Marandino, Christa A; Schumacher, Mia (2024): Multibeam bathymetry raw data (Kongsberg EM 122 entire dataset) of RV MARIA S. MERIAN during cruise MSM123 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.965756
Always quote citation above when using data! You can download the citation in several formats below.
Abstract:
Raw multibeam bathymetry data were collected aboard RV MARIA S. MERIAN during cruise MSM123 using a Kongsberg EM 122 multibeam echosounder. The expedition took place during 2023-11-23 - 2023-12-27 from Halifax (Canada) to St. John's (Canada) in the Labrador Sea. Data were recorded in the EEZs of Brasil and Cape Verde and outside. The aim of MSM123 is to understand and quantify bubble-mediated gas exchange mechanisms in the Labrador Sea (BELS). Sound velocity profiles (SVP) were applied on the data for calibration. Please see environmental data and the cruise report for details. The data are unprocessed and can therefore contain incorrect depth measurements (artifacts) if not further processed. Note that refraction errors may occur when no proper SVP is applied. Acquisition and provision of the data are part of the DAM Underway Project and are according to the FAIR principles.
Project(s):
DAM Underway Research Data (DAM_Underway)
Coverage:
Median Latitude: 54.268617 * Median Longitude: -51.830645 * South-bound Latitude: -50.880770 * West-bound Longitude: -56.126020 * North-bound Latitude: 57.512105 * East-bound Longitude: 53.118710
Date/Time Start: 2023-11-25T23:30:24 * Date/Time End: 2023-12-27T10:02:42
Minimum ELEVATION: -3965.6990 m a.s.l. * Maximum ELEVATION: -53.0341 m a.s.l.
Event(s):
MSM123_0_Underway-5 * Latitude Start: 45.683500 * Longitude Start: -56.126000 * Latitude End: 47.656500 * Longitude End: -52.511000 * Date/Time Start: 2023-11-25T23:30:24 * Date/Time End: 2023-12-27T10:30:34 * Elevation: -55.0 m * Campaign: MSM123 (BELS) * Basis: Maria S. Merian * Method/Device: EM122 multibeam echosounder (EM122) * Comment: Event shows start/end point (date/time & coordinates) of first/last data record using Kongsberg EM 122 multibeam echosounder during cruise MSM123
MSM123_3-1 * Latitude: 53.118710 * Longitude: -50.880770 * Date/Time: 2023-11-28T20:12:13 * Elevation: -2917.0 m * Campaign: MSM123 (BELS) * Basis: Maria S. Merian * Method/Device: CTD/Rosette (CTD-RO)
Comment:
These data should not be used for navigational purposes.
Parameter(s):
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC) * Processing Level: PANGAEA data processing level 1 (ProcLevel1)
Size:
12226 data points
Data
All files referred to in data matrix can be downloaded in one go as ZIP or TAR. Be careful: This download can be very large! To protect our systems from misuse, we require to sign up for an user account before downloading.
1 Event | 2 Binary | 3 Binary (Type) | 4 Binary (Size) [Bytes] | 5 Datagram rfn | 6 Content | 7 Data record duration [min] | 8 Data record distance [m] | 9 Ship sp [kn] | 10 Pings | 11 File start date/time | 12 File start latitude | 13 File start longitude | 14 File start heading [deg] | 15 File start depth [m] | 16 File stop date/time | 17 File stop latitude | 18 File stop longitude | 19 File stop heading [deg] | 20 File stop depth [m] | 21 Date/Time | 22 Latitude | 23 Longitude | 24 Elevation [m a.s.l.] | 25 Comment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MSM123_0_Underway-5 | msm123_mbes_raw_em122_ed_sis_svp.zip | application/zip | 1.1 MBytes | Complete record (zip file) of environmental data files stored in Kongsberg Seafloor Information System (SIS) raw data folder (.asvp, .abs, .temp files). All files stored in this zip file could not put into relation (events) during data curation. | ||||||||||||||||||||
MSM123_3-1 | MSM123_ctd_003.cnv | text/plain | 100.4 kBytes | 2023-11-28T20:12:00 | -50.88077000 | 53.1187100 | -2917.0000 | GEOCODES from event | ||||||||||||||||
MSM123_0_Underway-5 | 0000_20231125_233025_MerianEM122.all | application/octet-stream | 160.3 MBytes | 0000_20231125_233025_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 30.000 | 11200.6 | 12.1096 | 7302 | 2023-11-25T23:30:24 | 45.68354790 | -56.1260197 | 71.58 | 53.0341 | 2023-11-26T00:00:24 | 45.70887785 | -55.9869614 | 74.28 | 53.0934 | 2023-11-25T23:30:24 | 45.68354790 | -56.1260197 | -53.0341 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0001_20231126_000025_MerianEM122.all | application/octet-stream | 157.6 MBytes | 0001_20231126_000025_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11135.1 | 12.0404 | 7166 | 2023-11-26T00:00:25 | 45.70888255 | -55.9869229 | 73.85 | 56.8648 | 2023-11-26T00:30:24 | 45.73405130 | -55.8486020 | 72.14 | 56.2247 | 2023-11-26T00:00:25 | 45.70888255 | -55.9869229 | -56.8648 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0002_20231126_003025_MerianEM122.all | application/octet-stream | 165.7 MBytes | 0002_20231126_003025_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11320.8 | 12.2422 | 7562 | 2023-11-26T00:30:25 | 45.73406230 | -55.8485231 | 71.78 | 55.7152 | 2023-11-26T01:00:24 | 45.75950270 | -55.7078359 | 71.97 | 61.5373 | 2023-11-26T00:30:25 | 45.73406230 | -55.8485231 | -55.7152 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0003_20231126_010025_MerianEM122.all | application/octet-stream | 44.5 MBytes | 0003_20231126_010025_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 6.126 | 2342.3 | 12.4015 | 1546 | 2023-11-26T01:00:25 | 45.75951745 | -55.7077490 | 72.58 | 62.0413 | 2023-11-26T01:06:32 | 45.76471845 | -55.6785860 | 72.80 | 63.1421 | 2023-11-26T01:00:25 | 45.75951745 | -55.7077490 | -62.0413 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0004_20231126_013029_MerianEM122.all | application/octet-stream | 1.6 MBytes | 0004_20231126_013029_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 0.018 | 0.0 | 0.0000 | 2 | 2023-11-26T01:30:28 | 45.78505875 | -55.5659201 | 70.40 | 66.9198 | 2023-11-26T01:30:29 | 45.78505875 | -55.5659201 | 70.40 | 66.6339 | 2023-11-26T01:30:28 | 45.78505875 | -55.5659201 | -66.9198 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0005_20231126_014814_MerianEM122.all | application/octet-stream | 152.8 MBytes | 0005_20231126_014814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11128.6 | 12.0362 | 6692 | 2023-11-26T01:48:13 | 45.80000735 | -55.4840116 | 70.51 | 75.1531 | 2023-11-26T02:18:13 | 45.82515250 | -55.3454910 | 73.26 | 167.9882 | 2023-11-26T01:48:13 | 45.80000735 | -55.4840116 | -75.1531 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0006_20231126_021814_MerianEM122.all | application/octet-stream | 121.1 MBytes | 0006_20231126_021814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11235.6 | 12.1499 | 4904 | 2023-11-26T02:18:13 | 45.82517560 | -55.3453635 | 73.41 | 161.9799 | 2023-11-26T02:48:13 | 45.85037730 | -55.2053863 | 73.26 | 166.2476 | 2023-11-26T02:18:13 | 45.82517560 | -55.3453635 | -161.9799 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0007_20231126_024814_MerianEM122.all | application/octet-stream | 122.3 MBytes | 0007_20231126_024814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11232.1 | 12.1473 | 4969 | 2023-11-26T02:48:14 | 45.85040075 | -55.2052778 | 72.70 | 166.8355 | 2023-11-26T03:18:13 | 45.87568820 | -55.0653017 | 72.68 | 143.0254 | 2023-11-26T02:48:14 | 45.85040075 | -55.2052778 | -166.8355 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0008_20231126_031814_MerianEM122.all | application/octet-stream | 154.1 MBytes | 0008_20231126_031814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11362.8 | 12.2881 | 6724 | 2023-11-26T03:18:13 | 45.87570975 | -55.0651934 | 73.17 | 142.6599 | 2023-11-26T03:48:13 | 45.90138430 | -54.9235604 | 73.46 | 74.0596 | 2023-11-26T03:18:13 | 45.87570975 | -55.0651934 | -142.6599 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0009_20231126_034814_MerianEM122.all | application/octet-stream | 166.5 MBytes | 0009_20231126_034814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11435.4 | 12.3661 | 7562 | 2023-11-26T03:48:13 | 45.90139660 | -54.9234921 | 73.54 | 75.5778 | 2023-11-26T04:18:13 | 45.92719930 | -54.7808590 | 75.46 | 62.4659 | 2023-11-26T03:48:13 | 45.90139660 | -54.9234921 | -75.5778 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0010_20231126_041814_MerianEM122.all | application/octet-stream | 168.1 MBytes | 0010_20231126_041814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11449.9 | 12.3818 | 7560 | 2023-11-26T04:18:13 | 45.92721255 | -54.7807853 | 75.78 | 62.4940 | 2023-11-26T04:48:13 | 45.95302095 | -54.6378969 | 74.74 | 89.6794 | 2023-11-26T04:18:13 | 45.92721255 | -54.7807853 | -62.4940 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0011_20231126_044814_MerianEM122.all | application/octet-stream | 168.9 MBytes | 0011_20231126_044814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11447.2 | 12.3772 | 7525 | 2023-11-26T04:48:13 | 45.95303550 | -54.6378209 | 74.52 | 87.8631 | 2023-11-26T05:18:13 | 45.97879680 | -54.4948850 | 75.26 | 107.3841 | 2023-11-26T04:48:13 | 45.95303550 | -54.6378209 | -87.8631 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0012_20231126_051814_MerianEM122.all | application/octet-stream | 159 MBytes | 0012_20231126_051814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11375.9 | 12.3023 | 6951 | 2023-11-26T05:18:13 | 45.97881425 | -54.4947839 | 75.37 | 107.5032 | 2023-11-26T05:48:13 | 46.00448490 | -54.3526836 | 74.94 | 114.2135 | 2023-11-26T05:18:13 | 45.97881425 | -54.4947839 | -107.5032 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0013_20231126_054814_MerianEM122.all | application/octet-stream | 148.7 MBytes | 0013_20231126_054814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11266.4 | 12.1813 | 6394 | 2023-11-26T05:48:13 | 46.00449940 | -54.3526113 | 75.09 | 113.8134 | 2023-11-26T06:18:13 | 46.02992890 | -54.2118210 | 74.43 | 130.9373 | 2023-11-26T05:48:13 | 46.00449940 | -54.3526113 | -113.8134 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0014_20231126_061814_MerianEM122.all | application/octet-stream | 131.4 MBytes | 0014_20231126_061814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11365.6 | 12.2961 | 5468 | 2023-11-26T06:18:14 | 46.02994620 | -54.2117307 | 74.48 | 133.9989 | 2023-11-26T06:48:12 | 46.05544590 | -54.0695739 | 75.73 | 155.3003 | 2023-11-26T06:18:14 | 46.02994620 | -54.2117307 | -133.9989 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0015_20231126_064814_MerianEM122.all | application/octet-stream | 126.3 MBytes | 0015_20231126_064814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 30.000 | 10983.4 | 11.8738 | 5181 | 2023-11-26T06:48:13 | 46.05546400 | -54.0694677 | 76.36 | 155.3665 | 2023-11-26T07:18:13 | 46.08028710 | -53.9321119 | 75.26 | 151.8502 | 2023-11-26T06:48:13 | 46.05546400 | -54.0694677 | -155.3665 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0016_20231126_071814_MerianEM122.all | application/octet-stream | 125.7 MBytes | 0016_20231126_071814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 10952.7 | 11.8473 | 5146 | 2023-11-26T07:18:14 | 46.08030300 | -53.9320207 | 75.15 | 151.7864 | 2023-11-26T07:48:13 | 46.10494885 | -53.7949425 | 73.66 | 155.0776 | 2023-11-26T07:18:14 | 46.08030300 | -53.9320207 | -151.7864 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0017_20231126_074814_MerianEM122.all | application/octet-stream | 120.6 MBytes | 0017_20231126_074814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11100.9 | 12.0041 | 4877 | 2023-11-26T07:48:13 | 46.10497185 | -53.7948250 | 74.14 | 155.2262 | 2023-11-26T08:18:13 | 46.13005800 | -53.6558665 | 74.77 | 173.1658 | 2023-11-26T07:48:13 | 46.10497185 | -53.7948250 | -155.2262 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0018_20231126_081814_MerianEM122.all | application/octet-stream | 122.7 MBytes | 0018_20231126_081814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11066.9 | 11.9698 | 4993 | 2023-11-26T08:18:14 | 46.13008070 | -53.6557325 | 74.62 | 173.3683 | 2023-11-26T08:48:13 | 46.15506375 | -53.5171215 | 74.44 | 157.8001 | 2023-11-26T08:18:14 | 46.13008070 | -53.6557325 | -173.3683 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0019_20231126_084814_MerianEM122.all | application/octet-stream | 124.2 MBytes | 0019_20231126_084814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 10955.9 | 11.8503 | 5069 | 2023-11-26T08:48:14 | 46.15508165 | -53.5170135 | 74.92 | 158.1506 | 2023-11-26T09:18:13 | 46.17979020 | -53.3797262 | 74.72 | 158.2417 | 2023-11-26T08:48:14 | 46.15508165 | -53.5170135 | -158.1506 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0020_20231126_091814_MerianEM122.all | application/octet-stream | 123.5 MBytes | 0020_20231126_091814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 10952.1 | 11.8432 | 5026 | 2023-11-26T09:18:13 | 46.17981260 | -53.3795993 | 75.04 | 158.3090 | 2023-11-26T09:48:13 | 46.20445580 | -53.2422759 | 73.89 | 158.6387 | 2023-11-26T09:18:13 | 46.17981260 | -53.3795993 | -158.3090 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0021_20231126_094814_MerianEM122.all | application/octet-stream | 123.2 MBytes | 0021_20231126_094814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 10858.6 | 11.7425 | 5006 | 2023-11-26T09:48:13 | 46.20447625 | -53.2421674 | 73.22 | 158.6334 | 2023-11-26T10:18:13 | 46.22894890 | -53.1059623 | 73.10 | 158.7132 | 2023-11-26T09:48:13 | 46.20447625 | -53.2421674 | -158.6334 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0022_20231126_101814_MerianEM122.all | application/octet-stream | 121.5 MBytes | 0022_20231126_101814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11122.7 | 12.0292 | 4914 | 2023-11-26T10:18:14 | 46.22896625 | -53.1058647 | 73.18 | 159.0127 | 2023-11-26T10:48:13 | 46.25401510 | -52.9662757 | 72.69 | 164.4733 | 2023-11-26T10:18:14 | 46.22896625 | -53.1058647 | -159.0127 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0023_20231126_104814_MerianEM122.all | application/octet-stream | 120.3 MBytes | 0023_20231126_104814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11466.6 | 12.4042 | 4865 | 2023-11-26T10:48:14 | 46.25403180 | -52.9661732 | 72.30 | 164.6571 | 2023-11-26T11:18:13 | 46.27983185 | -52.8222102 | 74.45 | 167.6717 | 2023-11-26T10:48:14 | 46.25403180 | -52.9661732 | -164.6571 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0024_20231126_111814_MerianEM122.all | application/octet-stream | 120 MBytes | 0024_20231126_111814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11691.1 | 12.6414 | 4857 | 2023-11-26T11:18:13 | 46.27986075 | -52.8220612 | 74.39 | 167.7028 | 2023-11-26T11:48:13 | 46.30623570 | -52.6752191 | 71.82 | 160.0522 | 2023-11-26T11:18:13 | 46.27986075 | -52.8220612 | -167.7028 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0025_20231126_114814_MerianEM122.all | application/octet-stream | 122.1 MBytes | 0025_20231126_114814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11686.4 | 12.6392 | 4973 | 2023-11-26T11:48:14 | 46.30625500 | -52.6751138 | 71.88 | 161.2858 | 2023-11-26T12:18:13 | 46.33259435 | -52.5282638 | 73.01 | 158.1395 | 2023-11-26T11:48:14 | 46.30625500 | -52.6751138 | -161.2858 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0026_20231126_121814_MerianEM122.all | application/octet-stream | 139.3 MBytes | 0026_20231126_121814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 10894.2 | 11.7805 | 5892 | 2023-11-26T12:18:14 | 46.33261400 | -52.5281489 | 72.76 | 156.7983 | 2023-11-26T12:48:13 | 46.35717970 | -52.3912086 | 76.48 | 109.1644 | 2023-11-26T12:18:14 | 46.33261400 | -52.5281489 | -156.7983 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0027_20231126_124814_MerianEM122.all | application/octet-stream | 154.4 MBytes | 0027_20231126_124814_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 27.516 | 5880.9 | 6.9314 | 6920 | 2023-11-26T12:48:14 | 46.35719415 | -52.3911161 | 76.19 | 108.6013 | 2023-11-26T13:15:45 | 46.36871550 | -52.3222429 | 248.89 | 84.3355 | 2023-11-26T12:48:14 | 46.35719415 | -52.3911161 | -108.6013 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0028_20231126_194826_MerianEM122.all | application/octet-stream | 169.1 MBytes | 0028_20231126_194826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 30.000 | 11795.1 | 12.7517 | 7564 | 2023-11-26T19:48:25 | 46.39087350 | -52.3142232 | 4.27 | 85.7623 | 2023-11-26T20:18:25 | 46.49607950 | -52.2949105 | 7.01 | 94.4848 | 2023-11-26T19:48:25 | 46.39087350 | -52.3142232 | -85.7623 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0029_20231126_201826_MerianEM122.all | application/octet-stream | 160.3 MBytes | 0029_20231126_201826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11907.1 | 12.8790 | 7033 | 2023-11-26T20:18:26 | 46.49612800 | -52.2948988 | 7.08 | 94.7539 | 2023-11-26T20:48:25 | 46.60220970 | -52.2736884 | 7.47 | 116.4418 | 2023-11-26T20:18:26 | 46.49612800 | -52.2948988 | -94.7539 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0030_20231126_204826_MerianEM122.all | application/octet-stream | 151.7 MBytes | 0030_20231126_204826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11954.8 | 12.9264 | 6557 | 2023-11-26T20:48:25 | 46.60228685 | -52.2736704 | 7.28 | 116.4642 | 2023-11-26T21:18:25 | 46.70880480 | -52.2524562 | 7.08 | 114.8327 | 2023-11-26T20:48:25 | 46.60228685 | -52.2736704 | -116.4642 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0031_20231126_211826_MerianEM122.all | application/octet-stream | 146.8 MBytes | 0031_20231126_211826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11886.4 | 12.8529 | 6286 | 2023-11-26T21:18:26 | 46.70886940 | -52.2524480 | 6.91 | 114.9779 | 2023-11-26T21:48:25 | 46.81476650 | -52.2311986 | 9.02 | 132.3998 | 2023-11-26T21:18:26 | 46.70886940 | -52.2524480 | -114.9779 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0032_20231126_214826_MerianEM122.all | application/octet-stream | 137.7 MBytes | 0032_20231126_214826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11852.7 | 12.8191 | 5782 | 2023-11-26T21:48:26 | 46.81485455 | -52.2311773 | 9.06 | 132.3448 | 2023-11-26T22:18:25 | 46.92045695 | -52.2099726 | 6.43 | 137.0381 | 2023-11-26T21:48:26 | 46.81485455 | -52.2311773 | -132.3448 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0033_20231126_221826_MerianEM122.all | application/octet-stream | 131.6 MBytes | 0033_20231126_221826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11853.8 | 12.8177 | 5453 | 2023-11-26T22:18:26 | 46.92052530 | -52.2099605 | 6.34 | 136.3291 | 2023-11-26T22:48:25 | 47.02614365 | -52.1887646 | 9.12 | 148.5783 | 2023-11-26T22:18:26 | 46.92052530 | -52.2099605 | -136.3291 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0034_20231126_224827_MerianEM122.all | application/octet-stream | 127.6 MBytes | 0034_20231126_224827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11493.8 | 12.4345 | 5237 | 2023-11-26T22:48:26 | 47.02622520 | -52.1887453 | 9.04 | 148.8597 | 2023-11-26T23:18:25 | 47.12863365 | -52.1681667 | 7.48 | 150.3303 | 2023-11-26T22:48:26 | 47.02622520 | -52.1887453 | -148.8597 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0035_20231126_231826_MerianEM122.all | application/octet-stream | 126.7 MBytes | 0035_20231126_231826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11630.7 | 12.5774 | 5186 | 2023-11-26T23:18:25 | 47.12871920 | -52.1681515 | 7.43 | 150.2672 | 2023-11-26T23:48:25 | 47.23233690 | -52.1471833 | 3.81 | 155.9132 | 2023-11-26T23:18:25 | 47.12871920 | -52.1681515 | -150.2672 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0036_20231126_234826_MerianEM122.all | application/octet-stream | 127.2 MBytes | 0036_20231126_234826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11841.8 | 12.8032 | 5217 | 2023-11-26T23:48:26 | 47.23241890 | -52.1471683 | 4.02 | 155.3784 | 2023-11-27T00:18:25 | 47.33791865 | -52.1258372 | 2.27 | 152.4063 | 2023-11-26T23:48:26 | 47.23241890 | -52.1471683 | -155.3784 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0037_20231127_001827_MerianEM122.all | application/octet-stream | 124.3 MBytes | 0037_20231127_001827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11763.3 | 12.7268 | 5066 | 2023-11-27T00:18:26 | 47.33800120 | -52.1258232 | 2.27 | 152.5625 | 2023-11-27T00:48:25 | 47.44279425 | -52.1045166 | 1.81 | 157.7980 | 2023-11-27T00:18:26 | 47.33800120 | -52.1258232 | -152.5625 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0038_20231127_004826_MerianEM122.all | application/octet-stream | 119.9 MBytes | 0038_20231127_004826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11779.0 | 12.7380 | 4822 | 2023-11-27T00:48:25 | 47.44288565 | -52.1045017 | 1.72 | 157.6433 | 2023-11-27T01:18:25 | 47.54781535 | -52.0831622 | 3.50 | 172.7972 | 2023-11-27T00:48:25 | 47.44288565 | -52.1045017 | -157.6433 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0039_20231127_011826_MerianEM122.all | application/octet-stream | 114.1 MBytes | 0039_20231127_011826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11879.6 | 12.8486 | 4511 | 2023-11-27T01:18:26 | 47.54790275 | -52.0831503 | 3.45 | 172.6920 | 2023-11-27T01:48:25 | 47.65245755 | -52.0544310 | 23.65 | 180.7866 | 2023-11-27T01:18:26 | 47.54790275 | -52.0831503 | -172.6920 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0040_20231127_014826_MerianEM122.all | application/octet-stream | 110.4 MBytes | 0040_20231127_014826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11797.7 | 12.7623 | 4310 | 2023-11-27T01:48:26 | 47.65254090 | -52.0543720 | 23.64 | 180.1423 | 2023-11-27T02:18:24 | 47.74939190 | -51.9902666 | 23.17 | 189.8601 | 2023-11-27T01:48:26 | 47.65254090 | -52.0543720 | -180.1423 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0041_20231127_021826_MerianEM122.all | application/octet-stream | 106.9 MBytes | 0041_20231127_021826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11716.8 | 12.6729 | 4118 | 2023-11-27T02:18:25 | 47.74948970 | -51.9901979 | 22.98 | 190.0293 | 2023-11-27T02:48:24 | 47.84566040 | -51.9263450 | 19.73 | 194.5190 | 2023-11-27T02:18:25 | 47.74948970 | -51.9901979 | -190.0293 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0042_20231127_024826_MerianEM122.all | application/octet-stream | 107.3 MBytes | 0042_20231127_024826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 30.000 | 11989.1 | 12.9616 | 4132 | 2023-11-27T02:48:25 | 47.84576180 | -51.9262771 | 19.62 | 196.7661 | 2023-11-27T03:18:25 | 47.94766670 | -51.8768140 | 6.19 | 194.7635 | 2023-11-27T02:48:25 | 47.84576180 | -51.9262771 | -196.7661 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0043_20231127_031827_MerianEM122.all | application/octet-stream | 106.8 MBytes | 0043_20231127_031827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11772.4 | 12.7355 | 4113 | 2023-11-27T03:18:26 | 47.94776090 | -51.8767917 | 6.41 | 193.4277 | 2023-11-27T03:48:25 | 48.05173210 | -51.8471946 | 8.96 | 192.2267 | 2023-11-27T03:18:26 | 47.94776090 | -51.8767917 | -193.4277 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0044_20231127_034826_MerianEM122.all | application/octet-stream | 106.6 MBytes | 0044_20231127_034826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11695.4 | 12.6483 | 4105 | 2023-11-27T03:48:26 | 48.05184130 | -51.8471556 | 8.98 | 192.7337 | 2023-11-27T04:18:25 | 48.15513410 | -51.8177108 | 9.57 | 191.6557 | 2023-11-27T03:48:26 | 48.05184130 | -51.8471556 | -192.7337 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0045_20231127_041827_MerianEM122.all | application/octet-stream | 106.4 MBytes | 0045_20231127_041827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11741.5 | 12.7034 | 4095 | 2023-11-27T04:18:26 | 48.15523450 | -51.8176803 | 9.60 | 191.8342 | 2023-11-27T04:48:24 | 48.25890620 | -51.7878208 | 9.19 | 199.4806 | 2023-11-27T04:18:26 | 48.15523450 | -51.8176803 | -191.8342 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0046_20231127_044826_MerianEM122.all | application/octet-stream | 104.7 MBytes | 0046_20231127_044826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 30.000 | 11871.3 | 12.8343 | 3996 | 2023-11-27T04:48:25 | 48.25901125 | -51.7877913 | 9.16 | 199.2479 | 2023-11-27T05:18:25 | 48.36383835 | -51.7576945 | 8.45 | 200.3037 | 2023-11-27T04:48:25 | 48.25901125 | -51.7877913 | -199.2479 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0047_20231127_051827_MerianEM122.all | application/octet-stream | 103 MBytes | 0047_20231127_051827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11989.2 | 12.9714 | 3899 | 2023-11-27T05:18:26 | 48.36395390 | -51.7576593 | 8.31 | 200.3525 | 2023-11-27T05:48:25 | 48.46982535 | -51.7272045 | 9.65 | 204.9909 | 2023-11-27T05:18:26 | 48.36395390 | -51.7576593 | -200.3525 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0048_20231127_054826_MerianEM122.all | application/octet-stream | 102.1 MBytes | 0048_20231127_054826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 12036.8 | 13.0172 | 3848 | 2023-11-27T05:48:26 | 48.46994640 | -51.7271685 | 9.52 | 204.5023 | 2023-11-27T06:18:25 | 48.57623550 | -51.6965043 | 7.41 | 212.7021 | 2023-11-27T05:48:26 | 48.46994640 | -51.7271685 | -204.5023 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0049_20231127_061827_MerianEM122.all | application/octet-stream | 100.6 MBytes | 0049_20231127_061827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11956.2 | 12.9310 | 3771 | 2023-11-27T06:18:26 | 48.57633960 | -51.6964758 | 7.37 | 211.5323 | 2023-11-27T06:48:25 | 48.68192560 | -51.6660944 | 5.93 | 222.5155 | 2023-11-27T06:18:26 | 48.57633960 | -51.6964758 | -211.5323 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0050_20231127_064827_MerianEM122.all | application/octet-stream | 87.3 MBytes | 0050_20231127_064827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 11796.6 | 12.7682 | 3039 | 2023-11-27T06:48:26 | 48.68204975 | -51.6660584 | 5.96 | 222.7053 | 2023-11-27T07:18:24 | 48.78619270 | -51.6358175 | 9.22 | 279.9620 | 2023-11-27T06:48:26 | 48.68204975 | -51.6660584 | -222.7053 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0051_20231127_071826_MerianEM122.all | application/octet-stream | 82 MBytes | 0051_20231127_071826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11811.7 | 12.7760 | 2748 | 2023-11-27T07:18:25 | 48.78635145 | -51.6357651 | 9.11 | 280.3588 | 2023-11-27T07:48:24 | 48.89062545 | -51.6053567 | 7.26 | 296.4763 | 2023-11-27T07:18:25 | 48.78635145 | -51.6357651 | -280.3588 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0052_20231127_074827_MerianEM122.all | application/octet-stream | 80 MBytes | 0052_20231127_074827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11851.2 | 12.8188 | 2634 | 2023-11-27T07:48:26 | 48.89080095 | -51.6053055 | 6.81 | 296.5766 | 2023-11-27T08:18:25 | 48.99545065 | -51.5750156 | 7.55 | 298.8317 | 2023-11-27T07:48:26 | 48.89080095 | -51.6053055 | -296.5766 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0053_20231127_081827_MerianEM122.all | application/octet-stream | 80.8 MBytes | 0053_20231127_081827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 11539.7 | 12.4892 | 2669 | 2023-11-27T08:18:26 | 48.99559890 | -51.5749652 | 7.80 | 299.3879 | 2023-11-27T08:48:24 | 49.09748375 | -51.5452529 | 5.35 | 318.1169 | 2023-11-27T08:18:26 | 48.99559890 | -51.5749652 | -299.3879 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0054_20231127_084827_MerianEM122.all | application/octet-stream | 76.7 MBytes | 