Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Schaaff, Valentine; Grossi, Vincent; Makou, Matthew; Garcin, Yannick; Deschamps, Pierre; Hamelin, Bruno; Kiahtipes, Christopher Albert; Sebag, David; Ngounou Ngatcha, Benjamin; Ménot, Guillemette (2025): Isotopic lipid biomarker from the NGaoundaba peat deposit (Tropical Africa) covering the Holocene [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.979863

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2025-03-31DOI registered: 2025-03-31

RIS CitationBibTeX Citation Copy Citation ShareShow MapGoogle Earth 11 1 2

Abstract:
This dataset includes lipid biomarker data from a peat sequence (named NGBA19) collected at the NGaoundaba peat deposit in 2019. The NGaoundaba peat deposit is located in North East Cameroon (N 7.135°, E 13.690°, 1175 m a.s.l). The 6-meter core was collected using a Russian peat corer. The core was subsampled at 2.5-cm intervals. Analyses were performed on 73 samples. Measurements were performed between 2020 and 2024 at the LGL-TPE (University Claude Bernard Lyon 1). The NGBA19 core covers the last 10 ka (detail on the datation method and results are given in Schaaff et al. (2023, doi:10.1016/j.orggeochem.2023.104589). This dataset is associated to a publication: Sensitivity to climate and vegetation dynamics of a peatland record from Central Cameroon during the African Humid Period (QSR). The publication details the full method used to obtain the data. The study focus on paleoclimatic and paleoenvironmental reconstructions particularly during and after the African Humid Period. This file contains long-chain n-alkanes carbon and hydrogen isotopic composition. Isotopic compositions are given as δ13C and δD for carbon and hydrogen, respectively. These data were collected using GC-IRMS. Uncertainties were calculated based on duplicate measurements of each sample. When the concentration of the sample did not allow duplicate measurement, the uncertainty corresponds to the mean value of all measured samples. The carbon isotopic compositions are corrected for Suess effect. We provided both uncorrected δD values(δDuncorr) and δD values corrected for vegetation change (δDcorr). Correction methods are presented in detail in the associated article.
Keyword(s):
African Humid Period; alkanes; Biomarker; GDGT; pollen analysis; Tropical peatlands
Supplement to:
Schaaff, Valentine; Grossi, Vincent; Makou, Matthew; Garcin, Yannick; Deschamps, Pierre; Hamelin, Bruno; Kiahtipes, Christopher Albert; Sebag, David; Ngounou Ngatcha, Benjamin; Ménot, Guillemette (in review): Sensitivity to climate and vegetation dynamics of a peatland record from Central Cameroon during the African Humid Period. Quaternary Science Reviews
Funding:
Agence Nationale de la Recherche (ANR), grant/award no. ANR-18-CE01-0005: ANR TAPIOCA
Coverage:
Latitude: 7.135000 * Longitude: 13.690000
Date/Time Start: 2019-02-01T00:00:00 * Date/Time End: 2019-02-01T00:00:00
Minimum DEPTH, sediment/rock: 0.100 m * Maximum DEPTH, sediment/rock: 5.900 m
Event(s):
NGBA19 * Latitude: 7.135000 * Longitude: 13.690000 * Date/Time: 2019-02-01T00:00:00 * Elevation: 1175.0 m * Location: NGaoundaba peatland, Northeastern Cameroon * Method/Device: Core (CORE)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, sediment/rockDepth sedmSchaaff, ValentineGeocode
2AGEAgeka BPSchaaff, ValentineAge, 14C calibratedGeocode
3n-Alkane C29, δ13CC29 δ13C‰ PDBSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)
4n-Alkane C29, δ13C, uncertaintyC29 δ13C uncSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Based on duplicate analyses. Uncertainty 2*∆/√2
5n-Alkane C31, δ13CC31 δ13C‰ PDBSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)
6n-Alkane C31, δ13C, uncertaintyC31 δ13C uncSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Based on duplicate analyses. Uncertainty 2*∆/√2
7n-Alkane C33, δ13CC33 δ13C‰ PDBSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)
8n-Alkane C33, δ13C, uncertaintyC33 δ13C uncSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Based on duplicate analyses. Uncertainty 2*∆/√2
9δ Deuterium, n-alkanes, C29δD n-alkanes C29Schaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Uncorrected
10δ Deuterium, n-alkanes, C29, uncertaintyδD n-alkanes C29 uncSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Uncorrected - based on duplicate analyses. Uncertainty 2*∆/√2.
11δ Deuterium, n-alkanes, C31δD n-alkanes C31Schaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Uncorrected
12δ Deuterium, n-alkanes, C31, uncertaintyδD n-alkanes C31 uncSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Uncorrected - based on duplicate analyses. Uncertainty 2*∆/√2.
13δ Deuterium, n-alkanes, C33δD n-alkanes C33Schaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Uncorrected
14δ Deuterium, n-alkanes, C33, uncertaintyδD n-alkanes C33 uncSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Uncorrected - based on duplicate analyses. Uncertainty 2*∆/√2.
15δ Deuterium, n-alkanes, C29δD n-alkanes C29Schaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Corrected
16δ Deuterium, n-alkanes, C29, uncertaintyδD n-alkanes C29 uncSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Corrected - based on duplicate analyses. Uncertainty 2*∆/√2.
17δ Deuterium, n-alkanes, C31δD n-alkanes C31Schaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Corrected
18δ Deuterium, n-alkanes, C31, uncertaintyδD n-alkanes C31 uncSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Corrected - based on duplicate analyses. Uncertainty 2*∆/√2.
19δ Deuterium, n-alkanes, C33δD n-alkanes C33Schaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Corrected
20δ Deuterium, n-alkanes, C33, uncertaintyδD n-alkanes C33 uncSchaaff, ValentineGas chromatography combustion isotope ratio mass spectrometery (GC-C-IRMS), Agilent Technologies 7890B, coupled to an Isoprime visION IRMS via an Isoprime GC-5 combustion interface (Elementar)Corrected - based on duplicate analyses. Uncertainty 2*∆/√2.
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1268 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML