Muthre, Mishelle; Naruse, Hajime; Proust, Jean-Noël; Pizer, Charlotte; Huang, Jyh-Jaan Steven; Ikehara, Ken; Strasser, Michael (2026): Grain-size distribution of from different Holes of IODP Expedition 386 [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.988692 (DOI registration in progress)
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2026-01-12
Abstract:
This dataset provides grain-size distributions for 278 sediment samples from 11 sediment cores targeting four event beds - Event Bed 1 (CE 2011 Tohoku-Oki), Event Bed 2 (CE 1456 Kyōtoku), Event Bed 3 (CE 869 Jogan), and Event Bed 4 (2.3 ka) - as well as intervening deposits (other event beds and hemipelagic background sediment) from four sites in three trench basins: Basins S3 (site M0091), C1 (site M0090), and C2 (sites M0089 and M0083). These grain-size data were used to build a facies sequence that is applied to identify and interpret event-bed deposition in a hadal trench environment. The sediment cores were collected using a giant piston corer (up to 40 m core length) and a trigger corer onboard R/V Kaimei during International Ocean Discovery Program (IODP) Expedition 386 "Japan Trench Paleoseismology" between 13 April and 1 June 2021. Grain-size data were generated using two complementary methods: laser diffraction with a Malvern Mastersizer 3000 at the Department of Geology (UIBK) and dynamic image analysis with a Camsizer X2 at the Disaster Prevention Research Institute (Kyoto University). Sampling followed two strategies: (i) systematic sampling at 1–2 cm intervals and (ii) site-specific sampling of selected coarse- and fine-grained facies of event beds and hemipelagic sediments. For the systematic dataset, Event Bed 2 was analyzed in one core (M0083D), and Event Bed 3 in six cores (M0091B, M0091D, M0090B, M0090D, M0083B, and M0083D). For the site-specific dataset, the four event beds were sampled in eleven cores (M0083B, M0083D, M0083F, M0089A, M0089B, M0089D, M0090A, M0090B, M0090D, M0091B, and M0091D). This compilation provides a reference dataset for refining facies models that advances event stratigraphy and improves global understanding of deep-marine sedimentary dynamics.
Related to:
Muthre, Mishelle; Proust, Jean-Noël; Pizer, Charlotte; Ikehara, Ken; Huang, Jyh-Jaan Steven; Naruse, Hajime; Strasser, Michael (2025): Facies analysis provides new insights into event bed deposition in a hadal trench environment. Sedimentology, sed.70069, https://doi.org/10.1111/sed.70069
Source:
IODP Expedition 386 - Japan Trench Paleoseismology [web service]. https://iodp.pangaea.de/front_content.php?idcat=653
Coverage:
Median Latitude: 38.377224 * Median Longitude: 144.036247 * South-bound Latitude: 37.412350 * West-bound Longitude: 143.728817 * North-bound Latitude: 38.758967 * East-bound Longitude: 144.129483
Date/Time Start: 2021-04-24T00:00:00 * Date/Time End: 2021-05-28T00:00:00
Minimum DEPTH, sediment/rock: 0.050 m * Maximum DEPTH, sediment/rock: 22.730 m
Event(s):
386-M0083B (JTPC-05A) * Latitude: 38.756883 * Longitude: 144.129250 * Date/Time Start: 2021-04-24T00:00:00 * Date/Time End: 2021-04-24T00:00:00 * Elevation: -7620.0 m * Location: Japan Trench * Campaign: Exp386 * Basis: Kaimei * Method/Device: Giant piston corer (GPC) * Comment: IGSN: IBCR0386EHV2001. Comment: 20 m
386-M0083D (JTPC-05A) * Latitude: 38.758500 * Longitude: 144.128650 * Date/Time Start: 2021-05-01T00:00:00 * Date/Time End: 2021-05-01T00:00:00 * Elevation: -7626.0 m * Location: Japan Trench * Campaign: Exp386 * Basis: Kaimei * Method/Device: Giant piston corer (GPC) * Comment: IGSN: IBCR0386EH24001. Comment: 40 m
386-M0083F (JTPC-05A) * Latitude: 38.758967 * Longitude: 144.129483 * Date/Time Start: 2021-05-11T00:00:00 * Date/Time End: 2021-05-11T00:00:00 * Elevation: -7620.0 m * Location: Japan Trench * Campaign: Exp386 * Basis: Kaimei * Method/Device: Giant piston corer (GPC) * Comment: IGSN: IBCR0386EH45001. Comment: 40 m
Parameter(s):
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
4113 data points
Data
| 1 Event | 2 Latitude | 3 Longitude | 4 Date/Time | 5 Elevation [m] | 6 Sample label | 7 Half | 8 Comment | 9 Depth sed [m] | 10 Device | 11 2000-1000 µm [%] | 12 1000-500 µm [%] | 13 500-250 µm [%] | 14 250-125 µm [%] | 15 125-63 µm [%] | 16 63-32 µm [%] | 17 32-16 µm [%] | 18 16-8 µm [%] | 19 8-4 µm [%] | 20 4-2 µm [%] | 21 >2 µm [%] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-16,65-66 | Working (W) | Event Bed 3 | 15.775 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0045 | 0.0095 | 0.0775 | 0.2621 | 0.3337 | 0.2303 | 0.0823 | 0.0000 |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-16,66-67 | Working (W) | Event Bed 3 | 15.785 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0020 | 0.0230 | 0.1010 | 0.2656 | 0.3127 | 0.2158 | 0.0798 | 0.0000 |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-16,67-68 | Working (W) | Event Bed 3 | 15.795 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0110 | 0.0100 | 0.0860 | 0.2681 | 0.3252 | 0.2203 | 0.0793 | 0.0000 |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-16,68-69 | Working (W) | Event Bed 3 | 15.805 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0055 | 0.0080 | 0.0250 | 0.1020 | 0.2651 | 0.3087 | 0.2023 | 0.0833 | 0.0000 |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-16,69-70 | Working (W) | Event Bed 3 | 15.815 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0155 | 0.0220 | 0.0155 | 0.0965 | 0.2661 | 0.3072 | 0.2068 | 0.0703 | 0.0000 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-15,53-54 | Working (W) | Event Bed 3 | 13.855 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0225 | 0.1100 | 0.3700 | 0.1580 | 0.1120 | 0.1074 | 0.0796 | 0.0404 | 0.0000 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-15,54-55 | Working (W) | Event Bed 3 | 13.865 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0080 | 0.1615 | 0.5020 | 0.1325 | 0.0720 | 0.0599 | 0.0441 | 0.0200 | 0.0000 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-15,55-56 | Working (W) | Event Bed 3 | 13.875 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0120 | 0.0880 | 0.3135 | 0.1800 | 0.1416 | 0.1264 | 0.0916 | 0.0469 | 0.0000 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-15,56-57 | Working (W) | Event Bed 3 | 13.885 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0165 | 0.1145 | 0.3670 | 0.1650 | 0.1170 | 0.1049 | 0.0766 | 0.0384 | 0.0000 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-15,57-58 | Working (W) | Event Bed 3 | 13.895 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0125 | 0.1490 | 0.3945 | 0.1455 | 0.1015 | 0.0939 | 0.0696 | 0.0334 | 0.0000 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-15,58-59 | Working (W) | Event Bed 3 | 13.905 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0145 | 0.1845 | 0.3555 | 0.1410 | 0.1020 | 0.0964 | 0.0736 | 0.0324 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,10-11 | Working (W) | Event Bed 3 | 1.115 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0050 | 0.0740 | 0.3885 | 0.3705 | 0.1120 | 0.0300 | 0.0145 | 0.0055 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,11-12 | Working (W) | Event Bed 3 | 1.125 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0050 | 0.0575 | 0.2785 | 0.3485 | 0.1675 | 0.0764 | 0.0456 | 0.0210 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,12-13 | Working (W) | Event Bed 3 | 1.135 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0070 | 0.0375 | 0.3440 | 0.3985 | 0.1180 | 0.0510 | 0.0300 | 0.0140 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,13-14 | Working (W) | Event Bed 3 | 1.145 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0065 | 0.0630 | 0.4285 | 0.3745 | 0.0755 | 0.0290 | 0.0165 | 0.0065 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,14-15 | Working (W) | Event Bed 3 | 1.155 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0075 | 0.2385 | 0.4565 | 0.1385 | 0.0680 | 0.0490 | 0.0295 | 0.0125 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,15-16 | Working (W) | Event Bed 3 | 1.165 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0070 | 0.2965 | 0.4985 | 0.1100 | 0.0375 | 0.0270 | 0.0165 | 0.0070 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,16-17 | Working (W) | Event Bed 3 | 1.175 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0080 | 0.2940 | 0.4725 | 0.1365 | 0.0420 | 0.0250 | 0.0150 | 0.0070 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,17-18 | Working (W) | Event Bed 3 | 1.185 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0215 | 0.1745 | 0.4135 | 0.2046 | 0.1014 | 0.0606 | 0.0239 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,18-19 | Working (W) | Event Bed 3 | 1.195 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0060 | 0.0340 | 0.2075 | 0.4080 | 0.1956 | 0.0844 | 0.0446 | 0.0200 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,19-20 | Working (W) | Event Bed 3 | 1.205 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0070 | 0.1820 | 0.4830 | 0.1705 | 0.0700 | 0.0460 | 0.0295 | 0.0120 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,20-21 | Working (W) | Event Bed 3 | 1.215 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0050 | 0.0905 | 0.3085 | 0.3065 | 0.1460 | 0.0744 | 0.0466 | 0.0225 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,21-22 | Working (W) | Event Bed 3 | 1.225 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0050 | 0.0160 | 0.1580 | 0.3845 | 0.2256 | 0.1084 | 0.0686 | 0.0339 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,22-23 | Working (W) | Event Bed 3 | 1.235 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0045 | 0.0315 | 0.1825 | 0.3170 | 0.2186 | 0.1274 | 0.0826 | 0.0359 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,23-24 | Working (W) | Event Bed 3 | 1.245 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0090 | 0.0570 | 0.1880 | 0.2915 | 0.2001 | 0.1304 | 0.0876 | 0.0364 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,24-25 | Working (W) | Event Bed 3 | 1.255 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0150 | 0.1000 | 0.3475 | 0.2465 | 0.1245 | 0.0839 | 0.0576 | 0.0249 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,25-26 | Working (W) | Event Bed 3 | 1.265 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0205 | 0.1070 | 0.3800 | 0.2320 | 0.1115 | 0.0804 | 0.0486 | 0.0200 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,26-27 | Working (W) | Event Bed 3 | 1.275 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0100 | 0.1455 | 0.4640 | 0.1935 | 0.0765 | 0.0575 | 0.0381 | 0.0150 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,27-28 | Working (W) | Event Bed 3 | 1.285 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0060 | 0.1155 | 0.4970 | 0.2335 | 0.0720 | 0.0400 | 0.0250 | 0.0110 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,28-29 | Working (W) | Event Bed 3 | 1.295 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0120 | 0.0645 | 0.3090 | 0.2825 | 0.1300 | 0.0969 | 0.0716 | 0.0334 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,29-30 | Working (W) | Event Bed 3 | 1.305 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0150 | 0.0840 | 0.2925 | 0.2200 | 0.1496 | 0.1194 | 0.0841 | 0.0354 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,30-31 | Working (W) | Event Bed 3 | 1.315 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0080 | 0.1970 | 0.4610 | 0.1830 | 0.0695 | 0.0430 | 0.0265 | 0.0120 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,31-32 | Working (W) | Event Bed 3 | 1.325 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0065 | 0.1840 | 0.4630 | 0.1835 | 0.0710 | 0.0465 | 0.0321 | 0.0135 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,32-33 | Working (W) | Event Bed 3 | 1.335 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0065 | 0.0455 | 0.2315 | 0.4000 | 0.1625 | 0.0784 | 0.0531 | 0.0224 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,33-34 | Working (W) | Event Bed 3 | 1.345 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0055 | 0.0375 | 0.2535 | 0.3965 | 0.1685 | 0.0739 | 0.0456 | 0.0190 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,34-35 | Working (W) | Event Bed 3 | 1.355 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0055 | 0.0440 | 0.2205 | 0.2965 | 0.1961 | 0.1204 | 0.0826 | 0.0344 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,35-36 | Working (W) | Event Bed 3 | 1.365 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0055 | 0.1045 | 0.3975 | 0.2325 | 0.1095 | 0.0754 | 0.0531 | 0.0220 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,36-37 | Working (W) | Event Bed 3 | 1.375 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0070 | 0.1135 | 0.4160 | 0.2355 | 0.1035 | 0.0654 | 0.0406 | 0.0185 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,37-38 | Working (W) | Event Bed 3 | 1.385 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0065 | 0.1375 | 0.5170 | 0.1870 | 0.0690 | 0.0450 | 0.0270 | 0.0110 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,38-39 | Working (W) | Event Bed 3 | 1.395 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0055 | 0.1215 | 0.6460 | 0.1660 | 0.0290 | 0.0170 | 0.0105 | 0.0045 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,5-6 | Working (W) | Event Bed 3 | 1.065 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0150 | 0.0330 | 0.1235 | 0.2411 | 0.2718 | 0.2123 | 0.1033 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,6-7 | Working (W) | Event Bed 3 | 1.075 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0055 | 0.1750 | 0.2445 | 0.1825 | 0.1541 | 0.1189 | 0.0811 | 0.0384 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,7-8 | Working (W) | Event Bed 3 | 1.085 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0180 | 0.4750 | 0.3260 | 0.0815 | 0.0445 | 0.0290 | 0.0175 | 0.0085 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,8-9 | Working (W) | Event Bed 3 | 1.095 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0060 | 0.0870 | 0.2085 | 0.3625 | 0.2500 | 0.0579 | 0.0190 | 0.0090 | 0.0000 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,9-10 | Working (W) | Event Bed 3 | 1.105 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0065 | 0.0645 | 0.3105 | 0.4425 | 0.1195 | 0.0335 | 0.0165 | 0.0065 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,49-50 | Working (W) | Event Bed 3 | 2.855 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0225 | 0.3280 | 0.3380 | 0.1390 | 0.0775 | 0.0500 | 0.0310 | 0.0140 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,50-51 | Working (W) | Event Bed 3 | 2.865 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0065 | 0.2120 | 0.3465 | 0.2675 | 0.1065 | 0.0340 | 0.0190 | 0.0080 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,51-52 | Working (W) | Event Bed 3 | 2.875 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0170 | 0.0740 | 0.1775 | 0.3315 | 0.1951 | 0.1079 | 0.0681 | 0.0289 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,52-53 | Working (W) | Event Bed 3 | 2.885 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0120 | 0.1575 | 0.3565 | 0.1920 | 0.1200 | 0.0834 | 0.0536 | 0.0249 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,53-54 | Working (W) | Event Bed 3 | 2.895 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0060 | 0.0235 | 0.1245 | 0.3350 | 0.2611 | 0.1344 | 0.0816 | 0.0339 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,54-55 | Working (W) | Event Bed 3 | 2.905 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0080 | 0.0570 | 0.1490 | 0.3490 | 0.2461 | 0.1064 | 0.0581 | 0.0264 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,55-56 | Working (W) | Event Bed 3 | 2.915 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0120 | 0.0450 | 0.1830 | 0.3740 | 0.2156 | 0.0934 | 0.0536 | 0.0234 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,56-57 | Working (W) | Event Bed 3 | 2.925 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0080 | 0.0505 | 0.3210 | 0.4160 | 0.1395 | 0.0375 | 0.0190 | 0.0085 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,57-58 | Working (W) | Event Bed 3 | 2.935 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0140 | 0.0685 | 0.2885 | 0.3220 | 0.1505 | 0.0784 | 0.0516 | 0.0264 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,58-59 | Working (W) | Event Bed 3 | 2.945 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0100 | 0.1035 | 0.5660 | 0.1910 | 0.0565 | 0.0375 | 0.0250 | 0.0105 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,59-60 | Working (W) | Event Bed 3 | 2.955 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0325 | 0.1400 | 0.3190 | 0.1980 | 0.1185 | 0.0969 | 0.0651 | 0.0299 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,60-61 | Working (W) | Event Bed 3 | 2.965 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0095 | 0.2310 | 0.4050 | 0.1510 | 0.0850 | 0.0624 | 0.0386 | 0.0175 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,61-62 | Working (W) | Event Bed 3 | 2.975 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0085 | 0.2980 | 0.4350 | 0.1260 | 0.0565 | 0.0395 | 0.0255 | 0.0110 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,62-63 | Working (W) | Event Bed 3 | 2.985 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0115 | 0.3135 | 0.4380 | 0.1155 | 0.0505 | 0.0380 | 0.0240 | 0.0090 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,63-64 | Working (W) | Event Bed 3 | 2.995 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0095 | 0.2810 | 0.4415 | 0.1320 | 0.0590 | 0.0405 | 0.0255 | 0.0110 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,64-65 | Working (W) | Event Bed 3 | 3.005 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0055 | 0.1575 | 0.4050 | 0.2970 | 0.0745 | 0.0335 | 0.0195 | 0.0075 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,65-66 | Working (W) | Event Bed 3 | 3.015 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0185 | 0.4480 | 0.3230 | 0.0910 | 0.0525 | 0.0345 | 0.0230 | 0.0095 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,66-67 | Working (W) | Event Bed 3 | 3.025 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0135 | 0.4245 | 0.3245 | 0.1050 | 0.0585 | 0.0380 | 0.0245 | 0.0115 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,67-68 | Working (W) | Event Bed 3 | 3.035 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0035 | 0.0175 | 0.1700 | 0.4060 | 0.2076 | 0.1054 | 0.0641 | 0.0259 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,68-69 | Working (W) | Event Bed 3 | 3.045 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0025 | 0.0410 | 0.1875 | 0.3045 | 0.2061 | 0.1284 | 0.0891 | 0.0409 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,69-70 | Working (W) | Event Bed 3 | 3.055 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0105 | 0.0775 | 0.2930 | 0.3155 | 0.1460 | 0.0819 | 0.0501 | 0.0254 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,70-71 | Working (W) | Event Bed 3 | 3.065 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0030 | 0.0130 | 0.1480 | 0.4845 | 0.2650 | 0.0554 | 0.0215 | 0.0095 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,71-72 | Working (W) | Event Bed 3 | 3.075 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0045 | 0.0685 | 0.2315 | 0.3555 | 0.2025 | 0.0754 | 0.0416 | 0.0205 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,72-73 | Working (W) | Event Bed 3 | 3.085 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0085 | 0.2095 | 0.4515 | 0.2020 | 0.0650 | 0.0345 | 0.0205 | 0.0085 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,73-74 | Working (W) | Event Bed 3 | 3.095 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0090 | 0.1995 | 0.4010 | 0.2085 | 0.0850 | 0.0505 | 0.0325 | 0.0140 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,74-75 | Working (W) | Event Bed 3 | 3.105 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0070 | 0.0995 | 0.3760 | 0.2680 | 0.1175 | 0.0664 | 0.0436 | 0.0220 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,75-76 | Working (W) | Event Bed 3 | 3.115 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0140 | 0.1935 | 0.4110 | 0.1690 | 0.0870 | 0.0629 | 0.0436 | 0.0190 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,76-77 | Working (W) | Event Bed 3 | 3.125 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0095 | 0.3240 | 0.4165 | 0.1185 | 0.0550 | 0.0390 | 0.0260 | 0.0115 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,77-78 | Working (W) | Event Bed 3 | 3.135 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0065 | 0.2790 | 0.4545 | 0.1300 | 0.0535 | 0.0380 | 0.0265 | 0.0120 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,78-79 | Working (W) | Event Bed 3 | 3.145 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0115 | 0.1045 | 0.4190 | 0.2230 | 0.0985 | 0.0699 | 0.0491 | 0.0244 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,79-80 | Working (W) | Event Bed 3 | 3.155 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0055 | 0.0440 | 0.3980 | 0.3305 | 0.1080 | 0.0574 | 0.0391 | 0.0175 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,80-81 | Working (W) | Event Bed 3 | 3.165 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0080 | 0.0450 | 0.3435 | 0.3415 | 0.1220 | 0.0709 | 0.0486 | 0.0204 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,81-82 | Working (W) | Event Bed 3 | 3.175 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0045 | 0.1220 | 0.4215 | 0.2070 | 0.1135 | 0.0679 | 0.0426 | 0.0210 | 0.0000 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,82-83 | Working (W) | Event Bed 3 | 3.185 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0040 | 0.1450 | 0.5095 | 0.1880 | 0.0745 | 0.0415 | 0.0255 | 0.0120 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,67-68 | Working (W) | Event Bed 3 | 12.695 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0080 | 0.1995 | 0.4390 | 0.1215 | 0.0780 | 0.0704 | 0.0546 | 0.0289 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,68-69 | Working (W) | Event Bed 3 | 12.705 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0125 | 0.2675 | 0.4055 | 0.1335 | 0.0665 | 0.0550 | 0.0391 | 0.0205 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,69-70 | Working (W) | Event Bed 3 | 12.715 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0160 | 0.2250 | 0.3575 | 0.1180 | 0.0875 | 0.0889 | 0.0701 | 0.0369 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,70-71 | Working (W) | Event Bed 3 | 12.725 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.1715 | 0.3470 | 0.1415 | 0.1125 | 0.1079 | 0.0806 | 0.0389 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,71-72 | Working (W) | Event Bed 3 | 12.735 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0200 | 0.3010 | 0.2980 | 0.0950 | 0.0885 | 0.0939 | 0.0701 | 0.0334 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,72-73 | Working (W) | Event Bed 3 | 12.745 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0300 | 0.5035 | 0.2850 | 0.0565 | 0.0450 | 0.0395 | 0.0270 | 0.0135 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,73-74 | Working (W) | Event Bed 3 | 12.755 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0345 | 0.4350 | 0.2095 | 0.0750 | 0.0840 | 0.0829 | 0.0551 | 0.0239 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,74-75 | Working (W) | Event Bed 3 | 12.765 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0295 | 0.4735 | 0.2700 | 0.0700 | 0.0590 | 0.0495 | 0.0330 | 0.0155 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,75-76 | Working (W) | Event Bed 3 | 12.775 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0275 | 0.3425 | 0.2525 | 0.1015 | 0.1005 | 0.0904 | 0.0586 | 0.0264 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,76-77 | Working (W) | Event Bed 3 | 12.785 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0325 | 0.3475 | 0.2610 | 0.0880 | 0.0860 | 0.0874 | 0.0651 | 0.0324 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,77-78 | Working (W) | Event Bed 3 | 12.795 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0240 | 0.3430 | 0.3195 | 0.0885 | 0.0770 | 0.0749 | 0.0511 | 0.0220 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,78-79 | Working (W) | Event Bed 3 | 12.805 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0255 | 0.2950 | 0.3290 | 0.1025 | 0.0735 | 0.0784 | 0.0636 | 0.0324 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,79-80 | Working (W) | Event Bed 3 | 12.815 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0195 | 0.3320 | 0.3175 | 0.0915 | 0.0790 | 0.0779 | 0.0556 | 0.0269 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,80-81 | Working (W) | Event Bed 3 | 12.825 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0125 | 0.1965 | 0.3075 | 0.1290 | 0.1161 | 0.1124 | 0.0841 | 0.0419 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,81-82 | Working (W) | Event Bed 3 | 12.835 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0260 | 0.2705 | 0.3080 | 0.1070 | 0.0910 | 0.0924 | 0.0706 | 0.0344 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,82-83 | Working (W) | Event Bed 3 | 12.845 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0310 | 0.3410 | 0.2780 | 0.0865 | 0.0820 | 0.0874 | 0.0641 | 0.0299 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,83-84 | Working (W) | Event Bed 3 | 12.855 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0315 | 0.3375 | 0.2925 | 0.0765 | 0.0820 | 0.0859 | 0.0641 | 0.0299 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,84-85 | Working (W) | Event Bed 3 | 12.865 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0925 | 0.2590 | 0.1445 | 0.1801 | 0.1704 | 0.1082 | 0.0454 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,85-86 | Working (W) | Event Bed 3 | 12.875 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0155 | 0.3335 | 0.3635 | 0.0950 | 0.0650 | 0.0594 | 0.0451 | 0.0230 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,86-87 | Working (W) | Event Bed 3 | 12.885 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0045 | 0.1890 | 0.3195 | 0.1205 | 0.1216 | 0.1214 | 0.0861 | 0.0374 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,87-88 | Working (W) | Event Bed 3 | 12.895 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0050 | 0.1870 | 0.2705 | 0.1295 | 0.1336 | 0.1354 | 0.0961 | 0.0429 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,88-89 | Working (W) | Event Bed 3 | 12.905 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.1335 | 0.3405 | 0.1345 | 0.1281 | 0.1304 | 0.0926 | 0.0404 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,89-90 | Working (W) | Event Bed 3 | 12.915 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0220 | 0.2435 | 0.2710 | 0.1090 | 0.1126 | 0.1179 | 0.0851 | 0.0389 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,90-91 | Working (W) | Event Bed 3 | 12.925 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0120 | 0.2300 | 0.2295 | 0.1190 | 0.1321 | 0.1429 | 0.0956 | 0.0389 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,91-92 | Working (W) | Event Bed 3 | 12.935 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0190 | 0.3640 | 0.3400 | 0.0845 | 0.0645 | 0.0599 | 0.0451 | 0.0230 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,92-93 | Working (W) | Event Bed 3 | 12.945 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0330 | 0.3560 | 0.2845 | 0.0845 | 0.0835 | 0.0799 | 0.0551 | 0.0235 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,93-94 | Working (W) | Event Bed 3 | 12.955 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0040 | 0.2565 | 0.3155 | 0.1140 | 0.1065 | 0.1019 | 0.0701 | 0.0314 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,94-95 | Working (W) | Event Bed 3 | 12.965 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0050 | 0.2460 | 0.2895 | 0.1210 | 0.1135 | 0.1114 | 0.0786 | 0.0349 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,95-96 | Working (W) | Event Bed 3 | 12.975 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0040 | 0.2180 | 0.2430 | 0.1150 | 0.1306 | 0.1434 | 0.1022 | 0.0439 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,96-97 | Working (W) | Event Bed 3 | 12.985 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0615 | 0.4565 | 0.2415 | 0.0800 | 0.0625 | 0.0500 | 0.0331 | 0.0150 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,97-98 | Working (W) | Event Bed 3 | 12.995 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0975 | 0.5330 | 0.1640 | 0.0645 | 0.0600 | 0.0450 | 0.0255 | 0.0105 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,98-99 | Working (W) | Event Bed 3 | 13.005 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0895 | 0.5915 | 0.1710 | 0.0460 | 0.0410 | 0.0325 | 0.0200 | 0.0085 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,99-100 | Working (W) | Event Bed 3 | 13.015 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0810 | 0.5350 | 0.1835 | 0.0645 | 0.0540 | 0.0430 | 0.0270 | 0.0120 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-14,0-1 | Working (W) | Event Bed 3 | 13.035 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0005 | 0.1120 | 0.6445 | 0.1165 | 0.0445 | 0.0350 | 0.0255 | 0.0150 | 0.0065 | 0.0000 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-14,1-2 | Working (W) | Event Bed 3 | 13.045 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0480 | 0.4245 | 0.2185 | 0.0945 | 0.0825 | 0.0664 | 0.0441 | 0.0215 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,38-39 | Working (W) | Event Bed 3 | 12.730 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0220 | 0.2195 | 0.2220 | 0.1841 | 0.1644 | 0.1247 | 0.0634 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,39-40 | Working (W) | Event Bed 3 | 12.740 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0205 | 0.2400 | 0.2270 | 0.1771 | 0.1559 | 0.1192 | 0.0604 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,40-41 | Working (W) | Event Bed 3 | 12.750 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0210 | 0.1540 | 0.2040 | 0.2176 | 0.1948 | 0.1397 | 0.0689 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,41-42 | Working (W) | Event Bed 3 | 12.760 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0105 | 0.0385 | 0.1685 | 0.1755 | 0.1996 | 0.1918 | 0.1422 | 0.0734 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,42-43 | Working (W) | Event Bed 3 | 12.770 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0205 | 0.1645 | 0.1915 | 0.2091 | 0.1953 | 0.1447 | 0.0744 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,43-44 | Working (W) | Event Bed 3 | 12.780 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0235 | 0.0810 | 0.1420 | 0.1705 | 0.2096 | 0.1853 | 0.1262 | 0.0619 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,44-45 | Working (W) | Event Bed 3 | 12.790 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0185 | 0.1735 | 0.2055 | 0.2156 | 0.1893 | 0.1352 | 0.0624 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,45-46 | Working (W) | Event Bed 3 | 12.800 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0200 | 0.0530 | 0.2210 | 0.1870 | 0.1821 | 0.1669 | 0.1162 | 0.0539 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,46-47 | Working (W) | Event Bed 3 | 12.810 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0000 | 0.0280 | 0.1985 | 0.2105 | 0.2046 | 0.1758 | 0.1242 | 0.0584 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,47-48 | Working (W) | Event Bed 3 | 12.820 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0080 | 0.1310 | 0.4075 | 0.1880 | 0.1100 | 0.0774 | 0.0526 | 0.0255 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,48-49 | Working (W) | Event Bed 3 | 12.830 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0170 | 0.1745 | 0.3940 | 0.1535 | 0.1035 | 0.0769 | 0.0536 | 0.0269 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,49-50 | Working (W) | Event Bed 3 | 12.840 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0065 | 0.0865 | 0.3045 | 0.1925 | 0.1466 | 0.1244 | 0.0921 | 0.0469 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,50-51 | Working (W) | Event Bed 3 | 12.850 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0100 | 0.1625 | 0.3525 | 0.1585 | 0.1130 | 0.0959 | 0.0711 | 0.0364 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,51-52 | Working (W) | Event Bed 3 | 12.860 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0050 | 0.0925 | 0.3005 | 0.1790 | 0.1436 | 0.1299 | 0.1007 | 0.0489 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,52-53 | Working (W) | Event Bed 3 | 12.870 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0130 | 0.2975 | 0.3765 | 0.1260 | 0.0740 | 0.0564 | 0.0376 | 0.0190 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,53-54 | Working (W) | Event Bed 3 | 12.880 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0205 | 0.3640 | 0.3670 | 0.0965 | 0.0620 | 0.0470 | 0.0295 | 0.0135 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,54-55 | Working (W) | Event Bed 3 | 12.890 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0180 | 0.3455 | 0.3715 | 0.1110 | 0.0640 | 0.0475 | 0.0295 | 0.0130 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,55-56 | Working (W) | Event Bed 3 | 12.900 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0175 | 0.5055 | 0.3610 | 0.0485 | 0.0280 | 0.0205 | 0.0130 | 0.0060 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,56-57 | Working (W) | Event Bed 3 | 12.910 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0405 | 0.5420 | 0.2435 | 0.0600 | 0.0500 | 0.0350 | 0.0200 | 0.0090 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,57-58 | Working (W) | Event Bed 3 | 12.920 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0285 | 0.4775 | 0.2555 | 0.0775 | 0.0645 | 0.0515 | 0.0311 | 0.0140 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,58-59 | Working (W) | Event Bed 3 | 12.930 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0190 | 0.4555 | 0.3350 | 0.0665 | 0.0490 | 0.0395 | 0.0245 | 0.0110 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,59-60 | Working (W) | Event Bed 3 | 12.940 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0450 | 0.5650 | 0.2050 | 0.0555 | 0.0525 | 0.0400 | 0.0260 | 0.0110 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,60-61 | Working (W) | Event Bed 3 | 12.950 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0335 | 0.4740 | 0.2570 | 0.0700 | 0.0645 | 0.0520 | 0.0341 | 0.0150 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,61-62 | Working (W) | Event Bed 3 | 12.960 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0270 | 0.4340 | 0.2875 | 0.0795 | 0.0665 | 0.0545 | 0.0351 | 0.0160 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,62-63 | Working (W) | Event Bed 3 | 12.970 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0370 | 0.4430 | 0.2950 | 0.0730 | 0.0580 | 0.0480 | 0.0325 | 0.0135 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,63-64 | Working (W) | Event Bed 3 | 12.980 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0350 | 0.3975 | 0.2780 | 0.0895 | 0.0720 | 0.0629 | 0.0456 | 0.0195 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,64-65 | Working (W) | Event Bed 3 | 12.990 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0310 | 0.4375 | 0.3220 | 0.0775 | 0.0535 | 0.0415 | 0.0260 | 0.0110 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,65-66 | Working (W) | Event Bed 3 | 13.000 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0475 | 0.4720 | 0.2915 | 0.0650 | 0.0480 | 0.0390 | 0.0265 | 0.0105 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,66-67 | Working (W) | Event Bed 3 | 13.010 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0835 | 0.5235 | 0.2160 | 0.0620 | 0.0495 | 0.0360 | 0.0215 | 0.0080 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,67-68 | Working (W) | Event Bed 3 | 13.020 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0700 | 0.5385 | 0.2440 | 0.0560 | 0.0390 | 0.0275 | 0.0175 | 0.0075 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,68-69 | Working (W) | Event Bed 3 | 13.030 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0665 | 0.6000 | 0.2215 | 0.0400 | 0.0300 | 0.0225 | 0.0140 | 0.0055 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,69-70 | Working (W) | Event Bed 3 | 13.040 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0570 | 0.5105 | 0.2215 | 0.0670 | 0.0590 | 0.0460 | 0.0275 | 0.0115 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,70-71 | Working (W) | Event Bed 3 | 13.050 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0570 | 0.4390 | 0.2015 | 0.0890 | 0.0800 | 0.0664 | 0.0461 | 0.0210 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,71-72 | Working (W) | Event Bed 3 | 13.060 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0640 | 0.5475 | 0.2175 | 0.0575 | 0.0460 | 0.0355 | 0.0220 | 0.0100 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,72-73 | Working (W) | Event Bed 3 | 13.070 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0610 | 0.4520 | 0.2105 | 0.0895 | 0.0690 | 0.0589 | 0.0406 | 0.0185 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,73-74 | Working (W) | Event Bed 3 | 13.080 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0670 | 0.3790 | 0.1880 | 0.1040 | 0.0930 | 0.0854 | 0.0601 | 0.0234 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,74-75 | Working (W) | Event Bed 3 | 13.090 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0950 | 0.4365 | 0.1835 | 0.0880 | 0.0735 | 0.0624 | 0.0421 | 0.0190 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,75-76 | Working (W) | Event Bed 3 | 13.100 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.1410 | 0.5080 | 0.1310 | 0.0755 | 0.0585 | 0.0445 | 0.0295 | 0.0120 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,76-77 | Working (W) | Event Bed 3 | 13.110 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.1000 | 0.3785 | 0.1970 | 0.1250 | 0.0830 | 0.0594 | 0.0391 | 0.0180 | 0.0000 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,77-78 | Working (W) | Event Bed 3 | 13.120 | Dynamic image analyzer (Camsizer X2) | 0.0000 | 0.0000 | 0.0285 | 0.2580 | 0.2055 | 0.1770 | 0.1395 | 0.1014 | 0.0626 | 0.0274 | 0.0000 |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-14,54-56 | Working (W) | 13.600 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0013 | 0.0775 | 0.2134 | 0.1717 | 0.1271 | 0.1329 | 0.1263 | 0.1016 | 0.0483 | |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-16,25-27 | Working (W) | 15.375 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0022 | 0.0359 | 0.1330 | 0.2188 | 0.2189 | 0.1838 | 0.1417 | 0.0657 | |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-17,21-23 | Working (W) | 16.375 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0024 | 0.0858 | 0.1968 | 0.2022 | 0.1806 | 0.1572 | 0.1212 | 0.0538 | |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-18,26-28 | Working (W) | 17.430 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0007 | 0.0106 | 0.0504 | 0.1420 | 0.2108 | 0.2126 | 0.1828 | 0.1330 | 0.0572 | |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-19,41-43 | Working (W) | 18.580 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0039 | 0.0743 | 0.1913 | 0.2077 | 0.1776 | 0.1557 | 0.1270 | 0.0624 | |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-2,94-96 | Working (W) | 1.920 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0001 | 0.0086 | 0.0684 | 0.1853 | 0.2391 | 0.2038 | 0.1511 | 0.1001 | 0.0435 | |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-8,56-58 | Working (W) | 7.575 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0147 | 0.1603 | 0.3118 | 0.1897 | 0.1041 | 0.0866 | 0.0649 | 0.0465 | 0.0213 | |
| 386-M0083B | 38.7569 | 144.1293 | 2021-04-24 | -7620 | 386-M0083B-1H-9,75-77 | Working (W) | 8.775 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0235 | 0.1147 | 0.1739 | 0.1668 | 0.1519 | 0.1364 | 0.1145 | 0.0822 | 0.0361 | |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,10-10.5 | Working (W) | Event Bed 2 | 0.100 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0975 | 0.2396 | 0.2088 | 0.1684 | 0.1308 | 0.1012 | 0.0537 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,12-12.5 | Working (W) | Event Bed 2 | 0.120 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0079 | 0.1222 | 0.2189 | 0.2057 | 0.1634 | 0.1265 | 0.1007 | 0.0547 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,14-14.5 | Working (W) | Event Bed 2 | 0.140 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.1014 | 0.2487 | 0.2085 | 0.1653 | 0.1287 | 0.0976 | 0.0498 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,16-16.5 | Working (W) | Event Bed 2 | 0.160 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0024 | 0.1149 | 0.2070 | 0.1949 | 0.1777 | 0.1509 | 0.1076 | 0.0447 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,18-18.5 | Working (W) | Event Bed 2 | 0.180 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0040 | 0.1089 | 0.1974 | 0.1965 | 0.1831 | 0.1550 | 0.1098 | 0.0454 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,20-20.5 | Working (W) | Event Bed 2 | 0.200 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0063 | 0.1102 | 0.1989 | 0.1990 | 0.1816 | 0.1543 | 0.1072 | 0.0425 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,22-22.5 | Working (W) | Event Bed 2 | 0.220 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0035 | 0.1070 | 0.1921 | 0.1900 | 0.1844 | 0.1605 | 0.1151 | 0.0474 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,24-24.5 | Working (W) | Event Bed 2 | 0.240 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0072 | 0.1199 | 0.2152 | 0.2057 | 0.1669 | 0.1304 | 0.1015 | 0.0532 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,26-26.5 | Working (W) | Event Bed 2 | 0.260 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0041 | 0.1157 | 0.2204 | 0.2097 | 0.1667 | 0.1301 | 0.1011 | 0.0524 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,28-28.5 | Working (W) | Event Bed 2 | 0.280 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0011 | 0.1120 | 0.2255 | 0.2111 | 0.1683 | 0.1302 | 0.0999 | 0.0519 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,30-30.5 | Working (W) | Event Bed 2 | 0.300 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0039 | 0.1220 | 0.2252 | 0.2108 | 0.1634 | 0.1258 | 0.0980 | 0.0510 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,32-32.5 | Working (W) | Event Bed 2 | 0.320 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0110 | 0.1426 | 0.2314 | 0.1993 | 0.1536 | 0.1189 | 0.0936 | 0.0498 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,34-34.5 | Working (W) | Event Bed 2 | 0.340 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0090 | 0.1247 | 0.2182 | 0.2054 | 0.1628 | 0.1258 | 0.1000 | 0.0541 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,36-36.5 | Working (W) | Event Bed 2 | 0.360 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0046 | 0.1309 | 0.2259 | 0.2003 | 0.1605 | 0.1247 | 0.0992 | 0.0539 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,38-38.5 | Working (W) | Event Bed 2 | 0.380 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0085 | 0.1176 | 0.2133 | 0.2101 | 0.1667 | 0.1300 | 0.1011 | 0.0526 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,40-40.5 | Working (W) | Event Bed 2 | 0.400 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0143 | 0.1013 | 0.2012 | 0.2138 | 0.1728 | 0.1356 | 0.1059 | 0.0551 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,42-42.5 | Working (W) | Event Bed 2 | 0.420 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0078 | 0.1171 | 0.2127 | 0.2085 | 0.1678 | 0.1313 | 0.1019 | 0.0527 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,44-44.5 | Working (W) | Event Bed 2 | 0.440 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0078 | 0.1129 | 0.2139 | 0.2123 | 0.1683 | 0.1312 | 0.1016 | 0.0520 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,46-46.5 | Working (W) | Event Bed 2 | 0.460 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0108 | 0.1178 | 0.2141 | 0.2091 | 0.1655 | 0.1299 | 0.1009 | 0.0520 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,48-48.5 | Working (W) | Event Bed 2 | 0.480 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0176 | 0.1611 | 0.2369 | 0.1950 | 0.1469 | 0.1140 | 0.0859 | 0.0425 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,50-50.5 | Working (W) | Event Bed 2 | 0.500 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0189 | 0.1500 | 0.2279 | 0.1973 | 0.1517 | 0.1180 | 0.0902 | 0.0461 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,52-52.5 | Working (W) | Event Bed 2 | 0.520 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0236 | 0.1624 | 0.2292 | 0.1912 | 0.1470 | 0.1148 | 0.0876 | 0.0441 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,54-54.5 | Working (W) | Event Bed 2 | 0.540 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0226 | 0.1547 | 0.2282 | 0.1936 | 0.1489 | 0.1162 | 0.0897 | 0.0462 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,56-56.5 | Working (W) | Event Bed 2 | 0.560 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0195 | 0.1391 | 0.2181 | 0.1990 | 0.1562 | 0.1223 | 0.0958 | 0.0500 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,58-58.5 | Working (W) | Event Bed 2 | 0.580 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0194 | 0.1502 | 0.2269 | 0.1957 | 0.1535 | 0.1206 | 0.0901 | 0.0436 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,60-60.5 | Working (W) | Event Bed 2 | 0.600 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0083 | 0.1229 | 0.2203 | 0.1936 | 0.1661 | 0.1374 | 0.1027 | 0.0486 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,62-62.5 | Working (W) | Event Bed 2 | 0.620 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0242 | 0.1303 | 0.1898 | 0.1814 | 0.1747 | 0.1537 | 0.1060 | 0.0398 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,64-64.5 | Working (W) | Event Bed 2 | 0.640 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0123 | 0.1173 | 0.1864 | 0.1875 | 0.1839 | 0.1617 | 0.1101 | 0.0407 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,66-66.5 | Working (W) | Event Bed 2 | 0.660 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0188 | 0.1546 | 0.1970 | 0.1695 | 0.1688 | 0.1498 | 0.1026 | 0.0389 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,68-68.5 | Working (W) | Event Bed 2 | 0.680 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0412 | 0.2146 | 0.2281 | 0.1539 | 0.1356 | 0.1192 | 0.0795 | 0.0277 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,70-70.5 | Working (W) | Event Bed 2 | 0.700 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0440 | 0.2144 | 0.2185 | 0.1448 | 0.1369 | 0.1245 | 0.0864 | 0.0306 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,72-72.5 | Working (W) | Event Bed 2 | 0.720 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0633 | 0.2241 | 0.1952 | 0.1409 | 0.1405 | 0.1233 | 0.0828 | 0.0299 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,74-74.5 | Working (W) | Event Bed 2 | 0.740 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0669 | 0.2427 | 0.2125 | 0.1443 | 0.1233 | 0.0977 | 0.0748 | 0.0378 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,76-76.5 | Working (W) | Event Bed 2 | 0.760 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0002 | 0.1202 | 0.3465 | 0.2221 | 0.0981 | 0.0823 | 0.0623 | 0.0461 | 0.0222 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,78-78.5 | Working (W) | Event Bed 2 | 0.780 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0493 | 0.2440 | 0.2551 | 0.1517 | 0.1104 | 0.0872 | 0.0674 | 0.0350 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,80-80.5 | Working (W) | Event Bed 2 | 0.800 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0553 | 0.2490 | 0.2496 | 0.1473 | 0.1039 | 0.0863 | 0.0709 | 0.0378 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,82-82.5 | Working (W) | Event Bed 2 | 0.820 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0001 | 0.0840 | 0.2698 | 0.2144 | 0.1211 | 0.1002 | 0.0892 | 0.0777 | 0.0435 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,84-84.5 | Working (W) | Event Bed 2 | 0.840 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0103 | 0.1877 | 0.2755 | 0.1352 | 0.0938 | 0.0970 | 0.0907 | 0.0749 | 0.0349 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,86-86.5 | Working (W) | Event Bed 2 | 0.860 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0385 | 0.1748 | 0.1933 | 0.1269 | 0.1141 | 0.1148 | 0.1082 | 0.0889 | 0.0404 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,88-88.5 | Working (W) | Event Bed 2 | 0.880 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0154 | 0.1388 | 0.1699 | 0.1149 | 0.1211 | 0.1361 | 0.1353 | 0.1137 | 0.0549 |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,90-90.5 | Working (W) | 0.900 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0201 | 0.0915 | 0.1275 | 0.1667 | 0.1923 | 0.1852 | 0.1487 | 0.0680 | |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,92-92.5 | Working (W) | 0.920 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0284 | 0.0844 | 0.1262 | 0.1732 | 0.1928 | 0.1810 | 0.1459 | 0.0678 | |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,94-94.5 | Working (W) | 0.940 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0262 | 0.1951 | 0.1880 | 0.1861 | 0.1809 | 0.1488 | 0.0750 | |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,96-96.5 | Working (W) | 0.960 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0197 | 0.1080 | 0.1492 | 0.1741 | 0.1840 | 0.1662 | 0.1339 | 0.0649 | |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,98-98.5 | Working (W) | 0.980 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0009 | 0.0269 | 0.0821 | 0.1325 | 0.1727 | 0.1892 | 0.1784 | 0.1469 | 0.0706 | |
| 386-M0083D | 38.7585 | 144.1286 | 2021-05-01 | -7626 | 386-M0083D-1H-08,100-100 | Working (W) | 1.000 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0001 | 0.0167 | 0.0600 | 0.1295 | 0.1943 | 0.2059 | 0.1826 | 0.1436 | 0.0674 | |
| 386-M0083F | 38.7590 | 144.1295 | 2021-05-11 | -7620 | 386-M0083F-1H-1,63-65 | Working (W) | 0.630 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0066 | 0.0435 | 0.1451 | 0.1937 | 0.1776 | 0.1587 | 0.1341 | 0.0973 | 0.0434 | |
| 386-M0083F | 38.7590 | 144.1295 | 2021-05-11 | -7620 | 386-M0083F-1H-11,58-60 | Working (W) | 10.445 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0085 | 0.0375 | 0.0952 | 0.1698 | 0.2003 | 0.1832 | 0.1509 | 0.1072 | 0.0474 | |
| 386-M0083F | 38.7590 | 144.1295 | 2021-05-11 | -7620 | 386-M0083F-1H-18,84-86 | Working (W) | 17.780 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0054 | 0.0809 | 0.2109 | 0.2269 | 0.1700 | 0.1387 | 0.1125 | 0.0547 | |
| 386-M0083F | 38.7590 | 144.1295 | 2021-05-11 | -7620 | 386-M0083F-1H-19,78-80 | Working (W) | 18.735 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0002 | 0.0177 | 0.0902 | 0.1718 | 0.1976 | 0.1838 | 0.1602 | 0.1227 | 0.0556 | |
| 386-M0083F | 38.7590 | 144.1295 | 2021-05-11 | -7620 | 386-M0083F-1H-20,99-101 | Working (W) | 19.960 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0003 | 0.0917 | 0.2344 | 0.2137 | 0.1624 | 0.1397 | 0.1087 | 0.0491 | |
| 386-M0083F | 38.7590 | 144.1295 | 2021-05-11 | -7620 | 386-M0083F-1H-23,49-51 | Working (W) | 22.730 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0018 | 0.0720 | 0.1975 | 0.2112 | 0.1813 | 0.1584 | 0.1233 | 0.0544 | |
| 386-M0083F | 38.7590 | 144.1295 | 2021-05-11 | -7620 | 386-M0083F-1H-3,50-52 | Working (W) | 2.300 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0041 | 0.0222 | 0.0899 | 0.1770 | 0.2016 | 0.1844 | 0.1579 | 0.1135 | 0.0494 | |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-1,11-12 | Working (W) | Event Bed 1 | 0.110 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0048 | 0.0415 | 0.1407 | 0.2396 | 0.2521 | 0.1865 | 0.1011 | 0.0336 |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-1,21-22 | Working (W) | Event Bed 1 | 0.210 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0037 | 0.0319 | 0.0963 | 0.1906 | 0.2097 | 0.1835 | 0.1474 | 0.0961 | 0.0408 |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-1,24-25 | Working (W) | 0.240 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0011 | 0.0169 | 0.0733 | 0.1625 | 0.2115 | 0.2061 | 0.1705 | 0.1129 | 0.0452 | |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-2,2-3 | Working (W) | 0.580 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0001 | 0.0175 | 0.0792 | 0.1753 | 0.2151 | 0.1968 | 0.1603 | 0.1099 | 0.0457 | |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-2,24-25 | Working (W) | 0.800 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0010 | 0.0187 | 0.0725 | 0.1584 | 0.2031 | 0.2009 | 0.1752 | 0.1215 | 0.0487 | |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-2,31-32 | Working (W) | 0.870 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0029 | 0.0123 | 0.0650 | 0.1567 | 0.2025 | 0.1981 | 0.1765 | 0.1300 | 0.0561 | |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-2,44-45 | Working (W) | 1.000 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0035 | 0.0533 | 0.1568 | 0.2214 | 0.2140 | 0.1760 | 0.1230 | 0.0520 | |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-2,57-58 | Working (W) | 1.130 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0004 | 0.0038 | 0.0112 | 0.0657 | 0.1658 | 0.2226 | 0.2117 | 0.1690 | 0.1085 | 0.0413 | |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-2,66-67 | Working (W) | 1.220 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0007 | 0.0245 | 0.1005 | 0.1891 | 0.2047 | 0.1822 | 0.1526 | 0.1035 | 0.0423 | |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-2,72-73 | Working (W) | 1.280 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0025 | 0.0179 | 0.0771 | 0.1714 | 0.2097 | 0.1930 | 0.1623 | 0.1151 | 0.0510 | |
| 386-M0089A | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089A-1P-2,74-75 | Working (W) | 1.300 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0013 | 0.0136 | 0.0651 | 0.1537 | 0.2050 | 0.2070 | 0.1810 | 0.1242 | 0.0492 | |
| 386-M0089B | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089B-1H-3,6-8 | Working (W) | Event Bed 3 | 1.825 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0373 | 0.2273 | 0.3489 | 0.2107 | 0.0835 | 0.0596 | 0.0326 |
| 386-M0089B | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089B-1H-3,16-18 | Working (W) | Event Bed 3 | 1.925 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0117 | 0.0907 | 0.1678 | 0.2000 | 0.1853 | 0.1602 | 0.1243 | 0.0601 |
| 386-M0089B | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089B-1H-4,58-60 | Working (W) | 3.345 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0004 | 0.0257 | 0.1317 | 0.2328 | 0.2087 | 0.1505 | 0.1200 | 0.0894 | 0.0410 | |
| 386-M0089B | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089B-1H-5,58-60 | Working (W) | Event Bed 4 | 4.350 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0007 | 0.0183 | 0.0780 | 0.1807 | 0.2146 | 0.1907 | 0.1573 | 0.1117 | 0.0480 |
| 386-M0089B | 38.7200 | 144.1256 | 2021-05-09 | -7607 | 386-M0089B-1H-6,75-77 | Working (W) | 5.530 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0001 | 0.0252 | 0.1096 | 0.1919 | 0.2176 | 0.2067 | 0.1687 | 0.0803 | |
| 386-M0089D | 38.7205 | 144.1251 | 2021-05-10 | -7607 | 386-M0089D-1H-2,14-15 | Working (W) | 1.145 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0001 | 0.0106 | 0.0544 | 0.1478 | 0.2120 | 0.2147 | 0.1826 | 0.1260 | 0.0519 | |
| 386-M0089D | 38.7205 | 144.1251 | 2021-05-10 | -7607 | 386-M0089D-1H-2,4-5 | Working (W) | 1.045 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0491 | 0.1896 | 0.2166 | 0.1988 | 0.1697 | 0.1230 | 0.0531 | |
| 386-M0089D | 38.7205 | 144.1251 | 2021-05-10 | -7607 | 386-M0089D-1H-2,30-31 | Working (W) | Event Bed 2 | 1.305 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0604 | 0.2206 | 0.2695 | 0.2018 | 0.1314 | 0.0823 | 0.0339 |
| 386-M0089D | 38.7205 | 144.1251 | 2021-05-10 | -7607 | 386-M0089D-1H-2,47-48 | Working (W) | Event Bed 2 | 1.475 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0053 | 0.1078 | 0.2304 | 0.2320 | 0.1790 | 0.1266 | 0.0821 | 0.0368 |
| 386-M0089D | 38.7205 | 144.1251 | 2021-05-10 | -7607 | 386-M0089D-1H-2,54-56 | Working (W) | 1.545 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0025 | 0.1567 | 0.3357 | 0.2082 | 0.1021 | 0.0755 | 0.0584 | 0.0417 | 0.0191 | |
| 386-M0089D | 38.7205 | 144.1251 | 2021-05-10 | -7607 | 386-M0089D-1H-2,58-59 | Working (W) | 1.585 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0283 | 0.1093 | 0.1786 | 0.1953 | 0.1777 | 0.1524 | 0.1105 | 0.0478 | |
| 386-M0089D | 38.7205 | 144.1251 | 2021-05-10 | -7607 | 386-M0089D-1H-2,66-67 | Working (W) | 1.665 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0057 | 0.0134 | 0.0628 | 0.1521 | 0.2032 | 0.2044 | 0.1796 | 0.1263 | 0.0525 | |
| 386-M0089D | 38.7205 | 144.1251 | 2021-05-10 | -7607 | 386-M0089D-1H-4,3-5 | Working (W) | Event Bed 3 | 3.055 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0004 | 0.0108 | 0.0572 | 0.1351 | 0.1810 | 0.1921 | 0.1930 | 0.1577 | 0.0726 |
| 386-M0090A | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090A-1P-1,7-8 | Working (W) | Event Bed 1 | 0.070 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0006 | 0.0336 | 0.0990 | 0.1659 | 0.1972 | 0.1968 | 0.1625 | 0.1042 | 0.0402 |
| 386-M0090A | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090A-1P-1,19-20 | Working (W) | Event Bed 1 | 0.190 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0103 | 0.0582 | 0.1892 | 0.2522 | 0.1818 | 0.1288 | 0.0952 | 0.0598 | 0.0244 |