0054_20231127_084827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11419.1 | 12.3546 | 2433 | 2023-11-27T08:48:25 | 49.09763485 | -51.5452122 | 5.70 | 318.3668 | 2023-11-27T09:18:24 | 49.19846790 | -51.5158608 | 6.60 | 324.0829 | 2023-11-27T08:48:25 | 49.09763485 | -51.5452122 | -318.3668 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0055_20231127_091827_MerianEM122.all | application/octet-stream | 76.2 MBytes | 0055_20231127_091827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11523.0 | 12.4681 | 2392 | 2023-11-27T09:18:26 | 49.19864860 | -51.5158081 | 6.92 | 324.8001 | 2023-11-27T09:48:24 | 49.30038655 | -51.4860210 | 7.52 | 323.4536 | 2023-11-27T09:18:26 | 49.19864860 | -51.5158081 | -324.8001 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0056_20231127_094827_MerianEM122.all | application/octet-stream | 76.2 MBytes | 0056_20231127_094827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11639.4 | 12.5928 | 2389 | 2023-11-27T09:48:25 | 49.30054605 | -51.4859777 | 7.64 | 323.1168 | 2023-11-27T10:18:24 | 49.40331755 | -51.4559137 | 9.72 | 328.9349 | 2023-11-27T09:48:25 | 49.30054605 | -51.4859777 | -323.1168 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0057_20231127_101827_MerianEM122.all | application/octet-stream | 76.7 MBytes | 0057_20231127_101827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11680.1 | 12.6373 | 2421 | 2023-11-27T10:18:26 | 49.40350040 | -51.4558513 | 9.77 | 329.1914 | 2023-11-27T10:48:24 | 49.50660315 | -51.4254959 | 9.15 | 313.1660 | 2023-11-27T10:18:26 | 49.40350040 | -51.4558513 | -329.1914 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0058_20231127_104827_MerianEM122.all | application/octet-stream | 82.3 MBytes | 0058_20231127_104827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11615.0 | 12.5649 | 2738 | 2023-11-27T10:48:26 | 49.50678600 | -51.4254431 | 9.62 | 313.5558 | 2023-11-27T11:18:24 | 49.60932620 | -51.3952208 | 10.48 | 256.8094 | 2023-11-27T10:48:26 | 49.50678600 | -51.4254431 | -313.5558 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0059_20231127_111827_MerianEM122.all | application/octet-stream | 86.1 MBytes | 0059_20231127_111827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11635.3 | 12.5828 | 2938 | 2023-11-27T11:18:25 | 49.60945965 | -51.3951822 | 10.46 | 256.0511 | 2023-11-27T11:48:25 | 49.71217230 | -51.3648132 | 7.81 | 278.4151 | 2023-11-27T11:18:25 | 49.60945965 | -51.3951822 | -256.0511 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0060_20231127_114827_MerianEM122.all | application/octet-stream | 82.5 MBytes | 0060_20231127_114827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11218.2 | 12.1375 | 2738 | 2023-11-27T11:48:26 | 49.71233435 | -51.3647617 | 7.63 | 278.9965 | 2023-11-27T12:18:25 | 49.81136480 | -51.3354372 | 9.26 | 289.5816 | 2023-11-27T11:48:26 | 49.71233435 | -51.3647617 | -278.9965 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0061_20231127_121827_MerianEM122.all | application/octet-stream | 78.8 MBytes | 0061_20231127_121827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 11114.4 | 12.0312 | 2530 | 2023-11-27T12:18:26 | 49.81150350 | -51.3353914 | 9.50 | 289.6697 | 2023-11-27T12:48:24 | 49.90963860 | -51.3064561 | 7.73 | 315.5502 | 2023-11-27T12:18:26 | 49.81150350 | -51.3353914 | -289.6697 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0062_20231127_124827_MerianEM122.all | application/octet-stream | 76.4 MBytes | 0062_20231127_124827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11054.5 | 11.9590 | 2397 | 2023-11-27T12:48:25 | 49.90980430 | -51.3064143 | 7.61 | 318.2765 | 2023-11-27T13:18:24 | 50.00738225 | -51.2773875 | 9.79 | 319.2100 | 2023-11-27T12:48:25 | 49.90980430 | -51.3064143 | -318.2765 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0063_20231127_131827_MerianEM122.all | application/octet-stream | 75.2 MBytes | 0063_20231127_131827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 11096.7 | 12.0110 | 2337 | 2023-11-27T13:18:25 | 50.00755780 | -51.2773306 | 9.77 | 318.5341 | 2023-11-27T13:48:23 | 50.10553745 | -51.2483088 | 9.65 | 337.3878 | 2023-11-27T13:18:25 | 50.00755780 | -51.2773306 | -318.5341 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0064_20231127_134826_MerianEM122.all | application/octet-stream | 75.9 MBytes | 0064_20231127_134826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11480.5 | 12.4169 | 2378 | 2023-11-27T13:48:25 | 50.10570140 | -51.2482576 | 9.32 | 340.5642 | 2023-11-27T14:18:24 | 50.20703475 | -51.2179308 | 8.07 | 332.6732 | 2023-11-27T13:48:25 | 50.10570140 | -51.2482576 | -340.5642 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0065_20231127_141827_MerianEM122.all | application/octet-stream | 74.5 MBytes | 0065_20231127_141827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 11787.4 | 12.7575 | 2303 | 2023-11-27T14:18:26 | 50.20722445 | -51.2178776 | 7.76 | 332.3309 | 2023-11-27T14:48:24 | 50.31128070 | -51.1868557 | 6.66 | 320.3818 | 2023-11-27T14:18:26 | 50.20722445 | -51.2178776 | -332.3309 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0066_20231127_144826_MerianEM122.all | application/octet-stream | 76.6 MBytes | 0066_20231127_144826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 11601.8 | 12.5511 | 2414 | 2023-11-27T14:48:25 | 50.31146450 | -51.1868074 | 6.62 | 321.9907 | 2023-11-27T15:18:24 | 50.41387625 | -51.1561632 | 6.03 | 305.0292 | 2023-11-27T14:48:25 | 50.31146450 | -51.1868074 | -321.9907 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0067_20231127_151827_MerianEM122.all | application/octet-stream | 79.6 MBytes | 0067_20231127_151827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 11729.8 | 12.6907 | 2584 | 2023-11-27T15:18:25 | 50.41404490 | -51.1561195 | 6.04 | 305.0609 | 2023-11-27T15:48:24 | 50.51708455 | -51.1214818 | 9.10 | 305.9355 | 2023-11-27T15:18:25 | 50.41404490 | -51.1561195 | -305.0609 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0068_20231127_154827_MerianEM122.all | application/octet-stream | 77 MBytes | 0068_20231127_154827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11883.3 | 12.8499 | 2441 | 2023-11-27T15:48:25 | 50.51726110 | -51.1214240 | 9.21 | 308.3133 | 2023-11-27T16:18:25 | 50.62213595 | -51.0897535 | 10.46 | 325.4011 | 2023-11-27T15:48:25 | 50.51726110 | -51.1214240 | -308.3133 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0069_20231127_161828_MerianEM122.all | application/octet-stream | 70.8 MBytes | 0069_20231127_161828_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.958 | 11635.9 | 12.5979 | 2117 | 2023-11-27T16:18:26 | 50.62231010 | -51.0896965 | 10.61 | 327.4142 | 2023-11-27T16:48:24 | 50.72501810 | -51.0587344 | 11.23 | 364.8139 | 2023-11-27T16:18:26 | 50.62231010 | -51.0896965 | -327.4142 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0070_20231127_164827_MerianEM122.all | application/octet-stream | 74.6 MBytes | 0070_20231127_164827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 11641.5 | 12.5975 | 2311 | 2023-11-27T16:48:25 | 50.72521965 | -51.0586675 | 10.86 | 364.7261 | 2023-11-27T17:18:24 | 50.82794855 | -51.0273972 | 11.02 | 298.8360 | 2023-11-27T16:48:25 | 50.72521965 | -51.0586675 | -364.7261 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0071_20231127_171826_MerianEM122.all | application/octet-stream | 76.4 MBytes | 0071_20231127_171826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 11885.2 | 12.8545 | 2413 | 2023-11-27T17:18:25 | 50.82810695 | -51.0273449 | 11.55 | 298.2902 | 2023-11-27T17:48:24 | 50.93300065 | -50.9955176 | 11.18 | 321.6291 | 2023-11-27T17:18:25 | 50.82810695 | -51.0273449 | -298.2902 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0072_20231127_174827_MerianEM122.all | application/octet-stream | 77 MBytes | 0072_20231127_174827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 11641.2 | 12.5970 | 2453 | 2023-11-27T17:48:26 | 50.93317895 | -50.9954630 | 11.47 | 322.0236 | 2023-11-27T18:18:24 | 51.03591585 | -50.9641986 | 10.41 | 312.1773 | 2023-11-27T17:48:26 | 50.93317895 | -50.9954630 | -322.0236 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0073_20231127_181827_MerianEM122.all | application/octet-stream | 79.6 MBytes | 0073_20231127_181827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 11601.0 | 12.5532 | 2597 | 2023-11-27T18:18:25 | 51.03607375 | -50.9641523 | 10.17 | 312.4322 | 2023-11-27T18:48:24 | 51.13845050 | -50.9328796 | 14.19 | 287.1711 | 2023-11-27T18:18:25 | 51.03607375 | -50.9641523 | -312.4322 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0074_20231127_184826_MerianEM122.all | application/octet-stream | 82.7 MBytes | 0074_20231127_184826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11518.1 | 12.4533 | 2787 | 2023-11-27T18:48:25 | 51.13859065 | -50.9328315 | 13.87 | 287.0263 | 2023-11-27T19:18:25 | 51.24024605 | -50.9017904 | 8.62 | 277.1037 | 2023-11-27T18:48:25 | 51.13859065 | -50.9328315 | -287.0263 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0075_20231127_191827_MerianEM122.all | application/octet-stream | 87.1 MBytes | 0075_20231127_191827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 11543.8 | 12.4919 | 3015 | 2023-11-27T19:18:26 | 51.24038065 | -50.9017622 | 8.64 | 275.3353 | 2023-11-27T19:48:24 | 51.34225950 | -50.8706537 | 8.91 | 252.9261 | 2023-11-27T19:18:26 | 51.24038065 | -50.9017622 | -275.3353 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0076_20231127_194827_MerianEM122.all | application/octet-stream | 85.3 MBytes | 0076_20231127_194827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 11499.1 | 12.4351 | 2904 | 2023-11-27T19:48:26 | 51.34239495 | -50.8706156 | 8.88 | 253.9600 | 2023-11-27T20:18:25 | 51.44386015 | -50.8393494 | 10.01 | 285.4155 | 2023-11-27T19:48:26 | 51.34239495 | -50.8706156 | -253.9600 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0077_20231127_201828_MerianEM122.all | application/octet-stream | 81.7 MBytes | 0077_20231127_201828_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.958 | 11683.4 | 12.6490 | 2709 | 2023-11-27T20:18:26 | 51.44401875 | -50.8392997 | 10.60 | 286.4308 | 2023-11-27T20:48:24 | 51.54711775 | -50.8075273 | 11.66 | 296.5347 | 2023-11-27T20:18:26 | 51.44401875 | -50.8392997 | -286.4308 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0078_20231127_204826_MerianEM122.all | application/octet-stream | 76.9 MBytes | 0078_20231127_204826_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 12049.3 | 13.0279 | 2441 | 2023-11-27T20:48:25 | 51.54726760 | -50.8074779 | 11.77 | 298.1704 | 2023-11-27T21:18:25 | 51.65361390 | -50.7747957 | 9.97 | 327.9281 | 2023-11-27T20:48:25 | 51.54726760 | -50.8074779 | -298.1704 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0079_20231127_211828_MerianEM122.all | application/octet-stream | 76.9 MBytes | 0079_20231127_211828_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 12056.9 | 13.0481 | 2437 | 2023-11-27T21:18:26 | 51.65378880 | -50.7747433 | 10.15 | 327.8610 | 2023-11-27T21:48:24 | 51.76015515 | -50.7417042 | 9.15 | 332.1457 | 2023-11-27T21:18:26 | 51.65378880 | -50.7747433 | -327.8610 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0080_20231127_214827_MerianEM122.all | application/octet-stream | 72.4 MBytes | 0080_20231127_214827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 11939.0 | 12.9226 | 2189 | 2023-11-27T21:48:26 | 51.76035595 | -50.7416372 | 9.26 | 332.7844 | 2023-11-27T22:18:24 | 51.86571890 | -50.7091233 | 9.70 | 393.3811 | 2023-11-27T21:48:26 | 51.76035595 | -50.7416372 | -332.7844 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0081_20231127_221828_MerianEM122.all | application/octet-stream | 57.2 MBytes | 0081_20231127_221828_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.940 | 11804.4 | 12.7864 | 1377 | 2023-11-27T22:18:26 | 51.86595225 | -50.7090437 | 9.95 | 392.7588 | 2023-11-27T22:48:22 | 51.97009860 | -50.6765568 | 8.81 | 833.0619 | 2023-11-27T22:18:26 | 51.86595225 | -50.7090437 | -392.7588 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0082_20231127_224830_MerianEM122.all | application/octet-stream | 36.5 MBytes | 0082_20231127_224830_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 11692.9 | 12.7026 | 641 | 2023-11-27T22:48:26 | 51.97056060 | -50.6763939 | 8.17 | 831.8815 | 2023-11-27T23:18:18 | 52.07373980 | -50.6442119 | 6.99 | 1449.9143 | 2023-11-27T22:48:26 | 51.97056060 | -50.6763939 | -831.8815 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0083_20231127_231833_MerianEM122.all | application/octet-stream | 28.1 MBytes | 0083_20231127_231833_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.820 | 11272.0 | 12.2584 | 422 | 2023-11-27T23:18:25 | 52.07463765 | -50.6439090 | 6.75 | 1450.6819 | 2023-11-27T23:48:15 | 52.17410755 | -50.6129080 | 7.21 | 1766.3173 | 2023-11-27T23:18:25 | 52.07463765 | -50.6439090 | -1450.6819 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0084_20231127_234833_MerianEM122.all | application/octet-stream | 27 MBytes | 0084_20231127_234833_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.772 | 11152.9 | 12.1497 | 370 | 2023-11-27T23:48:24 | 52.17512745 | -50.6125637 | 5.09 | 1769.0219 | 2023-11-28T00:18:10 | 52.27353405 | -50.5817285 | 7.15 | 1978.8003 | 2023-11-27T23:48:24 | 52.17512745 | -50.6125637 | -1769.0219 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0085_20231128_001831_MerianEM122.all | application/octet-stream | 25.5 MBytes | 0085_20231128_001831_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.892 | 11354.7 | 12.3193 | 338 | 2023-11-28T00:18:20 | 52.27466800 | -50.5813853 | 7.44 | 1978.3882 | 2023-11-28T00:48:14 | 52.37488415 | -50.5501464 | 9.05 | 2158.7964 | 2023-11-28T00:18:20 | 52.27466800 | -50.5813853 | -1978.3882 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0086_20231128_004836_MerianEM122.all | application/octet-stream | 24.7 MBytes | 0086_20231128_004836_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.754 | 11215.8 | 12.2242 | 318 | 2023-11-28T00:48:25 | 52.37610710 | -50.5497249 | 8.37 | 2161.0530 | 2023-11-28T01:18:10 | 52.47508440 | -50.5187121 | 7.31 | 2347.5374 | 2023-11-28T00:48:25 | 52.37610710 | -50.5497249 | -2161.0530 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0087_20231128_011833_MerianEM122.all | application/octet-stream | 24.5 MBytes | 0087_20231128_011833_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 11569.6 | 12.5595 | 302 | 2023-11-28T01:18:21 | 52.47636900 | -50.5183229 | 7.10 | 2350.0283 | 2023-11-28T01:48:14 | 52.57844845 | -50.4861064 | 10.55 | 2565.8062 | 2023-11-28T01:18:21 | 52.47636900 | -50.5183229 | -2350.0283 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0088_20231128_014836_MerianEM122.all | application/octet-stream | 23.7 MBytes | 0088_20231128_014836_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 11657.7 | 12.7371 | 282 | 2023-11-28T01:48:25 | 52.57977545 | -50.4856431 | 9.84 | 2567.5691 | 2023-11-28T02:18:06 | 52.68264920 | -50.4533023 | 9.75 | 2689.7327 | 2023-11-28T01:48:25 | 52.57977545 | -50.4856431 | -2567.5691 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0089_20231128_021833_MerianEM122.all | application/octet-stream | 22.1 MBytes | 0089_20231128_021833_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.724 | 11739.2 | 12.8093 | 259 | 2023-11-28T02:18:20 | 52.68421660 | -50.4527261 | 11.41 | 2686.1594 | 2023-11-28T02:48:03 | 52.78779410 | -50.4199567 | 7.18 | 2883.0115 | 2023-11-28T02:18:20 | 52.68421660 | -50.4527261 | -2686.1594 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0090_20231128_024831_MerianEM122.all | application/octet-stream | 21.8 MBytes | 0090_20231128_024831_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 11817.8 | 12.8297 | 249 | 2023-11-28T02:48:17 | 52.78949290 | -50.4195032 | 9.44 | 2879.9131 | 2023-11-28T03:18:09 | 52.89375425 | -50.3863666 | 11.05 | 3017.3115 | 2023-11-28T02:48:17 | 52.78949290 | -50.4195032 | -2879.9131 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0091_20231128_031839_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0091_20231128_031839_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.778 | 11772.9 | 12.8234 | 236 | 2023-11-28T03:18:24 | 52.89546430 | -50.3857365 | 11.28 | 3025.0623 | 2023-11-28T03:48:10 | 52.99933870 | -50.3527007 | 9.25 | 3162.6870 | 2023-11-28T03:18:24 | 52.89546430 | -50.3857365 | -3025.0623 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0092_20231128_034841_MerianEM122.all | application/octet-stream | 21 MBytes | 0092_20231128_034841_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.592 | 11776.4 | 12.9059 | 228 | 2023-11-28T03:48:26 | 53.00113760 | -50.3521549 | 9.63 | 3167.6365 | 2023-11-28T04:18:02 | 53.10506150 | -50.3191996 | 11.25 | 3371.0195 | 2023-11-28T03:48:26 | 53.00113760 | -50.3521549 | -3167.6365 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0093_20231128_041833_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0093_20231128_041833_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.646 | 12062.8 | 13.1961 | 223 | 2023-11-28T04:18:17 | 53.10689280 | -50.3185204 | 12.28 | 3368.1433 | 2023-11-28T04:47:56 | 53.21329250 | -50.2842918 | 8.88 | 3373.2793 | 2023-11-28T04:18:17 | 53.10689280 | -50.3185204 | -3368.1433 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0094_20231128_044828_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0094_20231128_044828_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.802 | 12135.6 | 13.2062 | 221 | 2023-11-28T04:48:12 | 53.21527095 | -50.2837708 | 9.46 | 3369.6636 | 2023-11-28T05:18:00 | 53.32215890 | -50.2479593 | 8.02 | 3429.2954 | 2023-11-28T04:48:12 | 53.21527095 | -50.2837708 | -3369.6636 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0095_20231128_051833_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0095_20231128_051833_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 5578.3 | 6.0920 | 226 | 2023-11-28T05:18:16 | 53.32392880 | -50.2475057 | 5.41 | 3429.5398 | 2023-11-28T05:47:58 | 53.37088550 | -50.2326028 | 168.47 | 3463.0479 | 2023-11-28T05:18:16 | 53.32392880 | -50.2475057 | -3429.5398 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0096_20231128_054831_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0096_20231128_054831_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.928 | 707.3 | 0.7665 | 282 | 2023-11-28T05:48:15 | 53.37090310 | -50.2324638 | 168.28 | 3464.0942 | 2023-11-28T06:18:10 | 53.37372345 | -50.2339048 | 167.82 | 3462.7905 | 2023-11-28T05:48:15 | 53.37090310 | -50.2324638 | -3464.0942 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0097_20231128_061827_MerianEM122.all | application/octet-stream | 5.6 MBytes | 0097_20231128_061827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 7.386 | 194.3 | 0.8530 | 68 | 2023-11-28T06:18:18 | 53.37375985 | -50.2339627 | 166.82 | 3464.9504 | 2023-11-28T06:25:41 | 53.37330025 | -50.2318658 | 155.06 | 3464.4563 | 2023-11-28T06:18:18 | 53.37375985 | -50.2339627 | -3464.9504 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0000_20231128_155809_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0000_20231128_155809_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.532 | 8400.4 | 9.2263 | 227 | 2023-11-28T15:58:00 | 53.46390045 | -50.2347538 | 157.61 | 3476.3596 | 2023-11-28T16:27:31 | 53.41596600 | -50.3311771 | 223.73 | 3404.6506 | 2023-11-28T15:58:00 | 53.46390045 | -50.2347538 | -3476.3596 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0001_20231128_162804_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0001_20231128_162804_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.688 | 9117.2 | 9.9592 | 223 | 2023-11-28T16:27:47 | 53.41500530 | -50.3330963 | 225.83 | 3402.1392 | 2023-11-28T16:57:29 | 53.35998305 | -50.4344929 | 217.92 | 3244.1992 | 2023-11-28T16:27:47 | 53.41500530 | -50.3330963 | -3402.1392 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0002_20231128_165801_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0002_20231128_165801_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.718 | 9606.2 | 10.4831 | 228 | 2023-11-28T16:57:45 | 53.35893075 | -50.4363960 | 217.68 | 3245.4233 | 2023-11-28T17:27:28 | 53.30003210 | -50.5416852 | 221.72 | 3203.5754 | 2023-11-28T16:57:45 | 53.35893075 | -50.4363960 | -3245.4233 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0003_20231128_172800_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0003_20231128_172800_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.766 | 9626.5 | 10.4888 | 225 | 2023-11-28T17:27:44 | 53.29899340 | -50.5437101 | 222.11 | 3204.2356 | 2023-11-28T17:57:30 | 53.24011540 | -50.6493365 | 221.11 | 3106.0071 | 2023-11-28T17:27:44 | 53.29899340 | -50.5437101 | -3204.2356 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0004_20231128_175800_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0004_20231128_175800_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.862 | 9210.7 | 10.0028 | 235 | 2023-11-28T17:57:45 | 53.23910875 | -50.6511591 | 219.07 | 3105.8772 | 2023-11-28T18:27:37 | 53.18389380 | -50.7536683 | 218.63 | 3008.5730 | 2023-11-28T17:57:45 | 53.23910875 | -50.6511591 | -3105.8772 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0005_20231128_182807_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0005_20231128_182807_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.694 | 8965.4 | 9.7918 | 238 | 2023-11-28T18:27:52 | 53.18299165 | -50.7552508 | 216.49 | 3005.5015 | 2023-11-28T18:57:34 | 53.13030360 | -50.8565038 | 227.62 | 2915.3438 | 2023-11-28T18:27:52 | 53.18299165 | -50.7552508 | -3005.5015 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0006_20231128_185802_MerianEM122.all | application/octet-stream | 8.9 MBytes | 0006_20231128_185802_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 12.366 | 2093.0 | 5.4903 | 106 | 2023-11-28T18:57:48 | 53.12966485 | -50.8582919 | 228.45 | 2911.0569 | 2023-11-28T19:10:10 | 53.11852740 | -50.8805485 | 126.17 | 3200.7132 | 2023-11-28T18:57:48 | 53.12966485 | -50.8582919 | -2911.0569 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0007_20231128_212134_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0007_20231128_212134_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 28.434 | 7337.2 | 8.3688 | 250 | 2023-11-28T21:21:28 | 53.11701600 | -50.8824434 | 182.06 | 3596.1033 | 2023-11-28T21:49:54 | 53.06248015 | -50.9432868 | 201.31 | 2877.6038 | 2023-11-28T21:21:28 | 53.11701600 | -50.8824434 | -3596.1033 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0008_20231128_215033_MerianEM122.all | application/octet-stream | 22.5 MBytes | 0008_20231128_215033_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 7755.0 | 8.4579 | 293 | 2023-11-28T21:50:20 | 53.06092915 | -50.9447605 | 203.79 | 2852.1909 | 2023-11-28T22:20:04 | 52.99973525 | -50.9997208 | 201.64 | 2751.5508 | 2023-11-28T21:50:20 | 53.06092915 | -50.9447605 | -2852.1909 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0009_20231128_222027_MerianEM122.all | application/octet-stream | 22.9 MBytes | 0009_20231128_222027_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.340 | 7421.6 | 8.2039 | 314 | 2023-11-28T22:20:16 | 52.99898165 | -51.0004226 | 198.67 | 2751.6211 | 2023-11-28T22:49:36 | 52.93977685 | -51.0510412 | 200.64 | 2600.1812 | 2023-11-28T22:20:16 | 52.99898165 | -51.0004226 | -2751.6211 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0010_20231128_225024_MerianEM122.all | application/octet-stream | 6.6 MBytes | 0010_20231128_225024_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 11.598 | 776.6 | 2.1723 | 59 | 2023-11-28T22:50:16 | 52.93897680 | -51.0519923 | 198.26 | 2594.8787 | 2023-11-28T23:01:52 | 52.93421305 | -51.0593415 | 149.00 | 2591.5176 | 2023-11-28T22:50:16 | 52.93897680 | -51.0519923 | -2594.8787 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0011_20231129_155355_MerianEM122.all | application/octet-stream | 23.4 MBytes | 0011_20231129_155355_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 8363.3 | 9.1035 | 324 | 2023-11-29T15:53:46 | 52.94614240 | -50.9787296 | 180.30 | 2729.4929 | 2023-11-29T16:23:34 | 52.87117605 | -50.9866820 | 178.42 | 2433.4392 | 2023-11-29T15:53:46 | 52.94614240 | -50.9787296 | -2729.4929 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0012_20231129_162354_MerianEM122.all | application/octet-stream | 25.9 MBytes | 0012_20231129_162354_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 8509.4 | 9.2387 | 358 | 2023-11-29T16:23:44 | 52.87030875 | -50.9867553 | 179.50 | 2427.8010 | 2023-11-29T16:53:37 | 52.80686780 | -51.0076526 | 307.84 | 2294.2939 | 2023-11-29T16:23:44 | 52.87030875 | -50.9867553 | -2427.8010 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0013_20231129_165356_MerianEM122.all | application/octet-stream | 25.9 MBytes | 0013_20231129_165356_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.718 | 9577.4 | 10.4518 | 364 | 2023-11-29T16:53:46 | 52.80739025 | -51.0089022 | 307.11 | 2294.3149 | 2023-11-29T17:23:30 | 52.85596065 | -51.1261206 | 306.88 | 2292.6230 | 2023-11-29T16:53:46 | 52.80739025 | -51.0089022 | -2294.3149 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0014_20231129_172350_MerianEM122.all | application/octet-stream | 25.8 MBytes | 0014_20231129_172350_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.838 | 9896.8 | 10.7584 | 358 | 2023-11-29T17:23:39 | 52.85651375 | -51.1274642 | 304.60 | 2287.8010 | 2023-11-29T17:53:30 | 52.90609620 | -51.2494144 | 307.09 | 2307.9756 | 2023-11-29T17:23:39 | 52.85651375 | -51.1274642 | -2287.8010 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0015_20231129_175349_MerianEM122.all | application/octet-stream | 24.8 MBytes | 0015_20231129_175349_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.958 | 6460.8 | 6.9944 | 331 | 2023-11-29T17:53:39 | 52.90672850 | -51.2508063 | 308.07 | 2303.8701 | 2023-11-29T18:23:37 | 52.94101070 | -51.3221884 | 133.28 | 2193.9084 | 2023-11-29T17:53:39 | 52.90672850 | -51.2508063 | -2303.8701 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0016_20231129_182358_MerianEM122.all | application/octet-stream | 13.6 MBytes | 0016_20231129_182358_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 15.864 | 89.0 | 0.1819 | 180 | 2023-11-29T18:23:47 | 52.94101070 | -51.3221882 | 136.06 | 2194.0244 | 2023-11-29T18:39:39 | 52.94098695 | -51.3221423 | 135.09 | 2204.9036 | 2023-11-29T18:23:47 | 52.94101070 | -51.3221882 | -2194.0244 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0017_20231129_230238_MerianEM122.all | application/octet-stream | 24.8 MBytes | 0017_20231129_230238_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 9398.7 | 10.2113 | 316 | 2023-11-29T23:02:29 | 52.93293000 | -51.3133873 | 339.34 | 2227.7146 | 2023-11-29T23:32:20 | 53.01388295 | -51.3527060 | 340.96 | 2267.1848 | 2023-11-29T23:02:29 | 52.93293000 | -51.3133873 | -2227.7146 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0018_20231129_233242_MerianEM122.all | application/octet-stream | 24.6 MBytes | 0018_20231129_233242_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 9604.3 | 10.4888 | 310 | 2023-11-29T23:32:31 | 53.01493375 | -51.3531340 | 343.54 | 2270.6738 | 2023-11-30T00:02:13 | 53.09840790 | -51.3892221 | 341.44 | 2277.0830 | 2023-11-29T23:32:31 | 53.01493375 | -51.3531340 | -2270.6738 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0019_20231130_000235_MerianEM122.all | application/octet-stream | 24.5 MBytes | 0019_20231130_000235_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.778 | 9590.7 | 10.4449 | 300 | 2023-11-30T00:02:23 | 53.09946900 | -51.3896923 | 339.46 | 2278.3171 | 2023-11-30T00:32:10 | 53.18279305 | -51.4260407 | 339.08 | 2389.0669 | 2023-11-30T00:02:23 | 53.09946900 | -51.3896923 | -2278.3171 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0020_20231130_003235_MerianEM122.all | application/octet-stream | 24.3 MBytes | 0020_20231130_003235_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.892 | 9223.3 | 10.0075 | 288 | 2023-11-30T00:32:23 | 53.18390065 | -51.4265228 | 339.98 | 2392.0674 | 2023-11-30T01:02:16 | 53.26400510 | -51.4616924 | 342.75 | 2378.1838 | 2023-11-30T00:32:23 | 53.18390065 | -51.4265228 | -2392.0674 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0021_20231130_010241_MerianEM122.all | application/octet-stream | 24.2 MBytes | 0021_20231130_010241_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.694 | 8921.4 | 9.7446 | 292 | 2023-11-30T01:02:29 | 53.26519595 | -51.4621252 | 344.35 | 2376.1565 | 2023-11-30T01:32:10 | 53.34275185 | -51.4956892 | 339.73 | 2347.5500 | 2023-11-30T01:02:29 | 53.26519595 | -51.4621252 | -2376.1565 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0022_20231130_013235_MerianEM122.all | application/octet-stream | 24.5 MBytes | 0022_20231130_013235_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 8664.1 | 9.3755 | 300 | 2023-11-30T01:32:22 | 53.34382090 | -51.4961775 | 341.85 | 2346.6841 | 2023-11-30T02:02:21 | 53.41912745 | -51.5290038 | 340.64 | 2314.0955 | 2023-11-30T01:32:22 | 53.34382090 | -51.4961775 | -2346.6841 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0023_20231130_020245_MerianEM122.all | application/octet-stream | 24.4 MBytes | 0023_20231130_020245_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.748 | 8664.2 | 9.4456 | 300 | 2023-11-30T02:02:33 | 53.42013635 | -51.5295092 | 337.86 | 2309.8750 | 2023-11-30T02:32:18 | 53.49538415 | -51.5626738 | 340.87 | 2331.9431 | 2023-11-30T02:02:33 | 53.42013635 | -51.5295092 | -2309.8750 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0024_20231130_023242_MerianEM122.all | application/octet-stream | 24.3 MBytes | 0024_20231130_023242_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.676 | 8561.4 | 9.3565 | 298 | 2023-11-30T02:32:29 | 53.49643645 | -51.5631068 | 342.39 | 2333.1414 | 2023-11-30T03:02:10 | 53.57083985 | -51.5957120 | 341.59 | 2384.4080 | 2023-11-30T02:32:29 | 53.49643645 | -51.5631068 | -2333.1414 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0025_20231130_030235_MerianEM122.all | application/octet-stream | 24.4 MBytes | 0025_20231130_030235_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.916 | 8866.6 | 9.6124 | 292 | 2023-11-30T03:02:23 | 53.57191470 | -51.5961687 | 343.10 | 2383.8508 | 2023-11-30T03:32:18 | 53.64899590 | -51.6298901 | 341.69 | 2412.0549 | 2023-11-30T03:02:23 | 53.57191470 | -51.5961687 | -2383.8508 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0026_20231130_033243_MerianEM122.all | application/octet-stream | 23.9 MBytes | 0026_20231130_033243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 8989.3 | 9.8054 | 286 | 2023-11-30T03:32:30 | 53.65015010 | -51.6303753 | 340.61 | 2412.3806 | 2023-11-30T04:02:14 | 53.72821230 | -51.6649849 | 342.86 | 2473.0186 | 2023-11-30T03:32:30 | 53.65015010 | -51.6303753 | -2412.3806 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0027_20231130_040238_MerianEM122.all | application/octet-stream | 23.7 MBytes | 0027_20231130_040238_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.862 | 9215.1 | 10.0085 | 282 | 2023-11-30T04:02:26 | 53.72926745 | -51.6653799 | 342.82 | 2472.7532 | 2023-11-30T04:32:18 | 53.80933990 | -51.7006501 | 340.27 | 2682.3838 | 2023-11-30T04:02:26 | 53.72926745 | -51.6653799 | -2472.7532 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0028_20231130_043245_MerianEM122.all | application/octet-stream | 22 MBytes | 0028_20231130_043245_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 9398.0 | 10.2693 | 260 | 2023-11-30T04:32:31 | 53.81059315 | -51.7012031 | 340.43 | 2684.7915 | 2023-11-30T05:02:12 | 53.89226750 | -51.7371031 | 340.96 | 2671.7620 | 2023-11-30T04:32:31 | 53.81059315 | -51.7012031 | -2684.7915 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0029_20231130_050239_MerianEM122.all | application/octet-stream | 22 MBytes | 0029_20231130_050239_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.892 | 9430.3 | 10.2317 | 257 | 2023-11-30T05:02:26 | 53.89350300 | -51.7376539 | 341.92 | 2669.5286 | 2023-11-30T05:32:19 | 53.97542635 | -51.7740964 | 343.05 | 2736.5046 | 2023-11-30T05:02:26 | 53.89350300 | -51.7376539 | -2669.5286 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0030_20231130_053247_MerianEM122.all | application/octet-stream | 21.8 MBytes | 0030_20231130_053247_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.580 | 9497.9 | 10.4139 | 254 | 2023-11-30T05:32:33 | 53.97675425 | -51.7746261 | 339.50 | 2729.0300 | 2023-11-30T06:02:08 | 54.05925390 | -51.8113713 | 340.81 | 2738.9578 | 2023-11-30T05:32:33 | 53.97675425 | -51.7746261 | -2729.0300 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0031_20231130_060236_MerianEM122.all | application/octet-stream | 22.1 MBytes | 0031_20231130_060236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.880 | 9408.4 | 10.2111 | 260 | 2023-11-30T06:02:22 | 54.06058010 | -51.8119824 | 341.01 | 2739.3860 | 2023-11-30T06:32:15 | 54.14234085 | -51.8482359 | 337.52 | 2670.9451 | 2023-11-30T06:02:22 | 54.06058010 | -51.8119824 | -2739.3860 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0032_20231130_063242_MerianEM122.all | application/octet-stream | 22 MBytes | 0032_20231130_063242_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 9120.0 | 9.9304 | 261 | 2023-11-30T06:32:28 | 54.14354615 | -51.8488737 | 339.03 | 2675.8562 | 2023-11-30T07:02:15 | 54.22279760 | -51.8839481 | 339.82 | 2773.9512 | 2023-11-30T06:32:28 | 54.14354615 | -51.8488737 | -2675.8562 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0033_20231130_070243_MerianEM122.all | application/octet-stream | 21.9 MBytes | 0033_20231130_070243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.670 | 9191.4 | 10.0478 | 258 | 2023-11-30T07:02:29 | 54.22402565 | -51.8845111 | 339.61 | 2775.0747 | 2023-11-30T07:32:09 | 54.30384045 | -51.9202476 | 339.31 | 2755.2205 | 2023-11-30T07:02:29 | 54.22402565 | -51.8845111 | -2775.0747 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0034_20231130_073236_MerianEM122.all | application/octet-stream | 22 MBytes | 0034_20231130_073236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 9300.6 | 10.1030 | 261 | 2023-11-30T07:32:23 | 54.30510180 | -51.9208396 | 341.03 | 2755.5081 | 2023-11-30T08:02:14 | 54.38586765 | -51.9569699 | 345.57 | 2758.7493 | 2023-11-30T07:32:23 | 54.30510180 | -51.9208396 | -2755.5081 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0035_20231130_080241_MerianEM122.all | application/octet-stream | 22.3 MBytes | 0035_20231130_080241_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.868 | 9300.0 | 10.0981 | 268 | 2023-11-30T08:02:28 | 54.38710970 | -51.9574262 | 341.96 | 2760.9504 | 2023-11-30T08:32:20 | 54.46791590 | -51.9933548 | 340.46 | 2624.8977 | 2023-11-30T08:02:28 | 54.38710970 | -51.9574262 | -2760.9504 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0036_20231130_083245_MerianEM122.all | application/octet-stream | 22.5 MBytes | 0036_20231130_083245_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.628 | 8608.6 | 9.4235 | 277 | 2023-11-30T08:32:33 | 54.46900545 | -51.9939543 | 339.25 | 2640.0872 | 2023-11-30T09:02:10 | 54.54374740 | -52.0275777 | 340.74 | 2549.2131 | 2023-11-30T08:32:33 | 54.46900545 | -51.9939543 | -2640.0872 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0037_20231130_090236_MerianEM122.all | application/octet-stream | 22.8 MBytes | 0037_20231130_090236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 8579.8 | 9.3281 | 286 | 2023-11-30T09:02:23 | 54.54484540 | -52.0280786 | 339.45 | 2544.0278 | 2023-11-30T09:32:13 | 54.61932200 | -52.0617661 | 341.66 | 2484.7388 | 2023-11-30T09:02:23 | 54.54484540 | -52.0280786 | -2544.0278 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0038_20231130_093237_MerianEM122.all | application/octet-stream | 24.6 MBytes | 0038_20231130_093237_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.958 | 8440.9 | 9.1381 | 316 | 2023-11-30T09:32:25 | 54.62031555 | -52.0620988 | 342.71 | 2479.7764 | 2023-11-30T10:02:22 | 54.69359570 | -52.0950224 | 343.23 | 2365.2024 | 2023-11-30T09:32:25 | 54.62031555 | -52.0620988 | -2479.7764 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0039_20231130_100242_MerianEM122.all | application/octet-stream | 24.6 MBytes | 0039_20231130_100242_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 8758.3 | 9.5635 | 321 | 2023-11-30T10:02:32 | 54.69436245 | -52.0954039 | 343.80 | 2364.1409 | 2023-11-30T10:32:14 | 54.77041395 | -52.1297264 | 340.28 | 2270.3098 | 2023-11-30T10:02:32 | 54.69436245 | -52.0954039 | -2364.1409 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0040_20231130_103236_MerianEM122.all | application/octet-stream | 25.2 MBytes | 0040_20231130_103236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.862 | 9009.5 | 9.7848 | 335 | 2023-11-30T10:32:25 | 54.77139850 | -52.1302224 | 341.28 | 2269.0581 | 2023-11-30T11:02:17 | 54.84960780 | -52.1654842 | 339.78 | 2199.9839 | 2023-11-30T10:32:25 | 54.77139850 | -52.1302224 | -2269.0581 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0041_20231130_110236_MerianEM122.all | application/octet-stream | 25 MBytes | 0041_20231130_110236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.868 | 9112.8 | 9.8962 | 326 | 2023-11-30T11:02:26 | 54.85045900 | -52.1658689 | 336.32 | 2199.9143 | 2023-11-30T11:32:18 | 54.92952240 | -52.2017920 | 340.23 | 2318.1455 | 2023-11-30T11:02:26 | 54.85045900 | -52.1658689 | -2199.9143 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0042_20231130_113239_MerianEM122.all | application/octet-stream | 24 MBytes | 0042_20231130_113239_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.706 | 9454.9 | 10.3217 | 292 | 2023-11-30T11:32:28 | 54.93044300 | -52.2022123 | 337.32 | 2317.3774 | 2023-11-30T12:02:11 | 55.01247220 | -52.2399845 | 334.98 | 2702.5156 | 2023-11-30T11:32:28 | 54.93044300 | -52.2022123 | -2317.3774 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0043_20231130_120238_MerianEM122.all | application/octet-stream | 21.8 MBytes | 0043_20231130_120238_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 8604.3 | 9.3492 | 249 | 2023-11-30T12:02:24 | 55.01363480 | -52.2405888 | 340.08 | 2704.5564 | 2023-11-30T12:32:15 | 55.08840975 | -52.2741255 | 334.55 | 2836.5981 | 2023-11-30T12:02:24 | 55.01363480 | -52.2405888 | -2704.5564 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0044_20231130_123244_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0044_20231130_123244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.790 | 8640.2 | 9.4066 | 245 | 2023-11-30T12:32:30 | 55.08962550 | -52.2748293 | 333.08 | 2834.8960 | 2023-11-30T13:02:17 | 55.16470285 | -52.3086859 | 341.36 | 3021.6460 | 2023-11-30T12:32:30 | 55.08962550 | -52.2748293 | -2834.8960 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0045_20231130_130246_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0045_20231130_130246_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.586 | 8810.5 | 9.6574 | 243 | 2023-11-30T13:02:32 | 55.16601935 | -52.3091818 | 341.31 | 3021.6497 | 2023-11-30T13:32:07 | 55.24249295 | -52.3443813 | 336.11 | 3084.2773 | 2023-11-30T13:02:32 | 55.16601935 | -52.3091818 | -3021.6497 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0046_20231130_133236_MerianEM122.all | application/octet-stream | 22.1 MBytes | 0046_20231130_133236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 8788.8 | 9.5120 | 252 | 2023-11-30T13:32:21 | 55.24376810 | -52.3451237 | 336.92 | 3085.4668 | 2023-11-30T14:02:19 | 55.32011960 | -52.3796214 | 338.65 | 3152.0374 | 2023-11-30T13:32:21 | 55.24376810 | -52.3451237 | -3085.4668 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0047_20231130_140245_MerianEM122.all | application/octet-stream | 21.9 MBytes | 0047_20231130_140245_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.622 | 8707.9 | 9.5346 | 248 | 2023-11-30T14:02:32 | 55.32127125 | -52.3802267 | 340.03 | 3154.2212 | 2023-11-30T14:32:09 | 55.39675780 | -52.4151751 | 343.70 | 3205.8074 | 2023-11-30T14:02:32 | 55.32127125 | -52.3802267 | -3154.2212 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0048_20231130_143235_MerianEM122.all | application/octet-stream | 21.8 MBytes | 0048_20231130_143235_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.910 | 4297.0 | 4.6597 | 311 | 2023-11-30T14:32:22 | 55.39755320 | -52.4153838 | 343.63 | 3206.3625 | 2023-11-30T15:02:16 | 55.42490020 | -52.4421762 | 349.48 | 3211.4868 | 2023-11-30T14:32:22 | 55.39755320 | -52.4153838 | -3206.3625 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0049_20231130_150244_MerianEM122.all | application/octet-stream | 22.1 MBytes | 0049_20231130_150244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 9800.3 | 10.7014 | 255 | 2023-11-30T15:02:30 | 55.42632385 | -52.4424471 | 348.96 | 3215.4475 | 2023-11-30T15:32:12 | 55.51195785 | -52.4725545 | 341.12 | 3264.0662 | 2023-11-30T15:02:30 | 55.42632385 | -52.4424471 | -3215.4475 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0050_20231130_153236_MerianEM122.all | application/octet-stream | 22.4 MBytes | 0050_20231130_153236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 9596.5 | 10.4180 | 262 | 2023-11-30T15:32:24 | 55.51309705 | -52.4729622 | 337.43 | 3263.4688 | 2023-11-30T16:02:17 | 55.59570425 | -52.5157808 | 341.57 | 3287.8076 | 2023-11-30T15:32:24 | 55.51309705 | -52.4729622 | -3263.4688 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0051_20231130_160243_MerianEM122.all | application/octet-stream | 22.5 MBytes | 0051_20231130_160243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 9174.5 | 9.9744 | 264 | 2023-11-30T16:02:30 | 55.59693735 | -52.5163447 | 339.80 | 3287.8699 | 2023-11-30T16:32:20 | 55.67604770 | -52.5563781 | 338.89 | 3289.1216 | 2023-11-30T16:02:30 | 55.59693735 | -52.5163447 | -3287.8699 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0052_20231130_163248_MerianEM122.all | application/octet-stream | 22.2 MBytes | 0052_20231130_163248_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.604 | 8935.3 | 9.7885 | 259 | 2023-11-30T16:32:34 | 55.67727490 | -52.5570070 | 342.11 | 3286.6963 | 2023-11-30T17:02:10 | 55.75433600 | -52.5959033 | 335.63 | 3277.5449 | 2023-11-30T16:32:34 | 55.67727490 | -52.5570070 | -3286.6963 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0053_20231130_170238_MerianEM122.all | application/octet-stream | 22.2 MBytes | 0053_20231130_170238_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.790 | 8943.7 | 9.7368 | 255 | 2023-11-30T17:02:24 | 55.75557095 | -52.5966449 | 336.31 | 3276.7974 | 2023-11-30T17:32:11 | 55.83272120 | -52.6357189 | 338.41 | 3294.3401 | 2023-11-30T17:02:24 | 55.75557095 | -52.5966449 | -3276.7974 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0054_20231130_173239_MerianEM122.all | application/octet-stream | 22.3 MBytes | 0054_20231130_173239_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 9378.7 | 10.2023 | 257 | 2023-11-30T17:32:25 | 55.83397315 | -52.6364693 | 339.60 | 3538.1724 | 2023-11-30T18:02:14 | 55.91483730 | -52.6776955 | 334.19 | 3321.1187 | 2023-11-30T17:32:25 | 55.83397315 | -52.6364693 | -3538.1724 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0055_20231130_180239_MerianEM122.all | application/octet-stream | 21 MBytes | 0055_20231130_180239_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.634 | 9303.6 | 10.1820 | 232 | 2023-11-30T18:02:26 | 55.91594120 | -52.6784837 | 333.04 | 3321.6292 | 2023-11-30T18:32:04 | 55.99618705 | -52.7192735 | 337.75 | 3340.4128 | 2023-11-30T18:02:26 | 55.91594120 | -52.6784837 | -3321.6292 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0056_20231130_183236_MerianEM122.all | application/octet-stream | 21 MBytes | 0056_20231130_183236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.940 | 9186.3 | 9.9513 | 229 | 2023-11-30T18:32:19 | 55.99761965 | -52.7201747 | 337.45 | 3339.2197 | 2023-11-30T19:02:16 | 56.06787135 | -52.7918858 | 314.06 | 3350.2744 | 2023-11-30T18:32:19 | 55.99761965 | -52.7201747 | -3339.2197 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0057_20231130_190246_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0057_20231130_190246_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.694 | 9275.8 | 10.1315 | 225 | 2023-11-30T19:02:31 | 56.06894785 | -52.7935463 | 317.34 | 3349.2659 | 2023-11-30T19:32:12 | 56.13279515 | -52.8891087 | 315.53 | 3404.0754 | 2023-11-30T19:02:31 | 56.06894785 | -52.7935463 | -3349.2659 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0058_20231130_193241_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0058_20231130_193241_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.826 | 9270.8 | 10.0813 | 231 | 2023-11-30T19:32:26 | 56.13381250 | -52.8906944 | 316.31 | 3405.5730 | 2023-11-30T20:02:16 | 56.19522230 | -52.9910437 | 311.57 | 3401.1851 | 2023-11-30T19:32:26 | 56.13381250 | -52.8906944 | -3405.5730 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0059_20231130_200248_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0059_20231130_200248_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 8228.2 | 8.9738 | 229 | 2023-11-30T20:02:32 | 56.19627080 | -52.9927907 | 313.65 | 3398.6848 | 2023-11-30T20:32:16 | 56.24198545 | -53.0962778 | 296.66 | 3426.4412 | 2023-11-30T20:02:32 | 56.19627080 | -52.9927907 | -3398.6848 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0060_20231130_203243_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0060_20231130_203243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.664 | 7024.8 | 7.6809 | 235 | 2023-11-30T20:32:30 | 56.24245825 | -53.0976010 | 293.55 | 3433.3884 | 2023-11-30T21:02:10 | 56.27515845 | -53.1943921 | 290.02 | 3454.7122 | 2023-11-30T20:32:30 | 56.24245825 | -53.0976010 | -3433.3884 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0061_20231130_210239_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0061_20231130_210239_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.706 | 7009.8 | 7.6529 | 251 | 2023-11-30T21:02:24 | 56.27560855 | -53.1956786 | 294.79 | 3462.2183 | 2023-11-30T21:32:07 | 56.31076840 | -53.2891598 | 301.86 | 3459.6892 | 2023-11-30T21:02:24 | 56.27560855 | -53.1956786 | -3462.2183 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0062_20231130_213238_MerianEM122.all | application/octet-stream | 21.5 MBytes | 0062_20231130_213238_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 6560.2 | 7.1001 | 262 | 2023-11-30T21:32:22 | 56.31149845 | -53.2907153 | 304.65 | 3455.5989 | 2023-11-30T22:02:20 | 56.34420950 | -53.3785185 | 293.59 | 3422.6357 | 2023-11-30T21:32:22 | 56.31149845 | -53.2907153 | -3455.5989 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0063_20231130_220245_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0063_20231130_220245_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.610 | 6346.0 | 6.9511 | 232 | 2023-11-30T22:02:33 | 56.34465390 | -53.3796796 | 293.60 | 3424.1123 | 2023-11-30T22:32:09 | 56.37771995 | -53.4631366 | 297.04 | 3375.8193 | 2023-11-30T22:02:33 | 56.34465390 | -53.3796796 | -3424.1123 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0064_20231130_223236_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0064_20231130_223236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.766 | 6359.0 | 6.9284 | 230 | 2023-11-30T22:32:22 | 56.37826675 | -53.4644202 | 298.35 | 3374.5066 | 2023-11-30T23:02:08 | 56.41148220 | -53.5480559 | 290.88 | 3350.8970 | 2023-11-30T22:32:22 | 56.37826675 | -53.4644202 | -3374.5066 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0065_20231130_230238_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0065_20231130_230238_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 5116.4 | 5.5341 | 266 | 2023-11-30T23:02:23 | 56.41196205 | -53.5493519 | 292.13 | 3348.4353 | 2023-11-30T23:32:22 | 56.41903110 | -53.5117626 | 103.59 | 3354.5188 | 2023-11-30T23:02:23 | 56.41196205 | -53.5493519 | -3348.4353 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0066_20231130_233240_MerianEM122.all | application/octet-stream | 21 MBytes | 0066_20231130_233240_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.544 | 4489.9 | 4.9294 | 278 | 2023-11-30T23:32:31 | 56.41901305 | -53.5111702 | 102.85 | 3354.6880 | 2023-12-01T00:02:03 | 56.41691905 | -53.4388345 | 92.44 | 3375.5134 | 2023-11-30T23:32:31 | 56.41901305 | -53.5111702 | -3354.6880 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0067_20231201_000236_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0067_20231201_000236_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 6441.5 | 7.0071 | 224 | 2023-12-01T00:02:20 | 56.41692360 | -53.4368604 | 94.10 | 3376.7690 | 2023-12-01T00:32:09 | 56.42227805 | -53.3330852 | 93.64 | 3405.2021 | 2023-12-01T00:02:20 | 56.41692360 | -53.4368604 | -3376.7690 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0068_20231201_003238_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0068_20231201_003238_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 5991.8 | 6.5104 | 237 | 2023-12-01T00:32:23 | 56.42229210 | -53.3315117 | 91.45 | 3407.1250 | 2023-12-01T01:02:14 | 56.43017710 | -53.2355517 | 84.55 | 3435.0046 | 2023-12-01T00:32:23 | 56.42229210 | -53.3315117 | -3407.1250 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0069_20231201_010244_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0069_20231201_010244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 6019.5 | 6.5515 | 235 | 2023-12-01T01:02:29 | 56.43035005 | -53.2339505 | 84.02 | 3433.7434 | 2023-12-01T01:32:17 | 56.43621890 | -53.1371010 | 89.25 | 3441.8752 | 2023-12-01T01:02:29 | 56.43035005 | -53.2339505 | -3433.7434 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0070_20231201_013249_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0070_20231201_013249_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 6056.3 | 6.6046 | 236 | 2023-12-01T01:32:33 | 56.43630510 | -53.1353025 | 88.50 | 3445.2773 | 2023-12-01T02:02:17 | 56.43926845 | -53.0373565 | 92.68 | 3453.0706 | 2023-12-01T01:32:33 | 56.43630510 | -53.1353025 | -3445.2773 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0071_20231201_020247_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0071_20231201_020247_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.664 | 6088.7 | 6.6576 | 243 | 2023-12-01T02:02:31 | 56.43928440 | -53.0356655 | 94.52 | 3454.5422 | 2023-12-01T02:32:11 | 56.44488750 | -52.9375851 | 91.46 | 3474.0483 | 2023-12-01T02:02:31 | 56.43928440 | -53.0356655 | -3454.5422 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0072_20231201_023241_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0072_20231201_023241_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 2597.4 | 2.8379 | 244 | 2023-12-01T02:32:41 | 56.44489390 | -52.9358846 | 92.58 | 3470.3936 | 2023-12-01T03:02:22 | 56.45115960 | -52.8975998 | 94.09 | 3477.5488 | 2023-12-01T02:32:41 | 56.44489390 | -52.9358846 | -3470.3936 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0073_20231201_030244_MerianEM122.all | application/octet-stream | 8 MBytes | 0073_20231201_030244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 10.776 | 472.6 | 1.4222 | 105 | 2023-12-01T03:02:33 | 56.45125655 | -52.8973937 | 97.72 | 3477.9104 | 2023-12-01T03:13:20 | 56.45405405 | -52.8935439 | 92.12 | 3481.0432 | 2023-12-01T03:02:33 | 56.45125655 | -52.8973937 | -3477.9104 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0074_20231201_161341_MerianEM122.all | application/octet-stream | 20 MBytes | 0074_20231201_161341_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 4687.9 | 5.0895 | 254 | 2023-12-01T16:13:31 | 56.43898275 | -52.9425789 | 346.74 | 3472.1355 | 2023-12-01T16:43:24 | 56.48102295 | -52.9436837 | 352.22 | 3458.3699 | 2023-12-01T16:13:31 | 56.43898275 | -52.9425789 | -3472.1355 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0075_20231201_164341_MerianEM122.all | application/octet-stream | 19.8 MBytes | 0075_20231201_164341_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.664 | 4482.2 | 4.9005 | 248 | 2023-12-01T16:43:32 | 56.48137575 | -52.9436508 | 350.55 | 3458.7605 | 2023-12-01T17:13:12 | 56.52157835 | -52.9443206 | 352.42 | 3460.4380 | 2023-12-01T16:43:32 | 56.48137575 | -52.9436508 | -3458.7605 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0076_20231201_171337_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0076_20231201_171337_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.940 | 4760.5 | 5.1567 | 290 | 2023-12-01T17:13:24 | 56.52218180 | -52.9442977 | 352.06 | 3453.0872 | 2023-12-01T17:43:21 | 56.56485275 | -52.9432535 | 348.72 | 3463.3984 | 2023-12-01T17:13:24 | 56.52218180 | -52.9442977 | -3453.0872 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0077_20231201_174342_MerianEM122.all | application/octet-stream | 21.5 MBytes | 0077_20231201_174342_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.688 | 4564.3 | 4.9864 | 296 | 2023-12-01T17:43:31 | 56.56533795 | -52.9432895 | 349.71 | 3463.9526 | 2023-12-01T18:13:12 | 56.60629165 | -52.9428568 | 350.68 | 3458.1726 | 2023-12-01T17:43:31 | 56.56533795 | -52.9432895 | -3463.9526 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0078_20231201_181342_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0078_20231201_181342_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.766 | 4628.0 | 5.0427 | 280 | 2023-12-01T18:13:32 | 56.60694435 | -52.9428832 | 352.08 | 3461.4780 | 2023-12-01T18:43:18 | 56.64847650 | -52.9436450 | 353.01 | 3455.5515 | 2023-12-01T18:13:32 | 56.60694435 | -52.9428832 | -3461.4780 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0079_20231201_184346_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0079_20231201_184346_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.274 | 4810.5 | 5.3296 | 219 | 2023-12-01T18:43:46 | 56.64913255 | -52.9436600 | 353.22 | 3456.7759 | 2023-12-01T19:13:02 | 56.69230315 | -52.9427820 | 351.53 | 3452.5374 | 2023-12-01T18:43:46 | 56.64913255 | -52.9436600 | -3456.7759 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0080_20231201_191342_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0080_20231201_191342_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.526 | 4576.5 | 5.0272 | 256 | 2023-12-01T19:13:42 | 56.69322175 | -52.9427937 | 352.87 | 3453.7881 | 2023-12-01T19:43:13 | 56.73428940 | -52.9431699 | 342.83 | 3445.5984 | 2023-12-01T19:13:42 | 56.69322175 | -52.9427937 | -3453.7881 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0081_20231201_194337_MerianEM122.all | application/octet-stream | 22 MBytes | 0081_20231201_194337_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 4493.2 | 4.8812 | 303 | 2023-12-01T19:43:25 | 56.73482495 | -52.9433841 | 334.32 | 3441.1653 | 2023-12-01T20:13:16 | 56.73788645 | -53.0147224 | 261.11 | 3444.1333 | 2023-12-01T19:43:25 | 56.73482495 | -52.9433841 | -3441.1653 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0082_20231201_201340_MerianEM122.all | application/octet-stream | 22.1 MBytes | 0082_20231201_201340_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 4576.8 | 4.9813 | 289 | 2023-12-01T20:13:29 | 56.73788385 | -53.0157134 | 262.57 | 3558.7297 | 2023-12-01T20:43:17 | 56.73658045 | -53.0900858 | 228.00 | 3442.9670 | 2023-12-01T20:13:29 | 56.73788385 | -53.0157134 | -3558.7297 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0083_20231201_204338_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0083_20231201_204338_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 4462.8 | 4.8522 | 236 | 2023-12-01T20:43:28 | 56.73630825 | -53.0908423 | 224.70 | 3434.7039 | 2023-12-01T21:13:17 | 56.69722050 | -53.0949302 | 174.99 | 3436.0161 | 2023-12-01T20:43:28 | 56.73630825 | -53.0908423 | -3434.7039 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0084_20231201_211350_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0084_20231201_211350_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 4656.6 | 5.0782 | 220 | 2023-12-01T21:13:34 | 56.69634635 | -53.0948862 | 175.61 | 3434.7732 | 2023-12-01T21:43:18 | 56.65457805 | -53.0947273 | 175.82 | 3430.7339 | 2023-12-01T21:13:34 | 56.69634635 | -53.0948862 | -3434.7732 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0085_20231201_214350_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0085_20231201_214350_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.712 | 4388.2 | 4.7896 | 228 | 2023-12-01T21:43:34 | 56.65374135 | -53.0947345 | 177.32 | 3432.0894 | 2023-12-01T22:13:17 | 56.61438300 | -53.0948752 | 173.43 | 3434.5498 | 2023-12-01T21:43:34 | 56.65374135 | -53.0947345 | -3432.0894 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0086_20231201_221347_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0086_20231201_221347_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.550 | 4598.3 | 5.0466 | 218 | 2023-12-01T22:13:31 | 56.61371690 | -53.0948385 | 173.43 | 3436.1765 | 2023-12-01T22:43:04 | 56.57245030 | -53.0949770 | 172.07 | 3442.4985 | 2023-12-01T22:13:31 | 56.61371690 | -53.0948385 | -3436.1765 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0087_20231201_224337_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0087_20231201_224337_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.718 | 4446.9 | 4.8532 | 226 | 2023-12-01T22:43:21 | 56.57162315 | -53.0949283 | 172.13 | 3441.1001 | 2023-12-01T23:13:04 | 56.53173280 | -53.0949454 | 174.76 | 3427.4380 | 2023-12-01T22:43:21 | 56.57162315 | -53.0949283 | -3441.1001 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0088_20231201_231337_MerianEM122.all | application/octet-stream | 21 MBytes | 0088_20231201_231337_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 4334.2 | 4.6916 | 225 | 2023-12-01T23:13:20 | 56.53098250 | -53.0949300 | 174.07 | 3429.7449 | 2023-12-01T23:43:18 | 56.49210165 | -53.0949567 | 171.40 | 3432.6580 | 2023-12-01T23:13:20 | 56.53098250 | -53.0949300 | -3429.7449 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0089_20231201_234348_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0089_20231201_234348_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.436 | 2816.4 | 3.1029 | 215 | 2023-12-01T23:43:48 | 56.49158455 | -53.0949792 | 169.94 | 3431.3472 | 2023-12-02T00:13:15 | 56.46636775 | -53.0949202 | 173.41 | 3436.6143 | 2023-12-01T23:43:48 | 56.49158455 | -53.0949792 | -3431.3472 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0090_20231202_001346_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0090_20231202_001346_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.640 | 3504.1 | 3.8342 | 223 | 2023-12-02T00:13:30 | 56.46585190 | -53.0949687 | 173.59 | 3438.9561 | 2023-12-02T00:43:09 | 56.43443150 | -53.0945672 | 174.08 | 3445.9893 | 2023-12-02T00:13:30 | 56.46585190 | -53.0949687 | -3438.9561 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0091_20231202_004341_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0091_20231202_004341_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.724 | 3463.1 | 3.7788 | 228 | 2023-12-02T00:43:25 | 56.43383650 | -53.0945891 | 173.52 | 3445.6150 | 2023-12-02T01:13:09 | 56.40277975 | -53.0944536 | 171.24 | 3462.6731 | 2023-12-02T00:43:25 | 56.43383650 | -53.0945891 | -3445.6150 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0092_20231202_011342_MerianEM122.all | application/octet-stream | 21 MBytes | 0092_20231202_011342_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 7195.7 | 7.8120 | 228 | 2023-12-02T01:13:25 | 56.40205730 | -53.0943776 | 170.79 | 3464.6843 | 2023-12-02T01:43:18 | 56.39108150 | -53.1910255 | 269.74 | 3442.6509 | 2023-12-02T01:13:25 | 56.40205730 | -53.0943776 | -3464.6843 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0093_20231202_014349_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0093_20231202_014349_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.724 | 9289.1 | 10.1357 | 217 | 2023-12-02T01:43:34 | 56.39126500 | -53.1936611 | 272.47 | 3441.6790 | 2023-12-02T02:13:17 | 56.40145825 | -53.3428948 | 277.16 | 3397.0276 | 2023-12-02T01:43:34 | 56.39126500 | -53.1936611 | -3441.6790 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0094_20231202_021350_MerianEM122.all | application/octet-stream | 3 MBytes | 0094_20231202_021350_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 4.134 | 1243.9 | 9.7561 | 32 | 2023-12-02T02:13:34 | 56.40176435 | -53.3457505 | 274.44 | 3400.5798 | 2023-12-02T02:17:42 | 56.40343795 | -53.3656620 | 274.62 | 3398.7190 | 2023-12-02T02:13:34 | 56.40176435 | -53.3457505 | -3400.5798 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0095_20231202_041646_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0095_20231202_041646_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.472 | 9088.3 | 10.0019 | 220 | 2023-12-02T04:16:37 | 56.40072860 | -53.5330942 | 118.33 | 3353.8694 | 2023-12-02T04:46:05 | 56.40010200 | -53.3861190 | 93.32 | 3386.8049 | 2023-12-02T04:16:37 | 56.40072860 | -53.5330942 | -3353.8694 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0096_20231202_044638_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0096_20231202_044638_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 9468.2 | 10.3239 | 221 | 2023-12-02T04:46:21 | 56.40009485 | -53.3833476 | 92.31 | 3386.9041 | 2023-12-02T05:16:06 | 56.40000380 | -53.2300543 | 90.26 | 3423.9800 | 2023-12-02T04:46:21 | 56.40009485 | -53.3833476 | -3386.9041 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0097_20231202_051639_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0097_20231202_051639_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.862 | 9656.5 | 10.4874 | 221 | 2023-12-02T05:16:23 | 56.40006415 | -53.2271352 | 89.79 | 3431.5674 | 2023-12-02T05:46:14 | 56.40016810 | -53.0707939 | 92.08 | 3469.3005 | 2023-12-02T05:16:23 | 56.40006415 | -53.2271352 | -3431.5674 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0098_20231202_054647_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0098_20231202_054647_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 9523.5 | 10.4005 | 220 | 2023-12-02T05:46:30 | 56.40016775 | -53.0680886 | 94.38 | 3471.2515 | 2023-12-02T06:16:12 | 56.40013780 | -52.9138809 | 92.28 | 3494.2268 | 2023-12-02T05:46:30 | 56.40016775 | -53.0680886 | -3471.2515 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0099_20231202_061645_MerianEM122.all | application/octet-stream | 15.2 MBytes | 0099_20231202_061645_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 21.450 | 6415.7 | 9.7017 | 162 | 2023-12-02T06:16:28 | 56.40014080 | -52.9109533 | 92.38 | 3494.4670 | 2023-12-02T06:37:55 | 56.40266610 | -52.8085613 | 51.41 | 3504.4019 | 2023-12-02T06:16:28 | 56.40014080 | -52.9109533 | -3494.4670 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0100_20231202_073024_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0100_20231202_073024_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.640 | 9202.9 | 10.0691 | 216 | 2023-12-02T07:30:07 | 56.43278635 | -52.7860433 | 359.18 | 3497.5972 | 2023-12-02T07:59:46 | 56.51541445 | -52.7877753 | 358.80 | 3477.7483 | 2023-12-02T07:30:07 | 56.43278635 | -52.7860433 | -3497.5972 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0101_20231202_080019_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0101_20231202_080019_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 9269.7 | 10.0282 | 220 | 2023-12-02T08:00:02 | 56.51700145 | -52.7877967 | 0.63 | 3479.3240 | 2023-12-02T08:30:01 | 56.60022915 | -52.7878320 | 358.63 | 3472.1313 | 2023-12-02T08:00:02 | 56.51700145 | -52.7877967 | -3479.3240 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0102_20231202_083034_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0102_20231202_083034_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.628 | 9026.2 | 9.8809 | 217 | 2023-12-02T08:30:17 | 56.60174720 | -52.7878550 | 359.72 | 3472.4304 | 2023-12-02T08:59:55 | 56.68278085 | -52.7880268 | 1.25 | 3465.2183 | 2023-12-02T08:30:17 | 56.60174720 | -52.7878550 | -3472.4304 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0103_20231202_090026_MerianEM122.all | application/octet-stream | 16.3 MBytes | 0103_20231202_090026_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 23.112 | 6168.8 | 8.6557 | 176 | 2023-12-02T09:00:11 | 56.68423515 | -52.7879285 | 0.77 | 3466.7275 | 2023-12-02T09:23:18 | 56.73895415 | -52.7863957 | 119.00 | 3479.9768 | 2023-12-02T09:00:11 | 56.68423515 | -52.7879285 | -3466.7275 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0104_20231203_131622_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0104_20231203_131622_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.634 | 3792.9 | 4.1513 | 217 | 2023-12-03T13:16:07 | 56.38119885 | -52.8029779 | 8.89 | 3510.0076 | 2023-12-03T13:45:45 | 56.41315655 | -52.8063346 | 314.71 | 3499.9763 | 2023-12-03T13:16:07 | 56.38119885 | -52.8029779 | -3510.0076 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0105_20231203_134617_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0105_20231203_134617_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.658 | 4489.5 | 4.9095 | 216 | 2023-12-03T13:46:01 | 56.41372255 | -52.8073257 | 313.75 | 3499.1455 | 2023-12-03T14:15:41 | 56.43290200 | -52.8664188 | 266.27 | 3495.6890 | 2023-12-03T13:46:01 | 56.41372255 | -52.8073257 | -3499.1455 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0106_20231203_141614_MerianEM122.all | application/octet-stream | 21 MBytes | 0106_20231203_141614_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.958 | 4634.8 | 5.0178 | 223 | 2023-12-03T14:15:57 | 56.43289395 | -52.8677834 | 266.00 | 3496.3928 | 2023-12-03T14:45:55 | 56.43118450 | -52.9381647 | 357.41 | 3492.0237 | 2023-12-03T14:15:57 | 56.43289395 | -52.8677834 | -3496.3928 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0107_20231203_144623_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0107_20231203_144623_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 4196.4 | 4.5756 | 219 | 2023-12-03T14:46:09 | 56.43171230 | -52.9382077 | 19.75 | 3481.7998 | 2023-12-03T15:15:54 | 56.43964310 | -52.8748896 | 85.39 | 3490.8523 | 2023-12-03T14:46:09 | 56.43171230 | -52.9382077 | -3481.7998 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0108_20231203_151627_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0108_20231203_151627_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.562 | 787.7 | 0.8643 | 223 | 2023-12-03T15:16:10 | 56.43965860 | -52.8739676 | 85.49 | 3494.5393 | 2023-12-03T15:45:44 | 56.43942970 | -52.8646929 | 100.94 | 3491.0920 | 2023-12-03T15:16:10 | 56.43965860 | -52.8739676 | -3494.5393 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0109_20231203_154614_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0109_20231203_154614_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.868 | 3626.5 | 3.9379 | 228 | 2023-12-03T15:45:59 | 56.43941285 | -52.8645712 | 94.49 | 3491.1226 | 2023-12-03T16:15:51 | 56.44191105 | -52.8071514 | 31.89 | 3500.5457 | 2023-12-03T15:45:59 | 56.43941285 | -52.8645712 | -3491.1226 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0110_20231203_161620_MerianEM122.all | application/octet-stream | 21 MBytes | 0110_20231203_161620_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 4461.6 | 4.8583 | 223 | 2023-12-03T16:16:06 | 56.44252310 | -52.8065007 | 22.37 | 3501.2373 | 2023-12-03T16:45:53 | 56.44925700 | -52.8689410 | 271.82 | 3482.3457 | 2023-12-03T16:16:06 | 56.44252310 | -52.8065007 | -3501.2373 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0111_20231203_164626_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0111_20231203_164626_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.598 | 4269.0 | 4.6775 | 217 | 2023-12-03T16:46:09 | 56.44928375 | -52.8702562 | 272.08 | 3482.6245 | 2023-12-03T17:15:45 | 56.44701045 | -52.9379563 | 216.97 | 3470.4487 | 2023-12-03T16:46:09 | 56.44928375 | -52.8702562 | -3482.6245 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0112_20231203_171618_MerianEM122.all | application/octet-stream | 21 MBytes | 0112_20231203_171618_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 4467.3 | 4.8629 | 226 | 2023-12-03T17:16:02 | 56.44652700 | -52.9387586 | 220.72 | 3469.7651 | 2023-12-03T17:45:49 | 56.45463340 | -52.9563749 | 71.78 | 3465.2139 | 2023-12-03T17:16:02 | 56.44652700 | -52.9387586 | -3469.7651 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0113_20231203_174623_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0113_20231203_174623_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.622 | 4316.2 | 4.7260 | 215 | 2023-12-03T17:46:06 | 56.45488555 | -52.9551396 | 71.53 | 3463.9851 | 2023-12-03T18:15:43 | 56.45824600 | -52.8861421 | 86.90 | 3478.9707 | 2023-12-03T17:46:06 | 56.45488555 | -52.9551396 | -3463.9851 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0114_20231203_181616_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0114_20231203_181616_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.910 | 4344.8 | 4.7112 | 218 | 2023-12-03T18:16:00 | 56.45825580 | -52.8848493 | 86.67 | 3481.6179 | 2023-12-03T18:45:54 | 56.45825695 | -52.8144130 | 88.41 | 3489.3074 | 2023-12-03T18:16:00 | 56.45825580 | -52.8848493 | -3481.6179 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0115_20231203_184627_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0115_20231203_184627_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.526 | 4264.9 | 4.6848 | 224 | 2023-12-03T18:46:10 | 56.45827075 | -52.8131033 | 88.52 | 3490.3962 | 2023-12-03T19:15:42 | 56.46779060 | -52.8440278 | 264.15 | 3480.1116 | 2023-12-03T18:46:10 | 56.45827075 | -52.8131033 | -3490.3962 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0116_20231203_191614_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0116_20231203_191614_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.826 | 4211.2 | 4.5795 | 215 | 2023-12-03T19:15:58 | 56.46776380 | -52.8452834 | 262.85 | 3482.7036 | 2023-12-03T19:45:48 | 56.46773885 | -52.9135531 | 268.05 | 3467.3279 | 2023-12-03T19:15:58 | 56.46776380 | -52.8452834 | -3482.7036 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0117_20231203_194621_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0117_20231203_194621_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.658 | 4159.5 | 4.5488 | 224 | 2023-12-03T19:46:04 | 56.46775350 | -52.9148714 | 266.91 | 3464.9871 | 2023-12-03T20:15:44 | 56.47700375 | -52.8830200 | 88.03 | 3479.1804 | 2023-12-03T19:46:04 | 56.46775350 | -52.9148714 | -3464.9871 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0118_20231203_201617_MerianEM122.all | application/octet-stream | 21 MBytes | 0118_20231203_201617_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.886 | 4139.6 | 4.4924 | 221 | 2023-12-03T20:16:00 | 56.47698525 | -52.8817010 | 88.42 | 3473.2695 | 2023-12-03T20:45:53 | 56.48357865 | -52.8229851 | 331.11 | 3480.4717 | 2023-12-03T20:16:00 | 56.47698525 | -52.8817010 | -3473.2695 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0119_20231203_204623_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0119_20231203_204623_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.658 | 4355.6 | 4.7633 | 217 | 2023-12-03T20:46:08 | 56.48415950 | -52.8234335 | 322.81 | 3480.1541 | 2023-12-03T21:15:47 | 56.48641570 | -52.8924779 | 269.74 | 3466.5344 | 2023-12-03T20:46:08 | 56.48415950 | -52.8234335 | -3480.1541 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0120_20231203_211620_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0120_20231203_211620_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 4124.3 | 4.4895 | 228 | 2023-12-03T21:16:04 | 56.48643910 | -52.8937565 | 269.07 | 3467.0571 | 2023-12-03T21:45:51 | 56.49573380 | -52.8934019 | 87.69 | 3462.8906 | 2023-12-03T21:16:04 | 56.48643910 | -52.8937565 | -3467.0571 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0121_20231203_214624_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0121_20231203_214624_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.712 | 4378.3 | 4.7790 | 214 | 2023-12-03T21:46:07 | 56.49576705 | -52.8921096 | 88.80 | 3467.3931 | 2023-12-03T22:15:50 | 56.49576220 | -52.8210444 | 92.94 | 3475.6960 | 2023-12-03T21:46:07 | 56.49576705 | -52.8921096 | -3467.3931 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0122_20231203_221623_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0122_20231203_221623_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.670 | 4485.5 | 4.9032 | 232 | 2023-12-03T22:16:07 | 56.49576160 | -52.8196905 | 92.74 | 3474.1948 | 2023-12-03T22:45:47 | 56.49164390 | -52.8148870 | 264.66 | 3475.9553 | 2023-12-03T22:16:07 | 56.49576160 | -52.8196905 | -3474.1948 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0123_20231203_224620_MerianEM122.all | application/octet-stream | 16.5 MBytes | 0123_20231203_224620_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 23.478 | 3217.9 | 4.4447 | 174 | 2023-12-03T22:46:03 | 56.49163405 | -52.8161305 | 264.27 | 3476.4768 | 2023-12-03T23:09:32 | 56.49139640 | -52.8683009 | 286.52 | 3475.7195 | 2023-12-03T22:46:03 | 56.49163405 | -52.8161305 | -3476.4768 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0124_20231204_014841_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0124_20231204_014841_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.694 | 4912.2 | 5.3651 | 227 | 2023-12-04T01:48:25 | 56.51379440 | -52.8464357 | 357.04 | 3469.6094 | 2023-12-04T02:18:06 | 56.54451380 | -52.8602207 | 89.11 | 3472.8154 | 2023-12-04T01:48:25 | 56.51379440 | -52.8464357 | -3469.6094 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0125_20231204_021839_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0125_20231204_021839_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.604 | 4997.4 | 5.4749 | 218 | 2023-12-04T02:18:22 | 56.54451825 | -52.8586740 | 85.47 | 3474.4255 | 2023-12-04T02:47:59 | 56.51821595 | -52.8237155 | 194.87 | 3477.9180 | 2023-12-04T02:18:22 | 56.54451825 | -52.8586740 | -3474.4255 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0126_20231204_024831_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0126_20231204_024831_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.910 | 4121.9 | 4.4697 | 231 | 2023-12-04T02:48:15 | 56.51751535 | -52.8241141 | 215.32 | 3474.7588 | 2023-12-04T03:18:10 | 56.54879885 | -52.8333952 | 336.07 | 3477.5891 | 2023-12-04T02:48:15 | 56.51751535 | -52.8241141 | -3474.7588 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0127_20231204_031842_MerianEM122.all | application/octet-stream | 12.6 MBytes | 0127_20231204_031842_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 17.676 | 1260.6 | 2.3129 | 143 | 2023-12-04T03:18:26 | 56.54942235 | -52.8339031 | 317.01 | 3476.3994 | 2023-12-04T03:36:07 | 56.54300325 | -52.8391351 | 201.74 | 3473.7603 | 2023-12-04T03:18:26 | 56.54942235 | -52.8339031 | -3476.3994 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0128_20231204_182602_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0128_20231204_182602_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.922 | 4486.8 | 4.8631 | 247 | 2023-12-04T18:25:46 | 56.57310095 | -52.8010789 | 90.73 | 3477.5754 | 2023-12-04T18:55:41 | 56.60042610 | -52.7981289 | 269.62 | 3476.0146 | 2023-12-04T18:25:46 | 56.57310095 | -52.8010789 | -3477.5754 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0129_20231204_185608_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0129_20231204_185608_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.844 | 4292.0 | 4.6642 | 237 | 2023-12-04T18:55:54 | 56.60044875 | -52.7992088 | 269.00 | 3473.4399 | 2023-12-04T19:25:45 | 56.59154800 | -52.8515524 | 102.31 | 3462.2065 | 2023-12-04T18:55:54 | 56.60044875 | -52.7992088 | -3473.4399 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0130_20231204_192605_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0130_20231204_192605_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.706 | 4170.4 | 4.5532 | 243 | 2023-12-04T19:25:55 | 56.59143460 | -52.8509734 | 95.21 | 3466.5645 | 2023-12-04T19:55:38 | 56.59134475 | -52.7831646 | 88.20 | 3474.2092 | 2023-12-04T19:25:55 | 56.59143460 | -52.8509734 | -3466.5645 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0131_20231204_195605_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0131_20231204_195605_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.898 | 3964.0 | 4.3000 | 285 | 2023-12-04T19:55:51 | 56.59136325 | -52.7821129 | 88.10 | 3474.7852 | 2023-12-04T20:25:45 | 56.61771395 | -52.7642857 | 324.75 | 3472.2231 | 2023-12-04T19:55:51 | 56.59136325 | -52.7821129 | -3474.7852 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0132_20231204_202604_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0132_20231204_202604_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.748 | 4437.5 | 4.8379 | 239 | 2023-12-04T20:25:54 | 56.61798035 | -52.7646905 | 313.22 | 3470.8521 | 2023-12-04T20:55:39 | 56.61841450 | -52.8366075 | 267.75 | 3469.3230 | 2023-12-04T20:25:54 | 56.61798035 | -52.7646905 | -3470.8521 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0133_20231204_205609_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0133_20231204_205609_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.868 | 4202.5 | 4.5633 | 256 | 2023-12-04T20:55:54 | 56.61842260 | -52.8377909 | 270.82 | 3468.7844 | 2023-12-04T21:25:46 | 56.60941820 | -52.8828945 | 91.93 | 3472.2622 | 2023-12-04T20:55:54 | 56.61842260 | -52.8377909 | -3468.7844 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0134_20231204_212610_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0134_20231204_212610_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 2963.5 | 3.2270 | 260 | 2023-12-04T21:25:58 | 56.60939800 | -52.8821121 | 89.24 | 3464.6694 | 2023-12-04T21:55:45 | 56.61022075 | -52.8339581 | 88.81 | 3468.2559 | 2023-12-04T21:25:58 | 56.60939800 | -52.8821121 | -3464.6694 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0135_20231204_215612_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0135_20231204_215612_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 825.6 | 0.9021 | 230 | 2023-12-04T21:55:58 | 56.61023965 | -52.8332480 | 89.90 | 3467.3142 | 2023-12-04T22:25:39 | 56.61129180 | -52.8235471 | 90.83 | 3470.0933 | 2023-12-04T21:55:58 | 56.61023965 | -52.8332480 | -3467.3142 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0136_20231204_222610_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0136_20231204_222610_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 28.542 | 747.6 | 0.8495 | 219 | 2023-12-04T22:25:55 | 56.61130625 | -52.8235296 | 89.24 | 3471.0745 | 2023-12-04T22:54:27 | 56.61179645 | -52.8133984 | 81.45 | 3471.0015 | 2023-12-04T22:25:55 | 56.61130625 | -52.8235296 | -3471.0745 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0137_20231205_032029_MerianEM122.all | application/octet-stream | 18.3 MBytes | 0137_20231205_032029_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.514 | 4198.8 | 4.6136 | 206 | 2023-12-05T03:20:29 | 56.65703785 | -52.7303329 | 267.09 | 3481.5386 | 2023-12-05T03:50:00 | 56.65697020 | -52.7986907 | 266.34 | 3472.3357 | 2023-12-05T03:20:29 | 56.65703785 | -52.7303329 | -3481.5386 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0138_20231205_035022_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0138_20231205_035022_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.772 | 4254.4 | 4.6346 | 261 | 2023-12-05T03:50:22 | 56.65700345 | -52.7995432 | 268.35 | 3469.5283 | 2023-12-05T04:20:09 | 56.65628935 | -52.8687359 | 261.10 | 3467.0088 | 2023-12-05T03:50:22 | 56.65700345 | -52.7995432 | -3469.5283 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0139_20231205_042027_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0139_20231205_042027_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.502 | 4088.5 | 4.4948 | 272 | 2023-12-05T04:20:27 | 56.65627330 | -52.8694646 | 261.65 | 3469.2285 | 2023-12-05T04:49:57 | 56.64607270 | -52.9030723 | 89.12 | 3459.8730 | 2023-12-05T04:20:27 | 56.65627330 | -52.8694646 | -3469.2285 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0140_20231205_045020_MerianEM122.all | application/octet-stream | 21.6 MBytes | 0140_20231205_045020_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.916 | 3868.2 | 4.1933 | 281 | 2023-12-05T04:50:08 | 56.64607450 | -52.9022599 | 91.30 | 3456.5920 | 2023-12-05T05:20:03 | 56.64585945 | -52.8393463 | 85.39 | 3468.4507 | 2023-12-05T04:50:08 | 56.64607450 | -52.9022599 | -3456.5920 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0141_20231205_052027_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0141_20231205_052027_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.778 | 3873.6 | 4.2193 | 268 | 2023-12-05T05:20:15 | 56.64586495 | -52.8386339 | 86.17 | 3466.9639 | 2023-12-05T05:50:01 | 56.64596780 | -52.7756781 | 84.13 | 3470.6772 | 2023-12-05T05:20:15 | 56.64586495 | -52.8386339 | -3466.9639 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0142_20231205_055022_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0142_20231205_055022_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 3940.9 | 4.2822 | 269 | 2023-12-05T05:50:11 | 56.64601760 | -52.7749279 | 82.73 | 3470.1709 | 2023-12-05T06:20:02 | 56.65686140 | -52.7192690 | 51.08 | 3495.5068 | 2023-12-05T05:50:11 | 56.64601760 | -52.7749279 | -3470.1709 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0143_20231205_062020_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0143_20231205_062020_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 4247.4 | 4.6313 | 255 | 2023-12-05T06:20:12 | 56.65711800 | -52.7188779 | 50.60 | 3492.2961 | 2023-12-05T06:49:56 | 56.67493885 | -52.7313562 | 285.11 | 3487.0249 | 2023-12-05T06:20:12 | 56.65711800 | -52.7188779 | -3492.2961 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0144_20231205_065021_MerianEM122.all | application/octet-stream | 19.4 MBytes | 0144_20231205_065021_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 4522.2 | 4.9137 | 237 | 2023-12-05T06:50:09 | 56.67504580 | -52.7323077 | 282.72 | 3490.1113 | 2023-12-05T07:19:59 | 56.67363400 | -52.8058562 | 280.23 | 3480.5586 | 2023-12-05T06:50:09 | 56.67504580 | -52.7323077 | -3490.1113 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0145_20231205_072023_MerianEM122.all | application/octet-stream | 17.9 MBytes | 0145_20231205_072023_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.496 | 4304.4 | 4.7327 | 197 | 2023-12-05T07:20:40 | 56.67369790 | -52.8074504 | 278.82 | 3463.7947 | 2023-12-05T07:50:10 | 56.67416365 | -52.8775292 | 272.52 | 3457.4207 | 2023-12-05T07:20:40 | 56.67369790 | -52.8074504 | -3463.7947 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0146_20231205_075027_MerianEM122.all | application/octet-stream | 19 MBytes | 0146_20231205_075027_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.256 | 3977.2 | 4.4091 | 220 | 2023-12-05T07:50:52 | 56.67420270 | -52.8791562 | 270.08 | 3471.2830 | 2023-12-05T08:20:08 | 56.66178050 | -52.9030762 | 86.54 | 3460.1753 | 2023-12-05T07:50:52 | 56.67420270 | -52.8791562 | -3471.2830 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0147_20231205_082029_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0147_20231205_082029_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.628 | 4275.1 | 4.6796 | 267 | 2023-12-05T08:20:18 | 56.66176780 | -52.9021331 | 86.80 | 3466.9355 | 2023-12-05T08:49:56 | 56.66160140 | -52.8325315 | 84.41 | 3466.7549 | 2023-12-05T08:20:18 | 56.66176780 | -52.9021331 | -3466.9355 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0148_20231205_085020_MerianEM122.all | application/octet-stream | 22.1 MBytes | 0148_20231205_085020_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.946 | 4563.4 | 4.9419 | 284 | 2023-12-05T08:50:08 | 56.66159990 | -52.8315475 | 85.61 | 3465.2336 | 2023-12-05T09:20:05 | 56.66185225 | -52.7572565 | 85.63 | 3474.0906 | 2023-12-05T08:50:08 | 56.66159990 | -52.8315475 | -3465.2336 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0149_20231205_092028_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0149_20231205_092028_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 4391.4 | 4.7700 | 283 | 2023-12-05T09:20:16 | 56.66182180 | -52.7562122 | 87.69 | 3478.3005 | 2023-12-05T09:50:08 | 56.67161590 | -52.7705631 | 245.72 | 3469.1709 | 2023-12-05T09:20:16 | 56.66182180 | -52.7562122 | -3478.3005 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0150_20231205_095025_MerianEM122.all | application/octet-stream | 9.6 MBytes | 0150_20231205_095025_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 13.584 | 1963.3 | 4.6881 | 112 | 2023-12-05T09:50:16 | 56.67146550 | -52.7712614 | 245.40 | 3465.9497 | 2023-12-05T10:03:51 | 56.66375540 | -52.8000345 | 239.97 | 3467.8271 | 2023-12-05T09:50:16 | 56.67146550 | -52.7712614 | -3465.9497 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0151_20231205_160018_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0151_20231205_160018_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 4556.3 | 4.9500 | 292 | 2023-12-05T16:00:04 | 56.68145520 | -52.7076588 | 69.31 | 3494.0129 | 2023-12-05T16:29:55 | 56.71002615 | -52.6585957 | 38.18 | 3502.8936 | 2023-12-05T16:00:04 | 56.68145520 | -52.7076588 | -3494.0129 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0152_20231205_163014_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0152_20231205_163014_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.472 | 4409.3 | 4.8519 | 242 | 2023-12-05T16:30:05 | 56.71042850 | -52.6582538 | 38.53 | 3503.1743 | 2023-12-05T16:59:33 | 56.71122850 | -52.6946823 | 245.35 | 3496.5635 | 2023-12-05T16:30:05 | 56.71042850 | -52.6582538 | -3503.1743 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0153_20231205_170021_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0153_20231205_170021_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.838 | 4393.2 | 4.7756 | 220 | 2023-12-05T17:00:06 | 56.71088580 | -52.6964967 | 240.79 | 3490.6062 | 2023-12-05T17:29:56 | 56.69708555 | -52.7636226 | 241.49 | 3484.9666 | 2023-12-05T17:00:06 | 56.71088580 | -52.6964967 | -3490.6062 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0154_20231205_173024_MerianEM122.all | application/octet-stream | 21 MBytes | 0154_20231205_173024_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 4205.0 | 4.5922 | 240 | 2023-12-05T17:30:10 | 56.69685175 | -52.7646206 | 240.34 | 3483.6658 | 2023-12-05T17:59:51 | 56.69869545 | -52.7967103 | 44.27 | 3474.8074 | 2023-12-05T17:30:10 | 56.69685175 | -52.7646206 | -3483.6658 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0155_20231205_180020_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0155_20231205_180020_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.616 | 4439.1 | 4.8609 | 238 | 2023-12-05T18:00:06 | 56.69926100 | -52.7958773 | 43.91 | 3474.2043 | 2023-12-05T18:29:43 | 56.72079805 | -52.7383643 | 71.08 | 3486.9109 | 2023-12-05T18:00:06 | 56.69926100 | -52.7958773 | -3474.2043 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0156_20231205_183015_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0156_20231205_183015_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 4399.9 | 4.8049 | 231 | 2023-12-05T18:29:59 | 56.72103505 | -52.7371514 | 69.25 | 3485.0371 | 2023-12-05T18:59:41 | 56.73452445 | -52.6696468 | 68.02 | 3496.6409 | 2023-12-05T18:29:59 | 56.72103505 | -52.7371514 | -3485.0371 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0157_20231205_190013_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0157_20231205_190013_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.958 | 4077.3 | 4.4143 | 245 | 2023-12-05T18:59:57 | 56.73479630 | -52.6683928 | 69.59 | 3497.9365 | 2023-12-05T19:29:55 | 56.76161905 | -52.6295910 | 244.38 | 3499.7400 | 2023-12-05T18:59:57 | 56.73479630 | -52.6683928 | -3497.9365 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0158_20231205_193013_MerianEM122.all | application/octet-stream | 21 MBytes | 0158_20231205_193013_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.838 | 4357.3 | 4.7366 | 232 | 2023-12-05T19:30:04 | 56.76149870 | -52.6301835 | 244.75 | 3736.7151 | 2023-12-05T19:59:54 | 56.74770695 | -52.6968256 | 248.05 | 3493.4163 | 2023-12-05T19:30:04 | 56.76149870 | -52.6301835 | -3736.7151 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0159_20231205_200027_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0159_20231205_200027_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.514 | 4155.5 | 4.5669 | 214 | 2023-12-05T20:00:10 | 56.74742510 | -52.6981088 | 252.10 | 3488.7654 | 2023-12-05T20:29:41 | 56.73402865 | -52.7614670 | 246.32 | 3479.7302 | 2023-12-05T20:00:10 | 56.74742510 | -52.6981088 | -3488.7654 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0160_20231205_203014_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0160_20231205_203014_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.886 | 4572.8 | 4.9620 | 231 | 2023-12-05T20:29:57 | 56.73374510 | -52.7626321 | 248.64 | 3479.5427 | 2023-12-05T20:59:50 | 56.72846805 | -52.8151721 | 39.00 | 3470.2935 | 2023-12-05T20:29:57 | 56.73374510 | -52.7626321 | -3479.5427 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0161_20231205_210019_MerianEM122.all | application/octet-stream | 21 MBytes | 0161_20231205_210019_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.808 | 6394.7 | 6.9573 | 223 | 2023-12-05T21:00:05 | 56.72917930 | -52.8140576 | 39.25 | 3473.0022 | 2023-12-05T21:29:53 | 56.75888255 | -52.7285651 | 64.29 | 3485.0007 | 2023-12-05T21:00:05 | 56.72917930 | -52.8140576 | -3473.0022 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0162_20231205_213026_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0162_20231205_213026_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 6335.8 | 6.9089 | 219 | 2023-12-05T21:30:09 | 56.75924880 | -52.7266967 | 65.15 | 3485.4097 | 2023-12-05T21:59:54 | 56.77854840 | -52.6292442 | 63.65 | 3497.5325 | 2023-12-05T21:30:09 | 56.75924880 | -52.7266967 | -3485.4097 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0163_20231205_220026_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0163_20231205_220026_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.646 | 5969.3 | 6.5307 | 224 | 2023-12-05T22:00:10 | 56.77895725 | -52.6273689 | 63.88 | 3498.8250 | 2023-12-05T22:29:48 | 56.79120255 | -52.6188714 | 256.39 | 3498.4297 | 2023-12-05T22:00:10 | 56.77895725 | -52.6273689 | -3498.8250 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0164_20231205_223021_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0164_20231205_223021_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.886 | 2929.3 | 3.1789 | 242 | 2023-12-05T22:30:04 | 56.79101490 | -52.6198496 | 258.41 | 3497.0645 | 2023-12-05T22:59:57 | 56.78182620 | -52.6647370 | 259.45 | 3488.1011 | 2023-12-05T22:30:04 | 56.79101490 | -52.6198496 | -3497.0645 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0165_20231205_230028_MerianEM122.all | application/octet-stream | 6.4 MBytes | 0165_20231205_230028_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 8.880 | 667.2 | 2.4364 | 74 | 2023-12-05T23:00:12 | 56.78168050 | -52.6655176 | 259.85 | 3492.0881 | 2023-12-05T23:09:05 | 56.77947330 | -52.6753163 | 52.59 | 3496.0625 | 2023-12-05T23:00:12 | 56.78168050 | -52.6655176 | -3492.0881 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0166_20231206_010142_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0166_20231206_010142_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.766 | 5673.8 | 6.1821 | 217 | 2023-12-06T01:01:25 | 56.77945310 | -52.6908844 | 251.01 | 3489.1750 | 2023-12-06T01:31:11 | 56.76199470 | -52.7780357 | 257.54 | 3474.5925 | 2023-12-06T01:01:25 | 56.77945310 | -52.6908844 | -3489.1750 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0167_20231206_013140_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0167_20231206_013140_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.052 | 1029.1 | 1.1489 | 217 | 2023-12-06T01:32:07 | 56.76186570 | -52.7783296 | 259.29 | 3475.2668 | 2023-12-06T02:01:10 | 56.75492665 | -52.7885994 | 247.36 | 3474.4172 | 2023-12-06T01:32:07 | 56.76186570 | -52.7783296 | -3475.2668 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0168_20231206_020143_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0168_20231206_020143_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.766 | 1314.0 | 1.4317 | 248 | 2023-12-06T02:01:26 | 56.75482165 | -52.7886321 | 248.03 | 3478.9893 | 2023-12-06T02:31:12 | 56.74893105 | -52.8002472 | 56.55 | 3473.9956 | 2023-12-06T02:01:26 | 56.75482165 | -52.7886321 | -3478.9893 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0169_20231206_023141_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0169_20231206_023141_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.808 | 1296.1 | 1.4103 | 237 | 2023-12-06T02:31:27 | 56.74877380 | -52.8004496 | 57.27 | 3473.9944 | 2023-12-06T03:01:15 | 56.74345810 | -52.8060462 | 43.35 | 3474.9497 | 2023-12-06T02:31:27 | 56.74877380 | -52.8004496 | -3473.9944 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0170_20231206_030145_MerianEM122.all | application/octet-stream | 21 MBytes | 0170_20231206_030145_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.802 | 6085.9 | 6.6231 | 227 | 2023-12-06T03:01:30 | 56.74396105 | -52.8050760 | 42.49 | 3477.9324 | 2023-12-06T03:31:18 | 56.78023960 | -52.7323399 | 54.58 | 3485.9729 | 2023-12-06T03:01:30 | 56.74396105 | -52.8050760 | -3477.9324 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0171_20231206_033142_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0171_20231206_033142_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.652 | 3407.1 | 3.7264 | 252 | 2023-12-06T03:31:31 | 56.78023745 | -52.7321132 | 53.98 | 3493.5808 | 2023-12-06T04:01:10 | 56.79027080 | -52.6796161 | 63.53 | 3490.0613 | 2023-12-06T03:31:31 | 56.78023745 | -52.7321132 | -3493.5808 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0172_20231206_040138_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0172_20231206_040138_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.688 | 3557.4 | 3.8864 | 243 | 2023-12-06T04:01:24 | 56.79043075 | -52.6787725 | 62.34 | 3495.4817 | 2023-12-06T04:31:05 | 56.80136505 | -52.6241000 | 67.36 | 3495.5977 | 2023-12-06T04:01:24 | 56.79043075 | -52.6787725 | -3495.4817 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0173_20231206_043138_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0173_20231206_043138_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 3985.3 | 4.3383 | 230 | 2023-12-06T04:31:22 | 56.80157705 | -52.6229795 | 66.61 | 3497.8533 | 2023-12-06T05:01:09 | 56.82258930 | -52.5741680 | 30.22 | 3498.4341 | 2023-12-06T04:31:22 | 56.80157705 | -52.6229795 | -3497.8533 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0174_20231206_050138_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0174_20231206_050138_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.820 | 3763.9 | 4.0939 | 248 | 2023-12-06T05:01:23 | 56.82296595 | -52.5736008 | 29.01 | 3498.5852 | 2023-12-06T05:31:12 | 56.82283735 | -52.6164185 | 256.30 | 3495.4250 | 2023-12-06T05:01:23 | 56.82296595 | -52.5736008 | -3498.5852 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0175_20231206_053144_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0175_20231206_053144_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.688 | 4159.6 | 4.5445 | 225 | 2023-12-06T05:31:28 | 56.82265900 | -52.6175505 | 255.07 | 3494.7810 | 2023-12-06T06:01:09 | 56.81024930 | -52.6817566 | 249.52 | 3490.2380 | 2023-12-06T05:31:28 | 56.82265900 | -52.6175505 | -3494.7810 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0176_20231206_060143_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0176_20231206_060143_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.886 | 4491.6 | 4.8739 | 218 | 2023-12-06T06:01:26 | 56.80997595 | -52.6830948 | 249.92 | 3487.9111 | 2023-12-06T06:31:19 | 56.79616200 | -52.7521532 | 250.45 | 3473.1873 | 2023-12-06T06:01:26 | 56.80997595 | -52.6830948 | -3487.9111 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0177_20231206_063150_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0177_20231206_063150_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.604 | 4731.8 | 5.1835 | 238 | 2023-12-06T06:31:35 | 56.79592895 | -52.7533382 | 251.92 | 3474.9851 | 2023-12-06T07:01:11 | 56.81509035 | -52.7547538 | 60.70 | 3474.3359 | 2023-12-06T06:31:35 | 56.79592895 | -52.7533382 | -3474.9851 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0178_20231206_070142_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0178_20231206_070142_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.766 | 4611.5 | 5.0244 | 239 | 2023-12-06T07:01:27 | 56.81538230 | -52.7534962 | 64.20 | 3474.0071 | 2023-12-06T07:31:13 | 56.82928495 | -52.6823930 | 61.84 | 3486.5256 | 2023-12-06T07:01:27 | 56.81538230 | -52.7534962 | -3474.0071 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0179_20231206_073141_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0179_20231206_073141_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 5302.5 | 5.7743 | 240 | 2023-12-06T07:31:27 | 56.82949770 | -52.6812822 | 61.64 | 3486.1714 | 2023-12-06T08:01:14 | 56.84570965 | -52.5996248 | 61.23 | 3496.8555 | 2023-12-06T07:31:27 | 56.82949770 | -52.6812822 | -3486.1714 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0180_20231206_080143_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0180_20231206_080143_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 5562.1 | 6.0743 | 242 | 2023-12-06T08:01:29 | 56.84595820 | -52.5982749 | 60.38 | 3497.2886 | 2023-12-06T08:31:11 | 56.84634290 | -52.5148181 | 133.64 | 3498.0049 | 2023-12-06T08:01:29 | 56.84595820 | -52.5982749 | -3497.2886 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0181_20231206_083141_MerianEM122.all | application/octet-stream | 21 MBytes | 0181_20231206_083141_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.670 | 5840.7 | 6.3848 | 225 | 2023-12-06T08:31:26 | 56.84568725 | -52.5136701 | 147.12 | 3500.8206 | 2023-12-06T09:01:06 | 56.79471885 | -52.5326548 | 204.41 | 3503.0962 | 2023-12-06T08:31:26 | 56.84568725 | -52.5136701 | -3500.8206 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0182_20231206_090139_MerianEM122.all | application/octet-stream | 21.9 MBytes | 0182_20231206_090139_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 30.018 | 3623.5 | 3.9150 | 287 | 2023-12-06T09:01:23 | 56.79398640 | -52.5331186 | 204.05 | 3508.6267 | 2023-12-06T09:31:24 | 56.78197325 | -52.5133829 | 55.79 | 3511.3547 | 2023-12-06T09:01:23 | 56.79398640 | -52.5331186 | -3508.6267 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0183_20231206_093144_MerianEM122.all | application/octet-stream | 22.3 MBytes | 0183_20231206_093144_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.670 | 3744.5 | 4.0936 | 324 | 2023-12-06T09:31:34 | 56.78210295 | -52.5126799 | 54.78 | 3508.2742 | 2023-12-06T10:01:14 | 56.78814575 | -52.4718200 | 276.42 | 3509.7954 | 2023-12-06T09:31:34 | 56.78210295 | -52.5126799 | -3508.2742 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0184_20231206_100138_MerianEM122.all | application/octet-stream | 11.6 MBytes | 0184_20231206_100138_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 16.278 | 3984.8 | 7.9386 | 128 | 2023-12-06T10:01:25 | 56.78821260 | -52.4731869 | 276.07 | 3505.3105 | 2023-12-06T10:17:42 | 56.79238680 | -52.5355080 | 341.95 | 3502.3518 | 2023-12-06T10:01:25 | 56.78821260 | -52.4731869 | -3505.3105 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0185_20231206_152425_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0185_20231206_152425_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.826 | 8718.7 | 9.4812 | 234 | 2023-12-06T15:24:09 | 56.76090955 | -52.5364286 | 82.42 | 3506.1118 | 2023-12-06T15:53:59 | 56.75095560 | -52.5032165 | 271.54 | 3506.8484 | 2023-12-06T15:24:09 | 56.76090955 | -52.5364286 | -3506.1118 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0186_20231206_155431_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0186_20231206_155431_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.538 | 8900.4 | 9.7724 | 216 | 2023-12-06T15:54:14 | 56.75098355 | -52.5058688 | 272.19 | 3508.5264 | 2023-12-06T16:23:47 | 56.75110045 | -52.6513374 | 285.58 | 3496.6646 | 2023-12-06T15:54:14 | 56.75098355 | -52.5058688 | -3508.5264 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0187_20231206_162419_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0187_20231206_162419_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.652 | 8378.1 | 9.1629 | 224 | 2023-12-06T16:24:03 | 56.75167545 | -52.6534051 | 328.81 | 3494.6648 | 2023-12-06T16:53:42 | 56.77621755 | -52.5390475 | 84.71 | 3517.9800 | 2023-12-06T16:24:03 | 56.75167545 | -52.6534051 | -3494.6648 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0188_20231206_165415_MerianEM122.all | application/octet-stream | 21 MBytes | 0188_20231206_165415_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 8880.6 | 9.6421 | 221 | 2023-12-06T16:53:58 | 56.77626320 | -52.5363186 | 86.30 | 3504.7820 | 2023-12-06T17:23:50 | 56.79060635 | -52.4031831 | 2.56 | 3513.9014 | 2023-12-06T16:53:58 | 56.77626320 | -52.5363186 | -3504.7820 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0189_20231206_172421_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0189_20231206_172421_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 9173.0 | 9.9778 | 222 | 2023-12-06T17:24:06 | 56.79157275 | -52.4033515 | 307.72 | 3513.5754 | 2023-12-06T17:53:55 | 56.79080945 | -52.5530443 | 269.21 | 3499.2712 | 2023-12-06T17:24:06 | 56.79157275 | -52.4033515 | -3513.5754 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0190_20231206_175428_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0190_20231206_175428_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.724 | 9355.0 | 10.2079 | 217 | 2023-12-06T17:54:12 | 56.79083260 | -52.5559976 | 267.28 | 3502.4514 | 2023-12-06T18:23:55 | 56.79389540 | -52.7013147 | 33.73 | 3488.1152 | 2023-12-06T17:54:12 | 56.79083260 | -52.5559976 | -3502.4514 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0191_20231206_182423_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0191_20231206_182423_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.574 | 9070.9 | 9.9476 | 219 | 2023-12-06T18:24:09 | 56.79469020 | -52.7001748 | 31.94 | 3486.7781 | 2023-12-06T18:53:43 | 56.80013555 | -52.5561698 | 88.68 | 3500.2996 | 2023-12-06T18:24:09 | 56.79469020 | -52.7001748 | -3486.7781 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0192_20231206_185415_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0192_20231206_185415_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 9212.5 | 9.9622 | 225 | 2023-12-06T18:53:59 | 56.80010950 | -52.5533007 | 88.29 | 3504.7429 | 2023-12-06T19:23:59 | 56.80915680 | -52.4121845 | 273.09 | 3507.0872 | 2023-12-06T18:53:59 | 56.80010950 | -52.5533007 | -3504.7429 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0193_20231206_192423_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0193_20231206_192423_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 9074.4 | 9.8962 | 224 | 2023-12-06T19:24:11 | 56.80916510 | -52.4130544 | 257.68 | 3509.7817 | 2023-12-06T19:53:55 | 56.80909030 | -52.5615172 | 268.94 | 3497.1602 | 2023-12-06T19:24:11 | 56.80916510 | -52.4130544 | -3509.7817 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0194_20231206_195428_MerianEM122.all | application/octet-stream | 18.3 MBytes | 0194_20231206_195428_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 26.280 | 8238.2 | 10.1676 | 192 | 2023-12-06T19:54:12 | 56.80908995 | -52.5644463 | 268.88 | 3497.2085 | 2023-12-06T20:20:28 | 56.80916935 | -52.6992910 | 267.07 | 3485.4058 | 2023-12-06T19:54:12 | 56.80908995 | -52.5644463 | -3497.2085 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0195_20231207_052609_MerianEM122.all | application/octet-stream | 22.3 MBytes | 0195_20231207_052609_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.892 | 3748.6 | 4.0672 | 349 | 2023-12-07T05:25:59 | 56.80547615 | -52.4622172 | 47.70 | 3504.9512 | 2023-12-07T05:55:52 | 56.81631095 | -52.4043766 | 52.58 | 3517.3931 | 2023-12-07T05:25:59 | 56.80547615 | -52.4622172 | -3504.9512 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0196_20231207_055609_MerianEM122.all | application/octet-stream | 21.6 MBytes | 0196_20231207_055609_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.844 | 3786.4 | 4.1152 | 338 | 2023-12-07T05:56:00 | 56.81643045 | -52.4037681 | 53.17 | 3525.1941 | 2023-12-07T06:25:51 | 56.82860405 | -52.3827450 | 272.68 | 3515.1877 | 2023-12-07T05:56:00 | 56.81643045 | -52.4037681 | -3525.1941 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0197_20231207_062605_MerianEM122.all | application/octet-stream | 21.6 MBytes | 0197_20231207_062605_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.844 | 3950.4 | 4.2930 | 355 | 2023-12-07T06:25:58 | 56.82853660 | -52.3832371 | 271.03 | 3804.4906 | 2023-12-07T06:55:49 | 56.81940145 | -52.4456840 | 267.68 | 3507.6487 | 2023-12-07T06:25:58 | 56.82853660 | -52.3832371 | -3804.4906 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0198_20231207_065604_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0198_20231207_065604_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 3927.4 | 4.2697 | 334 | 2023-12-07T06:55:57 | 56.81933130 | -52.4462386 | 268.81 | 3506.0405 | 2023-12-07T07:25:47 | 56.80941505 | -52.5076404 | 231.50 | 3503.7566 | 2023-12-07T06:55:57 | 56.81933130 | -52.4462386 | -3506.0405 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0199_20231207_072604_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0199_20231207_072604_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.892 | 4092.9 | 4.4408 | 317 | 2023-12-07T07:25:55 | 56.80916270 | -52.5080874 | 230.10 | 3508.1025 | 2023-12-07T07:55:48 | 56.77864250 | -52.5451634 | 218.25 | 3510.1716 | 2023-12-07T07:25:55 | 56.80916270 | -52.5080874 | -3508.1025 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0200_20231207_075608_MerianEM122.all | application/octet-stream | 11 MBytes | 0200_20231207_075608_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 14.838 | 2457.3 | 5.3716 | 172 | 2023-12-07T07:56:18 | 56.77810995 | -52.5457077 | 205.99 | 3504.2490 | 2023-12-07T08:11:08 | 56.78266320 | -52.5111051 | 62.42 | 3509.0278 | 2023-12-07T07:56:18 | 56.77810995 | -52.5457077 | -3504.2490 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0201_20231207_155538_MerianEM122.all | application/octet-stream | 21.5 MBytes | 0201_20231207_155538_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.712 | 6303.8 | 6.8804 | 251 | 2023-12-07T15:55:26 | 56.82576100 | -52.2759282 | 37.77 | 3522.1084 | 2023-12-07T16:25:09 | 56.84111105 | -52.2138887 | 173.87 | 3522.3008 | 2023-12-07T15:55:26 | 56.82576100 | -52.2759282 | -3522.1084 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0202_20231207_162539_MerianEM122.all | application/octet-stream | 21 MBytes | 0202_20231207_162539_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.820 | 9421.3 | 10.2475 | 227 | 2023-12-07T16:25:24 | 56.83967690 | -52.2138384 | 177.32 | 3524.1006 | 2023-12-07T16:55:13 | 56.75511065 | -52.2140595 | 175.14 | 3532.2539 | 2023-12-07T16:25:24 | 56.83967690 | -52.2138384 | -3524.1006 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0203_20231207_165543_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0203_20231207_165543_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 6748.5 | 7.3590 | 264 | 2023-12-07T16:55:28 | 56.75361165 | -52.2140020 | 174.60 | 3530.9155 | 2023-12-07T17:25:13 | 56.74805115 | -52.2555742 | 268.04 | 3528.8567 | 2023-12-07T16:55:28 | 56.75361165 | -52.2140020 | -3530.9155 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0204_20231207_172538_MerianEM122.all | application/octet-stream | 21 MBytes | 0204_20231207_172538_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.826 | 8930.3 | 9.7116 | 236 | 2023-12-07T17:25:25 | 56.74788815 | -52.2574647 | 263.76 | 3527.6936 | 2023-12-07T17:55:14 | 56.73385070 | -52.4010590 | 263.91 | 3514.7473 | 2023-12-07T17:25:25 | 56.74788815 | -52.2574647 | -3527.6936 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0205_20231207_175546_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0205_20231207_175546_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.658 | 5728.2 | 6.2642 | 261 | 2023-12-07T17:55:30 | 56.73354115 | -52.4038441 | 259.62 | 3520.9873 | 2023-12-07T18:25:09 | 56.75561895 | -52.3859309 | 36.25 | 3517.1340 | 2023-12-07T17:55:30 | 56.73354115 | -52.4038441 | -3520.9873 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0206_20231207_182536_MerianEM122.all | application/octet-stream | 21.5 MBytes | 0206_20231207_182536_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.844 | 5578.3 | 6.0618 | 269 | 2023-12-07T18:25:22 | 56.75626595 | -52.3847278 | 37.50 | 3517.7957 | 2023-12-07T18:55:13 | 56.79142000 | -52.3199222 | 35.62 | 3522.3345 | 2023-12-07T18:25:22 | 56.75626595 | -52.3847278 | -3517.7957 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0207_20231207_185540_MerianEM122.all | application/octet-stream | 21.5 MBytes | 0207_20231207_185540_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.922 | 4107.6 | 4.4523 | 291 | 2023-12-07T18:55:26 | 56.79189455 | -52.3191406 | 36.26 | 3519.5225 | 2023-12-07T19:25:21 | 56.81776760 | -52.2714945 | 36.97 | 3522.7393 | 2023-12-07T18:55:26 | 56.79189455 | -52.3191406 | -3519.5225 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0208_20231207_192545_MerianEM122.all | application/octet-stream | 13.4 MBytes | 0208_20231207_192545_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 20.118 | 1856.0 | 2.9917 | 165 | 2023-12-07T19:25:33 | 56.81822400 | -52.2707033 | 36.48 | 3525.3499 | 2023-12-07T19:45:40 | 56.82327840 | -52.2479464 | 47.32 | 3530.5891 | 2023-12-07T19:25:33 | 56.81822400 | -52.2707033 | -3525.3499 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0209_20231208_123708_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0209_20231208_123708_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.652 | 9339.5 | 10.2162 | 230 | 2023-12-08T12:36:59 | 56.92749150 | -51.5894780 | 238.83 | 3548.1658 | 2023-12-08T13:06:38 | 56.89035735 | -51.7267959 | 245.57 | 3557.3250 | 2023-12-08T12:36:59 | 56.92749150 | -51.5894780 | -3548.1658 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0210_20231208_130710_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0210_20231208_130710_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.688 | 9138.9 | 9.9837 | 221 | 2023-12-08T13:06:54 | 56.88977130 | -51.7292221 | 243.01 | 3556.7275 | 2023-12-08T13:36:35 | 56.85717060 | -51.8666642 | 252.60 | 3536.0176 | 2023-12-08T13:06:54 | 56.88977130 | -51.7292221 | -3556.7275 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0211_20231208_133705_MerianEM122.all | application/octet-stream | 18.7 MBytes | 0211_20231208_133705_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 27.510 | 7925.1 | 9.3427 | 197 | 2023-12-08T13:36:50 | 56.85674690 | -51.8689884 | 249.20 | 3540.5173 | 2023-12-08T14:04:20 | 56.83008255 | -51.9880520 | 52.05 | 3534.5601 | 2023-12-08T13:36:50 | 56.85674690 | -51.8689884 | -3540.5173 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0212_20231208_141543_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0212_20231208_141543_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.502 | 7723.6 | 8.4909 | 212 | 2023-12-08T14:15:43 | 56.83095165 | -51.9814123 | 252.28 | 3534.7756 | 2023-12-08T14:45:13 | 56.79618905 | -52.0882293 | 206.34 | 3529.5779 | 2023-12-08T14:15:43 | 56.83095165 | -51.9814123 | -3534.7756 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0213_20231208_144546_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0213_20231208_144546_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.820 | 4646.0 | 5.0531 | 238 | 2023-12-08T14:45:30 | 56.79518825 | -52.0885659 | 146.44 | 3530.8530 | 2023-12-08T15:15:19 | 56.81412295 | -52.0227149 | 56.87 | 3536.0139 | 2023-12-08T14:45:30 | 56.79518825 | -52.0885659 | -3530.8530 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0214_20231208_151547_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0214_20231208_151547_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.760 | 5246.3 | 5.7175 | 242 | 2023-12-08T15:15:33 | 56.81448485 | -52.0213522 | 55.55 | 3535.4971 | 2023-12-08T15:45:19 | 56.83755590 | -51.9465809 | 55.54 | 3535.7957 | 2023-12-08T15:15:33 | 56.81448485 | -52.0213522 | -3535.4971 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0215_20231208_154543_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0215_20231208_154543_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.754 | 5266.9 | 5.7406 | 243 | 2023-12-08T15:45:31 | 56.83789180 | -51.9455105 | 56.43 | 3533.4805 | 2023-12-08T16:15:16 | 56.86155585 | -51.8709664 | 50.79 | 3543.5850 | 2023-12-08T15:45:31 | 56.83789180 | -51.9455105 | -3533.4805 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0216_20231208_161540_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0216_20231208_161540_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 7926.0 | 8.6223 | 225 | 2023-12-08T16:15:28 | 56.86192635 | -51.8701055 | 50.92 | 3540.6824 | 2023-12-08T16:45:17 | 56.81765370 | -51.9484165 | 243.57 | 3537.2344 | 2023-12-08T16:15:28 | 56.86192635 | -51.8701055 | -3540.6824 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0217_20231208_164551_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0217_20231208_164551_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.664 | 8216.6 | 8.9827 | 209 | 2023-12-08T16:45:34 | 56.81700825 | -51.9507538 | 242.91 | 3537.9585 | 2023-12-08T17:15:14 | 56.78028265 | -52.0672037 | 239.94 | 3530.8870 | 2023-12-08T16:45:34 | 56.81700825 | -51.9507538 | -3537.9585 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0218_20231208_171547_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0218_20231208_171547_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.712 | 8277.3 | 9.0361 | 216 | 2023-12-08T17:15:31 | 56.77950705 | -52.0694614 | 239.09 | 3534.1794 | 2023-12-08T17:45:13 | 56.74168225 | -52.1853988 | 209.57 | 3534.4514 | 2023-12-08T17:15:31 | 56.77950705 | -52.0694614 | -3534.1794 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0219_20231208_174544_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0219_20231208_174544_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.886 | 5989.8 | 6.4998 | 241 | 2023-12-08T17:45:29 | 56.74055900 | -52.1865856 | 206.88 | 3535.9556 | 2023-12-08T18:15:22 | 56.72971575 | -52.1693057 | 51.57 | 3538.1335 | 2023-12-08T17:45:29 | 56.74055900 | -52.1865856 | -3535.9556 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0220_20231208_181542_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0220_20231208_181542_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.598 | 4612.1 | 5.0537 | 287 | 2023-12-08T18:15:42 | 56.72994140 | -52.1684957 | 53.33 | 3548.7625 | 2023-12-08T18:45:18 | 56.75002510 | -52.1028346 | 47.12 | 3534.1721 | 2023-12-08T18:15:42 | 56.72994140 | -52.1684957 | -3548.7625 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0221_20231208_184538_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0221_20231208_184538_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.946 | 4247.7 | 4.6007 | 261 | 2023-12-08T18:45:28 | 56.75028960 | -52.1021020 | 44.88 | 3538.8330 | 2023-12-08T19:15:24 | 56.76450255 | -52.0442259 | 52.96 | 3538.1904 | 2023-12-08T18:45:28 | 56.75028960 | -52.1021020 | -3538.8330 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0222_20231208_191543_MerianEM122.all | application/octet-stream | 18 MBytes | 0222_20231208_191543_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 27.180 | 1532.2 | 1.8282 | 247 | 2023-12-08T19:15:34 | 56.76443645 | -52.0440823 | 47.55 | 3534.8213 | 2023-12-08T19:42:44 | 56.76451275 | -52.0231486 | 50.16 | 3543.9312 | 2023-12-08T19:15:34 | 56.76443645 | -52.0440823 | -3534.8213 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0223_20231208_200521_MerianEM122.all | application/octet-stream | 472.9 kBytes | 0223_20231208_200521_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 0.318 | 18.4 | 1.8965 | 3 | 2023-12-08T20:05:28 | 56.76725255 | -51.9963768 | 49.19 | 3538.3665 | 2023-12-08T20:05:47 | 56.76726060 | -51.9960757 | 50.72 | 3543.1777 | 2023-12-08T20:05:28 | 56.76725255 | -51.9963768 | -3538.3665 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0224_20231209_120715_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0224_20231209_120715_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.844 | 8559.7 | 9.3018 | 252 | 2023-12-09T12:07:07 | 56.79732115 | -50.5373079 | 261.58 | 3606.8999 | 2023-12-09T12:36:57 | 56.78571490 | -50.6756507 | 265.03 | 3602.5627 | 2023-12-09T12:07:07 | 56.79732115 | -50.5373079 | -3606.8999 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0225_20231209_123727_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0225_20231209_123727_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 8439.1 | 9.2036 | 242 | 2023-12-09T12:37:12 | 56.78556190 | -50.6778755 | 265.76 | 3601.3972 | 2023-12-09T13:06:57 | 56.77440825 | -50.8143864 | 266.42 | 3600.1042 | 2023-12-09T12:37:12 | 56.78556190 | -50.6778755 | -3601.3972 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0226_20231209_130724_MerianEM122.all | application/octet-stream | 21.5 MBytes | 0226_20231209_130724_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.754 | 8434.8 | 9.1946 | 249 | 2023-12-09T13:07:10 | 56.77425870 | -50.8164919 | 266.25 | 3600.0806 | 2023-12-09T13:36:55 | 56.76046535 | -50.9520721 | 264.82 | 3592.6438 | 2023-12-09T13:07:10 | 56.77425870 | -50.8164919 | -3600.0806 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0227_20231209_133725_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0227_20231209_133725_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.634 | 8406.0 | 9.1996 | 242 | 2023-12-09T13:37:10 | 56.76018540 | -50.9544087 | 265.51 | 3595.2390 | 2023-12-09T14:06:48 | 56.74409800 | -51.0886228 | 265.49 | 3588.4043 | 2023-12-09T13:37:10 | 56.76018540 | -50.9544087 | -3595.2390 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0228_20231209_140715_MerianEM122.all | application/octet-stream | 21.5 MBytes | 0228_20231209_140715_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.892 | 8547.5 | 9.2733 | 249 | 2023-12-09T14:07:01 | 56.74385245 | -51.0906339 | 265.36 | 3965.6990 | 2023-12-09T14:36:55 | 56.72983460 | -51.2277355 | 274.04 | 3582.1875 | 2023-12-09T14:07:01 | 56.74385245 | -51.0906339 | -3965.6990 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0229_20231209_143722_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0229_20231209_143722_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.604 | 8514.4 | 9.3281 | 245 | 2023-12-09T14:37:08 | 56.72974495 | -51.2298539 | 271.65 | 3586.6189 | 2023-12-09T15:06:44 | 56.72305605 | -51.3683217 | 268.10 | 3583.7146 | 2023-12-09T14:37:08 | 56.72974495 | -51.2298539 | -3586.6189 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0230_20231209_150713_MerianEM122.all | application/octet-stream | 21.6 MBytes | 0230_20231209_150713_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.958 | 8575.8 | 9.2847 | 247 | 2023-12-09T15:06:59 | 56.72293245 | -51.3705908 | 271.15 | 3580.0391 | 2023-12-09T15:36:56 | 56.71656540 | -51.5100952 | 271.35 | 3561.7820 | 2023-12-09T15:06:59 | 56.72293245 | -51.3705908 | -3580.0391 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0231_20231209_153725_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0231_20231209_153725_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 8479.3 | 9.2233 | 242 | 2023-12-09T15:37:11 | 56.71648685 | -51.5122876 | 268.45 | 3559.3987 | 2023-12-09T16:07:00 | 56.70967275 | -51.6501005 | 268.34 | 3556.2678 | 2023-12-09T15:37:11 | 56.71648685 | -51.5122876 | -3559.3987 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0232_20231209_160725_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0232_20231209_160725_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.688 | 8135.4 | 8.8870 | 234 | 2023-12-09T16:07:12 | 56.70961420 | -51.6519561 | 269.21 | 3554.1448 | 2023-12-09T16:36:54 | 56.70345340 | -51.7842196 | 268.82 | 3552.5251 | 2023-12-09T16:07:12 | 56.70961420 | -51.6519561 | -3554.1448 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0233_20231209_163726_MerianEM122.all | application/octet-stream | 20 MBytes | 0233_20231209_163726_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 6512.3 | 7.0794 | 232 | 2023-12-09T16:37:10 | 56.70331825 | -51.7866540 | 266.98 | 3550.8088 | 2023-12-09T17:07:00 | 56.69576020 | -51.8917007 | 267.99 | 3541.8938 | 2023-12-09T16:37:10 | 56.70331825 | -51.7866540 | -3550.8088 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0234_20231209_170724_MerianEM122.all | application/octet-stream | 21.6 MBytes | 0234_20231209_170724_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.760 | 6353.0 | 6.9235 | 270 | 2023-12-09T17:07:12 | 56.69563135 | -51.8931569 | 269.08 | 3543.8984 | 2023-12-09T17:36:57 | 56.70653075 | -51.8874470 | 64.52 | 3541.0730 | 2023-12-09T17:07:12 | 56.69563135 | -51.8931569 | -3543.8984 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0235_20231209_173724_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0235_20231209_173724_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.694 | 6532.2 | 7.1346 | 277 | 2023-12-09T17:37:10 | 56.70674035 | -51.8859544 | 63.81 | 3544.0171 | 2023-12-09T18:06:52 | 56.72098935 | -51.7825507 | 66.15 | 3549.7063 | 2023-12-09T17:37:10 | 56.70674035 | -51.8859544 | -3544.0171 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0236_20231209_180715_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0236_20231209_180715_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.790 | 6563.3 | 7.1461 | 265 | 2023-12-09T18:07:03 | 56.72119780 | -51.7811577 | 66.96 | 3550.7979 | 2023-12-09T18:36:50 | 56.73713190 | -51.6781394 | 55.22 | 3554.8530 | 2023-12-09T18:07:03 | 56.72119780 | -51.7811577 | -3550.7979 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0237_20231209_183720_MerianEM122.all | application/octet-stream | 21.6 MBytes | 0237_20231209_183720_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 6857.1 | 7.4587 | 272 | 2023-12-09T18:37:04 | 56.73757375 | -51.6765812 | 56.28 | 3555.8730 | 2023-12-09T19:06:53 | 56.73967565 | -51.7528409 | 269.63 | 3562.0588 | 2023-12-09T18:37:04 | 56.73757375 | -51.6765812 | -3555.8730 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0238_20231209_190721_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0238_20231209_190721_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.478 | 7560.8 | 8.3182 | 244 | 2023-12-09T19:07:07 | 56.73962365 | -51.7548321 | 272.88 | 3549.8489 | 2023-12-09T19:36:36 | 56.73304195 | -51.8776833 | 266.01 | 3551.1191 | 2023-12-09T19:07:07 | 56.73962365 | -51.7548321 | -3549.8489 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0239_20231209_193724_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0239_20231209_193724_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.730 | 7478.7 | 8.1581 | 249 | 2023-12-09T19:37:08 | 56.73283500 | -51.8809800 | 268.04 | 3553.2866 | 2023-12-09T20:06:52 | 56.73373990 | -51.9685560 | 51.94 | 3541.5342 | 2023-12-09T19:37:08 | 56.73283500 | -51.8809800 | -3553.2866 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0240_20231209_200718_MerianEM122.all | application/octet-stream | 17.2 MBytes | 0240_20231209_200718_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 24.204 | 6184.1 | 8.2860 | 197 | 2023-12-09T20:07:18 | 56.73421710 | -51.9669956 | 49.97 | 3542.3901 | 2023-12-09T20:31:30 | 56.74701265 | -51.8708641 | 69.70 | 3545.4578 | 2023-12-09T20:07:18 | 56.73421710 | -51.9669956 | -3542.3901 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0241_20231210_122340_MerianEM122.all | application/octet-stream | 11 MBytes | 0241_20231210_122340_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 14.526 | 2500.8 | 5.5845 | 105 | 2023-12-10T12:23:24 | 56.68382865 | -51.7844312 | 250.58 | 3554.4038 | 2023-12-10T12:37:56 | 56.67474630 | -51.8214090 | 259.18 | 3554.1963 | 2023-12-10T12:23:24 | 56.68382865 | -51.7844312 | -3554.4038 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0242_20231210_171404_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0242_20231210_171404_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.580 | 10525.6 | 11.5413 | 210 | 2023-12-10T17:13:47 | 56.71318675 | -51.7699104 | 269.94 | 3550.1753 | 2023-12-10T17:43:22 | 56.71418365 | -51.9417303 | 267.91 | 3541.6443 | 2023-12-10T17:13:47 | 56.71318675 | -51.7699104 | -3550.1753 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0243_20231210_174356_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0243_20231210_174356_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.868 | 10583.8 | 11.4926 | 214 | 2023-12-10T17:43:39 | 56.71417505 | -51.9451421 | 268.02 | 3540.0168 | 2023-12-10T18:13:31 | 56.71307480 | -52.1179381 | 267.94 | 3540.8813 | 2023-12-10T17:43:39 | 56.71417505 | -51.9451421 | -3540.0168 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0244_20231210_181404_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0244_20231210_181404_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 10419.9 | 11.3853 | 216 | 2023-12-10T18:13:47 | 56.71305030 | -52.1210938 | 268.37 | 3539.2656 | 2023-12-10T18:43:28 | 56.71153110 | -52.2912008 | 266.89 | 3528.5923 | 2023-12-10T18:13:47 | 56.71305030 | -52.1210938 | -3539.2656 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0245_20231210_184402_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0245_20231210_184402_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.646 | 10656.4 | 11.6586 | 215 | 2023-12-10T18:43:44 | 56.71151925 | -52.2944524 | 266.95 | 3529.1042 | 2023-12-10T19:13:23 | 56.70952270 | -52.4683871 | 262.56 | 3512.3289 | 2023-12-10T18:43:44 | 56.71151925 | -52.2944524 | -3529.1042 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0246_20231210_191356_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0246_20231210_191356_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 10543.6 | 11.4539 | 218 | 2023-12-10T19:13:39 | 56.70941275 | -52.4715310 | 263.06 | 3512.1838 | 2023-12-10T19:43:31 | 56.71545255 | -52.6373255 | 74.90 | 3497.8264 | 2023-12-10T19:13:39 | 56.70941275 | -52.4715310 | -3512.1838 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0247_20231210_194357_MerianEM122.all | application/octet-stream | 15.9 MBytes | 0247_20231210_194357_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 22.872 | 713.0 | 1.0111 | 197 | 2023-12-10T19:43:44 | 56.71571810 | -52.6359985 | 82.46 | 3502.2310 | 2023-12-10T20:06:36 | 56.71732220 | -52.6299905 | 88.54 | 3502.2002 | 2023-12-10T19:43:44 | 56.71571810 | -52.6359985 | -3502.2310 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0248_20231211_162516_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0248_20231211_162516_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.664 | 9551.6 | 10.4432 | 212 | 2023-12-11T16:25:00 | 56.76599710 | -51.5703509 | 34.60 | 3560.6313 | 2023-12-11T16:54:40 | 56.83329260 | -51.4735334 | 39.27 | 3561.2310 | 2023-12-11T16:25:00 | 56.76599710 | -51.5703509 | -3560.6313 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0249_20231211_165512_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0249_20231211_165512_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 8920.4 | 9.6973 | 209 | 2023-12-11T16:54:55 | 56.83451470 | -51.4717364 | 36.43 | 3570.5549 | 2023-12-11T17:24:46 | 56.89654440 | -51.4041912 | 239.58 | 3581.8259 | 2023-12-11T16:54:55 | 56.83451470 | -51.4717364 | -3570.5549 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0250_20231211_172512_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0250_20231211_172512_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.772 | 7163.8 | 7.8042 | 228 | 2023-12-11T17:24:58 | 56.89617685 | -51.4055867 | 241.78 | 3581.7561 | 2023-12-11T17:54:45 | 56.85333350 | -51.4906687 | 223.23 | 3561.7571 | 2023-12-11T17:24:58 | 56.89617685 | -51.4055867 | -3581.7561 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0251_20231211_175513_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0251_20231211_175513_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.706 | 7093.6 | 7.7450 | 240 | 2023-12-11T17:54:58 | 56.85256380 | -51.4919529 | 220.32 | 3559.9485 | 2023-12-11T18:24:41 | 56.80383570 | -51.5666874 | 221.79 | 3564.1895 | 2023-12-11T17:54:58 | 56.85256380 | -51.4919529 | -3559.9485 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0252_20231211_182514_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0252_20231211_182514_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 7432.1 | 8.1210 | 215 | 2023-12-11T18:24:57 | 56.80288640 | -51.5682338 | 220.96 | 3562.9082 | 2023-12-11T18:54:38 | 56.75174370 | -51.6462224 | 217.75 | 3554.2539 | 2023-12-11T18:24:57 | 56.80288640 | -51.5682338 | -3562.9082 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0253_20231211_185511_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0253_20231211_185511_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.676 | 8880.8 | 9.7053 | 210 | 2023-12-11T18:54:55 | 56.75068570 | -51.6478558 | 222.21 | 3557.5405 | 2023-12-11T19:24:35 | 56.79958425 | -51.6047691 | 37.76 | 3557.9321 | 2023-12-11T18:54:55 | 56.75068570 | -51.6478558 | -3557.5405 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0254_20231211_192510_MerianEM122.all | application/octet-stream | 7.3 MBytes | 0254_20231211_192510_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 10.398 | 3196.4 | 9.9692 | 76 | 2023-12-11T19:24:53 | 56.80085080 | -51.6028295 | 36.57 | 3560.2256 | 2023-12-11T19:35:17 | 56.82287060 | -51.5692723 | 39.57 | 3573.5046 | 2023-12-11T19:24:53 | 56.80085080 | -51.6028295 | -3560.2256 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0255_20231211_215348_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0255_20231211_215348_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.604 | 7975.5 | 8.7367 | 214 | 2023-12-11T21:53:31 | 56.86589675 | -51.5047477 | 39.86 | 3561.8914 | 2023-12-11T22:23:07 | 56.87176435 | -51.5168118 | 218.70 | 3555.9663 | 2023-12-11T21:53:31 | 56.86589675 | -51.5047477 | -3561.8914 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0256_20231211_222340_MerianEM122.all | application/octet-stream | 18.3 MBytes | 0256_20231211_222340_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 26.754 | 3375.5 | 4.0923 | 195 | 2023-12-11T22:23:24 | 56.87090085 | -51.5180413 | 218.78 | 3556.3293 | 2023-12-11T22:50:09 | 56.84782505 | -51.5522372 | 217.04 | 3561.2791 | 2023-12-11T22:23:24 | 56.87090085 | -51.5180413 | -3556.3293 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0257_20231212_023131_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0257_20231212_023131_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.694 | 3086.5 | 3.3713 | 227 | 2023-12-12T02:31:13 | 56.77207700 | -51.6709148 | 202.33 | 3553.5781 | 2023-12-12T03:00:54 | 56.79029515 | -51.6616058 | 32.99 | 3550.1836 | 2023-12-12T02:31:13 | 56.77207700 | -51.6709148 | -3553.5781 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0258_20231212_030127_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0258_20231212_030127_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 4827.1 | 5.2653 | 206 | 2023-12-12T03:01:10 | 56.79091915 | -51.6607455 | 34.73 | 3554.3953 | 2023-12-12T03:30:55 | 56.82401820 | -51.6097603 | 37.56 | 3564.7014 | 2023-12-12T03:01:10 | 56.79091915 | -51.6607455 | -3554.3953 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0259_20231212_033129_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0259_20231212_033129_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.730 | 4988.5 | 5.4421 | 209 | 2023-12-12T03:31:11 | 56.82474585 | -51.6086373 | 38.22 | 3561.5144 | 2023-12-12T04:00:55 | 56.85905900 | -51.5561279 | 36.98 | 3552.9795 | 2023-12-12T03:31:11 | 56.82474585 | -51.6086373 | -3561.5144 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0260_20231212_040130_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0260_20231212_040130_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 5452.4 | 5.9450 | 208 | 2023-12-12T04:01:12 | 56.85984595 | -51.5549965 | 38.05 | 3554.1875 | 2023-12-12T04:30:57 | 56.89725450 | -51.4973255 | 38.35 | 3559.1179 | 2023-12-12T04:01:12 | 56.85984595 | -51.5549965 | -3554.1875 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0261_20231212_043130_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0261_20231212_043130_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.646 | 5438.9 | 5.9499 | 208 | 2023-12-12T04:31:13 | 56.89797690 | -51.4962402 | 38.31 | 3558.7891 | 2023-12-12T05:00:52 | 56.93531275 | -51.4737897 | 270.40 | 3573.1599 | 2023-12-12T04:31:13 | 56.89797690 | -51.4962402 | -3558.7891 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0262_20231212_050127_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0262_20231212_050127_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.916 | 4771.1 | 5.1724 | 208 | 2023-12-12T05:01:10 | 56.93539205 | -51.4755041 | 265.28 | 3572.7771 | 2023-12-12T05:31:05 | 56.90590790 | -51.5298937 | 216.56 | 3553.5991 | 2023-12-12T05:01:10 | 56.93539205 | -51.4755041 | -3572.7771 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0263_20231212_053138_MerianEM122.all | application/octet-stream | 7.1 MBytes | 0263_20231212_053138_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 10.158 | 1688.4 | 5.3909 | 72 | 2023-12-12T05:31:22 | 56.90528180 | -51.5308512 | 215.56 | 3553.7529 | 2023-12-12T05:41:31 | 56.89370125 | -51.5487178 | 217.47 | 3554.6526 | 2023-12-12T05:31:22 | 56.90528180 | -51.5308512 | -3553.7529 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0264_20231212_054224_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0264_20231212_054224_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.580 | 4999.4 | 5.4820 | 204 | 2023-12-12T05:42:07 | 56.89260005 | -51.5504188 | 217.73 | 3556.3740 | 2023-12-12T06:11:41 | 56.85825225 | -51.6031613 | 216.93 | 3561.8093 | 2023-12-12T05:42:07 | 56.89260005 | -51.5504188 | -3556.3740 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0265_20231212_061217_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0265_20231212_061217_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.772 | 5007.0 | 5.4548 | 206 | 2023-12-12T06:11:59 | 56.85751230 | -51.6042826 | 216.44 | 3566.4570 | 2023-12-12T06:41:45 | 56.82321360 | -51.6572614 | 212.38 | 3559.1890 | 2023-12-12T06:11:59 | 56.85751230 | -51.6042826 | -3566.4570 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0266_20231212_064220_MerianEM122.all | application/octet-stream | 17.7 MBytes | 0266_20231212_064220_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 25.632 | 3880.1 | 4.9095 | 185 | 2023-12-12T06:42:03 | 56.82256115 | -51.6581554 | 212.72 | 3556.0813 | 2023-12-12T07:07:41 | 56.82455455 | -51.6777099 | 42.42 | 3556.1865 | 2023-12-12T06:42:03 | 56.82256115 | -51.6581554 | -3556.0813 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0267_20231212_164306_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0267_20231212_164306_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 8592.4 | 9.3879 | 212 | 2023-12-12T16:42:50 | 56.93198120 | -51.6435625 | 345.98 | 3545.0989 | 2023-12-12T17:12:31 | 56.87427535 | -51.6668589 | 179.64 | 3562.5547 | 2023-12-12T16:42:50 | 56.93198120 | -51.6435625 | -3545.0989 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0268_20231212_171304_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0268_20231212_171304_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.706 | 8608.9 | 9.3989 | 214 | 2023-12-12T17:12:47 | 56.87279210 | -51.6668538 | 179.79 | 3563.2566 | 2023-12-12T17:42:29 | 56.79580970 | -51.6655142 | 149.83 | 3554.8398 | 2023-12-12T17:12:47 | 56.87279210 | -51.6668538 | -3563.2566 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0269_20231212_174301_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0269_20231212_174301_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.802 | 9036.1 | 9.8338 | 210 | 2023-12-12T17:42:45 | 56.79455470 | -51.6642770 | 149.52 | 3554.2227 | 2023-12-12T18:12:33 | 56.84558330 | -51.6157773 | 1.16 | 3567.4556 | 2023-12-12T17:42:45 | 56.79455470 | -51.6642770 | -3554.2227 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0270_20231212_181308_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0270_20231212_181308_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.658 | 9385.6 | 10.2626 | 208 | 2023-12-12T18:12:50 | 56.84723130 | -51.6156196 | 0.95 | 3562.9612 | 2023-12-12T18:42:30 | 56.93144240 | -51.6095239 | 359.73 | 3547.7041 | 2023-12-12T18:12:50 | 56.84723130 | -51.6156196 | -3562.9612 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0271_20231212_184305_MerianEM122.all | application/octet-stream | 4.9 MBytes | 0271_20231212_184305_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 6.924 | 1868.7 | 8.7565 | 52 | 2023-12-12T18:42:47 | 56.93311425 | -51.6094202 | 2.41 | 3544.2791 | 2023-12-12T18:49:43 | 56.94193955 | -51.5926534 | 161.90 | 3556.7458 | 2023-12-12T18:42:47 | 56.93311425 | -51.6094202 | -3544.2791 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0272_20231212_235937_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0272_20231212_235937_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.892 | 6180.1 | 6.7047 | 291 | 2023-12-12T23:59:28 | 56.94508240 | -51.5050969 | 34.51 | 3572.1848 | 2023-12-13T00:29:21 | 56.99528545 | -51.4782143 | 350.75 | 3582.9856 | 2023-12-12T23:59:28 | 56.94508240 | -51.5050969 | -3572.1848 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0273_20231213_002945_MerianEM122.all | application/octet-stream | 19.7 MBytes | 0273_20231213_002945_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.562 | 7767.3 | 8.5212 | 212 | 2023-12-13T00:29:33 | 56.99597095 | -51.4781846 | 351.06 | 3578.4883 | 2023-12-13T00:59:07 | 56.94226210 | -51.4495976 | 168.32 | 3572.9851 | 2023-12-13T00:29:33 | 56.99597095 | -51.4781846 | -3578.4883 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0274_20231213_005939_MerianEM122.all | application/octet-stream | 8.4 MBytes | 0274_20231213_005939_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 12.474 | 3476.1 | 9.0384 | 87 | 2023-12-13T00:59:23 | 56.94093565 | -51.4490876 | 168.24 | 3574.6992 | 2023-12-13T01:11:51 | 56.91065805 | -51.4355015 | 166.00 | 3575.4941 | 2023-12-13T00:59:23 | 56.94093565 | -51.4490876 | -3574.6992 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0275_20231213_012033_MerianEM122.all | application/octet-stream | 19.9 MBytes | 0275_20231213_012033_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.580 | 8559.4 | 9.3846 | 212 | 2023-12-13T01:20:24 | 56.89348030 | -51.4095673 | 127.98 | 3578.0271 | 2023-12-13T01:49:59 | 56.82452885 | -51.3524660 | 165.37 | 3574.1707 | 2023-12-13T01:20:24 | 56.89348030 | -51.4095673 | -3578.0271 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0276_20231213_015030_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0276_20231213_015030_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.820 | 5877.9 | 6.3930 | 252 | 2023-12-13T01:50:14 | 56.82318090 | -51.3517825 | 164.56 | 3576.0188 | 2023-12-13T02:20:04 | 56.80004340 | -51.3704080 | 303.05 | 3546.2769 | 2023-12-13T01:50:14 | 56.82318090 | -51.3517825 | -3576.0188 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0277_20231213_022028_MerianEM122.all | application/octet-stream | 4.1 MBytes | 0277_20231213_022028_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 5.412 | 885.5 | 5.3041 | 57 | 2023-12-13T02:20:16 | 56.80045890 | -51.3714880 | 306.02 | 3569.8643 | 2023-12-13T02:25:40 | 56.80509710 | -51.3832430 | 306.01 | 3566.9429 | 2023-12-13T02:20:16 | 56.80045890 | -51.3714880 | -3569.8643 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0278_20231213_065328_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0278_20231213_065328_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.406 | 5843.9 | 6.4451 | 277 | 2023-12-13T06:53:19 | 56.87662505 | -51.3538381 | 340.85 | 3585.3035 | 2023-12-13T07:22:44 | 56.92750880 | -51.3757774 | 330.93 | 3578.5903 | 2023-12-13T06:53:19 | 56.87662505 | -51.3538381 | -3585.3035 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0279_20231213_072320_MerianEM122.all | application/octet-stream | 21.3 MBytes | 0279_20231213_072320_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.760 | 5710.3 | 6.2233 | 285 | 2023-12-13T07:23:20 | 56.92852360 | -51.3764480 | 330.21 | 3580.4922 | 2023-12-13T07:53:05 | 56.97532350 | -51.4137232 | 316.76 | 3577.2136 | 2023-12-13T07:23:20 | 56.92852360 | -51.3764480 | -3580.4922 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0280_20231213_075329_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0280_20231213_075329_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.526 | 5474.6 | 6.0137 | 255 | 2023-12-13T07:53:17 | 56.97587365 | -51.4144414 | 317.06 | 3575.9028 | 2023-12-13T08:22:49 | 57.01886705 | -51.4559625 | 18.37 | 3820.0817 | 2023-12-13T07:53:17 | 56.97587365 | -51.4144414 | -3575.9028 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0281_20231213_082324_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0281_20231213_082324_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.598 | 6299.7 | 6.9033 | 249 | 2023-12-13T08:23:24 | 57.01964290 | -51.4547988 | 53.10 | 3575.7173 | 2023-12-13T08:52:59 | 56.97709680 | -51.3904072 | 148.34 | 3577.8875 | 2023-12-13T08:23:24 | 57.01964290 | -51.4547988 | -3575.7173 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0282_20231213_085327_MerianEM122.all | application/octet-stream | 19.8 MBytes | 0282_20231213_085327_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.748 | 6230.6 | 6.7933 | 217 | 2023-12-13T08:53:14 | 56.97635215 | -51.3894643 | 147.41 | 3579.6670 | 2023-12-13T09:22:58 | 56.92546120 | -51.3488613 | 163.93 | 3577.4983 | 2023-12-13T08:53:14 | 56.97635215 | -51.3894643 | -3579.6670 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0283_20231213_092327_MerianEM122.all | application/octet-stream | 19.8 MBytes | 0283_20231213_092327_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.640 | 5719.3 | 6.2575 | 227 | 2023-12-13T09:23:13 | 56.92462385 | -51.3483072 | 165.79 | 3579.9282 | 2023-12-13T09:52:51 | 56.88301885 | -51.3483939 | 310.10 | 3583.1033 | 2023-12-13T09:23:13 | 56.92462385 | -51.3483072 | -3579.9282 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0284_20231213_095320_MerianEM122.all | application/octet-stream | 9.1 MBytes | 0284_20231213_095320_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 12.576 | 1372.0 | 3.5378 | 127 | 2023-12-13T09:53:05 | 56.88348120 | -51.3491552 | 311.76 | 3583.9431 | 2023-12-13T10:05:40 | 56.89358765 | -51.3618038 | 311.37 | 3576.7175 | 2023-12-13T09:53:05 | 56.88348120 | -51.3491552 | -3583.9431 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0285_20231213_161507_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0285_20231213_161507_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.634 | 6870.2 | 7.5197 | 229 | 2023-12-13T16:14:57 | 56.87403470 | -51.1675041 | 197.23 | 3586.4988 | 2023-12-13T16:44:35 | 56.83919475 | -51.1975532 | 320.41 | 3578.8364 | 2023-12-13T16:14:57 | 56.87403470 | -51.1675041 | -3586.4988 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0286_20231213_164507_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0286_20231213_164507_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.802 | 5343.6 | 5.8157 | 226 | 2023-12-13T16:44:52 | 56.83992625 | -51.1983187 | 325.44 | 3580.2710 | 2023-12-13T17:14:40 | 56.88108100 | -51.2430754 | 308.66 | 3579.6533 | 2023-12-13T16:44:52 | 56.83992625 | -51.1983187 | -3580.2710 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0287_20231213_171509_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0287_20231213_171509_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 5272.6 | 5.7392 | 238 | 2023-12-13T17:14:54 | 56.88167765 | -51.2439235 | 311.66 | 3576.1558 | 2023-12-13T17:44:42 | 56.91992190 | -51.2947934 | 309.18 | 3575.9800 | 2023-12-13T17:14:54 | 56.88167765 | -51.2439235 | -3576.1558 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0288_20231213_174509_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0288_20231213_174509_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.628 | 5791.2 | 6.3391 | 217 | 2023-12-13T17:44:56 | 56.92048325 | -51.2956010 | 311.06 | 3578.1904 | 2023-12-13T18:14:33 | 56.96224135 | -51.3521374 | 316.12 | 3577.1282 | 2023-12-13T17:44:56 | 56.92048325 | -51.2956010 | -3578.1904 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0289_20231213_181502_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0289_20231213_181502_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 5505.8 | 6.0046 | 255 | 2023-12-13T18:14:48 | 56.96297780 | -51.3530886 | 317.84 | 3574.8584 | 2023-12-13T18:44:32 | 57.00281390 | -51.4065589 | 313.42 | 3581.0867 | 2023-12-13T18:14:48 | 56.96297780 | -51.3530886 | -3574.8584 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0290_20231213_184501_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0290_20231213_184501_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 5925.4 | 6.4524 | 238 | 2023-12-13T18:44:46 | 57.00348520 | -51.4075104 | 314.17 | 3576.3633 | 2023-12-13T19:14:33 | 57.04984375 | -51.4478587 | 356.46 | 3581.1770 | 2023-12-13T18:44:46 | 57.00348520 | -51.4075104 | -3576.3633 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0291_20231213_191504_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0291_20231213_191504_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.562 | 5686.3 | 6.2379 | 233 | 2023-12-13T19:14:49 | 57.05077520 | -51.4477447 | 355.14 | 3571.9792 | 2023-12-13T19:44:23 | 57.02156150 | -51.3915434 | 151.38 | 3576.8523 | 2023-12-13T19:14:49 | 57.05077520 | -51.4477447 | -3571.9792 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0292_20231213_194457_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0292_20231213_194457_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.922 | 8023.4 | 8.6968 | 225 | 2023-12-13T19:44:40 | 57.02079825 | -51.3906232 | 153.67 | 3578.0625 | 2023-12-13T20:14:35 | 56.96180910 | -51.3149306 | 145.65 | 3577.8176 | 2023-12-13T19:44:40 | 57.02079825 | -51.3906232 | -3578.0625 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0293_20231213_201509_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0293_20231213_201509_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 9077.3 | 9.9181 | 214 | 2023-12-13T20:14:52 | 56.96050960 | -51.3132206 | 144.13 | 3579.1990 | 2023-12-13T20:44:33 | 56.89371730 | -51.2278244 | 148.46 | 3578.1938 | 2023-12-13T20:14:52 | 56.96050960 | -51.3132206 | -3579.1990 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0294_20231213_204508_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0294_20231213_204508_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.568 | 8375.7 | 9.1874 | 216 | 2023-12-13T20:44:50 | 56.89234430 | -51.2260470 | 147.80 | 3580.8066 | 2023-12-13T21:14:24 | 56.92495140 | -51.2274046 | 317.83 | 3582.7378 | 2023-12-13T20:44:50 | 56.89234430 | -51.2260470 | -3580.8066 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0295_20231213_211459_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0295_20231213_211459_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.688 | 7961.6 | 8.6977 | 206 | 2023-12-13T21:14:41 | 56.92605005 | -51.2288688 | 318.59 | 3587.0850 | 2023-12-13T21:44:23 | 56.98436335 | -51.3044329 | 299.61 | 3579.4469 | 2023-12-13T21:14:41 | 56.92605005 | -51.2288688 | -3587.0850 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0296_20231213_214456_MerianEM122.all | application/octet-stream | 10.5 MBytes | 0296_20231213_214456_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 15.288 | 3002.0 | 6.3686 | 110 | 2023-12-13T21:44:40 | 56.98502365 | -51.3065328 | 287.34 | 3580.2681 | 2023-12-13T21:59:57 | 56.99541830 | -51.3520622 | 287.87 | 3581.1030 | 2023-12-13T21:44:40 | 56.98502365 | -51.3065328 | -3580.2681 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0297_20231214_041905_MerianEM122.all | application/octet-stream | 9.7 MBytes | 0297_20231214_041905_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 14.112 | 2154.6 | 4.9509 | 110 | 2023-12-14T04:18:52 | 56.89625670 | -51.2088908 | 19.42 | 3582.0474 | 2023-12-14T04:32:59 | 56.91180290 | -51.1915774 | 302.54 | 3583.7954 | 2023-12-14T04:18:52 | 56.89625670 | -51.2088908 | -3582.0474 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0298_20231214_175848_MerianEM122.all | application/octet-stream | 6.9 MBytes | 0298_20231214_175848_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 9.768 | 3526.6 | 11.7112 | 74 | 2023-12-14T17:58:39 | 57.02985765 | -51.2528929 | 141.11 | 3579.2175 | 2023-12-14T18:08:25 | 57.00424105 | -51.2188686 | 145.33 | 3580.1631 | 2023-12-14T17:58:39 | 57.02985765 | -51.2528929 | -3579.2175 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0299_20231214_202505_MerianEM122.all | application/octet-stream | 20 MBytes | 0299_20231214_202505_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.568 | 4546.8 | 4.9874 | 220 | 2023-12-14T20:24:47 | 56.87333735 | -50.7245094 | 310.31 | 3594.7256 | 2023-12-14T20:54:21 | 56.89749080 | -50.7725774 | 310.81 | 3596.9185 | 2023-12-14T20:24:47 | 56.87333735 | -50.7245094 | -3594.7256 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0300_20231214_205456_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0300_20231214_205456_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 9402.1 | 10.2273 | 205 | 2023-12-14T20:54:39 | 56.89837850 | -50.7742150 | 309.31 | 3594.8181 | 2023-12-14T21:24:28 | 56.94345015 | -50.9046903 | 299.30 | 3591.7344 | 2023-12-14T20:54:39 | 56.89837850 | -50.7742150 | -3594.8181 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0301_20231214_212502_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0301_20231214_212502_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.724 | 9110.9 | 9.9409 | 205 | 2023-12-14T21:24:44 | 56.94434075 | -50.9072407 | 300.38 | 3593.0181 | 2023-12-14T21:54:28 | 56.98769365 | -51.0342455 | 297.30 | 3590.3447 | 2023-12-14T21:24:44 | 56.94434075 | -50.9072407 | -3593.0181 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0302_20231214_215503_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0302_20231214_215503_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.490 | 9265.7 | 10.1911 | 204 | 2023-12-14T21:54:46 | 56.98854545 | -51.0368181 | 299.66 | 3590.5100 | 2023-12-14T22:24:15 | 57.02760530 | -51.1712236 | 294.45 | 3583.6660 | 2023-12-14T21:54:46 | 56.98854545 | -51.0368181 | -3590.5100 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0303_20231214_222450_MerianEM122.all | application/octet-stream | 7.8 MBytes | 0303_20231214_222450_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 11.250 | 732.6 | 2.1116 | 80 | 2023-12-14T22:24:32 | 57.02831900 | -51.1739592 | 294.98 | 3580.5972 | 2023-12-14T22:35:47 | 57.03203015 | -51.1830922 | 340.01 | 3585.2991 | 2023-12-14T22:24:32 | 57.02831900 | -51.1739592 | -3580.5972 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0304_20231215_000954_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0304_20231215_000954_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.586 | 8299.4 | 9.0977 | 203 | 2023-12-15T00:09:38 | 57.03319715 | -51.1897724 | 275.66 | 3584.5945 | 2023-12-15T00:39:13 | 57.03329350 | -51.3264303 | 269.00 | 3578.8499 | 2023-12-15T00:09:38 | 57.03319715 | -51.1897724 | -3584.5945 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0305_20231215_003948_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0305_20231215_003948_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 8666.5 | 9.3749 | 206 | 2023-12-15T00:39:30 | 57.03330330 | -51.3292328 | 270.17 | 3579.9297 | 2023-12-15T01:09:29 | 57.02735785 | -51.4689588 | 209.38 | 3577.3804 | 2023-12-15T00:39:30 | 57.03330330 | -51.3292328 | -3579.9297 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0306_20231215_010958_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0306_20231215_010958_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.532 | 8819.6 | 9.6861 | 212 | 2023-12-15T01:09:44 | 57.02621980 | -51.4700000 | 199.69 | 3577.6365 | 2023-12-15T01:39:16 | 57.01513900 | -51.3400983 | 88.51 | 3576.7764 | 2023-12-15T01:09:44 | 57.02621980 | -51.4700000 | -3577.6365 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0307_20231215_013951_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0307_20231215_013951_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.880 | 9075.4 | 9.8510 | 206 | 2023-12-15T01:39:33 | 57.01516790 | -51.3371349 | 88.63 | 3581.3555 | 2023-12-15T02:09:26 | 57.01521245 | -51.1877565 | 88.93 | 3583.9817 | 2023-12-15T01:39:33 | 57.01516790 | -51.3371349 | -3581.3555 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0308_20231215_021001_MerianEM122.all | application/octet-stream | 20 MBytes | 0308_20231215_021001_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.472 | 9132.4 | 10.0493 | 201 | 2023-12-15T02:09:44 | 57.01522245 | -51.1847317 | 89.34 | 3583.3994 | 2023-12-15T02:39:12 | 57.01510285 | -51.0344143 | 88.93 | 3590.0022 | 2023-12-15T02:09:44 | 57.01522245 | -51.1847317 | -3583.3994 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0309_20231215_023948_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0309_20231215_023948_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 8275.4 | 8.9840 | 210 | 2023-12-15T02:39:30 | 57.01510350 | -51.0312507 | 87.96 | 3587.8740 | 2023-12-15T03:09:23 | 56.99806040 | -51.0958672 | 268.59 | 3584.7766 | 2023-12-15T02:39:30 | 57.01510350 | -51.0312507 | -3587.8740 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0310_20231215_030959_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0310_20231215_030959_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 7977.1 | 8.6866 | 205 | 2023-12-15T03:09:41 | 56.99808430 | -51.0985174 | 268.68 | 3586.5063 | 2023-12-15T03:39:28 | 56.99805600 | -51.2297462 | 266.06 | 3582.7900 | 2023-12-15T03:09:41 | 56.99808430 | -51.0985174 | -3586.5063 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0311_20231215_034002_MerianEM122.all | application/octet-stream | 18.8 MBytes | 0311_20231215_034002_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 27.684 | 7568.5 | 8.8665 | 191 | 2023-12-15T03:39:45 | 56.99803050 | -51.2323450 | 269.00 | 3586.4622 | 2023-12-15T04:07:26 | 56.99814890 | -51.3568459 | 267.62 | 3580.1030 | 2023-12-15T03:39:45 | 56.99803050 | -51.2323450 | -3586.4622 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0312_20231215_122805_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0312_20231215_122805_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 9114.0 | 9.9076 | 213 | 2023-12-15T12:27:48 | 57.06646210 | -51.0746317 | 93.85 | 3582.0540 | 2023-12-15T12:57:38 | 57.06619965 | -50.9244226 | 92.06 | 3587.8247 | 2023-12-15T12:27:48 | 57.06646210 | -51.0746317 | -3582.0540 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0313_20231215_125810_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0313_20231215_125810_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.766 | 8824.5 | 9.6156 | 205 | 2023-12-15T12:57:54 | 57.06620245 | -50.9217399 | 89.18 | 3580.1392 | 2023-12-15T13:27:40 | 57.06626400 | -50.7763126 | 94.91 | 3581.9441 | 2023-12-15T12:57:54 | 57.06620245 | -50.9217399 | -3580.1392 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0314_20231215_132815_MerianEM122.all | application/octet-stream | 18.9 MBytes | 0314_20231215_132815_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 7140.0 | 7.7853 | 189 | 2023-12-15T13:27:57 | 57.06623765 | -50.7735334 | 91.23 | 3580.4009 | 2023-12-15T13:57:42 | 57.08737215 | -50.7496836 | 259.70 | 3579.2126 | 2023-12-15T13:27:57 | 57.06623765 | -50.7735334 | -3580.4009 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0315_20231215_135806_MerianEM122.all | application/octet-stream | 19 MBytes | 0315_20231215_135806_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.346 | 5467.8 | 6.0424 | 212 | 2023-12-15T13:57:54 | 57.08739830 | -50.7510836 | 260.08 | 3599.9658 | 2023-12-15T14:27:15 | 57.08782565 | -50.8411221 | 253.39 | 3598.0979 | 2023-12-15T13:57:54 | 57.08739830 | -50.7510836 | -3599.9658 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0316_20231215_142810_MerianEM122.all | application/octet-stream | 10.2 MBytes | 0316_20231215_142810_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 16.338 | 2820.3 | 5.5979 | 121 | 2023-12-15T14:28:00 | 57.08785110 | -50.8437782 | 253.66 | 3580.1533 | 2023-12-15T14:44:21 | 57.08768235 | -50.8902152 | 254.41 | 4193.9517 | 2023-12-15T14:28:00 | 57.08785110 | -50.8437782 | -3580.1533 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0317_20231215_174449_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0317_20231215_174449_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.568 | 9327.3 | 10.2305 | 214 | 2023-12-15T17:44:40 | 57.11538640 | -51.2871703 | 92.15 | 3574.7737 | 2023-12-15T18:14:14 | 57.11583210 | -51.1332574 | 91.83 | 3577.1428 | 2023-12-15T17:44:40 | 57.11538640 | -51.2871703 | -3574.7737 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0318_20231215_181448_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0318_20231215_181448_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.760 | 9478.8 | 10.3295 | 210 | 2023-12-15T18:14:30 | 57.11583285 | -51.1302873 | 93.07 | 3570.9468 | 2023-12-15T18:44:16 | 57.14240580 | -50.9869453 | 57.69 | 3573.0889 | 2023-12-15T18:14:30 | 57.11583285 | -51.1302873 | -3570.9468 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0319_20231215_184451_MerianEM122.all | application/octet-stream | 20 MBytes | 0319_20231215_184451_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 8078.8 | 8.8267 | 210 | 2023-12-15T18:44:33 | 57.14327405 | -50.9841840 | 60.90 | 3574.2825 | 2023-12-15T19:14:14 | 57.15024840 | -50.9053173 | 197.55 | 3572.3718 | 2023-12-15T18:44:33 | 57.14327405 | -50.9841840 | -3574.2825 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0320_20231215_191445_MerianEM122.all | application/octet-stream | 195.8 kBytes | 0320_20231215_191445_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 0.006 | 0.0 | 0.0000 | 2 | 2023-12-15T19:14:30 | 57.14937255 | -50.9056845 | 199.44 | 3585.1172 | 2023-12-15T19:14:30 | 57.14937255 | -50.9056845 | 199.44 | 3574.8787 | 2023-12-15T19:14:30 | 57.14937255 | -50.9056845 | -3585.1172 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0321_20231216_175837_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0321_20231216_175837_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.616 | 4302.9 | 4.7124 | 240 | 2023-12-16T17:58:28 | 57.17299400 | -50.8236078 | 61.41 | 3565.5586 | 2023-12-16T18:28:05 | 57.18740755 | -50.7577115 | 61.87 | 3563.1194 | 2023-12-16T17:58:28 | 57.17299400 | -50.8236078 | -3565.5586 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0322_20231216_182834_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0322_20231216_182834_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 4021.4 | 4.3692 | 289 | 2023-12-16T18:28:20 | 57.18763190 | -50.7565631 | 60.22 | 3571.4172 | 2023-12-16T18:58:11 | 57.20044575 | -50.6944588 | 49.88 | 3561.1250 | 2023-12-16T18:28:20 | 57.18763190 | -50.7565631 | -3571.4172 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0323_20231216_185828_MerianEM122.all | application/octet-stream | 19.2 MBytes | 0323_20231216_185828_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.172 | 4966.8 | 5.5222 | 218 | 2023-12-16T18:58:47 | 57.20070685 | -50.6932307 | 52.35 | 3559.6138 | 2023-12-16T19:27:57 | 57.21048370 | -50.7040176 | 286.60 | 3560.8728 | 2023-12-16T18:58:47 | 57.20070685 | -50.6932307 | -3559.6138 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0324_20231216_192827_MerianEM122.all | application/octet-stream | 19.6 MBytes | 0324_20231216_192827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.688 | 5743.9 | 6.2748 | 216 | 2023-12-16T19:28:12 | 57.21066845 | -50.7055248 | 285.73 | 3556.1482 | 2023-12-16T19:57:54 | 57.21174365 | -50.7983281 | 263.71 | 3572.4629 | 2023-12-16T19:28:12 | 57.21066845 | -50.7055248 | -3556.1482 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0325_20231216_195827_MerianEM122.all | application/octet-stream | 17.1 MBytes | 0325_20231216_195827_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 5187.9 | 5.6491 | 163 | 2023-12-16T19:58:17 | 57.21143205 | -50.7998763 | 263.13 | 3583.3711 | 2023-12-16T20:28:04 | 57.19529780 | -50.8801674 | 267.63 | 3571.4434 | 2023-12-16T19:58:17 | 57.21143205 | -50.7998763 | -3583.3711 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0326_20231216_202830_MerianEM122.all | application/octet-stream | 11.2 MBytes | 0326_20231216_202830_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 19.230 | 3279.8 | 5.5311 | 108 | 2023-12-16T20:28:21 | 57.19515835 | -50.8813498 | 269.24 | 3565.7639 | 2023-12-16T20:47:35 | 57.18503100 | -50.9321807 | 264.79 | 4100.9141 | 2023-12-16T20:28:21 | 57.19515835 | -50.8813498 | -3565.7639 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0327_20231217_023215_MerianEM122.all | application/octet-stream | 5.6 MBytes | 0327_20231217_023215_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 7.902 | 511.4 | 2.0992 | 52 | 2023-12-17T02:32:05 | 57.16047235 | -51.2143483 | 286.26 | 3567.5234 | 2023-12-17T02:40:00 | 57.16085765 | -51.2223100 | 283.58 | 3568.0796 | 2023-12-17T02:32:05 | 57.16047235 | -51.2143483 | -3567.5234 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0328_20231217_114207_MerianEM122.all | application/octet-stream | 797.3 kBytes | 0328_20231217_114207_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 0.858 | 128.9 | 4.8730 | 10 | 2023-12-17T11:41:57 | 57.39738085 | -51.6083815 | 117.68 | 3536.9084 | 2023-12-17T11:42:49 | 57.39685925 | -51.6064671 | 118.62 | 3535.6519 | 2023-12-17T11:41:57 | 57.39738085 | -51.6083815 | -3536.9084 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0329_20231217_121221_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0329_20231217_121221_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.772 | 8846.7 | 9.6380 | 217 | 2023-12-17T12:12:11 | 57.37286070 | -51.5141857 | 117.40 | 3543.8162 | 2023-12-17T12:41:57 | 57.33629960 | -51.3837313 | 117.84 | 3537.1990 | 2023-12-17T12:12:11 | 57.37286070 | -51.5141857 | -3543.8162 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0330_20231217_124229_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0330_20231217_124229_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.742 | 8821.7 | 9.6191 | 217 | 2023-12-17T12:42:13 | 57.33561915 | -51.3813156 | 117.85 | 3552.4216 | 2023-12-17T13:11:57 | 57.30547825 | -51.2461552 | 109.66 | 3550.1389 | 2023-12-17T12:42:13 | 57.33561915 | -51.3813156 | -3552.4216 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0331_20231217_131227_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0331_20231217_131227_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.634 | 8983.1 | 9.8312 | 214 | 2023-12-17T13:12:12 | 57.30501605 | -51.2437398 | 109.28 | 3551.4517 | 2023-12-17T13:41:50 | 57.26627970 | -51.1220075 | 158.99 | 3559.6870 | 2023-12-17T13:12:12 | 57.30501605 | -51.2437398 | -3551.4517 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0332_20231217_134222_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0332_20231217_134222_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.820 | 8228.4 | 8.9497 | 224 | 2023-12-17T13:42:06 | 57.26507325 | -51.1210363 | 158.49 | 3557.5825 | 2023-12-17T14:11:55 | 57.19762355 | -51.0654935 | 159.85 | 3567.0837 | 2023-12-17T13:42:06 | 57.26507325 | -51.1210363 | -3557.5825 