Ruchkin, Maksim; Lorenz, Sebastian; Adolph, Marie-Luise; Haberzettl, Torsten (2026): Grain-size distribution of sediment core HoVie06 from Schweriner See, NE Germany [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.992924 (DOI registration in progress), In: Ruchkin, M et al. (2026): Laser diffraction grain-size data of Late Glacial to present sediment cores from Schweriner See, NE Germany [dataset publication series]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.992930 (DOI registration in progress)
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2026-03-13
Related to:
Ruchkin, Maksim; Lorenz, Sebastian; Adolph, Marie-Luise; Haberzettl, Torsten (preprint): Using portable luminescence profiling to refine 14C and OSL-based chronologies of lacustrine littoral sedimentary sequences: a case study from Schweriner See (NE Germany). https://doi.org/10.2139/ssrn.6271021
Funding:
German Research Foundation (DFG), grant/award no. 451683760: Late Pleistocene to Holocene climate variations and anthropogenic changes in the North German Plain inferred from lake and peat sediments from Schweriner See
Coverage:
Latitude: 53.773528 * Longitude: 11.485361
Minimum DEPTH, sediment/rock: 0.290 m * Maximum DEPTH, sediment/rock: 3.990 m
Event(s):
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | DEPTH, sediment/rock | Depth sed | m | Ruchkin, Maksim | Geocode | |
| 2 | Depth, top/min | Depth top | m | Ruchkin, Maksim | ||
| 3 | Depth, bottom/max | Depth bot | m | Ruchkin, Maksim | ||
| 4 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.08-0.084µm_vol% |
| 5 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.084-0.093µm_vol% |
| 6 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.093-0.102µm_vol% |
| 7 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.102-0.112µm_vol% |
| 8 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.112-0.122µm_vol% |
| 9 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.122-0.134µm_vol% |
| 10 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.134-0.148µm_vol% |
| 11 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.148-0.162µm_vol% |
| 12 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.162-0.178µm_vol% |
| 13 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.178-0.195µm_vol% |
| 14 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.195-0.214µm_vol% |
| 15 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.214-0.235µm_vol% |
| 16 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.235-0.258µm_vol% |
| 17 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.258-0.284µm_vol% |
| 18 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.284-0.311µm_vol% |
| 19 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.311-0.342µm_vol% |
| 20 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.342-0.375µm_vol% |
| 21 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.375-0.412µm_vol% |
| 22 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.412-0.452µm_vol% |
| 23 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.452-0.496µm_vol% |
| 24 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.496-0.545µm_vol% |
| 25 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.545-0.598µm_vol% |
| 26 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.598-0.657µm_vol% |
| 27 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.657-0.721µm_vol% |
| 28 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.721-0.791µm_vol% |
| 29 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.791-0.869µm_vol% |
| 30 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.869-0.953µm_vol% |
| 31 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 0.953-1.047µm_vol% |
| 32 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1.047-1.149µm_vol% |
| 33 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1.149-1.261µm_vol% |
| 34 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1.261-1.385µm_vol% |
| 35 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1.385-1.52µm_vol% |
| 36 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1.52-1.669µm_vol% |
| 37 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1.669-1.832µm_vol% |
| 38 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1.832-2.01µm_vol% |
| 39 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 2.01-2.207µm_vol% |
| 40 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 2.207-2.423µm_vol% |
| 41 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 2.423-2.66µm_vol% |
| 42 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 2.66-2.92µm_vol% |
| 43 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 2.92-3.206µm_vol% |
| 44 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 3.206-3.519µm_vol% |
| 45 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 3.519-3.862µm_vol% |
| 46 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 3.862-4.241µm_vol% |
| 47 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 4.241-4.656µm_vol% |
| 48 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 4.656-5.111µm_vol% |
| 49 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 5.111-5.611µm_vol% |
| 50 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 5.611-6.158µm_vol% |
| 51 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 6.158-6.761µm_vol% |
| 52 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 6.761-7.421µm_vol% |
| 53 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 7.421-8.147µm_vol% |
| 54 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 8.147-8.944µm_vol% |
| 55 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 8.944-9.819µm_vol% |
| 56 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 9.819-10.78µm_vol% |
| 57 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 10.78-11.83µm_vol% |
| 58 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 11.83-12.99µm_vol% |
| 59 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 12.99-14.26µm_vol% |
| 60 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 14.26-15.65µm_vol% |
| 61 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 15.65-17.17µm_vol% |
| 62 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 17.17-18.86µm_vol% |
| 63 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 18.86-20.7µm_vol% |
| 64 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 20.7-22.73µm_vol% |
| 65 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 22.73-24.95µm_vol% |
| 66 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 24.95-27.38µm_vol% |
| 67 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 27.38-30.07µm_vol% |
| 68 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 30.07-33µm_vol% |
| 69 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 33-36.24µm_vol% |
| 70 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 36.24-39.77µm_vol% |
| 71 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 39.77-43.66µm_vol% |
| 72 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 43.66-47.93µm_vol% |
| 73 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 47.93-52.63µm_vol% |
| 74 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 52.63-57.77µm_vol% |
| 75 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 57.77-63.41µm_vol% |
| 76 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 63.41-69.62µm_vol% |
| 77 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 69.62-76.43µm_vol% |
| 78 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 76.43-83.9µm_vol% |
| 79 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 83.9-92.09µm_vol% |
| 80 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 92.09-101.1µm_vol% |
| 81 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 101.1-111µm_vol% |
| 82 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 111-121.8µm_vol% |
| 83 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 121.8-133.7µm_vol% |
| 84 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 133.7-146.8µm_vol% |
| 85 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 146.8-161.2µm_vol% |
| 86 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 161.2-176.8µm_vol% |
| 87 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 176.8-194.2µm_vol% |
| 88 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 194.2-213.2µm_vol% |
| 89 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 213.2-234.1µm_vol% |
| 90 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 234.1-256.8µm_vol% |
| 91 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 256.8-282.1µm_vol% |
| 92 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 282.1-309.6µm_vol% |
| 93 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 309.6-339.8µm_vol% |
| 94 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 339.8-373.1µm_vol% |
| 95 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 373.1-409.6µm_vol% |
| 96 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 409.6-449.7µm_vol% |
| 97 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 449.7-493.6µm_vol% |
| 98 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 493.6-541.9µm_vol% |
| 99 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 541.9-594.9µm_vol% |
| 100 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 594.9-653µm_vol% |
| 101 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 653-716.9µm_vol% |
| 102 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 716.9-786.9µm_vol% |
| 103 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 786.9-863.9µm_vol% |
| 104 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 863.9-948.2µm_vol% |
| 105 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 948.2-1041µm_vol% |
| 106 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1041-1143µm_vol% |
| 107 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1143-1255µm_vol% |
| 108 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1255-1377µm_vol% |
| 109 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1377-1512µm_vol% |
| 110 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1512-1660µm_vol% |
| 111 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1660-1822µm_vol% |
| 112 | Size fraction | Size fraction | % | Ruchkin, Maksim | Laser Particle Analyser, Fritsch GmbH, Analysette 22 MicroTec plus [0.08–2000 μm] | 1822-2000µm_vol% |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
17427 data points
Download Data
View dataset as HTML (shows only first 2000 rows)
