Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Siems, Anna; Nantke, Carla; Neumann, Andreas; Sanders, Tina; Pröfrock, Daniel: Nutrient and trace metal data distribution from water samples of HEINCKE cruise HE586 [dataset]. PANGAEA, https://doi.pangaea.de/10.1594/PANGAEA.967369 (dataset in review)

Show MapGoogle Earth

Abstract:
The water samples were taken from Niskin bottles attached to a CTD in October 2021 on the cruise HE586 in the Skagerrak and the North Sea. The trace element samples were filtered in triplicates with DigiFILTERs (trademark) (0.45 microm, 50 mL, SCP Science, Canada) and measured by seaFAST-ICP-MS (seaFAST SP2, Elemental Scientific, USA; Agilent 8900, Agilent Technologies, Japan; Przibilla et al., 2023; https://doi.org/10.1002/wer.10922). The nutrient samples were filtered with 0.47microm cellulose acetate syringe filters (Minisart, Sartorius, Germany) and analyzed with standard colorimetric techniques (Hansen and Koroleff, 2007) on a continuous flow auto analyzer (AA3, SEAL Analytical, Germany).
Coverage:
Median Latitude: 56.986038 * Median Longitude: 8.585351 * South-bound Latitude: 53.526076 * West-bound Longitude: 6.287700 * North-bound Latitude: 58.330495 * East-bound Longitude: 9.775516
Date/Time Start: 2021-10-04T14:44:53 * Date/Time End: 2021-10-10T14:06:06
Minimum DEPTH, water: 2.195 m * Maximum DEPTH, water: 683.313 m
Event(s):
HE586_1-5 * Latitude: 53.526076 * Longitude: 8.566815 * Date/Time: 2021-10-04T14:44:36 * Elevation: -13.2 m * Location: North Sea * Campaign: HE586 (ICBM-HS-EMD-LER_22) * Basis: Heincke * Method/Device: CTD/Rosette (CTD-RO)
HE586_2-2 * Latitude: 54.470350 * Longitude: 7.562690 * Date/Time: 2021-10-05T06:07:17 * Elevation: -19.7 m * Location: North Sea * Campaign: HE586 (ICBM-HS-EMD-LER_22) * Basis: Heincke * Method/Device: CTD/Rosette (CTD-RO)
HE586_3-1 * Latitude: 54.497765 * Longitude: 7.615143 * Date/Time: 2021-10-05T12:38:51 * Elevation: -20.9 m * Location: North Sea * Campaign: HE586 (ICBM-HS-EMD-LER_22) * Basis: Heincke * Method/Device: CTD/Rosette (CTD-RO)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventSiems, Anna
2Station labelStationSiems, Anna
3Sample code/labelSample labelSiems, Anna
4DATE/TIMEDate/TimeSiems, AnnaGeocode
5LATITUDELatitudeSiems, AnnaGeocode
6LONGITUDELongitudeSiems, AnnaGeocode
7DEPTH, waterDepth watermSiems, AnnaGeocode
8Device typeDeviceSiems, Anna
9Sample elevationElevationmSiems, Anna
10VanadiumVng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 1.48 Nanogram per liter, limit of quantification: 1.8 Nanogram per liter
11Vanadium, uncertaintyV unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
12ManganeseMnng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 41 Nanogram per liter, limit of quantification: 111 Nanogram per liter
13Manganese, uncertaintyMn unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
14IronFeng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 41 Nanogram per liter, limit of quantification: 111 Nanogram per liter
15Iron, uncertaintyFe unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
16CobaltCong/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.18 Nanogram per liter, limit of quantification: 0.44 Nanogram per liter
17Cobalt, uncertaintyCo unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
18NickelNing/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 11.6 Nanogram per liter, limit of quantification: 32.2 Nanogram per liter
19Nickel, uncertaintyNi unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
20CopperCung/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 10.9 Nanogram per liter, limit of quantification: 28.2 Nanogram per liter
21Copper, uncertaintyCu unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
22ZincZnng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 970 Nanogram per liter, limit of quantification: 2670 Nanogram per liter
23Zinc, uncertaintyZn unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
24MolybdenumMong/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 2.3 Nanogram per liter, limit of quantification: 5.7 Nanogram per liter
25Molybdenum, uncertaintyMo unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
26CadmiumCdng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.33 Nanogram per liter, limit of quantification: 0.92 Nanogram per liter
27Cadmium, uncertaintyCd unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
28TungstenWng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.4 Nanogram per liter, limit of quantification: 0.73 Nanogram per liter
29Tungsten, uncertaintyW unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
30LeadPbng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 3.5 Nanogram per liter, limit of quantification: 9.3 Nanogram per liter
31Lead, uncertaintyPb unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
32UraniumUng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.39 Nanogram per liter, limit of quantification: 1.05 Nanogram per liter
33Uranium, uncertaintyU unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
34YttriumYng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.29 Nanogram per liter, limit of quantification: 0.79 Nanogram per liter
