Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Expedition 357 Scientists (2016): Concentrations of trace elements in fluid samples from IODP Hole 357-M0073A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.869883

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Frueh-Green, Gretchen L; Orcutt, Beth N; Green, Sophie; Cotterill, Carol; Expedition 357 Scientists (2016): Atlantis Massif Serpentinization and Life. International Ocean Discovery Program Preliminary Report, International Ocean Discovery Program, https://doi.org/10.14379/iodp.pr.357.2016
Coverage:
Latitude: 30.131650 * Longitude: -42.182820
Date/Time Start: 2015-11-12T00:00:00 * Date/Time End: 2015-11-15T00:00:00
Minimum Elevation: -1430.2 m * Maximum Elevation: -1430.2 m
Event(s):
357-M0073A (AM-05A) * Latitude: 30.131650 * Longitude: -42.182820 * Date/Time: 2015-11-15T00:00:00 * Elevation: -1430.2 m * IGSN: IBCR0357EHL0001 * Location: Atlantis Massif * Campaign: Exp357 * Basis: James Cook * Comment: MeBo, CTD: 30 7.874N / 42 10.945W, 12-Nov-2015; MeBo touched steep slope, back to deck
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
CoreCoreExpedition 357 Scientists
TypeTypeExpedition 357 Scientists
SectionSectExpedition 357 Scientists
DATE/TIMEDate/TimeExpedition 357 ScientistsGeocode
Sample positionSamp posExpedition 357 ScientistsICP-OES Autosampler
Sample IDSample IDExpedition 357 Scientists
AluminiumAlµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 167.019
Barium 2+Ba2+µg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 455.403
CadmiumCdµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 228.802
10 ChromiumCrµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 267.716
11 IronFeµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 238.204
12 LithiumLiµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 670.783
13 ManganeseMnnmol/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 259.372; original unit [µg/l]
14 MolybdenumMoµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 202.032
15 NickelNiµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 227.021
16 PhosphorusPµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000No good peak; Wavelength (nm): 177.434
17 LeadPbµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 220.353
18 StrontiumSrµmol/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Values too high (hence the) for this ICP, use the Varian radial analyses; Wavelength (nm): 407.771; original unit [µg/l]
19 TitaniumTiµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 334.941
20 VanadiumVµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 292.401
21 ZincZnµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Mn interference contamination; Wavelength (nm): 213.857
22 ZirconiumZrµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 343.823
Size:
40 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Core

Type

Sect

Date/Time

Samp pos

Sample ID

Al [µg/l]

Ba2+ [µg/l]

Cd [µg/l]
10 
Cr [µg/l]
11 
Fe [µg/l]
12 
Li [µg/l]
13 
Mn [nmol/l]
14 
Mo [µg/l]
15 
Ni [µg/l]
16 
P [µg/l]
17 
Pb [µg/l]
18 
Sr [µmol/l]
19 
Ti [µg/l]
20 
V [µg/l]
21 
Zn [µg/l]
22 
Zr [µg/l]
IWref1CTDB12015-11-122:25226.806.631.983.666.84124.70.0046412.4052.05115.985160.645.285.253.49
IWref2SPB12015-11-152:312824.116.642.275.156.43125.20.0048211.548.7167.9010.88117.435870.653.6341.384.13