Xie, Yihao; Huang, Ting; Zhu, Aili; Lei, Jin; Fernández-Remolar, David C: Element concentrations in phosphoritic limestone (101.8 m) from Los Lagares-1 drill core [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.993262 (dataset in review)
Abstract:
This dataset contains LA-ICP-MS trace element concentrations from a greenish siltstone interval at 102.6 m depth in the Los Lagares-1 borehole (Pedroche Formation, Córdoba, Spain). The data include major, minor, and trace elements, including rare earth elements (REE), measured in siliciclastic matrix and associated mineral phases. The dataset provides information on geochemical variability, sediment provenance, and early diagenetic processes. These data contribute to understanding paleoenvironmental conditions and facies transitions between phosphoritic and siliciclastic deposits in the Lower Cambrian.
Keyword(s):
Supplement to:
Xie, Yihao; Huang, Ting; Zhu, Aili; Lei, Jin; Fernández-Remolar, David C (in prep.): A multi-analytical approach to the study of phosphatic materials from the Lower Cambrian of Spain. Minerals
Funding:
Ministry of Science and Technology of the People's Republic of China (MOST), grant/award no. 2021YFA0716100: Research on the habitable environments and biosignatures of Mars
Coverage:
Latitude: 37.922778 * Longitude: -4.844167
Minimum DEPTH, sediment/rock: 101.8 m * Maximum DEPTH, sediment/rock: 101.8 m
Event(s):
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | DEPTH, sediment/rock | Depth sed | m | Xie, Yihao | Geocode | |
| 2 | Sample ID | Sample ID | Xie, Yihao | |||
| 3 | Spot identification | Spot ID | Xie, Yihao | Spot ID and sample point | ||
| 4 | Lithium | Li | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 5 | Beryllium | Be | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 6 | Boron | B | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 7 | Sodium | Na | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 8 | Magnesium carbonate | MgCO3 | % | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 9 | Aluminium | Al | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 10 | Silicon | Si | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 11 | Phosphorus | P | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 12 | Potassium | K | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 13 | Calcium carbonate | CaCO3 | % | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 14 | Scandium | Sc | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 15 | Titanium | Ti | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 16 | Vanadium | V | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 17 | Chromium | Cr | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 18 | Manganese | Mn | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 19 | Iron | Fe | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 20 | Cobalt | Co | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 21 | Nickel | Ni | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 22 | Copper | Cu | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 23 | Zinc | Zn | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 24 | Gallium | Ga | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 25 | Germanium | Ge | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 26 | Arsenic | As | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 27 | Rubidium | Rb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 28 | Strontium | Sr | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 29 | Yttrium | Y | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 30 | Zirconium | Zr | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 31 | Niobium | Nb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 32 | Molybdenum | Mo | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 33 | Silver | Ag | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 34 | Cadmium | Cd | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 35 | Tin | Sn | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 36 | Antimony | Sb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 37 | Caesium | Cs | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 38 | Barium | Ba | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 39 | Lanthanum | La | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 40 | Cerium | Ce | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 41 | Praseodymium | Pr | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 42 | Neodymium | Nd | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 43 | Samarium | Sm | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 44 | Europium | Eu | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 45 | Gadolinium | Gd | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 46 | Terbium | Tb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 47 | Dysprosium | Dy | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 48 | Holmium | Ho | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 49 | Erbium | Er | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 50 | Thulium | Tm | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 51 | Ytterbium | Yb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 52 | Lutetium | Lu | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 53 | Hafnium | Hf | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 54 | Tantalum | Ta | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 55 | Tungsten | W | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 56 | Mercury | Hg | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 57 | Lead | Pb | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 58 | Bismuth | Bi | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 59 | Thorium | Th | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 | |
| 60 | Uranium | U | µg/g | Xie, Yihao | Laser ablation system (LA), Coherent Inc., Geolas HD, coupled to inductively coupled plasma mass spectrometer (ICP-MS), Agilent Technologies, 7900 |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1770 data points
