Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Martinez, Andres; Hua, Jason; Haque, Ezazul; Thorne, Peter; Hornbuckle, Keri C (2022): Concentrations of individual polychlorinated biphenyl congeners from Standard Reference Material (SRM) 1944 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.941883, In: Martinez, A et al. (2022): Dataset of concentrations of individual polychlorinated biphenyl congeners and total organic carbon in soils from East Chicago, Indiana, USA in 2017/2018 [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.941894

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX Citation

Abstract:
Five Standard Reference Material 1944, New York, New Jersey Waterway sediment (SRM 1944, National Institutes of Standards and Testing) were extracted, cleaned and quantified using the same method for soils. Gas chromatography (GC) in tandem with Mass Spectrometry GC-MS/MS (Agilent 7000) in multiple reaction monitoring (MRM) mode was used to quantify all 28 individual or coeluting certified congeners. The GC was equipped with a Supelco SBP-Octyl capillary column (30 m × 0.25 mm ID, 0.25 mm film thicknesses) with helium as carrier gas.
Keyword(s):
PCB congeners; Soil; TOC
Supplement to:
Martinez, Andres; Hua, Jason; Haque, Ezazul; Hornbuckle, Keri C; Thorne, Peter (2022): Occurrence and spatial distribution of individual polychlorinated biphenyl congeners in residential soils from East Chicago, southwest Lake Michigan. Science of the Total Environment, 850, 157705, https://doi.org/10.1016/j.scitotenv.2022.157705
Funding:
National Institute of Environmental Health Sciences (NIEHS), grant/award no. P42ES013661: Iowa Superfund Research Program
National Institutes of Health (NIH), grant/award no. P30ES005605: University of Iowa's Environmental Health Sciences Research Center
Comment:
Selected PCB congener in sediment Standard Reference Material (R) 1944 using GC-MS/MS:
* The congeners with an asterisk indicate the main congener identified by the reference material.
* Our analytical method yields a different congener separation.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Sample code/labelSample labelMartinez, Andres
2Method commentMethod commMartinez, Andres
3Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB8
4Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB18*+30
5Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB20+28*
6Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB31
7Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB44*+47+65
8Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB49*+69
9Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB52
10Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB66
11Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB87*+125
12Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB95
13Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB99
14Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB90+101*+113
15Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB105
16Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB110
17Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB118
18Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB129+138*+163
19Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB147+149*
20Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB135+151*
21Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB153*+168
22Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB156*+157
23Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB170
24Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB180*+193
25Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB183
26Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB187
27Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB194
28Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB195
29Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB206
30Polychlorinated biphenyl, per unit sediment dry massPCB/sed dmng/gMartinez, Andrestandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM)PCB209
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
150 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML