Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Walsh, Harvey Joseph; Hare, Jonathan A (2014): Particle size spectrum analysis during Maria S. Merian cruise MSM26, spring 2013 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.835330, In: Walsh, HJ; Hare, JA (2014): Mesopelagic fish abundance and particle size spectrum analysis from Maria S. Merian cruise MSM26, spring 2013 [dataset publication series]. PANGAEA, https://doi.org/10.1594/PANGAEA.835331

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
A Laser In-Situ Scattering Transmissometer (LISST) was used to collect vertical distribution data of particles from 2.5 to 500 µm in size. The LISST uses a multi-ring detector to measure scattering light of particles from a laser diode. Particles are classified into 32 log-spaced bins and the concentration of each bin is calculated as micro-liters per liter (µl/l). The instrument is rated to a depth of 300 m, and also records temperature and pressure. The sample interval was set to record every second. The LISST was attached to the LOPC frame to conduct casts and allow for particle-size comparisons between the two instruments. The LOPC is rated to a depth of 2000 m, thus a short deployment to a depth of 300 m was first conducted with both instruments. The instruments were then returned to the deck and the LISST removed via a quick release bracket so deep LOPC casts could be continued at a station. Raw LISST size-spectrum data is presented as concentrations for each of the 32 size bins for every second of the cast.
Funding:
Seventh Framework Programme (FP7), grant/award no. 264933: Basin Scale Analysis, Synthesis and Integration
Coverage:
Median Latitude: 59.634600 * Median Longitude: -35.225956 * South-bound Latitude: 53.358000 * West-bound Longitude: -55.979000 * North-bound Latitude: 62.857000 * East-bound Longitude: -10.863000
Date/Time Start: 2013-03-25T18:28:00 * Date/Time End: 2013-04-14T02:51:00
Minimum Elevation: -3810.9 m * Maximum Elevation: -750.0 m
Event(s):
MSM26_126-10 * Latitude: 61.448000 * Longitude: -10.863000 * Date/Time: 2013-03-25T18:28:00 * Elevation: -1225.0 m * Location: North Atlantic Ocean * Campaign: MSM26 * Basis: Maria S. Merian * Method/Device: Laser Optical Plankton Counter with CTD (LOPC-CTD)
MSM26_127-13 * Latitude: 62.821000 * Longitude: -21.362000 * Date/Time: 2013-03-28T08:24:00 * Elevation: -1149.0 m * Location: North Atlantic Ocean * Campaign: MSM26 * Basis: Maria S. Merian * Method/Device: Laser Optical Plankton Counter with CTD (LOPC-CTD)
MSM26_127-22 * Latitude: 62.857000 * Longitude: -21.441000 * Date/Time: 2013-03-28T23:27:00 * Elevation: -1136.0 m * Location: North Atlantic Ocean * Campaign: MSM26 * Basis: Maria S. Merian * Method/Device: Laser Optical Plankton Counter with CTD (LOPC-CTD) * Comment: rope length max. 300m /ARW
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEvent
2Time of dayTime of dayWalsh, Harvey Josephof sampling
3Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 2.72 µm, original unit = µl/l
4Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 3.2 µm, original unit = µl/l
5Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 3.78 µm, original unit = µl/l
6Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 4.46 µm, original unit = µl/l
7Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 5.27 µm, original unit = µl/l
8Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 6.21 µm, original unit = µl/l
9Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 7.33 µm, original unit = µl/l
10Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 8.65 µm, original unit = µl/l
11Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 10.2 µm, original unit = µl/l
12Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 12.1 µm, original unit = µl/l
13Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 14.2 µm, original unit = µl/l
14Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 16.8 µm, original unit = µl/l
15Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 19.8 µm, original unit = µl/l
16Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 23.4 µm, original unit = µl/l
17Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 27.6 µm, original unit = µl/l
18Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 32.5 µm, original unit = µl/l
19Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 38.4 µm, original unit = µl/l
20Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 45.3 µm, original unit = µl/l
21Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 53.5 µm, original unit = µl/l
22Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 63.1 µm, original unit = µl/l
23Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 74.5 µm, original unit = µl/l
24Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 87.9 µm, original unit = µl/l
25Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 104 µm, original unit = µl/l
26Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 122 µm, original unit = µl/l
27Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 144 µm, original unit = µl/l
28Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 170 µm, original unit = µl/l
29Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 201 µm, original unit = µl/l
30Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 237 µm, original unit = µl/l
31Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 280 µm, original unit = µl/l
32Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 331 µm, original unit = µl/l
33Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 390 µm, original unit = µl/l
34Particle volumePart volmg/kgWalsh, Harvey JosephLaser In-Situ Scattering Transmissometer, LISST-100X, SEQUOIA Scientific, Inc.median particle size = 460 µm, original unit = µl/l
35Pressure, stressPMPaWalsh, Harvey Joseph
36Temperature, technicalT tech°CWalsh, Harvey Joseph
37Time of dayTime of dayWalsh, Harvey Joseph
38Day of the yearDOYdayWalsh, Harvey Joseph
Size:
569097 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)