Le Moal, Alexandre; Payton, Laura; Geerebaert, Yannick; Meyer, Bettina; Pogoda, Bernadette; Tran, Damien (2025): Valve behavior of the European flat oyster Ostrea edulis and underwater temperature, recorded during a 18-month in situ experiment in Helgoland, Germany [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.983653, In: Le Moal, A et al. (2025): Valve behavior of the European flat oyster Ostrea edulis and associated underwater sound and temperature data, recorded during a 18-month in situ experiment in Helgoland, Germany [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.983652
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2025-08-28 • DOI registered: 2025-09-26
Abstract:
This dataset shows the hourly valve behavioral data of the 16 oysters Ostrea edulis throughout the 18 months of the experiment (11th of May 2023 - 31st of August 2024) in Helgoland (Margate) as well as the temperature recorded by the HFNI valvometer. The oyster valve behavior is characterized by 3 parameters: the Valve Opening Amplitude (VOA, the percentage of the valve opening relative to maximum opening), the Valve Opening Duration (VOD, the percentage of time that an oyster spends with its valves open), and the VOA/VOD. The data are presented for each oyster and as a group average. Missing data corresponds to the death of the oyster number 7 or to the stop of recording due to electrical failure on the oyster's valvometer electrodes.
Keyword(s):
Project(s):
Coverage:
Latitude: 54.193056 * Longitude: 7.879167
Date/Time Start: 2024-03-11T00:00:00 * Date/Time End: 2025-09-01T00:00:00
Event(s):
Comment:
The project was supported by the "PHC PROCOPE" program via the project "OysterClock" (project-ID: 57701739), funded by the French Ministry for Europe and Foreign Affairs, the French Ministry for Higher Education and Research and the German Academic Exchange Service (DAAD)
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | Type of study | Study type | Le Moal, Alexandre | |||
| 2 | Species, unique identification | Species UID | Le Moal, Alexandre | |||
| 3 | Sampling date/time, experiment | Date/time sampling exp | Le Moal, Alexandre | |||
| 4 | Latitude of event | Latitude | Le Moal, Alexandre | |||
| 5 | Longitude of event | Longitude | Le Moal, Alexandre | |||
| 6 | Site | Site | Le Moal, Alexandre | |||
| 7 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 1 |
| 8 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 2 |
| 9 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 3 |
| 10 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 4 |
| 11 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 5 |
| 12 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 6 |
| 13 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 8 |
| 14 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 9 |
| 15 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 10 |
| 16 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 11 |
| 17 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 12 |
| 18 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 13 |
| 19 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 14 |
| 20 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 15 |
| 21 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | Individual 16 |
| 22 | Valve opening amplitude | VOA | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | mean population |
| 23 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 1 |
| 24 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 2 |
| 25 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 3 |
| 26 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 4 |
| 27 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 5 |
| 28 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 6 |
| 29 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 8 |
| 30 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 9 |
| 31 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 10 |
| 32 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 11 |
| 33 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 12 |
| 34 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 13 |
| 35 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 14 |
| 36 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 15 |
| 37 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 16 |
| 38 | Valve opening duration | VOD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | mean population |
| 39 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 1 |
| 40 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 2 |
| 41 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 3 |
| 42 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 4 |
| 43 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 5 |
| 44 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 6 |
| 45 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 8 |
| 46 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 9 |
| 47 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 10 |
| 48 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 11 |
| 49 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 12 |
| 50 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 13 |
| 51 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 14 |
| 52 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 15 |
| 53 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | individual 16 |
| 54 | Valve opening amplitude/Valve opening duration | VOA/VAD | % | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer | mean population |
| 55 | Temperature, water | Temp | °C | Le Moal, Alexandre | High-frequency, non-invasive (HFNI) valvometer |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
653797 data points
Download Data (login required; moratorium until 2027-07-10)
View dataset as HTML (shows only first 2000 rows)
