Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Kossack, Michael; Titschack, Jürgen; Anderson, Chloe H; Scholz, Florian; Zabel, Matthias: CT-scan of sediment core GeoB23812-25 form METEOR cruise M157, Namibian shelf [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.995143 (dataset in review), In: Kossack, M et al.: Solid phase geochmical data, 14C ages and sedimentary data from multicores and gravity cores form METEOR cruise M157, Namibian shelf [dataset bundled publication]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.995137 (dataset in review)

ShareShow MapGoogle Earth

Abstract:
Computed Tomography (CT)-scan data form RV Meteor cruise M157 to the Namibian, site GeoB23812-25 are presented here. Sediments were recovered using gravity coring. Both, depth in core (cm) and the corrected depth below seafloor (cm) are presented. Gravity core depth was adjusted to extend the paired multicore from the site. The offset was determined visually, based on eight pore water constituent profiles.
For CT-scans the gravity core was kept in PVC liner and scanned using a Toshiba Aquilion 64™ Computed Tomography (CT) scanner at the hospital Klinikum Bremen-Mitte, with an X-ray source voltage of 120 kV and a current of 600 mA. The CT scan has a resolution of 0.351 mm in x- and y-direction and 0.5 mm resolution in z-direction. The z-direction represents the depth along the core axes, while x and y are perpendicular to the core axes (reconstruction interval: 0.3 mm). The obtained CT data were processed using the Amira ZIB edition software version 2017.39 (Stalling et al., (2005); http://amira.zib.de).
Keyword(s):
14C dating; Benguela Upwelling System; CT-scan; ICP-MS; Rare earth elements; redox sensitive metals; trace- and major elements
Related to:
Kossack, Michael; Anderson, Chloe H; Römer-Stange, Nikolas; Titschack, Jürgen; Scholz, Florian; Zabel, Matthias (submitted): Depositional history of the Namibian mud belt reveals late Holocene weakening of the Benguela Coastal Current. Geochemistry, Geophysics, Geosystems
References:
Stalling, Detlev; Westerhoff, Malte; Hege, Hans-Christian (2005): Amira: A Highly Interactive System for Visual Data Analysis. In: Hansen, C.D., Johnson, C.R. (Eds.), Visualization Handbook. Butterworth-Heinemann, Burlington, 749-767, https://doi.org/10.1016/B978-012387582-2/50040-X
Coverage:
Latitude: -22.998917 * Longitude: 13.866333
Date/Time Start: 2019-08-27T14:33:00 * Date/Time End: 2019-08-27T14:33:00
Minimum DEPTH, sediment/rock: 0.0000 m * Maximum DEPTH, sediment/rock: 1.4100 m
Event(s):
M157_12-25 (GeoB23812-25) * Latitude: -22.998917 * Longitude: 13.866333 * Date/Time: 2019-08-27T14:33:00 * Elevation: -151.0 m * Campaign: M157 (BUSUC 1) * Basis: Meteor (1986) * Method/Device: Gravity corer (GC)
Comment:
Grain size given in 31 bins, 0.25 phi resolution, in units phi, ϕ=−log⁡2(d) (d= diameter in mm), clast size given in 17 bins, 10 degree resolution.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, sediment/rockDepth sedmKossack, MichaelGeocode
2Depth, correctedDepth corrmKossack, Michael
3Exterior, volumeExteriormm3Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38
4Matrix sediment, volumeMatrix sedimentmm3Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38lower core
5Matrix sediment, volumeMatrix sedimentmm3Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38upper core
6Shell volumeShell volmm3Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38
7Sample volumeSamp volmm3Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38Sediment layers
8Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 0: [phi -6.00,-5.75]
9Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 1: [phi -5.75,-5.50]
10Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 2: [phi -5.50,-5.25]
11Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 3: [phi -5.25,-5.00]
12Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 4: [phi -5.00,-4.75]
13Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 5: [-4.75,-4.50]
14Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 6: [phi -4.50,-4.25]
15Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 7: [phi -4.25,-4.00]
16Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 8: [phi -4.00,-3.75]
17Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 9: [phi -3.75,-3.50]
18Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 10: [phi -3.50,-3.25]
19Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 11: [phi -3.25,-3.00]
20Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 12: [phi -3.00,-2.75]
21Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 13: [phi -2.75,-2.50]
22Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 14: [phi -2.50,-2.25]
23Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 15: [phi -2.25,-2.00]
24Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 16: [phi -2.00,-1.75]
25Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 17: [phi -1.75,-1.50]
26Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 18: [phi -1.50,-1.25]
27Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 19: [phi -1.25,-1.00]
28Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 20: [phi -1.00,-0.75]
29Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 21: [phi -0.75,-0.50]
30Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 22: [phi -0.50,-0.25]
31Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 23: [phi -0.25,0.00]
32Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 24: [phi 0.00,0.25]
33Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 25: [phi 0.25,0.50]
34Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 26: [phi 0.50,0.75]
35Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 27: [phi 0.75,1.00]
36Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 28: [phi 1.00,1.25]
37Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 29: [phi 1.25,1.50]
38Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 30: [phi 1.50,1.75]
39Size fractionSize fraction%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 31: [phi 1.75,2.00]
40Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 0: [degree 0.00,10.00]
41Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 1: [degree 10.00,20.00]
42Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 2: [degree 20.00,30.00]
43Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 3: [degree 30.00,40.00]
44Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 4: [degree 40.00,50.00]
45Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 5: [degree 50.00,60.00]
46Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 6: [degree 60.00,70.00]
47Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 7: [degree 70.00,80.00]
48Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 8: [degree 80.00,90.00]
49Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 9: [degree 90.00,100.00]
50Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 10: [degree 100.00,110.00]
51Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 11: [degree 110.00,120.00]
52Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 12: [degree 120.00,130.00]
53Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 13: [degree 130.00,140.00]
54Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 14: [degree 140.00,150.00]
55Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 15: [degree 150.00,160.00]
56Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 16: [degree 160.00,170.00]
57Clast angle distributionClast angle distr%Kossack, MichaelCalculated from CT-scan (Toshiba Aquilion 64™ Computed Tomography (CT) scanner) grey-scale image processing using Amira ZIB edition software version 2017.38bin 17: [degree 170.00,180.00]
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
257824 data points

Download Data (login required; moratorium until 2026-11-06)

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)