Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science
Abstract:
Results of interstitial water (IW) geochemistry analyses from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). The offshore phase of this expedition took place between 2021-04-13 and 2021-06-01 onboard Japanese R/V Kaimei from and to Yokosuka, Japan, followed by an onshore phase onboard D/V Chikyu between 2022-02-14 – 2022-03-15. Sampling for IW geochemistry took place offshore immediately upon core recovery using Rhizon samplers. A total amount of approximately 15 mL IW per sample were extracted from the core sections over a maximum rhizon retention time of 6 hours. IW main samples were subsequently split into as many as seven fractions for the following IODP standard measurements: sulfide (1.5 mL IW + 0.6 mL ZnAc 2.5%), salinity (0.5–1.5 mL), pH and alkalinity (3–4 mL), ammonium (0.5–1.5 mL), cations (3 mL IW + 0.03 mL HNO3), and anions (3 mL). In addition to IW from the core sections, samples of the bottom water (BW) were collected from the top of the trigger core using a Duran bottle and vacuum pump unit connected by tubes.
For further methodological information see methods chapter in Strasser, M. et al., 2023 https://doi.org/10.14379/iodp.proc.386.102.2023
Keyword(s):
International Ocean Discovery Program (IODP); IODP; Japan Trench; Porewater chemistry
Related to:
Strasser, Michael; Ikehara, Ken; Everest, Jeremy D; IODP Expedition 386 Scientists (2023): Japan Trench Paleoseismology. Proceedings of the International Ocean Discovery Program, International Ocean Discovery Program, 386, https://doi.org/10.14379/iodp.proc.386.2023
Coverage:
Latitude: 38.295317 * Longitude: 144.058800
Date/Time Start: 2021-05-28T00:00:00 * Date/Time End: 2021-05-28T00:00:00
Minimum DEPTH, sediment/rock: 0.35 m * Maximum DEPTH, sediment/rock: 32.39 m
Event(s):
386-M0090D (JTPC-03B)  * Latitude: 38.295317 * Longitude: 144.058800 * Date/Time Start: 2021-05-28T00:00:00 * Date/Time End: 2021-05-28T00:00:00 * Elevation: -7450.0 m * Location: Japan Trench * Campaign: Exp386 * Basis: Kaimei * Method/Device: Giant piston corer (GPC) * Comment: IGSN: IBCR0386EH07001. Comment: 40 m. Location: applied ship's position due to malfunctioning GPC transponder.
Comment:
Data was submitted and proofread by Vera Barbara Bender, MARUM - Center for Marine Environmental Sciences (University Bremen) on behalf of ECORD Science Operator Data Management (https://www.ecord.org).
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Event labelEvent
Sample code/labelSample labelDSDP/ODP/IODP sample designation
Proposed International Geo Sample NumberProp IGSN
DEPTH, sediment/rockDepth sedmGeocode
Salinity, porewaterSal pwRefractometer, Atago, RX-5000idetermined based on refractive index
Alkalinity, totalATmmol(eq)/lTitration, Metrohm, 888 Titrando
Ammonium[NH4]+mmol/lDiscrete analyzer for colorimetric analysis, SEAL Analytical, AQ2
VanadiumVnmol/lInductively coupled plasma-mass spectroscopy (ICP-MS), Agilent, 7500-ce
CopperCunmol/lInductively coupled plasma-mass spectroscopy (ICP-MS), Agilent, 7500-ce
10 RubidiumRbnmol/lInductively coupled plasma-mass spectroscopy (ICP-MS), Agilent, 7500-ce
11 MolybdenumMonmol/lInductively coupled plasma-mass spectroscopy (ICP-MS), Agilent, 7500-ce
12 UraniumUnmol/lInductively coupled plasma-mass spectroscopy (ICP-MS), Agilent, 7500-ce
13 LithiumLiµmol/lInductively coupled plasma-atomic emission spectrometer (ICP-AES), Horiba Jobin Yvon, ULTIMA 2
14 BoronBµmol/lInductively coupled plasma-atomic emission spectrometer (ICP-AES), Horiba Jobin Yvon, ULTIMA 2
15 SiliconSiµmol/lInductively coupled plasma-atomic emission spectrometer (ICP-AES), Horiba Jobin Yvon, ULTIMA 2
16 ManganeseMnµmol/lInductively coupled plasma-atomic emission spectrometer (ICP-AES), Horiba Jobin Yvon, ULTIMA 2
17 IronFeµmol/lInductively coupled plasma-atomic emission spectrometer (ICP-AES), Horiba Jobin Yvon, ULTIMA 2
18 StrontiumSrµmol/lInductively coupled plasma-atomic emission spectrometer (ICP-AES), Horiba Jobin Yvon, ULTIMA 2
19 BariumBaµmol/lInductively coupled plasma-atomic emission spectrometer (ICP-AES), Horiba Jobin Yvon, ULTIMA 2
20 ChlorineClmmol/lIon chromatograph (IC), Metrohm, 882 Compact
21 BromineBrmmol/lIon chromatograph (IC), Metrohm, 882 Compact
22 Sulfate[SO4]2-mmol/lIon chromatograph (IC), Metrohm, 882 Compact
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
500 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Event

Sample label

Prop IGSN

Depth sed [m]

