Maiga, Ynoussa; Compaore, Cheick Omar Tidiane; Sawadogo, Mamady; Nagalo, Issa; Diallo, Martine; Sossou, Seyram; Some, Hermann; Mihelcic, James R; Ouattara, Aboubakar Sidiki: Greywater data from rural household of Sahelian region (Noungou, Koubri, Burkina Faso) and its treatment by a horizontal constructed wetland [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.966066 (dataset in review)
Abstract:
Mixed greywater (laundry, dishwashing and shower) was collected from a rural household of Noungou, Burkina Faso. The collected greywater was treated in situ through a horizontal constructed wetland. The treatment system is a subsurface horizontal flow wetland with an upstream pre-treatment step. The planted section is semi-underground and made of concrete and planted with Chrysopogon zizanioides. The treated greywater is collected in an underground storage reservoir. Once a week, the raw greywater and treated samples from each section were collected for analysis. The samples were collected in sterile 500 ml glass bottles for microbiological analysis and 1000 ml plastic bottles for physico-chemical analyses. Physico-chemical parameters such as pH, electrical conductivity (EC), temperature (T, °C), and dissolved oxygen (DO) were measured directly from the influent and effluent using a portable pH/EC/TDS/temperature meter (Hanna Instruments, Romania) and Oxi 3310 (WTW Germany GmbH) (Clesceri et al., 1999). The five-day biochemical oxygen demand (BOD5), chemical oxygen demand (COD), suspended solids (SS), nitrate (NO₃⁻), ammonium (NH₄⁺), orthophosphate (PO₄³⁻) were determined according to the Standard Methods (Clesceri et al., 1999). Fecal coliforms, Esherichia coli, and enterococci were used as fecal indicators to evaluate the removal of microorganisms. The spread plate method and Chromocult Coliform Agar ES medium (Merck KGaA, Germany) were used to evaluate fecal coliform and E. coli (44 °C for 24 h), while Slanetz and Barthley agar medium (Liofilchem srl, Italy) (37 °C for 48 h) was used for enterococci (Clesceri et al., 1999).
References:
Funding:
National Academies of Sciences, Engineering, and Medicine, grant/award no. AID-OAA-A-11-0001: Increasing access to sanitation services integrated with resource recovery in rural Burkina Faso
Coverage:
Latitude: 12.201944 * Longitude: -1.308611
Date/Time Start: 2022-06-09T00:00:00 * Date/Time End: 2022-07-29T23:59:59
Minimum Elevation: 281.0 m * Maximum Elevation: 281.0 m
Event(s):
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Event label | Event | Maiga, Ynoussa | |||
2 | Latitude of event | Latitude | Maiga, Ynoussa | |||
3 | Longitude of event | Longitude | Maiga, Ynoussa | |||
4 | Type of study | Study type | Maiga, Ynoussa | |||
5 | Sampling date/time, experiment | Date/time sampling exp | Maiga, Ynoussa | |||
6 | Site | Site | Maiga, Ynoussa | |||
7 | Area/locality | Area | Maiga, Ynoussa | |||
8 | Sample type | Samp type | Maiga, Ynoussa | |||
9 | pH | pH | Maiga, Ynoussa | Portable water quality meter (Hanna Instruments) | ||
10 | Temperature, water | Temp | °C | Maiga, Ynoussa | Portable water quality meter (Hanna Instruments) | |
11 | Oxygen, dissolved | DO | mg/l | Maiga, Ynoussa | Dissolved Oxygen Meter, WTW, Oxi 3310 | |
12 | Conductivity | Cond | mS/cm | Maiga, Ynoussa | Portable water quality meter (Hanna Instruments) | Electrical conductivity (EC) |
13 | Nitrate | [NO3]- | mg/l | Maiga, Ynoussa | Standard Methods for the Examination of Water and Waste Water (Clesceri et al., 1999) | |
14 | Ammonium | [NH4]+ | mg/l | Maiga, Ynoussa | Standard Methods for the Examination of Water and Waste Water (Clesceri et al., 1999) | |
15 | Phosphate | [PO4]3- | mg/l | Maiga, Ynoussa | Standard Methods for the Examination of Water and Waste Water (Clesceri et al., 1999) | Orthophosphate |
16 | Suspended solids, total | TSS | mg/l | Maiga, Ynoussa | Standard Methods for the Examination of Water and Waste Water (Clesceri et al., 1999) | |
17 | Chemical oxygen demand | COD | mg/l | Maiga, Ynoussa | Standard Methods for the Examination of Water and Waste Water (Clesceri et al., 1999) | |
18 | Biological oxygen demand | BOD | mg/l | Maiga, Ynoussa | Standard Methods for the Examination of Water and Waste Water (Clesceri et al., 1999) | Five-day (BOD5) |
19 | Fecal coliforms | Coli Fec | log10 CFU/100 ml | Maiga, Ynoussa | Standard Methods for the Examination of Water and Waste Water (Clesceri et al., 1999) | |
20 | Escherichia coli | E. coli | log10 CFU/100 ml | Maiga, Ynoussa | Standard Methods for the Examination of Water and Waste Water (Clesceri et al., 1999) | |
21 | Enterococci | Enterococci | log10 CFU/100 ml | Maiga, Ynoussa | Standard Methods for the Examination of Water and Waste Water (Clesceri et al., 1999) |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size: