Geyer, Florian (2025): Basic measurements of radiation at station Sonnblick (2025-08) [dataset]. GeoSphere Austria, PANGAEA, https://doi.org/10.1594/PANGAEA.987372, In: Olefs, Marc (2022): Basic measurements of radiation at station Sonnblick (2013-01 et seq) [dataset publication series]. Zentralanstalt für Meteorologie und Geodynamik, Wien, PANGAEA, https://doi.org/10.1594/PANGAEA.946389
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2025-11-10 • DOI registered: 2025-12-09
Other version:
Geyer, Florian (2025): BSRN Station-to-archive file for station Sonnblick (2025-08) [dataset]. ftp://ftp.bsrn.awi.de/son/son0825.dat.gz
Project(s):
Coverage:
Latitude: 47.054000 * Longitude: 12.957700
Date/Time Start: 2025-08-01T00:00:00 * Date/Time End: 2025-08-31T23:59:00
Minimum HEIGHT above ground: 2 m * Maximum HEIGHT above ground: 2 m
Event(s):
SON (Sonnblick) * Latitude: 47.054000 * Longitude: 12.957700 * Date/Time: 2013-01-01T00:00:00 * Elevation: 3108.9 m * Location: Austria * Method/Device: Monitoring station (MONS) * Comment: BSRN station no: 75; Surface Type: rock; Topography type: mountain top, rural; Horizon: doi:10.1594/PANGAEA.808997; Station scientist: Marc Olefs (marc.olefs@geosphere.at)
Comment:
DIFF downtime on 2025/08/12, therefore no check possible.
Suntracker failure, therefore no DIR or DIF values valid from 2025/08/17 to 2025/08/26
Change of suntracker on 2025/08/26 (morning)
Icing of LW dome on 2025/08/31 (morning)
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | DATE/TIME | Date/Time | Geyer, Florian | Geocode | ||
| 2 | HEIGHT above ground | Height | m | Geyer, Florian | Geocode | |
| 3 | Short-wave downward (GLOBAL) radiation | SWD | W/m2 | Geyer, Florian | Pyranometer, Hukseflux, SR30, SN 6352, WRMC No. 75051 | |
| 4 | Short-wave downward (GLOBAL) radiation, standard deviation | SWD std dev | W/m2 | Geyer, Florian | Pyranometer, Hukseflux, SR30, SN 6352, WRMC No. 75051 | |
| 5 | Short-wave downward (GLOBAL) radiation, minimum | SWD min | W/m2 | Geyer, Florian | Pyranometer, Hukseflux, SR30, SN 6352, WRMC No. 75051 | |
| 6 | Short-wave downward (GLOBAL) radiation, maximum | SWD max | W/m2 | Geyer, Florian | Pyranometer, Hukseflux, SR30, SN 6352, WRMC No. 75051 | |
| 7 | Direct radiation | DIR | W/m2 | Geyer, Florian | Pyrheliometer, Hukseflux, DR02-T2-10, SN 9120, WRMC No. 75053 | |
| 8 | Direct radiation, standard deviation | DIR std dev | W/m2 | Geyer, Florian | Pyrheliometer, Hukseflux, DR02-T2-10, SN 9120, WRMC No. 75053 | |
| 9 | Direct radiation, minimum | DIR min | W/m2 | Geyer, Florian | Pyrheliometer, Hukseflux, DR02-T2-10, SN 9120, WRMC No. 75053 | |
| 10 | Direct radiation, maximum | DIR max | W/m2 | Geyer, Florian | Pyrheliometer, Hukseflux, DR02-T2-10, SN 9120, WRMC No. 75053 | |
| 11 | Diffuse radiation | DIF | W/m2 | Geyer, Florian | Pyranometer, Hukseflux, SR30, SN 2168, WRMC No. 75052 | |
| 12 | Diffuse radiation, standard deviation | DIF std dev | W/m2 | Geyer, Florian | Pyranometer, Hukseflux, SR30, SN 2168, WRMC No. 75052 | |
| 13 | Diffuse radiation, minimum | DIF min | W/m2 | Geyer, Florian | Pyranometer, Hukseflux, SR30, SN 2168, WRMC No. 75052 | |
| 14 | Diffuse radiation, maximum | DIF max | W/m2 | Geyer, Florian | Pyranometer, Hukseflux, SR30, SN 2168, WRMC No. 75052 | |
| 15 | Long-wave downward radiation | LWD | W/m2 | Geyer, Florian | Pyrgeometer, Kipp & Zonen, CGR4, SN 100175, WRMC No. 75054 | |
| 16 | Long-wave downward radiation, standard deviation | LWD std dev | W/m2 | Geyer, Florian | Pyrgeometer, Kipp & Zonen, CGR4, SN 100175, WRMC No. 75054 | |
| 17 | Long-wave downward radiation, minimum | LWD min | W/m2 | Geyer, Florian | Pyrgeometer, Kipp & Zonen, CGR4, SN 100175, WRMC No. 75054 | |
| 18 | Long-wave downward radiation, maximum | LWD max | W/m2 | Geyer, Florian | Pyrgeometer, Kipp & Zonen, CGR4, SN 100175, WRMC No. 75054 | |
| 19 | Air temperature at 2 m height | T2 | °C | Geyer, Florian | Thermometer | |
| 20 | Humidity, relative | RH | % | Geyer, Florian | Hygrometer (HYGRO) | |
| 21 | Station pressure | PoPoPoPo | hPa | Geyer, Florian | Barometer (BARO) |
License:
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
737918 data points
Download Data
View dataset as HTML (shows only first 2000 rows)