Liu, Jia-Hui; Kaempf, Jonas; Huang, Meiyun; Riel, Nicolas; Guo, Jinghui; Huang, Guangyu; Chen, Lin; Jiao, Shujuan; Mao, Mengxia; Clark, Chris; Wang, Juan; Zhang, Qian W L; Peng, Peng (2025): In situ garnet Lu-Hf geochronological data (second measurement) of the Wutai-Fuping crustal section [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.974546, In: Liu, J-H et al. (2025): Mineral and bulk compositions measured by EPMA, geochronological data measured by LA-ICP-MS and SIMS, for the Wutai-Fuping crustal section [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.974551
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2025-05-12 • DOI registered: 2025-06-10
Abstract:
We measured garnet Lu-Hf isotope using a RESOlution 193 nm excimer laser-ablation (LA) system connected to an Agilent 8900 QQQ ICP-MS at the John de Laeter Centre (JdLC) at Curtin University, Australia. The measurement was performed in 2024 July. We present 176Lu/176Hf and 177Hf/176Hf ratios, etc.
Keyword(s):
Funding:
Coverage:
Median Latitude: 38.732550 * Median Longitude: 114.056667 * South-bound Latitude: 38.347500 * West-bound Longitude: 113.916110 * North-bound Latitude: 38.972500 * East-bound Longitude: 114.146110
Date/Time Start: 2015-08-05T14:40:00 * Date/Time End: 2020-07-11T15:10:00
Minimum DEPTH, sediment/rock: 0 m * Maximum DEPTH, sediment/rock: 0 m
Event(s):
Wutai-Fuping_1 * Latitude: 38.972500 * Longitude: 114.107780 * Date/Time: 2015-08-05T14:40:00 * Location: North China * Method/Device: Field sampling, rock hammer
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | Event label | Event | Liu, Jia-Hui | |||
| 2 | Latitude of event | Latitude | Liu, Jia-Hui | |||
| 3 | Longitude of event | Longitude | Liu, Jia-Hui | |||
| 4 | Date/Time of event | Date/Time | Liu, Jia-Hui | |||
| 5 | DEPTH, sediment/rock | Depth sed | m | Liu, Jia-Hui | Geocode | |
| 6 | Sample ID | Sample ID | Liu, Jia-Hui | |||
| 7 | Lutetium-176/Hafnium-176 ratio | 176Lu/177Hf | Liu, Jia-Hui | LA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer (Agilent ICP-QQQ 8900 quadrupole ICP-MS coupled to an Excimer laser ablation system (193 nm wavelength)) | ||
| 8 | Lutetium-176/Hafnium-176 ratio, error | 176Lu/177Hf e | ± | Liu, Jia-Hui | LA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer (Agilent ICP-QQQ 8900 quadrupole ICP-MS coupled to an Excimer laser ablation system (193 nm wavelength)) | |
| 9 | Hafnium-177/Hafnium-176 ratio | 177Hf/176Hf | Liu, Jia-Hui | LA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer (Agilent ICP-QQQ 8900 quadrupole ICP-MS coupled to an Excimer laser ablation system (193 nm wavelength)) | ||
| 10 | Hafnium-177/Hafnium-176 ratio, error | 177Hf/176Hf e | ± | Liu, Jia-Hui | LA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer (Agilent ICP-QQQ 8900 quadrupole ICP-MS coupled to an Excimer laser ablation system (193 nm wavelength)) | |
| 11 | Correlation coefficient, isotope ratio error | Rho | Liu, Jia-Hui | Calculated |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1032 data points