35Yttrium, uncertaintyY unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
36LanthanumLang/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.23 Nanogram per liter, limit of quantification: 0.61 Nanogram per liter
37Lanthanum, uncertaintyLa unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
38CeriumCeng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.28 Nanogram per liter, limit of quantification: 0.77 Nanogram per liter
39Cerium, uncertaintyCe unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
40PraseodymiumPrng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.053 Nanogram per liter, limit of quantification: 0.145 Nanogram per liter
41Praseodymium, uncertaintyPr unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
42NeodymiumNdng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.2 Nanogram per liter, limit of quantification: 0.54 Nanogram per liter
43Neodymium, uncertaintyNd unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
44SamariumSmng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.035 Nanogram per liter, limit of quantification: 0.095 Nanogram per liter
45Samarium, uncertaintySm unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
46EuropiumEung/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.0097 Nanogram per liter, limit of quantification: 0.027 Nanogram per liter
47Europium, uncertaintyEu unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
48GadoliniumGdng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.104 Nanogram per liter, limit of quantification: 0.292 Nanogram per liter
49Gadolinium, uncertaintyGd unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
50TerbiumTbng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.0089 Nanogram per liter, limit of quantification: 0.011 Nanogram per liter
51Terbium, uncertaintyTb unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
52DysprosiumDyng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.028 Nanogram per liter, limit of quantification: 0.081 Nanogram per liter
53Dysprosium, uncertaintyDy unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
54HolmiumHong/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.0097 Nanogram per liter, limit of quantification: 0.018 Nanogram per liter
55Holmium, uncertaintyHo unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
56ErbiumErng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.015 Nanogram per liter, limit of quantification: 0.044 Nanogram per liter
57Erbium, uncertaintyEr unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
58ThuliumTmng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.023 Nanogram per liter
59Thulium, uncertaintyTm unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
60YtterbiumYbng/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.04 Nanogram per liter
61Ytterbium, uncertaintyYb unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
62LutetiumLung/lSiems, AnnaICP-MS, Elemental Scientific, seaFASTmeasured in water column, < 0.45 microm filtrate, limit of detection: 0.07 Nanogram per liter
63Lutetium, uncertaintyLu unc±Siems, AnnaICP-MS, Elemental Scientific, seaFAST
64Nitrate[NO3]-µmol/lSiems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analysermeasured in water column, limit of detection for HE586: 0.518 Micromol per liter, limit of quantification for HE586: 1.853 Micromol per liter
65Nitrate, uncertainty[NO3]- unc±Siems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analyser
66Nitrite[NO2]-µmol/lSiems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analysermeasured in water column, limit of detection for HE586: 0.031 Micromol per liter, limit of quantification for HE586: 0.113 Micromol per liter
67Nitrite, uncertainty[NO2]- unc±Siems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analyser
68Ammonium[NH4]+µmol/lSiems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analysermeasured in water column, limit of detection for HE586: 0.111 Micromol per liter, limit of quantification for HE586: 0.4 Micromol per liter
69Ammonium, uncertainty[NH4]+ unc±Siems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analyser
70SilicateSi(OH)4µmol/lSiems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analysermeasured in water column, limit of detection for HE586: 0.422 Micromol per liter, limit of quantification for HE586: 1.528 Micromol per liter,
71Silicate, dissolved, uncertaintyDSi(OH)4 unc±Siems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analyser
72Phosphate[PO4]3-µmol/lSiems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analysermeasured in water column, limit of detection for HE586: 0.017 Micromol per liter, limit of quantification for HE586: 0.062 Micromol per liter
73Phosphate, uncertainty[PO4]3- unc±Siems, AnnaAA3 Seal Analytical continuous segmented flow nutrient analyser
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0) (License comes into effect after moratorium ends)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
4845 data points

Download Data (login required; moratorium until 2026-02-19)

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)