Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Tran, Damien; Botté, Audrey; Geerebaert, Yannick; Payton, Laura (2025): Hourly sound pressure magnitude data measured underwater on oyster tables during a one-year semi-controlled experiment [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.983304, In: Tran, D et al. (2025): Valve behavior of the oysters Crassostrea gigas and Ostrea edulis and physicochemical data measured during a one-year semi-controlled experiment testing the in situ impact of artificial light at night [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.983250

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2025-06-20DOI registered: 2025-07-19

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Abstract:
This dataset shows the hourly sound pressure magnitude data measured underwater on each oyster table (control and ALAN conditions, at the oyster's level) throughout the year of experiment for different frequencies (10 Hz, 20 Hz, 30 Hz, 40 Hz, 50 Hz, 60 Hz, 70 Hz, 80 Hz, 90 Hz, 100 Hz, 200 Hz, 300Hz, 400 Hz, 500 Hz, 600 Hz, and 700 Hz). The mean sound pressure magnitude is also presented for each condition. In the ALAN condition, data are missing from August 13, 2024, until the end of the experiment due to the failure of the hydrophone used.
Keyword(s):
Arcachon Bay; Artificial Light at Night; Crassostrea gigas; Field experiment; Ostrea edulis; Oyster; physiochemical parameters; valve behavior
Funding:
Agence Nationale de la Recherche (ANR), grant/award no. ANR-22-CE34-0010-01: Light pollution impacts on organisms living In coastal environments – LUCIOLE
Coverage:
Latitude: 44.697468 * Longitude: -1.184233
Event(s):
LUCIOLE_Ile_aux_oiseaux * Latitude: 44.697468 * Longitude: -1.184233 * Location: Arcachon Bay, France * Method/Device: Field experiment
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Type of studyStudy typeTran, Damien
2Sampling date/time, experimentDate/time sampling expTran, Damien
3LATITUDELatitudeTran, DamienGeocode
4LONGITUDELongitudeTran, DamienGeocode
5SiteSiteTran, Damien
6Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 10 Hz
7Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 20 Hz
8Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 30 Hz
9Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 40 Hz
10Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 50 Hz
11Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 60 Hz
12Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 70 Hz
13Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 80 Hz
14Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 90 Hz
15Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 100 Hz
16Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 200 Hz
17Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 300 Hz
18Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 400 Hz
19Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 500 Hz
20Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 600 Hz
21Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, 700 Hz
22Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 1, control site, mean
23Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 10 Hz
24Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 20 Hz
25Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 30 Hz
26Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 40 Hz
27Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 50 Hz
28Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 60 Hz
29Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 70 Hz
30Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 80 Hz
31Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 90 Hz
32Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 100 Hz
33Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 200 Hz
34Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 300 Hz
35Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 400 Hz
36Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 500 Hz
37Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 600 Hz
38Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2, ALAN exposure site, 700 Hz
39Sound pressure magnitudepdB re 1 µPaBotté, AudreyHydrophone, Aquarian Audio Products, H2dHydrophone 2,ALAN exposure site, mean
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
276337 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)