Pieck, Daniela; Thölen, Claudia; Voß, Daniela; Zielinski, Oliver; Becker, Marius (2024): Continuous optical measurements of absorbance via UV-process spectrophotometer ProPS along RV MARIA S. MERIAN cruise MSM97/2 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.967383, In: Pieck, D et al. (2024): Continuous optical measurements of absorbance for the calculation of optical Nitrate along RV MARIA S. MERIAN cruise MSM97/2 [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.967381

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
During R/V Maria S. Merian cruise MSM97/2 a sensor box (AddOn Box) was attached to a PocketFerryBox (4H Jena, Germany) in-line obtaining waters from the ships two autonomous measurement systems (RSWS). For the measurement of underway absorption spectra to calculate optical nitrate, the AddOn Box was equipped with two UV-process spectrophotometer (ProPS and OPUS, TriOS Mess- und Datentechnik GmbH, Germany). Data were recorded continuously in a ten-minute interval along the cruise track with an optical path length of 10 mm. The integration time was 256 ms. The ProPS photometer is equipped with a Deuterium lamp as light source whereas the OPUS photometer is equipped with a Xenon flash lamp. Baseline calibrations were done for both UV-photometer using ultrapure water. For the ProPS, the calibration was done in the laboratory before the cruise whereas the calibration for the OPUS was done by the manufacturer. The water inlet of the RSWS is allocated at approx. 6.5 m below the sea surface. While one box is measuring, the other box is being cleaned. The boxes switch after a user-defined measuring and cleaning interval. On MSM97/2, the boxes were alternating every 12 hours, including one short cleaning procedure during measurements after 4 hours. Absorption spectra obtained by the AddOn Box during the alternation process of the two RSWS, as well as during the internal cleaning procedure are not included. Spectra from station work are included. Within this dataset, absorption spectra were cut to a relevant wavelength range (from 189-360 nm (ProPS) and 199-360 nm (OPUS) to 210-260 nm). No further correction was done for the absorbance spectra in this processing step.
Keyword(s):
Absorbance; Bio-optics; DAM; Deutsche Allianz für Meeresforschung; ICBM; MSM97/2; optical nitrate; UV-photometer
Related to:
Pieck, Daniela; Thölen, Claudia; Lehners, Carola; Voß, Daniela; Zielinski, Oliver: Reference measurements of surface waters during the RV MARIA S. MERIAN cruise MSM97/2. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.967466
References:
Frank, Carsten; Meier, Daniela; Voß, Daniela; Zielinski, Oliver (2014): Computation of nitrate concentrations in coastal waters using an in situ ultraviolet spectrophotometer: Behavior of different computation methods in a case study a steep salinity gradient in the southern North Sea. Methods in Oceanography, 9, 34-43, https://doi.org/10.1016/j.mio.2014.09.002
Zielinski, Oliver; Voß, Daniela; Saworski, B; Fiedler, Björn; Körtzinger, Arne (2011): Computation of nitrate concentrations in turbid coastal waters using an in situ ultraviolet spectrophotometer. Journal of Sea Research, 65(4), 456-460, https://doi.org/10.1016/j.seares.2011.04.002
Related code / software:
Meier, Daniela; Voß, Daniela; Zielinski, Oliver (2020): Matlab code for the computation of nitrate based on optical absorption measurements with UV-hyperspectral photometer (OPUS/TriOS). Zenodo, https://doi.org/10.5281/ZENODO.4091421
Coverage:
Median Latitude: 60.444216 * Median Longitude: 2.517145 * South-bound Latitude: 53.629557 * West-bound Longitude: -1.941989 * North-bound Latitude: 67.258604 * East-bound Longitude: 7.779832
Date/Time Start: 2020-12-13T10:10:00 * Date/Time End: 2020-12-22T18:30:00
Minimum DEPTH, water: 6.5 m * Maximum DEPTH, water: 6.5 m
Event(s):
MSM97/2_0_Underway-16 * Latitude Start: 54.656924 * Longitude Start: 7.733995 * Latitude End: 54.435320 * Longitude End: 7.189963 * Date/Time Start: 2020-12-13T10:10:00 * Date/Time End: 2020-12-22T18:30:00 * Campaign: MSM97/2 (GPF 20‐2_062) * Basis: Maria S. Merian * Method/Device: UV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105] * Comment: event was not logged in DSHIP
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DATE/TIMEDate/TimePieck, DanielaGeocode
2DEPTH, waterDepth watermPieck, DanielaGeocode
3LATITUDELatitudePieck, DanielaGeocode
4LONGITUDELongitudePieck, DanielaGeocode
5Measurement containerMCPieck, Daniela
6Data IDData IDPieck, Daniela
7Absorbance, 210.35 nmAbsorbance 210.35AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
8Absorbance, 211.15 nmAbsorbance 211.15AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
9Absorbance, 211.95 nmAbsorbance 211.95AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
10Absorbance, 212.75 nmAbsorbance 212.75AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
11Absorbance, 213.55 nmAbsorbance 213.55AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
12Absorbance, 214.35 nmAbsorbance 214.35AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
13Absorbance, 215.15 nmAbsorbance 215.15AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
14Absorbance, 215.95 nmAbsorbance 215.95AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
15Absorbance, 216.75 nmAbsorbance 216.75AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
16Absorbance, 217.55 nmAbsorbance 217.55AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
17Absorbance, 218.35 nmAbsorbance 218.35AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
18Absorbance, 219.16 nmAbsorbance 219.16AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
19Absorbance, 219.96 nmAbsorbance 219.96AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
20Absorbance, 220.76 nmAbsorbance 220.76AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
21Absorbance, 221.56 nmAbsorbance 221.56AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
22Absorbance, 222.37 nmAbsorbance 222.37AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
23Absorbance, 223.17 nmAbsorbance 223.17AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
24Absorbance, 223.97 nmAbsorbance 223.97AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
25Absorbance, 224.78 nmAbsorbance 224.78AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
26Absorbance, 225.58 nmAbsorbance 225.58AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
27Absorbance, 226.38 nmAbsorbance 226.38AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
28Absorbance, 227.19 nmAbsorbance 227.19AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
29Absorbance, 227.99 nmAbsorbance 227.99AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
30Absorbance, 228.8 nmAbsorbance 228.8AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
31Absorbance, 229.6 nmAbsorbance 229.6AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
32Absorbance, 230.41 nmAbsorbance 230.41AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
33Absorbance, 231.21 nmAbsorbance 231.21AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
34Absorbance, 232.02 nmAbsorbance 232.02AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
35Absorbance, 232.82 nmAbsorbance 232.82AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
36Absorbance, 233.63 nmAbsorbance 233.63AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
37Absorbance, 234.44 nmAbsorbance 234.44AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
38Absorbance, 235.24 nmAbsorbance 235.24AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
39Absorbance, 236.05 nmAbsorbance 236.05AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
40Absorbance, 236.86 nmAbsorbance 236.86AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
41Absorbance, 237.66 nmAbsorbance 237.66AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
42Absorbance, 238.47 nmAbsorbance 238.47AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
43Absorbance, 239.28 nmAbsorbance 239.28AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
44Absorbance, 240.09 nmAbsorbance 240.09AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
45Absorbance, 240.89 nmAbsorbance 240.89AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
46Absorbance, 241.7 nmAbsorbance 241.7AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
47Absorbance, 242.51 nmAbsorbance 242.51AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
48Absorbance, 243.32 nmAbsorbance 243.32AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
49Absorbance, 244.13 nmAbsorbance 244.13AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
50Absorbance, 244.93 nmAbsorbance 244.93AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
51Absorbance, 245.74 nmAbsorbance 245.74AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
52Absorbance, 246.55 nmAbsorbance 246.55AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
53Absorbance, 247.36 nmAbsorbance 247.36AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
54Absorbance, 248.17 nmAbsorbance 248.17AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
55Absorbance, 248.98 nmAbsorbance 248.98AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
56Absorbance, 249.79 nmAbsorbance 249.79AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
57Absorbance, 250.6 nmAbsorbance 250.6AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
58Absorbance, 251.41 nmAbsorbance 251.41AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
59Absorbance, 252.22 nmAbsorbance 252.22AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
60Absorbance, 253.03 nmAbsorbance 253.03AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
61Absorbance, 253.84 nmAbsorbance 253.84AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
62Absorbance, 254.65 nmAbsorbance 254.65AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
63Absorbance, 255.46 nmAbsorbance 255.46AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
64Absorbance, 256.27 nmAbsorbance 256.27AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
65Absorbance, 257.09 nmAbsorbance 257.09AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
66Absorbance, 257.9 nmAbsorbance 257.9AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
67Absorbance, 258.71 nmAbsorbance 258.71AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
68Absorbance, 259.52 nmAbsorbance 259.52AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
69Absorbance, 260.33 nmAbsorbance 260.33AUPieck, DanielaUV process spectrophotometer, TriOS Mess- und Datentechnik GmbH, ProPS [SN: D105]
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
46800 data points