Sal pw

AT [mmol(eq)/l]

[NH4]+ [mmol/l]

V [nmol/l]

Cu [nmol/l]
10 
Rb [nmol/l]
11 
Mo [nmol/l]
12 
U [nmol/l]
13 
Li [µmol/l]
14 
B [µmol/l]
15 
Si [µmol/l]
16 
Mn [µmol/l]
17 
Fe [µmol/l]
18 
Sr [µmol/l]
19 
Ba [µmol/l]
20 
Cl [mmol/l]
21 
Br [mmol/l]
22 
[SO4]2- [mmol/l]
386-M0090D 386-M0090D-1H-1,35-35IBCR0386EX20F010.3534.2421.481.10142.535.5155944.909.6120.5493885195.013.784.70.75490.89616.9
386-M0090D386-M0090D-1H-2,20-20IBCR0386EX30F010.7134.2421.301.26157.427.0157970.4013.7121.0504850181.014.588.21.65440.88016.8
386-M0090D386-M0090D-1H-2,70-70IBCR0386EX40F011.2133.9730.311.65172.224.8161423.7010.3220.0544868169.05.885.01.15430.88710.8
386-M0090D386-M0090D-1H-3,35-35IBCR0386EX50F011.7134.1834.992.01190.324.3160526.8011.4018.9553872131.04.287.81.45420.8847.8
386-M0090D386-M0090D-1H-3,85-85IBCR0386EX60F012.2134.0739.372.25204.235.115625.9414.2918.0572871125.06.188.41.55470.9094.9
386-M0090D386-M0090D-1H-4,35-35IBCR0386EX70F012.7233.9141.062.38200.416.2155316.309.6117.757679496.48.288.11.95470.9044.0
386-M0090D386-M0090D-1H-4,85-85IBCR0386EX80F013.2234.1844.232.63232.727.0152011.5010.6317.059682887.18.090.53.45460.8912.4
386-M0090D386-M0090D-1H-5,35-35IBCR0386EXZ0F013.7334.1847.182.77243.329.115367.8912.1515.760385288.76.894.97.35460.9131.1
386-M0090D386-M0090D-1H-5,85-85IBCR0386EX90F014.2334.3447.993.07157.251.915248.779.8414.966385875.25.893.516.05470.8880.6
386-M0090D386-M0090D-1H-6,85-85IBCR0386EXA0F015.2334.4551.483.00198.749.614818.320.3613.269785662.75.794.244.25480.8730.2
386-M0090D386-M0090D-1H-7,85-85IBCR0386EXB0F016.2434.5652.823.24194.752.714579.570.2012.771884650.05.8103.355.25470.9360.1
386-M0090D386-M0090D-1H-8,86-86IBCR0386EXC0F017.3034.6753.573.43186.953.7150713.700.2713.076084849.47.498.557.25460.9350.5
386-M0090D386-M0090D-1H-9,87-87IBCR0386EXD0F018.3234.4555.083.72179.356.315118.950.3113.077885051.09.999.459.25430.9320.3
386-M0090D386-M0090D-1H-10,89-89IBCR0386EXE0F019.3634.2450.833.81162.548.5146425.800.1013.675782447.27.4101.957.85400.9012.6
386-M0090D386-M0090D-1H-12,86-86IBCR0386EXF0F0111.3834.8858.864.44163.948.114989.880.1814.280481142.611.397.859.45360.9280.3
386-M0090D386-M0090D-1H-14,90-90IBCR0386EXG0F0113.4434.9961.214.77139.156.415007.360.1514.983178529.914.298.057.85430.9340.2
386-M0090D386-M0090D-1H-16,91-91IBCR0386EXH0F0115.5135.0563.615.08145.844.8148112.600.4815.184276516.925.198.661.55410.9570.1
386-M0090D386-M0090D-1H-18,82-82IBCR0386EXI0F0117.5435.1664.865.66179.952.6151012.600.6915.487176520.334.2100.761.45430.9500.1
386-M0090D386-M0090D-1H-20,93-93IBCR0386EXJ0F0119.7735.2665.825.67164.246.614817.750.1014.288375216.622.8101.457.65510.9750.2
386-M0090D386-M0090D-1H-22,89-89IBCR0386EXK0F0121.8635.8067.625.88194.651.615328.430.1314.592377520.260.5102.665.35460.9700.2
386-M0090D386-M0090D-1H-24,91-91IBCR0386EXL0F0123.9735.9769.555.80201.149.6157813.100.1915.191977520.035.0106.370.35550.9870.1
386-M0090D386-M0090D-1H-26,91-91IBCR0386EXM0F0126.1035.8667.855.97230.249.8166946.001.2716.395879817.514.0101.877.35500.9890.0
386-M0090D386-M0090D-1H-28,94-94IBCR0386EXN0F0128.2235.8670.126.21168.345.215909.350.0616.594783915.510.499.077.55490.9800.0
386-M0090D386-M0090D-1H-30,91-91IBCR0386EXO0F0130.3035.8670.377.79176.341.9161855.600.5416.695684912.48.4101.169.45490.9710.0
386-M0090D386-M0090D-1H-32,91-91IBCR0386EXP0F0132.3935.9170.816.4763.454.2159815.300.4715.892779211.825.1103.655.95470.9850.0