Abstract:
Selected multicorer cores and ROV push cores (IP21_021-17, IP21_021-18, IP21_061, IP21_061-19, IP21_061-20) of R/V Island Pride cruise IP21 were scanned using a Philips Brilliance iCT Elite 256 computer tomograph (CT) at the hospital Klinikum Bremen-Mitte, with an X- ray source voltage of 120 kV and a current of 300 mA. The CT image stacks have a physical resolution of 0.293 mm in the x and y directions and 0.625 mm resolution in the z direction (collimation; 0.3 mm reconstruction interval). Images were reconstructed using the filtered Back Projection (fBP) mode and a bone kernel (YB (Enhanced)).
The data were processed with the ZIB edition of the Amira software (version 2019.51; Stalling et al., 2005; http://amira.zib.de). Within Amira, the core liners, including about 2 mm of the core rims, were deleted from the data set. Mangan nodules with diameters >~1 mm, open bioturbation traces, an unidentified organism, the natural bioturbated and surficial homogenised sediment were segmented by a marker-based watershed segmentation and visualized in 3D. Subsequently, the sediment components were quantified (MaterialStatistics module; volume per slice) and the mean and standard deviation of the sediment x-ray attenuation (MaterialStatistics module; statistics per slice per label; to avoid marginal averaging effects the sediment label was reduced by three voxels) were determined.
Keyword(s):
Computed Tomography; Mining impact; Sediment characterisation
Further details:
Stalling, Detlev; Westerhoff, Malte; Hege, Hans-Christian (2005): Amira: A Highly Interactive System for Visual Data Analysis. In: Hansen, C.D., Johnson, C.R. (Eds.), Visualization Handbook. Butterworth-Heinemann, Burlington, 749-767, https://doi.org/10.1016/B978-012387582-2/50040-X
Funding:
Federal Ministry of Education and Research (BMBF), grant/award no. 03F0812A: JPI-O MiningImpact: Monitoringkonzepte für einen Manganknollenabbau in der Tiefsee
Coverage:
Latitude: 11.929400 * Longitude: -117.020433
Date/Time Start: 2021-05-03T08:58:00 * Date/Time End: 2021-05-03T08:58:00
Minimum DEPTH, sediment/rock: 0.0000 m * Maximum DEPTH, sediment/rock: 0.2319 m
Event(s):
IP21_052MUC * Latitude: 11.929400 * Longitude: -117.020433 * Date/Time: 2021-05-03T08:58:00 * Elevation: -4086.0 m * Location: North Pacific Ocean * Campaign: IP21 (MANGAN21) * Basis: Island Pride * Method/Device: MultiCorer (MUC)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1File contentContentTitschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
2Binary ObjectBinaryTitschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
3Number of sliceNo slice#Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
4DEPTH, sediment/rockDepth sedmTitschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256Geocode
5Manganese nodules, volumeMn nodulesmm3Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
6Sediment, homogenized upper layer, volumeUpper layermm3Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
7Sediment, bioturbated lower layer, volumeLower layermm3Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
8Bioturbation, volumeBioturbation volmm3Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
9BioturbationBioturb%Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256vol%
10Manganese nodules, relative volumeMn nodules%Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256vol%
11Sediment, homogenized upper layer, relative volumeUpper layer%Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256vol%
12Sediment, bioturbated lower layer, relative volumeLower layer%Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256vol%
13X-ray attenuation, matrix sediment, meanX-RAY attenuation matrix sed meanHUTitschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
14X-ray attenuation, matrix sediment, standard deviationX-RAY attenuation matrix sed std dev±Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
15Number of voxels, matrix sedimentNo voxels matrix sed#Titschack, JürgenComputer tomograph (CT) Philips Brilliance iCT Elite 256
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
9292 data points

Download Data (login required; moratorium until 2024-06-23)

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)