Liu, Jia-Hui; Kaempf, Jonas; Huang, Meiyun; Riel, Nicolas; Guo, Jinghui; Huang, Guangyu; Chen, Lin; Jiao, Shujuan; Mao, Mengxia; Clark, Chris; Wang, Juan; Zhang, Qian W L; Peng, Peng (2025): SIMS U-Pb zircon geochronological measurement of the Wutai-Fuping crustal section [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.974550, In: Liu, J-H et al. (2025): Mineral and bulk compositions measured by EPMA, geochronological data measured by LA-ICP-MS and SIMS, for the Wutai-Fuping crustal section [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.974551
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2025-05-12 • DOI registered: 2025-06-10
Abstract:
We measured zircon U-Pb isotope using a Cameca IMS-1280 SIMS mass spectrometer at the Institute of Geology and Geophysics, Chinese Academy of Sciences (IGGCAS), Beijing, China. The measurement was performed in 2024. We present Pb, U, Th isotopes and their ratios.
Keyword(s):
Funding:
Coverage:
Median Latitude: 38.934150 * Median Longitude: 112.994100 * South-bound Latitude: 38.932200 * West-bound Longitude: 112.993800 * North-bound Latitude: 38.936100 * East-bound Longitude: 112.994400
Date/Time Start: 2023-06-13T09:30:00 * Date/Time End: 2023-06-13T11:15:00
Minimum DEPTH, sediment/rock: 0 m * Maximum DEPTH, sediment/rock: 0 m
Event(s):
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Event label | Event | Liu, Jia-Hui | |||
2 | Latitude of event | Latitude | Liu, Jia-Hui | |||
3 | Longitude of event | Longitude | Liu, Jia-Hui | |||
4 | Date/Time of event | Date/Time | Liu, Jia-Hui | |||
5 | DEPTH, sediment/rock | Depth sed | m | Liu, Jia-Hui | Geocode | |
6 | Sample ID | Sample ID | Liu, Jia-Hui | |||
7 | Lead-207/Uranium-235 ratio | 207Pb/235U | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | ||
8 | Lead-207/Uranium-235 ratio, error, relative | 207Pb/235U e rel | % | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | |
9 | Lead-206/Uranium-238 ratio | 206Pb/238U | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | ||
10 | Lead-206/Uranium-238 ratio, error, relative | 206Pb/238U e rel | % | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | |
11 | R-factor | R | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | ||
12 | Discordance | D | % | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | |
13 | Lead-207/Lead-206 ratio | 207Pb/206Pb | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | ||
14 | Lead-207/Lead-206 ratio, error, relative | 207Pb/206Pb e rel | % | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | |
15 | Lead-207/Uranium-235 ratio | 207Pb/235U | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | ||
16 | Lead-207/Uranium-235 ratio, error, relative | 207Pb/235U e rel | % | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | |
17 | Lead-206/Uranium-238 ratio | 206Pb/238U | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | ||
18 | Lead-206/Uranium-238 ratio, error, relative | 206Pb/238U e rel | % | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | |
19 | Uranium | U | mg/kg | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | |
20 | Thorium | Th | mg/kg | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | |
21 | Lead | Pb | mg/kg | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR | |
22 | Thorium/Uranium ratio | Th/U | Liu, Jia-Hui | Secondary ion mass spectrometry (SIMS), Cameca, IMS1280-HR |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
289 data points