Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Czymzik, Markus; Christl, Marcus; Arz, Helge Wolfgang (2025): Fe and Zr/Rb XRF data from Black Sea sediment core M72/5-22GC-8 during Termination 2 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.982488

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2025-05-13DOI registered: 2025-05-14

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Abstract:
Fe and Zr/Rb records spanning Termination 2 were obtained from Black Sea sediment core M72/5-22GC-8 (803.75 -941.75 cm core depth) at 500 µm resolution using an ITRAX core scanner equipped with a Cr tube at 30 kV, 30 mA and with 15 seconds dwell time in 2020. Sediment core M72/5-22GC-8 was recovered from the south-eastern Black Sea (Archangelsky Ridge, 42°13.5'N, 36°29.6'E, 847 m bsl.) using a gravity corer during RV Meteor cruise M72/5 in 2007. Primary objective of the measurements was to establish time-series of multi-decadal element variability.
Keyword(s):
Black Sea; Fe; Sediment core; Termination 2; XRF; Zr/Rb
Related to:
Czymzik, Markus; Christl, Marcus; Arz, Helge Wolfgang (accepted): Cosmogenic production, sea level and tephra signals in 10Be from Black Sea sediments during Termination 2. Geophysical Research Letters
Funding:
German Research Foundation (DFG), grant/award no. CZ227/5-1: SolClim
Coverage:
Latitude: 42.225500 * Longitude: 36.493170
Date/Time Start: 2007-05-31T11:27:00 * Date/Time End: 2007-05-31T11:27:00
Minimum DEPTH, sediment/rock: 8.0375 m * Maximum DEPTH, sediment/rock: 9.4175 m
Event(s):
M72/5_640-1 (22-GC8) * Latitude: 42.225500 * Longitude: 36.493170 * Date/Time: 2007-05-31T11:27:00 * Elevation: -847.0 m * Recovery: 945 cm * Location: Black Sea * Campaign: M72/5 * Basis: Meteor (1986) * Method/Device: Gravity corer (GC)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, sediment/rockDepth sedmCzymzik, MarkusGeocode
2IronFecpsCzymzik, MarkusX-ray fluorescence scanner (XRF), COX, ITRAX [0.05 cm resolution, 15 seconds integration time, Cr X-ray tube at 30 kV and 30 mA]
3ln-Zirconium/Rubidium ratioln(Zr/Rb)Czymzik, MarkusX-ray fluorescence scanner (XRF), COX, ITRAX [0.05 cm resolution, 15 seconds integration time, Cr X-ray tube at 30 kV and 30 mA]
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
5458 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)