Massari, Francesco; Fellin, Maria Giuditta; Stefani, Cristina; Enkelmann, Eva; Dieni, Iginio; Sanchetti, Stefano (2026): Detrital zircon geochronologic analysis of the Lanaittu Sandstone in Eastern Sardinia, Italy [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.995329
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2026-06-23 • DOI registered: 2026-06-23
Abstract:
The data set comprises the results of the U-Pb dating analysis of detrital zircons from two samples (177-1 and 177-2) from the middle-upper Campanian turbiditic Lanaittu Sandstone. The samples were cored along a geognostic borehole in the Lanaittu valley in eastern Sardinia. The analysis was performed following the procedure as in Pickering et al. (2020) and Härtel et al. (2026) using a Resonetics Resolution LR 193 nm excimer laser attached to an inductively coupled plasma mass spectrometers Agilent 7700. The laser ablation system was equipped with a M50 Cell, which was flushed with a helium gas flow of 700 L/min and nitrogen gas flow of 4 L/min. The ablation spot size was set to 33 µm, the ablation time to 20 s, and the repetition rate to 5 Hz. The background was measured for 20 s. The same system setting was used to measure both the validation references and the samples.
Supplement to:
Massari, Francesco; Fellin, Maria Giuditta; Stefani, Cristina; Enkelmann, Eva; Dieni, Iginio; Sanchetti, Stefano (accepted): Exhumed eo-Alpine high-pressure rocks fed Campanian turbidites in eastern Sardinia. Geochemistry, Geophysics, Geosystems
References:
Härtel, Birk; Enkelmann, Eva; Whelan, Elisha (2026): Combined zircon U/Pb-(U-Th)/He-Raman dating. Chemical Geology, 713, 123435, https://doi.org/10.1016/j.chemgeo.2026.123435
Pickering, Julia; Matthews, William A; Enkelmann, Eva; Guest, Bernard; Sykes, Chris; Koblinger, Brett M (2020): Laser ablation (U-Th-Sm)/He dating of detrital apatite. Chemical Geology, 548, 119683, https://doi.org/10.1016/j.chemgeo.2020.119683
Funding:
Coverage:
Latitude: 40.259200 * Longitude: 9.501400
Date/Time Start: 1994-01-01T00:00:00 * Date/Time End: 1994-01-01T00:00:00
Event(s):
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | Event label | Event | Enkelmann, Eva | |||
| 2 | Sample code/label | Sample label | Enkelmann, Eva | Uranium-Lead Laser Ablation Label | ||
| 3 | Sample code/label 2 | Sample label 2 | Enkelmann, Eva | Spot number | ||
| 4 | Lead-207 | 207Pb | cps | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | |
| 5 | Lead-206 | 206Pb | cps | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | |
| 6 | Uranium | U | µg/g | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Concentration uncertainty about 5% |
| 7 | Uranium/Thorium ratio | U/Th | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | ||
| 8 | Uranium-238/Lead-206 ratio | 238U/206Pb | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Data not corrected for common lead | |
| 9 | Uranium-238/Lead-206 ratio, uncertainty, relative | 238U/206Pb unc rel | % | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Includes all random uncertainties (sm, ε), represents two standard deviations |
| 10 | Lead-207/Lead-206 ratio | 207Pb/206Pb | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Data not corrected for common lead | |
| 11 | Lead-207/Lead-206 ratio, uncertainty, relative | 207Pb/206Pb unc rel | % | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Includes all random uncertainties (sm, ε), represents two standard deviations |
| 12 | Lead-207/Uranium-235 ratio | 207Pb/235U | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Data not corrected for common lead | |
| 13 | Lead-207/Uranium-235 ratio, uncertainty, relative | 207Pb/235U unc rel | % | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Includes all random uncertainties (sm, ε), represents two standard deviations |
| 14 | Lead-206/Uranium-238 ratio | 206Pb/238U | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Data not corrected for common lead | |
| 15 | Lead-206/Uranium-238 ratio, uncertainty, relative | 206Pb/238U unc rel | % | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Includes all random uncertainties (sm, ε), represents two standard deviations |
| 16 | Correlation coefficient, isotope ratio error | Rho | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Data not corrected for common lead | |
| 17 | Age, mineral | Age mineral | Ma | Enkelmann, Eva | Age, Lead-207/Lead-206 | |
| 18 | Age, mineral, uncertainty | Age mineral unc | ± | Enkelmann, Eva | Age, Lead-207/Lead-206 | Includes all random uncertainties (sm, ε), represents two standard deviations |
| 19 | Age, mineral, uncertainty | Age mineral unc | ± | Enkelmann, Eva | Age, Lead-207/Lead-206 | Inlcudes all random and systematic uncertainties (sm, ε, ε', sy, λ), represents two standard deviations |
| 20 | Age, mineral | Age mineral | Ma | Enkelmann, Eva | Age, Lead-206/Uranium-238 | |
| 21 | Age, mineral, uncertainty | Age mineral unc | ± | Enkelmann, Eva | Age, Lead-206/Uranium-238 | Includes all random uncertainties (sm, ε), represents two standard deviations |
| 22 | Age, mineral, uncertainty | Age mineral unc | ± | Enkelmann, Eva | Age, Lead-206/Uranium-238 | Inlcudes all random and systematic uncertainties (sm, ε, ε', sy, λ), represents two standard deviations |
| 23 | Age, mineral | Age mineral | Ma | Enkelmann, Eva | Age, Lead-207/Lead-235 | |
| 24 | Age, mineral, uncertainty | Age mineral unc | ± | Enkelmann, Eva | Age, Lead-207/Lead-235 | Includes all random uncertainties (sm, ε), represents two standard deviations |
| 25 | Age, mineral, uncertainty | Age mineral unc | ± | Enkelmann, Eva | Age, Lead-207/Lead-235 | Inlcudes all random and systematic uncertainties (sm, ε, ε', sy, λ), represents two standard deviations |
| 26 | Age, mineral | Age mineral | Ma | Enkelmann, Eva | Concordia age | Concordance calculated as (206Pb/238U date/207Pb-206Pb Age)*100 |
| 27 | Age, mineral, uncertainty | Age mineral unc | ± | Enkelmann, Eva | Concordia age | Inlcudes all random and systematic uncertainties (sm, ε, ε', sy, λ), represents two standard deviations |
| 28 | Probability | Prob | % | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | |
| 29 | Concordance | Conc | % | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Concordance calculated as (206Pb/238U date/207Pb-206Pb Age)*100 |
| 30 | Comment | Comment | Enkelmann, Eva | CL: analysis affected by common lead; SL: sloping 6/8 or 7/6 date, suggestive of date heterogeneity; | ||
| 31 | Age, mineral | Age mineral | Ma | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Accepted dates have probability of concordance >1% |
| 32 | Age, mineral, uncertainty | Age mineral unc | ± | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Includes all random uncertainties (sm, ε), represents two standard deviations |
| 33 | Age, mineral, uncertainty | Age mineral unc | ± | Enkelmann, Eva | Laser ablation system, Resonetics Resolution LR 193 nm [cell M50]; coupled with inductively coupled plasma mass spectrometer, Agilent, 7700 | Inlcudes all random and systematic uncertainties (sm, ε, ε', sy, λ), represents two standard deviations |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
7199 data points
Download Data
View dataset as HTML (shows only first 2000 rows)