| 386-M0090A | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090A-1P-1,30-31 | Working (W) | Event Bed 1 | 0.300 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0045 | 0.0184 | 0.0661 | 0.1892 | 0.2481 | 0.2127 | 0.1501 | 0.0826 | 0.0283 |
| 386-M0090A | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090A-1P-1,50-51 | Working (W) | Event Bed 1 | 0.500 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0065 | 0.0411 | 0.1393 | 0.2099 | 0.1795 | 0.1548 | 0.1342 | 0.0945 | 0.0402 |
| 386-M0090A | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090A-1P-1,54-55 | Working (W) | 0.540 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0006 | 0.0146 | 0.0670 | 0.1669 | 0.2160 | 0.2038 | 0.1690 | 0.1153 | 0.0468 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,5-6 | Working (W) | Event Bed 2 | 0.050 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0005 | 0.0084 | 0.0618 | 0.1524 | 0.2128 | 0.2077 | 0.1736 | 0.1267 | 0.0560 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,31-33 | Working (W) | Event Bed 2 | 0.310 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.1351 | 0.4250 | 0.2305 | 0.0655 | 0.0565 | 0.0412 | 0.0309 | 0.0153 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,42-43 | Working (W) | Event Bed 2 | 0.420 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0103 | 0.0999 | 0.2220 | 0.1881 | 0.1394 | 0.1240 | 0.1040 | 0.0769 | 0.0354 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,45-46 | Working (W) | 0.450 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0160 | 0.1429 | 0.2095 | 0.2017 | 0.1664 | 0.1324 | 0.0921 | 0.0390 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,67-68 | Working (W) | 0.670 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0021 | 0.0444 | 0.1331 | 0.2026 | 0.2171 | 0.1930 | 0.1441 | 0.0635 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,70-71 | Working (W) | 0.700 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0066 | 0.0912 | 0.1950 | 0.2232 | 0.1915 | 0.1491 | 0.1001 | 0.0433 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,76-77 | Working (W) | 0.760 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0110 | 0.0718 | 0.1721 | 0.2185 | 0.1987 | 0.1627 | 0.1151 | 0.0501 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,87-88 | Working (W) | 0.870 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0282 | 0.1451 | 0.2446 | 0.2005 | 0.1356 | 0.1142 | 0.0892 | 0.0427 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,92-93 | Working (W) | 0.920 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0001 | 0.0380 | 0.1017 | 0.1572 | 0.1892 | 0.1782 | 0.1583 | 0.1212 | 0.0562 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-1,93-94 | Working (W) | 0.930 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0009 | 0.0444 | 0.0981 | 0.1397 | 0.1782 | 0.1808 | 0.1680 | 0.1308 | 0.0592 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-11,39-41 | Working (W) | 10.640 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0587 | 0.2769 | 0.2754 | 0.1403 | 0.0949 | 0.0752 | 0.0535 | 0.0250 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,2-3 | Working (W) | Event Bed 3 | 1.035 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0001 | 0.1561 | 0.3936 | 0.1758 | 0.0674 | 0.0725 | 0.0609 | 0.0496 | 0.0239 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,12-14 | Working (W) | Event Bed 3 | 1.135 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0013 | 0.1901 | 0.4182 | 0.1992 | 0.0620 | 0.0496 | 0.0372 | 0.0290 | 0.0135 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,24-26 | Working (W) | Event Bed 3 | 1.255 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0117 | 0.1180 | 0.3231 | 0.2321 | 0.0934 | 0.0814 | 0.0687 | 0.0495 | 0.0221 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,37-39 | Working (W) | Event Bed 3 | 1.385 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0728 | 0.3036 | 0.2682 | 0.1174 | 0.0823 | 0.0718 | 0.0565 | 0.0274 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,42-43 | Working (W) | Event Bed 3 | 1.435 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0037 | 0.0363 | 0.0997 | 0.1697 | 0.1905 | 0.1778 | 0.1559 | 0.1153 | 0.0511 |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,46-47 | Working (W) | 1.475 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0037 | 0.0000 | 0.0000 | 0.0044 | 0.0448 | 0.1306 | 0.2014 | 0.2156 | 0.1939 | 0.1433 | 0.0623 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,52-54 | Working (W) | 1.535 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0202 | 0.0886 | 0.1817 | 0.2062 | 0.1780 | 0.1557 | 0.1172 | 0.0522 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,63-65 | Working (W) | 1.645 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0005 | 0.0298 | 0.1149 | 0.1902 | 0.1974 | 0.1665 | 0.1428 | 0.1084 | 0.0495 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-2,92-94 | Working (W) | 1.935 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0008 | 0.0134 | 0.0648 | 0.1624 | 0.2124 | 0.1950 | 0.1676 | 0.1270 | 0.0565 | |
| 386-M0090B | 38.2972 | 144.0591 | 2021-05-18 | -7445 | 386-M0090B-1H-3,30-32 | Working (W) | 2.325 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0023 | 0.0182 | 0.0629 | 0.1591 | 0.2133 | 0.2035 | 0.1730 | 0.1198 | 0.0478 | |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-4,61-63 | Working (W) | Event Bed 3 | 2.975 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0422 | 0.2513 | 0.3080 | 0.1434 | 0.0789 | 0.0695 | 0.0544 | 0.0375 | 0.0148 |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-7,71-73 | Working (W) | 6.095 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0269 | 0.1139 | 0.1194 | 0.1613 | 0.1911 | 0.1696 | 0.1246 | 0.0701 | 0.0230 | |
| 386-M0090D | 38.2953 | 144.0588 | 2021-05-28 | -7450 | 386-M0090D-1H-9,63-65 | Working (W) | 8.080 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0112 | 0.0898 | 0.1419 | 0.1769 | 0.1936 | 0.1793 | 0.1260 | 0.0638 | 0.0175 | |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-8,70-72 | Working (W) | 7.665 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0003 | 0.0536 | 0.2026 | 0.2258 | 0.1599 | 0.1280 | 0.1108 | 0.0825 | 0.0365 | |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-13,53-55 | Working (W) | Event Bed 3 | 12.555 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0006 | 0.0608 | 0.1818 | 0.1658 | 0.1354 | 0.1436 | 0.1417 | 0.1151 | 0.0551 |
| 386-M0091B | 37.4124 | 143.7288 | 2021-05-19 | -7802 | 386-M0091B-1H-14,0-2 | Working (W) | Event Bed 3 | 13.035 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0002 | 0.0136 | 0.0928 | 0.2656 | 0.2274 | 0.1096 | 0.0848 | 0.0764 | 0.0656 | 0.0460 | 0.0181 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-5,86-88 | Working (W) | 4.140 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0168 | 0.1266 | 0.2014 | 0.1955 | 0.1720 | 0.1436 | 0.1006 | 0.0435 | |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-7,58-60 | Working (W) | Event Bed 2 | 5.875 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0000 | 0.0270 | 0.1745 | 0.2300 | 0.1793 | 0.1447 | 0.1189 | 0.0866 | 0.0392 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-8,44-46 | Working (W) | 6.740 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0021 | 0.0196 | 0.0699 | 0.1575 | 0.2119 | 0.2058 | 0.1714 | 0.1151 | 0.0467 | |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-10,16-18 | Working (W) | Event Bed 3 | 8.475 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0024 | 0.0659 | 0.2266 | 0.2298 | 0.1377 | 0.1123 | 0.1046 | 0.0826 | 0.0380 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,48-50 | Working (W) | Event Bed 3 | 12.830 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0028 | 0.1128 | 0.2542 | 0.1784 | 0.1141 | 0.1095 | 0.1038 | 0.0845 | 0.0399 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-14,76-78 | Working (W) | Event Bed 3 | 13.110 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0020 | 0.0938 | 0.2251 | 0.2016 | 0.1323 | 0.1015 | 0.0888 | 0.0763 | 0.0551 | 0.0236 |
| 386-M0091D | 37.4124 | 143.7290 | 2021-05-20 | -7812 | 386-M0091D-1H-15,64-66 | Working (W) | 14.000 | Laser diffraction analyzer (Malvern Mastersizer 3000) | 0.0000 | 0.0000 | 0.0002 | 0.0215 | 0.0894 | 0.1730 | 0.2040 | 0.1844 | 0.1564 | 0.1175 | 0.0536 |
