Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Expedition 357 Scientists (2016): Concentrations of trace elements in fluid samples from IODP Hole 357-M0073A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.869883

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Frueh-Green, Gretchen L; Orcutt, Beth N; Green, Sophie; Cotterill, Carol; Expedition 357 Scientists (2016): Atlantis Massif Serpentinization and Life. International Ocean Discovery Program Preliminary Report, International Ocean Discovery Program, https://doi.org/10.14379/iodp.pr.357.2016
Coverage:
Latitude: 30.131650 * Longitude: -42.182820
Date/Time Start: 2015-11-12T00:00:00 * Date/Time End: 2015-11-15T00:00:00
Minimum Elevation: -1430.2 m * Maximum Elevation: -1430.2 m
Event(s):
357-M0073A (AM-05A) * Latitude: 30.131650 * Longitude: -42.182820 * Date/Time: 2015-11-15T00:00:00 * Elevation: -1430.2 m * IGSN: IBCR0357EHL0001 * Location: Atlantis Massif * Campaign: Exp357 * Basis: James Cook * Comment: MeBo, CTD: 30 7.874N / 42 10.945W, 12-Nov-2015; MeBo touched steep slope, back to deck
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1CoreCoreExpedition 357 Scientists
2TypeTypeExpedition 357 Scientists
3SectionSectExpedition 357 Scientists
4DATE/TIMEDate/TimeExpedition 357 ScientistsGeocode
5Sample positionSamp posExpedition 357 ScientistsICP-OES Autosampler
6Sample IDSample IDExpedition 357 Scientists
7AluminiumAlµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 167.019
8Barium 2+Ba2+µg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 455.403
9CadmiumCdµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 228.802
10ChromiumCrµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 267.716
11IronFeµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 238.204
12LithiumLiµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 670.783
13ManganeseMnnmol/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 259.372; original unit [µg/l]
14MolybdenumMoµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 202.032
15NickelNiµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 227.021
16PhosphorusPµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000No good peak; Wavelength (nm): 177.434
17LeadPbµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 220.353
18StrontiumSrµmol/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Values too high (hence the) for this ICP, use the Varian radial analyses; Wavelength (nm): 407.771; original unit [µg/l]
19TitaniumTiµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 334.941
20VanadiumVµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 292.401
21ZincZnµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Mn interference contamination; Wavelength (nm): 213.857
22ZirconiumZrµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 343.823
Size:
40 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML