van Kaam, Rianne: Grain size distribution of dust samples from ephemeral rivers in Namibia [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.972430 (dataset in review), In: van Kaam, R: Sorption experiments with dissolved organic carbon and characterized dust samples from ephemeral rivers in Namibia [dataset bundled publication]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.972507 (dataset in review)
Keyword(s):
Related to:
van Kaam, Rianne; Kölling, Martin; Elvert, Marcus; Hinrichs, Kai-Uwe; Zabel, Matthias (submitted): Dust deposition directly affects the concentration of dissolved organic carbon in the ocean. Marine Chemistry
Project(s):
Funding:
German Research Foundation (DFG), grant/award no. 390741603: EXC 2077: The Ocean Floor – Earth's Uncharted Interface
Coverage:
Median Latitude: -22.876067 * Median Longitude: 14.727100 * South-bound Latitude: -23.562900 * West-bound Longitude: 14.508400 * North-bound Latitude: -21.899000 * East-bound Longitude: 15.039400
Date/Time Start: 2023-04-22T00:00:00 * Date/Time End: 2023-04-23T00:00:00
Minimum DEPTH, sediment/rock: 0 m * Maximum DEPTH, sediment/rock: 0 m
Event(s):
1-Kuiseb * Latitude: -23.562900 * Longitude: 15.039400 * Date/Time: 2023-04-22T00:00:00 * Location: Kuiseb, Gobabeb, Namibia * Method/Device: Dust sample (DUST)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Event label | Event | van Kaam, Rianne | |||
2 | DEPTH, sediment/rock | Depth sed | m | van Kaam, Rianne | Geocode | |
3 | Size fraction 0.044-0.04 µm | 0.044-0.04 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.04, Grain size (Phi) 14.54 |
4 | Size fraction 0.048-0.044 µm | 0.048-0.044 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.05, Grain size (Phi) 14.41 |
5 | Size fraction 0.053-0.048 µm | 0.053-0.048 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.05, Grain size (Phi) 14.28 |
6 | Size fraction 0.058-0.053 µm | 0.058-0.053 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.06, Grain size (Phi) 14.14 |
7 | Size fraction 0.064-0.058 µm | 0.064-0.058 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.06, Grain size (Phi) 14 |
8 | Size fraction 0.07-0.064 µm | 0.07-0.064 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.07, Grain size (Phi) 13.87 |
9 | Size fraction 0.077-0.07 µm | 0.077-0.07 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.07, Grain size (Phi) 13.73 |
10 | Size fraction 0.084-0.077 µm | 0.084-0.077 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.08, Grain size (Phi) 13.6 |
11 | Size fraction 0.093-0.084 µm | 0.093-0.084 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.09, Grain size (Phi) 13.47 |
12 | Size fraction 0.102-0.093 µm | 0.102-0.093 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.1, Grain size (Phi) 13.33 |
13 | Size fraction 0.112-0.102 µm | 0.112-0.102 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.11, Grain size (Phi) 13.19 |
14 | Size fraction 0.123-0.112 µm | 0.123-0.112 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.12, Grain size (Phi) 13.06 |
15 | Size fraction 0.134-0.123 µm | 0.134-0.123 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.13, Grain size (Phi) 12.93 |
16 | Size fraction 0.148-0.134 µm | 0.148-0.134 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.14, Grain size (Phi) 12.79 |
17 | Size fraction 0.162-0.148 µm | 0.162-0.148 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.15, Grain size (Phi) 12.66 |
18 | Size fraction 0.178-0.162 µm | 0.178-0.162 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.17, Grain size (Phi) 12.52 |
19 | Size fraction 0.195-0.178 µm | 0.195-0.178 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.19, Grain size (Phi) 12.39 |
20 | Size fraction 0.214-0.195 µm | 0.214-0.195 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.2, Grain size (Phi) 12.26 |
21 | Size fraction 0.235-0.214 µm | 0.235-0.214 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.22, Grain size (Phi) 12.12 |
22 | Size fraction 0.258-0.235 µm | 0.258-0.235 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.25, Grain size (Phi) 11.99 |
23 | Size fraction 0.284-0.258 µm | 0.284-0.258 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.27, Grain size (Phi) 11.85 |
24 | Size fraction 0.311-0.284 µm | 0.311-0.284 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.3, Grain size (Phi) 11.72 |
25 | Size fraction 0.342-0.311 µm | 0.342-0.311 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.33, Grain size (Phi) 11.58 |
26 | Size fraction 0.375-0.342 µm | 0.375-0.342 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.36, Grain size (Phi) 11.45 |
27 | Size fraction 0.412-0.375 µm | 0.412-0.375 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.39, Grain size (Phi) 11.31 |
28 | Size fraction 0.452-0.412 µm | 0.452-0.412 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.43, Grain size (Phi) 11.18 |
29 | Size fraction 0.496-0.452 µm | 0.496-0.452 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.47, Grain size (Phi) 11.04 |
30 | Size fraction 0.545-0.496 µm | 0.545-0.496 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.52, Grain size (Phi) 10.91 |
31 | Size fraction 0.598-0.545 µm | 0.598-0.545 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.57, Grain size (Phi) 10.77 |
32 | Size fraction 0.657-0.598 µm | 0.657-0.598 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.63, Grain size (Phi) 10.64 |
33 | Size fraction 0.721-0.657 µm | 0.721-0.657 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.69, Grain size (Phi) 10.5 |
34 | Size fraction 0.791-0.721 µm | 0.791-0.721 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.76, Grain size (Phi) 10.37 |
35 | Size fraction 0.869-0.791 µm | 0.869-0.791 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.83, Grain size (Phi) 10.24 |
36 | Size fraction 0.953-0.869 µm | 0.953-0.869 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 0.91, Grain size (Phi) 10.1 |
37 | Size fraction 1.047-0.954 µm | 1.047-0.954 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1, Grain size (Phi) 9.97 |
38 | Size fraction 1.149-1.047 µm | 1.149-1.047 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1.1, Grain size (Phi) 9.83 |
39 | Size fraction 1.261-1.149 µm | 1.261-1.149 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1.2, Grain size (Phi) 9.7 |
40 | Size fraction 1.385-1.261 µm | 1.385-1.261 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1.32, Grain size (Phi) 9.56 |
41 | Size fraction 1.520-1.385 µm | 1.520-1.385 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1.45, Grain size (Phi) 9.43 |
42 | Size fraction 1.669-1.520 µm | 1.669-1.520 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1.59, Grain size (Phi) 9.29 |
43 | Size fraction 1.832-1.669 µm | 1.832-1.669 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1.75, Grain size (Phi) 9.16 |
44 | Size fraction 2.010-1.832 µm | 2.010-1.832 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1.92, Grain size (Phi) 9.03 |
45 | Size fraction 2.208-2.011 µm | 2.208-2.011 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 2.11, Grain size (Phi) 8.89 |
46 | Size fraction 2.423-2.208 µm | 2.423-2.208 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 2.31, Grain size (Phi) 8.76 |
47 | Size fraction 2.66-2.423 µm | 2.66-2.423 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 2.54, Grain size (Phi) 8.62 |
48 | Size fraction 2.92-2.66 µm | 2.92-2.66 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 2.79, Grain size (Phi) 8.49 |
49 | Size fraction 3.206-2.920 µm | 3.206-2.920 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 3.06, Grain size (Phi) 8.35 |
50 | Size fraction 3.519-3.206 µm | 3.519-3.206 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 3.36, Grain size (Phi) 8.22 |
51 | Size fraction 3.862-3.519 µm | 3.862-3.519 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 3.69, Grain size (Phi) 8.08 |
52 | Size fraction 4.241-3.862 µm | 4.241-3.862 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 4.05, Grain size (Phi) 7.95 |
53 | Size fraction 4.656-4.241 µm | 4.656-4.241 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 4.44, Grain size (Phi) 7.81 |
54 | Size fraction 5.111-4.656 µm | 5.111-4.656 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 4.88, Grain size (Phi) 7.68 |
55 | Size fraction 5.611-5.111 µm | 5.611-5.111 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 5.35, Grain size (Phi) 7.54 |
