Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Tejada, Maria Luisa G; Brumsack, Hans-Jürgen; Schnetger, Bernhard (2020): X-Ray Fluorescence Spectrometry Data for IODP Hole 369-U1513D [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.924535

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2020-11-09DOI registered: 2020-11-18

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Abstract:
Bulk rock composition analysis was conducted by X-Ray Fluorescence spectrometry (WD-XRF) using AXIOS Plus (Panalytical) at University of Oldenburg on shipboard residual sample powders analyzed by ICP-AES [Huber et al., 2019]. Borate glass beads were prepared from the sample powder using di-lithium tetraborate as a flux (700 mg sample, 4.2 g flux). Calibration of the XRF instrument is based on 52 international reference samples and in-house standards. Precision was determined from the pooled standard deviation of several duplicates and is better than 3% for major elements and better than 5% for trace elements when concentration levels are above the limit of quantitation. Accuracy was checked by analyzing international and in-house reference samples that are not included in the calibration and was better than 7% for all elements above the limit of quantitation. Results between XRF and ICP-AES analysis are generally in excellent agreement, except for elements affected by incomplete dissolution in borate digestion, especially Cr, and low-abundance elements like Rb and Nb that were not measured well by ICP-AES.
Keyword(s):
IODP Expedition 369 Site U1513 Hole D; Naturaliste Plateau basalts and volcaniclastic flows
Supplement to:
Harry, Dennis L; Tejada, Maria Luisa G; Lee, Eun Young; Wolfgring, Erik; Wainman, Carmine Christopher; Brumsack, Hans-Jürgen; Schnetger, Bernhard; Kimura, Jun-Ichi; Riquier, Laurent; Borissova, Irina; Hobbs, Richard W; Jiang, Tao; Li, Yong-Xiang; Maritati, Alessandro; Martinez, Mathieu; Richter, Carl; Tagliaro, Gabriel; White, Lloyd T (2020): Evolution of the Southwest Australian Rifted Continental Margin During Breakup of East Gondwana: Results from IODP Expedition 369. Geochemistry, Geophysics, Geosystems, https://doi.org/10.1029/2020GC009144
Coverage:
Latitude: -33.793470 * Longitude: 112.485560
Date/Time Start: 2017-10-24T08:45:00 * Date/Time End: 2017-11-01T17:30:00
Minimum DEPTH, sediment/rock: 693.54 m * Maximum DEPTH, sediment/rock: 756.67 m
Event(s):
369-U1513D * Latitude: -33.793470 * Longitude: 112.485560 * Date/Time Start: 2017-10-24T08:45:00 * Date/Time End: 2017-11-01T17:30:00 * Elevation: -2789.0 m * Campaign: Exp369 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL)
Comment:
Borate glass beads were prepared from the sample powder using di-lithium tetraborate as a flux (700 mg sample, 4.2 g flux).
Calibration of the XRF instrument is based on 52 international reference samples and in-house standards. Precision was determined from the pooled standard deviation of several duplicates and is better than 3% for major elements and better than 5% for trace elements when concentration levels are above the limit of quantitation. Accuracy was checked by analyzing international and in-house reference samples that are not included in the calibration and was better than 7% for all elements above the limit of quantitation.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Sample code/labelSample labelTejada, Maria Luisa GDSDP/ODP/IODP sample designation
2DEPTH, sediment/rockDepth sedmTejada, Maria Luisa GGeocode – mbsf
3UnitUnitTejada, Maria Luisa G
4Silicon dioxideSiO2%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
5Titanium dioxideTiO2%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
6Aluminium oxideAl2O3%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
7Iron oxide, Fe2O3Fe2O3%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %, total Fe as Fe2O3
8Manganese oxideMnO%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
9Magnesium oxideMgO%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
10Calcium oxideCaO%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
11Sodium oxideNa2O%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
12Potassium oxideK2O%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
13Phosphorus pentoxideP2O5%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
14Elements, totalTotal%Tejada, Maria Luisa GX-ray fluorescence (XRF)wt. %
15Loss on ignitionLOI%Tejada, Maria Luisa GX-ray fluorescence (XRF)
16RubidiumRbmg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
17BariumBamg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
18NiobiumNbmg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
19StrontiumSrmg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
20ZirconiumZrmg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
21VanadiumVmg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
22YttriumYmg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
23GalliumGamg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
24ChromiumCrmg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
25ZincZnmg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
26CopperCumg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
27CobaltComg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
28NickelNimg/kgTejada, Maria Luisa GX-ray fluorescence (XRF)
Size:
648 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML