Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Schönfeld, Joachim: Color measurements on sediment core MD99-2336 [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.56116 (unpublished dataset)

Show MapGoogle Earth

Coverage:
Latitude: 36.716667 * Longitude: -8.258833
Date/Time Start: 1999-09-14T16:30:00 * Date/Time End: 1999-09-14T16:30:00
Minimum DEPTH, sediment/rock: 0.01500 m * Maximum DEPTH, sediment/rock: 19.52000 m
Event(s):
MD99-2336 (91) * Latitude: 36.716667 * Longitude: -8.258833 * Date/Time: 1999-09-14T16:30:00 * Elevation: -690.0 m * Penetration: 23 m * Recovery: 19.56 m * Location: Gulf of Cádiz, Atlantic Ocean * Campaign: MD114 (IMAGES V) * Basis: Marion Dufresne (1995) * Method/Device: Calypso Corer (CALYPSO) * Comment: segments I to XIII. last segment is 156 cm long. Site is located on an incipient sediment drift along the northern MOW pathway at depths between 550 and 700 m where the main flow is concentrated today. High sedimentation rates between 20 and 40 cm / kyrs reflect current induced sediment accumulation on the lee side of that drift and allow paleoceanographic studies with high resolution. At the location of site MD99-2336, a conventional gravity core of 2.66 m was taken during R/V METEOR cruise M39/1 in April 1997 (1). This record goes back to the last Glacial Maximum.
Comment:
Cores opened directly before measurements, therefore the data is considered shipboard data
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, sediment/rockDepth sedmGeocode
2Color, L*, lightnessL*Schönfeld, JoachimSpectrophotometer Minolta CR-300
3Color, a*a*Schönfeld, JoachimSpectrophotometer Minolta CR-300
4Color, b*b*Schönfeld, JoachimSpectrophotometer Minolta CR-300
5Color code HLS-systemColor HLSSchönfeld, JoachimMunsell Color System (1994)
6Color reflectance at 400 nmColor 400%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
7Color reflectance at 410 nmColor 410%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
8Color reflectance at 420 nmColor 420%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
9Color reflectance at 430 nmColor 430%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
10Color reflectance at 440 nmColor 440%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
11Color reflectance at 450 nmColor 450%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
12Color reflectance at 460 nmColor 460%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
13Color reflectance at 470 nmColor 470%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
14Color reflectance at 480 nmColor 480%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
15Color reflectance at 490 nmColor 490%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
16Color reflectance at 500 nmColor 500%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
17Color reflectance at 510 nmColor 510%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
18Color reflectance at 520 nmColor 520%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
19Color reflectance at 530 nmColor 530%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
20Color reflectance at 540 nmColor 540%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
21Color reflectance at 550 nmColor 550%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
22Color reflectance at 560 nmColor 560%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
23Color reflectance at 570 nmColor 570%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
24Color reflectance at 580 nmColor 580%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
25Color reflectance at 590 nmColor 590%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
26Color reflectance at 600 nmColor 600%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
27Color reflectance at 610 nmColor 610%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
28Color reflectance at 620 nmColor 620%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
29Color reflectance at 630 nmColor 630%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
30Color reflectance at 640 nmColor 640%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
31Color reflectance at 650 nmColor 650%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
32Color reflectance at 660 nmColor 660%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
33Color reflectance at 670 nmColor 670%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
34Color reflectance at 680 nmColor 680%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
35Color reflectance at 690 nmColor 690%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
36Color reflectance at 700 nmColor 700%Schönfeld, JoachimSpectrophotometer Minolta CM-2002
37Color, XXSchönfeld, JoachimSpectrophotometer Minolta CM-2002
38Color, YYSchönfeld, JoachimSpectrophotometer Minolta CM-2002
39Color, ZZSchönfeld, JoachimSpectrophotometer Minolta CM-2002
Size:
36648 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)