56 | Size fraction 6.159-5.611 µm | 6.159-5.611 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 5.88, Grain size (Phi) 7.41 |
57 | Size fraction 6.761-6.159 µm | 6.761-6.159 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 6.45, Grain size (Phi) 7.28 |
58 | Size fraction 7.421-6.761 µm | 7.421-6.761 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 7.08, Grain size (Phi) 7.14 |
59 | Size fraction 8.148-7.422 µm | 8.148-7.422 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 7.78, Grain size (Phi) 7.01 |
60 | Size fraction 8.944-8.147 µm | 8.944-8.147 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 8.54, Grain size (Phi) 6.87 |
61 | Size fraction 9.819-8.944 µm | 9.819-8.944 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 9.37, Grain size (Phi) 6.74 |
62 | Size fraction 10.78-9.819 µm | 10.78-9.819 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 10.29, Grain size (Phi) 6.6 |
63 | Size fraction 11.83-10.78 µm | 11.83-10.78 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 11.29, Grain size (Phi) 6.47 |
64 | Size fraction 12.99-11.83 µm | 12.99-11.83 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 12.4, Grain size (Phi) 6.33 |
65 | Size fraction 14.26-12.99 µm | 14.26-12.99 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 13.61, Grain size (Phi) 6.2 |
66 | Size fraction 15.65-14.26 µm | 15.65-14.26 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 14.94, Grain size (Phi) 6.06 |
67 | Size fraction 17.18-15.65 µm | 17.18-15.65 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 16.4, Grain size (Phi) 5.93 |
68 | Size fraction 18.86-17.18 µm | 18.86-17.18 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 18, Grain size (Phi) 5.8 |
69 | Size fraction 20.70-18.86 µm | 20.70-18.86 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 19.76, Grain size (Phi) 5.66 |
70 | Size fraction 22.73-20.70 µm | 22.73-20.70 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 21.7, Grain size (Phi) 5.53 |
71 | Size fraction 24.95-22.73 µm | 24.95-22.73 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 23.81, Grain size (Phi) 5.39 |
72 | Size fraction 27.38-24.95 µm | 27.38-24.95 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 26.14, Grain size (Phi) 5.26 |
73 | Size fraction 30.07-27.38 µm | 30.07-27.38 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 28.7, Grain size (Phi) 5.12 |
74 | Size fraction 33.01-30.07 µm | 33.01-30.07 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 31.51, Grain size (Phi) 4.99 |
75 | Size fraction 36.24-33.01 µm | 36.24-33.01 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 34.59, Grain size (Phi) 4.85 |
76 | Size fraction 39.77-36.24 µm | 39.77-36.24 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 37.97, Grain size (Phi) 4.72 |
77 | Size fraction 43.67-39.78 µm | 43.67-39.78 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 41.68, Grain size (Phi) 4.58 |
78 | Size fraction 47.94-43.67 µm | 47.94-43.67 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 45.76, Grain size (Phi) 4.45 |
79 | Size fraction 52.63-47.94 µm | 52.63-47.94 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 50.23, Grain size (Phi) 4.32 |
80 | Size fraction 57.77-52.63 µm | 57.77-52.63 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 55.14, Grain size (Phi) 4.18 |
81 | Size fraction 63.42-57.77 µm | 63.42-57.77 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 60.53, Grain size (Phi) 4.05 |
82 | Size fraction 69.62-63.42 µm | 69.62-63.42 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 66.45, Grain size (Phi) 3.91 |
83 | Size fraction 76.43-69.62 µm | 76.43-69.62 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 72.95, Grain size (Phi) 3.78 |
84 | Size fraction 83.90-76.43 µm | 83.90-76.43 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 80.08, Grain size (Phi) 3.64 |
85 | Size fraction 92.1-83.9 µm | 92.1-83.9 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 87.9, Grain size (Phi) 3.51 |
86 | Size fraction 101.1-92.1 µm | 101.1-92.1 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 96.5, Grain size (Phi) 3.37 |
87 | Size fraction 111-101.1 µm | 111-101.1 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 105.93, Grain size (Phi) 3.24 |
