166Tungsten, limit of detectionW LODng/lRust, Bettina
167Tungsten, limit of quantificationW LOQng/lRust, Bettina
168Tungsten, uncertaintyW unc±Rust, Bettina
169RheniumReng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
170Rhenium, limit of detectionRe LODng/lRust, Bettina
171Rhenium, limit of quantificationRe LOQng/lRust, Bettina
172Rhenium, uncertaintyRe unc±Rust, Bettina
173AntimonySbng/lRust, BettinaElement analysis water via ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0; samples 62 and 67 to 145: Element analysis water via ICP-MS (< 0,45 micometer filtrate), all other samples: Element analysis water via SeaFAST-ICP-MS (<0,45 micrometer filtrate)
174Antimony, limit of detectionSb LODng/lRust, Bettina
175Antimony, limit of quantificationSb LOQng/lRust, Bettina
176Antimony, uncertaintySb unc±Rust, Bettina
177TitaniumTing/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
178Titanium, limit of detectionTi LODng/lRust, Bettina
179Titanium, limit of quantificationTi LOQng/lRust, Bettina
180Titanium, uncertaintyTi unc±Rust, Bettina
181YttriumYng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
182Yttrium, limit of detectionY LODng/lRust, Bettina
183Yttrium, limit of quantificationY LOQng/lRust, Bettina
184Yttrium, uncertaintyY unc±Rust, Bettina
185LanthanumLang/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
186Lanthanum, limit of detectionLa LODng/lRust, Bettina
187Lanthanum, limit of quantificationLa LOQng/lRust, Bettina
188Lanthanum, uncertaintyLa unc±Rust, Bettina
189CeriumCeng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
190Cerium, limit of detectionCe LODng/lRust, Bettina
191Cerium, limit of quantificationCe LOQng/lRust, Bettina
192Cerium, uncertaintyCe unc±Rust, Bettina
193PraseodymiumPrng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
194Praseodymium, limit of detectionPr LODng/lRust, Bettina
195Praseodymium, limit of quantificationPr LOQng/lRust, Bettina
196Praseodymium, uncertaintyPr unc±Rust, Bettina
197NeodymiumNdng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
198Neodymium, limit of detectionNd LODng/lRust, Bettina
199Neodymium, limit of quantificationNd LOQng/lRust, Bettina
200Neodymium, uncertaintyNd unc±Rust, Bettina
201SamariumSmng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
202Samarium, limit of detectionSm LODng/lRust, Bettina
203Samarium, limit of quantificationSm LOQng/lRust, Bettina
204Samarium, uncertaintySm unc±Rust, Bettina
205EuropiumEung/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
206Europium, limit of detectionEu LODng/lRust, Bettina
207Europium, limit of quantificationEu LOQng/lRust, Bettina
208Europium, uncertaintyEu unc±Rust, Bettina
209GadoliniumGdng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
210Gadolinium, limit of detectionGd LODng/lRust, Bettina
211Gadolinium, limit of quantificationGd LOQng/lRust, Bettina
212Gadolinium, uncertaintyGd unc±Rust, Bettina
213TerbiumTbng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
214Terbium, limit of detectionTb LODng/lRust, Bettina
215Terbium, limit of quantificationTb LOQng/lRust, Bettina
216Terbium, uncertaintyTb unc±Rust, Bettina
217DysprosiumDyng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
218Dysprosium, limit of detectionDy LODng/lRust, Bettina
219Dysprosium, limit of quantificationDy LOQng/lRust, Bettina
220Dysprosium, uncertaintyDy unc±Rust, Bettina
221HolmiumHong/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
222Holmium, limit of detectionHo LODng/lRust, Bettina
223Holmium, limit of quantificationHo LOQng/lRust, Bettina
224Holmium, uncertaintyHo unc±Rust, Bettina
225ErbiumErng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
226Erbium, limit of detectionEr LODng/lRust, Bettina
227Erbium, limit of quantificationEr LOQng/lRust, Bettina
228Erbium, uncertaintyEr unc±Rust, Bettina
229ThuliumTmng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
230Thulium, limit of detectionTm LODng/lRust, Bettina
231Thulium, limit of quantificationTm LOQng/lRust, Bettina
232Thulium, uncertaintyTm unc±Rust, Bettina
233YtterbiumYbng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
234Ytterbium, limit of detectionYb LODng/lRust, Bettina
235Ytterbium, limit of quantificationYb LOQng/lRust, Bettina
236Ytterbium, uncertaintyYb unc±Rust, Bettina
237LutetiumLung/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
238Lutetium, limit of detectionLu LODng/lRust, Bettina
239Lutetium, limit of quantificationLu LOQng/lRust, Bettina
240Lutetium, uncertaintyLu unc±Rust, Bettina
241ScandiumScng/lRust, BettinaElement analysis water via SeaFAST-ICP-MS (<0.45 µm filtrate)measured in water column, < 0.45 microm filtrate, quality flag: 0
242Scandium, limit of detectionSc LODng/lRust, Bettina
243Scandium, limit of quantificationSc LOQng/lRust, Bettina
244Scandium, uncertaintySc unc±Rust, Bettina
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
33776 data points

Download Data (login required; moratorium until 2028-06-16)

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)