Liu, Jia-Hui; Kaempf, Jonas; Huang, Meiyun; Riel, Nicolas; Guo, Jinghui; Huang, Guangyu; Chen, Lin; Jiao, Shujuan; Mao, Mengxia; Clark, Chris; Wang, Juan; Zhang, Qian W L; Peng, Peng (2025): In situ garnet Lu-Hf geochronological data (first measurment) of the Wutai-Fuping crustal section [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.974544, In: Liu, J-H et al. (2025): Mineral and bulk compositions measured by EPMA, geochronological data measured by LA-ICP-MS and SIMS, for the Wutai-Fuping crustal section [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.974551
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2025-05-12 • DOI registered: 2025-06-10
Abstract:
We measured garnet Lu-Hf isotope using a RESOlution 193 nm excimer laser-ablation (LA) system connected to an Agilent 8900 QQQ ICP-MS at the John de Laeter Centre (JdLC) at Curtin University, Australia. The measurement was performed in 2024 Feb. We present 176Lu/177Hf and 176Hf/177Hf ratios, etc.
Keyword(s):
Funding:
Coverage:
Median Latitude: 38.934150 * Median Longitude: 112.994100 * South-bound Latitude: 38.932200 * West-bound Longitude: 112.993800 * North-bound Latitude: 38.936100 * East-bound Longitude: 112.994400
Date/Time Start: 2023-06-13T09:30:00 * Date/Time End: 2023-06-13T11:15:00
Minimum DEPTH, sediment/rock: 0 m * Maximum DEPTH, sediment/rock: 0 m
Event(s):
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | Event label | Event | Liu, Jia-Hui | |||
| 2 | Latitude of event | Latitude | Liu, Jia-Hui | |||
| 3 | Longitude of event | Longitude | Liu, Jia-Hui | |||
| 4 | Date/Time of event | Date/Time | Liu, Jia-Hui | |||
| 5 | DEPTH, sediment/rock | Depth sed | m | Liu, Jia-Hui | Geocode | |
| 6 | Sample ID | Sample ID | Liu, Jia-Hui | |||
| 7 | Lutetium-176/Hafnium-177 ratio | 176Lu/177Hf | Liu, Jia-Hui | LA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer (Agilent ICP-QQQ 8900 quadrupole ICP-MS coupled to an Excimer laser ablation system (193 nm wavelength)) | ||
| 8 | Lutetium-176/Hafnium-177 ratio, error | 176Lu/177Hf e | ± | Liu, Jia-Hui | LA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer (Agilent ICP-QQQ 8900 quadrupole ICP-MS coupled to an Excimer laser ablation system (193 nm wavelength)) | 2σ absolute |
| 9 | Hafnium-176/Hafnium-177 ratio | 176Hf/177Hf | Liu, Jia-Hui | LA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer (Agilent ICP-QQQ 8900 quadrupole ICP-MS coupled to an Excimer laser ablation system (193 nm wavelength)) | ||
| 10 | Hafnium-176/Hafnium-177 ratio, error | 176Hf/177Hf e | ± | Liu, Jia-Hui | LA-ICP-MS, Laser-ablation inductively coupled plasma mass spectrometer (Agilent ICP-QQQ 8900 quadrupole ICP-MS coupled to an Excimer laser ablation system (193 nm wavelength)) | 2σ absolute |
| 11 | Correlation coefficient, isotope ratio error | Rho | Liu, Jia-Hui | Calculated |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1140 data points