88 | Size fraction 121.8-111 µm | 121.8-111 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 116.27, Grain size (Phi) 3.1 |
89 | Size fraction 133.7-121.8 µm | 133.7-121.8 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 127.66, Grain size (Phi) 2.97 |
90 | Size fraction 146.8-133.7 µm | 146.8-133.7 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 140.15, Grain size (Phi) 2.83 |
91 | Size fraction 161.2-146.8 µm | 161.2-146.8 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 153.83, Grain size (Phi) 2.7 |
92 | Size fraction 176.9-161.2 µm | 176.9-161.2 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 168.87, Grain size (Phi) 2.57 |
93 | Size fraction 194.2-176.9 µm | 194.2-176.9 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 185.35, Grain size (Phi) 2.43 |
94 | Size fraction 213.2-194.2 µm | 213.2-194.2 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 203.48, Grain size (Phi) 2.3 |
95 | Size fraction 234.1-213.2 µm | 234.1-213.2 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 223.41, Grain size (Phi) 2.16 |
96 | Size fraction 256.9-234.1 µm | 256.9-234.1 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 245.24, Grain size (Phi) 2.03 |
97 | Size fraction 282.1-256.9 µm | 282.1-256.9 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 269.21, Grain size (Phi) 1.89 |
98 | Size fraction 309.6-282.1 µm | 309.6-282.1 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 295.53, Grain size (Phi) 1.76 |
99 | Size fraction 339.9-309.6 µm | 339.9-309.6 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 324.4, Grain size (Phi) 1.62 |
100 | Size fraction 373.1-339.9 µm | 373.1-339.9 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 356.11, Grain size (Phi) 1.49 |
101 | Size fraction 409.6-373.1 µm | 409.6-373.1 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 390.92, Grain size (Phi) 1.36 |
102 | Size fraction 449.7-409.6 µm | 449.7-409.6 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 429.18, Grain size (Phi) 1.22 |
103 | Size fraction 493.6-449.7 µm | 493.6-449.7 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 471.14, Grain size (Phi) 1.09 |
104 | Size fraction 541.9-493.6 µm | 541.9-493.6 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 517.19, Grain size (Phi) 0.95 |
105 | Size fraction 594.9-541.9 µm | 594.9-541.9 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 567.78, Grain size (Phi) 0.82 |
106 | Size fraction 653.0-594.9 µm | 653.0-594.9 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 623.27, Grain size (Phi) 0.68 |
107 | Size fraction 716.9-653.0 µm | 716.9-653.0 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 684.2, Grain size (Phi) 0.55 |
108 | Size fraction 786.9-716.9 µm | 786.9-716.9 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 751.13, Grain size (Phi) 0.41 |
109 | Size fraction 863.9-786.9 µm | 863.9-786.9 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 824.55, Grain size (Phi) 0.28 |
110 | Size fraction 948.2-863.9 µm | 948.2-863.9 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 905.12, Grain size (Phi) 0.14 |
111 | Size fraction 1041-948.3 µm | 1041-948.3 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 993.57, Grain size (Phi) 0.01 |
112 | Size fraction 1143-1041 µm | 1143-1041 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1090.81, Grain size (Phi) -0.13 |
113 | Size fraction 1255-1143 µm | 1255-1143 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1197.69, Grain size (Phi) -0.26 |
114 | Size fraction 1377-1255 µm | 1377-1255 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1314.59, Grain size (Phi) -0.39 |
115 | Size fraction 1512-1377 µm | 1512-1377 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1442.92, Grain size (Phi) -0.53 |
116 | Size fraction 1660-1512 µm | 1660-1512 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1584.27, Grain size (Phi) -0.66 |
117 | Size fraction 1822-1660 µm | 1822-1660 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1739.11, Grain size (Phi) -0.8 |
118 | Size fraction 2.000-1.822 mm | 2000-1822 µm | % | van Kaam, Rianne | Beckman Coulter Laser diffraction particle size analyzer LS 13 320 | Grain size (µm) 1908.93, Grain size (Phi) -0.93 |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
348 data points