Xie, Yihao; Huang, Ting; Zhu, Aili; Lei, Jin; Fernández-Remolar, David C: Element concentrations in phosphoritic limestone (102.6 m) from Los Lagares-1 drill core [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.993263 (dataset in review)
Abstract:
This dataset contains LA-ICP-MS trace element concentrations from phosphatized bioclasts and associated mineral phases in a phosphoritic limestone interval at 101.8 m depth in the Los Lagares-1 borehole (Pedroche Formation, Córdoba, Spain). The data include major, minor, and trace elements, including rare earth elements (REE), measured in carbonate fluorapatite (CFA) and surrounding matrix. The dataset provides information on elemental distributions and geochemical variability linked to phosphogenesis and early diagenetic processes. These data contribute to the reconstruction of paleoenvironmental conditions and nutrient dynamics in a Lower Cambrian reef–lagoon system.
Keyword(s):
Supplement to:
Xie, Yihao; Huang, Ting; Zhu, Aili; Lei, Jin; Fernández-Remolar, David C (in prep.): A multi-analytical approach to the study of phosphatic materials from the Lower Cambrian of Spain. Minerals
Funding:
Ministry of Science and Technology of the People's Republic of China (MOST), grant/award no. 2021YFA0716100: Research on the habitable environments and biosignatures of Mars
Coverage:
Latitude: 37.922778 * Longitude: -4.844167
Minimum DEPTH, sediment/rock: 102.6 m * Maximum DEPTH, sediment/rock: 102.6 m
Event(s):
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | DEPTH, sediment/rock | Depth sed | m | Xie, Yihao | Geocode | |
| 2 | Sample ID | Sample ID | Xie, Yihao | |||
| 3 | Spot identification | Spot ID | Xie, Yihao | Spot and Ablation ID | ||
| 4 | Sample number | Sample no | Xie, Yihao | Sampling point | ||
| 5 | Lithium | Li | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 6 | Beryllium | Be | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 7 | Boron | B | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 8 | Sodium | Na | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 9 | Magnesium carbonate | MgCO3 | % | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 10 | Aluminium | Al | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 11 | Silicon | Si | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 12 | Phosphorus | P | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 13 | Potassium | K | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 14 | Calcium carbonate | CaCO3 | % | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 15 | Scandium | Sc | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 16 | Titanium | Ti | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 17 | Vanadium | V | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 18 | Chromium | Cr | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 19 | Manganese | Mn | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 20 | Iron | Fe | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 21 | Cobalt | Co | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 22 | Nickel | Ni | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 23 | Copper | Cu | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 24 | Zinc | Zn | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 25 | Gallium | Ga | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 26 | Germanium | Ge | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 27 | Arsenic | As | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 28 | Rubidium | Rb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 29 | Strontium | Sr | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 30 | Yttrium | Y | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 31 | Zirconium | Zr | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 32 | Niobium | Nb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 33 | Molybdenum | Mo | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 34 | Silver | Ag | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 35 | Cadmium | Cd | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 36 | Tin | Sn | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 37 | Antimony | Sb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 38 | Caesium | Cs | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 39 | Barium | Ba | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 40 | Lanthanum | La | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 41 | Cerium | Ce | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 42 | Praseodymium | Pr | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 43 | Neodymium | Nd | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 44 | Samarium | Sm | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 45 | Europium | Eu | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 46 | Gadolinium | Gd | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 47 | Terbium | Tb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 48 | Dysprosium | Dy | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 49 | Holmium | Ho | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 50 | Erbium | Er | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 51 | Thulium | Tm | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 52 | Ytterbium | Yb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 53 | Lutetium | Lu | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 54 | Hafnium | Hf | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 55 | Tantalum | Ta | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 56 | Tungsten | W | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 57 | Mercury | Hg | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 58 | Lead | Pb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 59 | Bismuth | Bi | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 60 | Thorium | Th | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 61 | Uranium | U | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1800 data points