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0333_20231217_141226_MerianEM122.all | application/octet-stream | 7.3 MBytes | 0333_20231217_141226_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 10.704 | 2643.6 | 8.0107 | 79 | 2023-12-17T14:12:11 | 57.19643410 | -51.0644851 | 160.15 | 3569.4089 | 2023-12-17T14:22:53 | 57.17496895 | -51.0477341 | 238.37 | 3571.1282 | 2023-12-17T14:12:11 | 57.19643410 | -51.0644851 | -3569.4089 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0334_20231217_143919_MerianEM122.all | application/octet-stream | 1.9 MBytes | 0334_20231217_143919_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 2.520 | 470.7 | 6.0645 | 26 | 2023-12-17T14:39:09 | 57.16435450 | -51.0532337 | 201.02 | 3583.9043 | 2023-12-17T14:41:40 | 57.16020530 | -51.0546862 | 197.51 | 3571.8057 | 2023-12-17T14:39:09 | 57.16435450 | -51.0532337 | -3583.9043 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0335_20231218_120429_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0335_20231218_120429_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.478 | 9382.4 | 10.3223 | 220 | 2023-12-18T12:04:20 | 56.91750730 | -52.0102833 | 59.17 | 3531.0496 | 2023-12-18T12:33:49 | 56.95550400 | -51.8727514 | 61.56 | 3541.0225 | 2023-12-18T12:04:20 | 56.91750730 | -52.0102833 | -3531.0496 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0336_20231218_123422_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0336_20231218_123422_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 9179.8 | 9.9923 | 207 | 2023-12-18T12:34:06 | 56.95622970 | -51.8702416 | 61.78 | 3540.3477 | 2023-12-18T13:03:53 | 56.99381820 | -51.7359131 | 60.76 | 3540.1519 | 2023-12-18T12:34:06 | 56.95622970 | -51.8702416 | -3540.3477 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0337_20231218_130429_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0337_20231218_130429_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.820 | 9167.7 | 9.9715 | 208 | 2023-12-18T13:04:11 | 56.99457540 | -51.7331777 | 61.78 | 3546.4468 | 2023-12-18T13:34:00 | 57.03220305 | -51.5989748 | 59.95 | 3562.0168 | 2023-12-18T13:04:11 | 56.99457540 | -51.7331777 | -3546.4468 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0338_20231218_133434_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0338_20231218_133434_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.532 | 9174.7 | 10.0761 | 211 | 2023-12-18T13:34:17 | 57.03291100 | -51.5964278 | 63.91 | 3567.0342 | 2023-12-18T14:03:48 | 57.07044250 | -51.4618670 | 61.46 | 3577.5598 | 2023-12-18T13:34:17 | 57.03291100 | -51.5964278 | -3567.0342 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0339_20231218_140423_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0339_20231218_140423_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.766 | 9274.9 | 10.1056 | 211 | 2023-12-18T14:04:06 | 57.07116750 | -51.4592515 | 62.18 | 3577.1167 | 2023-12-18T14:33:52 | 57.10992445 | -51.3238541 | 63.29 | 3575.9260 | 2023-12-18T14:04:06 | 57.07116750 | -51.4592515 | -3577.1167 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0340_20231218_143426_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0340_20231218_143426_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.748 | 9277.1 | 10.1144 | 211 | 2023-12-18T14:34:09 | 57.11066590 | -51.3212401 | 62.33 | 3575.8972 | 2023-12-18T15:03:54 | 57.17321585 | -51.2380926 | 13.96 | 3563.5347 | 2023-12-18T14:34:09 | 57.11066590 | -51.3212401 | -3575.8972 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0341_20231218_150427_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0341_20231218_150427_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.760 | 9176.4 | 10.0006 | 210 | 2023-12-18T15:04:10 | 57.17474915 | -51.2372207 | 15.09 | 3566.7632 | 2023-12-18T15:33:56 | 57.25314965 | -51.1905600 | 16.85 | 3556.5049 | 2023-12-18T15:04:10 | 57.17474915 | -51.2372207 | -3566.7632 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0342_20231218_153431_MerianEM122.all | application/octet-stream | 11.6 MBytes | 0342_20231218_153431_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 17.340 | 3833.0 | 7.1692 | 122 | 2023-12-18T15:34:13 | 57.25467300 | -51.1896042 | 16.63 | 3554.9863 | 2023-12-18T15:51:34 | 57.28371675 | -51.1671519 | 198.15 | 3543.8987 | 2023-12-18T15:34:13 | 57.25467300 | -51.1896042 | -3554.9863 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0343_20231218_172629_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0343_20231218_172629_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.496 | 155.7 | 0.1712 | 252 | 2023-12-18T17:26:41 | 57.28374690 | -51.1667040 | 201.70 | 3551.0286 | 2023-12-18T17:56:11 | 57.28368270 | -51.1663432 | 197.03 | 3853.4962 | 2023-12-18T17:26:41 | 57.28374690 | -51.1667040 | -3551.0286 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0344_20231218_175632_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0344_20231218_175632_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.790 | 163.8 | 0.1784 | 281 | 2023-12-18T17:56:22 | 57.28368850 | -51.1663245 | 196.66 | 3550.9563 | 2023-12-18T18:26:09 | 57.28366300 | -51.1659455 | 195.48 | 3560.8447 | 2023-12-18T17:56:22 | 57.28368850 | -51.1663245 | -3550.9563 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0345_20231218_182631_MerianEM122.all | application/octet-stream | 20 MBytes | 0345_20231218_182631_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.484 | 167.6 | 0.1844 | 249 | 2023-12-18T18:26:31 | 57.28364695 | -51.1659818 | 198.60 | 3553.8320 | 2023-12-18T18:56:00 | 57.28371640 | -51.1657822 | 208.30 | 3549.1174 | 2023-12-18T18:26:31 | 57.28364695 | -51.1659818 | -3553.8320 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0346_20231218_185629_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0346_20231218_185629_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 274.4 | 0.2979 | 264 | 2023-12-18T18:56:15 | 57.28372675 | -51.1657821 | 207.09 | 3550.3992 | 2023-12-18T19:26:07 | 57.28355565 | -51.1674715 | 248.01 | 3549.2634 | 2023-12-18T18:56:15 | 57.28372675 | -51.1657821 | -3550.3992 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0347_20231218_192628_MerianEM122.all | application/octet-stream | 14.9 MBytes | 0347_20231218_192628_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 22.392 | 3694.3 | 5.3504 | 168 | 2023-12-18T19:26:17 | 57.28346855 | -51.1682384 | 250.19 | 3549.8684 | 2023-12-18T19:48:41 | 57.30524655 | -51.1529016 | 26.60 | 3545.3345 | 2023-12-18T19:26:17 | 57.28346855 | -51.1682384 | -3549.8684 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0348_20231218_221706_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0348_20231218_221706_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.496 | 5939.8 | 6.5318 | 220 | 2023-12-18T22:16:56 | 57.19418385 | -51.3263118 | 220.16 | 3563.2654 | 2023-12-18T22:46:26 | 57.19717415 | -51.3500951 | 32.50 | 3562.5386 | 2023-12-18T22:16:56 | 57.19418385 | -51.3263118 | -3563.2654 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0349_20231218_224656_MerianEM122.all | application/octet-stream | 19.4 MBytes | 0349_20231218_224656_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.838 | 5278.4 | 5.7374 | 193 | 2023-12-18T22:46:41 | 57.19800195 | -51.3490314 | 30.92 | 3562.6536 | 2023-12-18T23:16:31 | 57.23644080 | -51.2982683 | 27.41 | 3557.7598 | 2023-12-18T22:46:41 | 57.19800195 | -51.3490314 | -3562.6536 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0350_20231218_231701_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0350_20231218_231701_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.808 | 5130.1 | 5.5819 | 222 | 2023-12-18T23:16:46 | 57.23710595 | -51.2975463 | 27.19 | 3569.1042 | 2023-12-18T23:46:34 | 57.27477710 | -51.2491143 | 36.44 | 3546.9172 | 2023-12-18T23:16:46 | 57.23710595 | -51.2975463 | -3569.1042 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0351_20231218_234707_MerianEM122.all | application/octet-stream | 3.2 MBytes | 0351_20231218_234707_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 4.392 | 719.6 | 5.3129 | 36 | 2023-12-18T23:46:51 | 57.27544810 | -51.2481658 | 35.67 | 3552.5918 | 2023-12-18T23:51:15 | 57.28053885 | -51.2408224 | 35.22 | 3548.9361 | 2023-12-18T23:46:51 | 57.27544810 | -51.2481658 | -3552.5918 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0352_20231220_130403_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0352_20231220_130403_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.442 | 8697.7 | 9.5810 | 218 | 2023-12-20T13:03:54 | 57.22121695 | -51.4517726 | 357.99 | 3558.2808 | 2023-12-20T13:33:20 | 57.25657150 | -51.4038148 | 133.48 | 3554.5112 | 2023-12-20T13:03:54 | 57.22121695 | -51.4517726 | -3558.2808 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0353_20231220_133353_MerianEM122.all | application/octet-stream | 3.8 MBytes | 0353_20231220_133353_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 5.286 | 1428.2 | 8.7581 | 40 | 2023-12-20T13:33:37 | 57.25565630 | -51.4019689 | 131.77 | 3563.4888 | 2023-12-20T13:38:54 | 57.24725125 | -51.3841120 | 130.18 | 3556.5786 | 2023-12-20T13:33:37 | 57.25565630 | -51.4019689 | -3563.4888 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0354_20231221_155322_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0354_20231221_155322_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.640 | 11848.5 | 12.9642 | 211 | 2023-12-21T15:53:12 | 57.03846485 | -50.6547896 | 96.08 | 3579.6133 | 2023-12-21T16:22:51 | 57.02431675 | -50.4614140 | 95.14 | 3611.5447 | 2023-12-21T15:53:12 | 57.03846485 | -50.6547896 | -3579.6133 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0355_20231221_162324_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0355_20231221_162324_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.826 | 11670.4 | 12.6893 | 214 | 2023-12-21T16:23:07 | 57.02404660 | -50.4579181 | 93.32 | 3615.5352 | 2023-12-21T16:52:57 | 57.01064750 | -50.2673868 | 96.88 | 3655.1079 | 2023-12-21T16:23:07 | 57.02404660 | -50.4579181 | -3615.5352 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0356_20231221_165330_MerianEM122.all | application/octet-stream | 21 MBytes | 0356_20231221_165330_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.730 | 5089.2 | 5.5519 | 258 | 2023-12-21T16:53:13 | 57.01035770 | -50.2638859 | 98.02 | 3656.2217 | 2023-12-21T17:22:57 | 57.02207830 | -50.2095899 | 28.22 | 3636.7004 | 2023-12-21T16:53:13 | 57.01035770 | -50.2638859 | -3656.2217 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0357_20231221_172329_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0357_20231221_172329_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.706 | 11363.8 | 12.4059 | 213 | 2023-12-21T17:23:13 | 57.02364155 | -50.2079380 | 26.87 | 3648.7185 | 2023-12-21T17:52:55 | 57.11164505 | -50.1131466 | 27.19 | 3635.5310 | 2023-12-21T17:23:13 | 57.02364155 | -50.2079380 | -3648.7185 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0358_20231221_175330_MerianEM122.all | application/octet-stream | 13.6 MBytes | 0358_20231221_175330_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 19.902 | 7278.2 | 11.8599 | 142 | 2023-12-21T17:53:12 | 57.11332205 | -50.1113341 | 28.30 | 3635.9006 | 2023-12-21T18:13:07 | 57.16782440 | -50.0478960 | 156.73 | 3627.9277 | 2023-12-21T17:53:12 | 57.11332205 | -50.1113341 | -3635.9006 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0359_20231221_182224_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0359_20231221_182224_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.724 | 11559.0 | 12.6129 | 214 | 2023-12-21T18:22:11 | 57.16055550 | -50.0580077 | 29.66 | 3624.6509 | 2023-12-21T18:51:55 | 57.24850135 | -49.9564556 | 30.27 | 3613.1003 | 2023-12-21T18:22:11 | 57.16055550 | -50.0580077 | -3624.6509 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0360_20231221_185229_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0360_20231221_185229_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 11490.6 | 12.5541 | 212 | 2023-12-21T18:52:11 | 57.25019035 | -49.9544464 | 30.95 | 3612.0574 | 2023-12-21T19:21:53 | 57.33668575 | -49.8507381 | 32.48 | 3599.9673 | 2023-12-21T18:52:11 | 57.25019035 | -49.9544464 | -3612.0574 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0361_20231221_192227_MerianEM122.all | application/octet-stream | 11.2 MBytes | 0361_20231221_192227_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 16.200 | 3733.4 | 7.4747 | 120 | 2023-12-21T19:22:10 | 57.33828960 | -49.8485796 | 31.38 | 3599.2004 | 2023-12-21T19:38:21 | 57.36074690 | -49.8117944 | 306.78 | 3600.8083 | 2023-12-21T19:22:10 | 57.33828960 | -49.8485796 | -3599.2004 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0362_20231221_195540_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0362_20231221_195540_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.514 | 11452.4 | 12.5841 | 229 | 2023-12-21T19:55:30 | 57.36186780 | -49.8109525 | 75.09 | 3609.5051 | 2023-12-21T20:25:01 | 57.34630805 | -49.6229615 | 97.52 | 3611.6284 | 2023-12-21T19:55:30 | 57.36186780 | -49.8109525 | -3609.5051 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0363_20231221_202534_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0363_20231221_202534_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.748 | 12181.0 | 13.2806 | 223 | 2023-12-21T20:25:18 | 57.34597725 | -49.6192702 | 99.51 | 3614.2576 | 2023-12-21T20:55:02 | 57.33117040 | -49.4191628 | 93.30 | 3605.3203 | 2023-12-21T20:25:18 | 57.34597725 | -49.6192702 | -3614.2576 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0364_20231221_205536_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0364_20231221_205536_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 12344.2 | 13.4093 | 231 | 2023-12-21T20:55:19 | 57.33096400 | -49.4153467 | 94.22 | 3607.2415 | 2023-12-21T21:25:11 | 57.31745145 | -49.2119941 | 93.56 | 3602.5493 | 2023-12-21T20:55:19 | 57.33096400 | -49.4153467 | -3607.2415 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0365_20231221_212540_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0365_20231221_212540_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 11999.3 | 13.1033 | 232 | 2023-12-21T21:25:25 | 57.31723990 | -49.2086467 | 93.91 | 3605.1265 | 2023-12-21T21:55:07 | 57.28208845 | -49.0223310 | 112.05 | 3599.9392 | 2023-12-21T21:25:25 | 57.31723990 | -49.2086467 | -3605.1265 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0366_20231221_215538_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0366_20231221_215538_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 7120.3 | 7.7458 | 229 | 2023-12-21T21:55:23 | 57.28130595 | -49.0191560 | 108.71 | 3596.7546 | 2023-12-21T22:25:12 | 57.25254460 | -48.9152684 | 99.05 | 3590.7449 | 2023-12-21T21:55:23 | 57.28130595 | -49.0191560 | -3596.7546 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0367_20231221_222537_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0367_20231221_222537_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 3552.2 | 3.8741 | 236 | 2023-12-21T22:25:24 | 57.25253235 | -48.9154871 | 87.56 | 3592.7991 | 2023-12-21T22:55:08 | 57.24706845 | -48.9634576 | 265.38 | 3600.4675 | 2023-12-21T22:25:24 | 57.25253235 | -48.9154871 | -3592.7991 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0368_20231221_225541_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0368_20231221_225541_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 9189.5 | 10.0353 | 222 | 2023-12-21T22:55:24 | 57.24688480 | -48.9662684 | 264.23 | 3594.5425 | 2023-12-21T23:25:06 | 57.24362450 | -49.1169152 | 281.01 | 3610.8679 | 2023-12-21T22:55:24 | 57.24688480 | -48.9662684 | -3594.5425 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0369_20231221_232538_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0369_20231221_232538_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 7982.2 | 8.6707 | 224 | 2023-12-21T23:25:23 | 57.24387470 | -49.1196184 | 283.66 | 3608.2410 | 2023-12-21T23:55:14 | 57.25670405 | -49.2496860 | 282.79 | 3603.1343 | 2023-12-21T23:25:23 | 57.24387470 | -49.1196184 | -3608.2410 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0370_20231221_235547_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0370_20231221_235547_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.598 | 7626.5 | 8.3564 | 222 | 2023-12-21T23:55:31 | 57.25694110 | -49.2520613 | 283.82 | 3604.4595 | 2023-12-22T00:25:07 | 57.26907115 | -49.3763997 | 283.79 | 3606.5088 | 2023-12-21T23:55:31 | 57.25694110 | -49.2520613 | -3604.4595 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0371_20231222_002539_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0371_20231222_002539_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.862 | 7432.2 | 8.0724 | 236 | 2023-12-22T00:25:23 | 57.26926320 | -49.3786224 | 282.80 | 3603.4919 | 2023-12-22T00:55:14 | 57.28105190 | -49.4998413 | 285.33 | 3610.4189 | 2023-12-22T00:25:23 | 57.26926320 | -49.3786224 | -3603.4919 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0372_20231222_005544_MerianEM122.all | application/octet-stream | 17.7 MBytes | 0372_20231222_005544_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.802 | 5207.4 | 5.6669 | 179 | 2023-12-22T00:55:29 | 57.28124115 | -49.5019001 | 286.51 | 3615.6023 | 2023-12-22T01:25:17 | 57.28941500 | -49.5867149 | 295.86 | 3609.3838 | 2023-12-22T00:55:29 | 57.28124115 | -49.5019001 | -3615.6023 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0373_20231222_012534_MerianEM122.all | application/octet-stream | 4.7 MBytes | 0373_20231222_012534_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 7.620 | 1277.0 | 5.4345 | 46 | 2023-12-22T01:25:27 | 57.28951770 | -49.5874224 | 295.35 | 3614.2778 | 2023-12-22T01:33:04 | 57.29161055 | -49.6082298 | 289.28 | 3615.1111 | 2023-12-22T01:25:27 | 57.28951770 | -49.5874224 | -3614.2778 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0374_20231222_034230_MerianEM122.all | application/octet-stream | 21 MBytes | 0374_20231222_034230_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.760 | 6618.1 | 7.2125 | 251 | 2023-12-22T03:42:16 | 57.33136920 | -50.0169554 | 284.45 | 3611.2266 | 2023-12-22T04:12:02 | 57.34200785 | -50.1250211 | 283.54 | 3609.5811 | 2023-12-22T03:42:16 | 57.33136920 | -50.0169554 | -3611.2266 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0375_20231222_041233_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0375_20231222_041233_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.664 | 6993.2 | 7.6452 | 225 | 2023-12-22T04:12:17 | 57.34219995 | -50.1271711 | 285.37 | 3612.9158 | 2023-12-22T04:41:57 | 57.35332740 | -50.2414283 | 286.87 | 3617.1929 | 2023-12-22T04:12:17 | 57.34219995 | -50.1271711 | -3612.9158 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0376_20231222_044224_MerianEM122.all | application/octet-stream | 20.7 MBytes | 0376_20231222_044224_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 6780.5 | 7.3655 | 237 | 2023-12-22T04:42:10 | 57.35353485 | -50.2431206 | 286.92 | 3616.1724 | 2023-12-22T05:12:02 | 57.36424800 | -50.3539453 | 282.19 | 3625.3003 | 2023-12-22T04:42:10 | 57.35353485 | -50.2431206 | -3616.1724 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0377_20231222_051233_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0377_20231222_051233_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.478 | 6661.5 | 7.3287 | 219 | 2023-12-22T05:12:17 | 57.36437615 | -50.3559820 | 285.43 | 3617.5215 | 2023-12-22T05:41:46 | 57.37495515 | -50.4648313 | 291.19 | 3620.6643 | 2023-12-22T05:12:17 | 57.36437615 | -50.3559820 | -3617.5215 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0378_20231222_054224_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0378_20231222_054224_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.904 | 5953.1 | 6.4560 | 252 | 2023-12-22T05:42:12 | 57.37516960 | -50.4667468 | 289.45 | 3618.1631 | 2023-12-22T06:12:06 | 57.38485255 | -50.5639106 | 285.19 | 3617.1479 | 2023-12-22T05:42:12 | 57.37516960 | -50.4667468 | -3618.1631 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0379_20231222_061235_MerianEM122.all | application/octet-stream | 20.9 MBytes | 0379_20231222_061235_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 5774.9 | 6.3062 | 267 | 2023-12-22T06:12:20 | 57.38503345 | -50.5655772 | 286.37 | 3616.2751 | 2023-12-22T06:42:02 | 57.39397775 | -50.6599836 | 289.27 | 3624.7134 | 2023-12-22T06:12:20 | 57.38503345 | -50.5655772 | -3616.2751 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0380_20231222_064223_MerianEM122.all | application/octet-stream | 21.2 MBytes | 0380_20231222_064223_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.664 | 6039.3 | 6.6032 | 265 | 2023-12-22T06:42:23 | 57.39412215 | -50.6611854 | 289.74 | 3629.3052 | 2023-12-22T07:12:03 | 57.40378645 | -50.7599042 | 284.48 | 3671.2964 | 2023-12-22T06:42:23 | 57.39412215 | -50.6611854 | -3629.3052 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0381_20231222_071235_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0381_20231222_071235_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.724 | 6650.0 | 7.2562 | 215 | 2023-12-22T07:12:19 | 57.40392100 | -50.7616241 | 282.97 | 3671.0322 | 2023-12-22T07:42:03 | 57.41445950 | -50.8704467 | 285.64 | 3546.4128 | 2023-12-22T07:12:19 | 57.40392100 | -50.7616241 | -3671.0322 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0382_20231222_074238_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0382_20231222_074238_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.496 | 3182.6 | 3.4994 | 214 | 2023-12-22T07:42:21 | 57.41464845 | -50.8725009 | 281.21 | 3545.3044 | 2023-12-22T08:11:50 | 57.42012660 | -50.9235450 | 348.16 | 3528.2300 | 2023-12-22T07:42:21 | 57.41464845 | -50.8725009 | -3545.3044 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0383_20231222_081226_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0383_20231222_081226_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 117.0 | 0.1271 | 219 | 2023-12-22T08:12:08 | 57.42012150 | -50.9235520 | 347.48 | 3531.2256 | 2023-12-22T08:41:59 | 57.42012395 | -50.9236727 | 0.45 | 3532.0840 | 2023-12-22T08:12:08 | 57.42012150 | -50.9235520 | -3531.2256 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0384_20231222_084234_MerianEM122.all | application/octet-stream | 8.6 MBytes | 0384_20231222_084234_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 12.120 | 138.8 | 0.3715 | 105 | 2023-12-22T08:42:16 | 57.42009805 | -50.9236594 | 4.34 | 3531.0781 | 2023-12-22T08:54:23 | 57.42018595 | -50.9255720 | 348.76 | 3532.6770 | 2023-12-22T08:42:16 | 57.42009805 | -50.9236594 | -3531.0781 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0385_20231222_130120_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0385_20231222_130120_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.550 | 7527.2 | 8.2606 | 215 | 2023-12-22T13:01:11 | 57.42493630 | -50.9437609 | 291.76 | 3526.9587 | 2023-12-22T13:30:44 | 57.43592645 | -51.0671661 | 281.31 | 3514.6135 | 2023-12-22T13:01:11 | 57.42493630 | -50.9437609 | -3526.9587 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0386_20231222_133116_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0386_20231222_133116_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.640 | 7802.3 | 8.5380 | 212 | 2023-12-22T13:31:00 | 57.43615445 | -51.0694940 | 282.35 | 3514.7756 | 2023-12-22T14:00:39 | 57.44935135 | -51.1970229 | 282.05 | 3507.3623 | 2023-12-22T13:31:00 | 57.43615445 | -51.0694940 | -3514.7756 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0387_20231222_140113_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0387_20231222_140113_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 7585.2 | 8.2507 | 222 | 2023-12-22T14:00:56 | 57.44964715 | -51.1995965 | 284.31 | 3507.0364 | 2023-12-22T14:30:45 | 57.46233070 | -51.3236805 | 281.63 | 3511.4377 | 2023-12-22T14:00:56 | 57.44964715 | -51.1995965 | -3507.0364 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0388_20231222_143117_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0388_20231222_143117_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 7468.0 | 8.1449 | 215 | 2023-12-22T14:31:01 | 57.46255990 | -51.3259889 | 283.40 | 3517.0662 | 2023-12-22T15:00:45 | 57.47537255 | -51.4480814 | 281.28 | 3513.4355 | 2023-12-22T14:31:01 | 57.46255990 | -51.3259889 | -3517.0662 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0389_20231222_150119_MerianEM122.all | application/octet-stream | 7.7 MBytes | 0389_20231222_150119_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 10.914 | 2415.5 | 7.1764 | 88 | 2023-12-22T15:01:02 | 57.47556485 | -51.4505642 | 279.08 | 3513.2498 | 2023-12-22T15:11:57 | 57.48545610 | -51.4552034 | 93.82 | 3515.7910 | 2023-12-22T15:01:02 | 57.47556485 | -51.4505642 | -3513.2498 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0390_20231222_152141_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0390_20231222_152141_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 6323.7 | 6.8836 | 224 | 2023-12-22T15:21:24 | 57.48141925 | -51.4103335 | 95.16 | 3513.2329 | 2023-12-22T15:51:12 | 57.47484225 | -51.3146687 | 320.76 | 3491.1851 | 2023-12-22T15:21:24 | 57.48141925 | -51.4103335 | -3513.2329 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0391_20231222_155140_MerianEM122.all | application/octet-stream | 6.1 MBytes | 0391_20231222_155140_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 8.460 | 166.2 | 0.6373 | 79 | 2023-12-22T15:51:27 | 57.47477220 | -51.3150119 | 322.16 | 3513.6841 | 2023-12-22T15:59:54 | 57.47431360 | -51.3169570 | 333.36 | 3508.3208 | 2023-12-22T15:51:27 | 57.47477220 | -51.3150119 | -3513.6841 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0392_20231222_191654_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0392_20231222_191654_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 7337.3 | 8.0177 | 235 | 2023-12-22T19:16:42 | 57.47312305 | -51.3281607 | 319.63 | 3509.3406 | 2023-12-22T19:46:23 | 57.48432160 | -51.4475500 | 286.22 | 3510.6326 | 2023-12-22T19:16:42 | 57.47312305 | -51.3281607 | -3509.3406 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0393_20231222_194652_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0393_20231222_194652_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 7113.6 | 7.7283 | 235 | 2023-12-22T19:46:38 | 57.48443080 | -51.4491481 | 287.98 | 3510.8303 | 2023-12-22T20:16:29 | 57.49356795 | -51.5664478 | 285.21 | 3516.2393 | 2023-12-22T19:46:38 | 57.48443080 | -51.4491481 | -3510.8303 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0394_20231222_201653_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0394_20231222_201653_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.712 | 7322.8 | 7.9927 | 231 | 2023-12-22T20:16:41 | 57.49368895 | -51.5679583 | 287.18 | 3515.5107 | 2023-12-22T20:46:24 | 57.50268590 | -51.6888124 | 285.38 | 3525.0559 | 2023-12-22T20:16:41 | 57.49368895 | -51.5679583 | -3515.5107 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0395_20231222_204654_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0395_20231222_204654_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.592 | 7166.8 | 7.8540 | 240 | 2023-12-22T20:46:54 | 57.50276260 | -51.6906773 | 283.45 | 3525.4883 | 2023-12-22T21:16:30 | 57.51188995 | -51.8089231 | 286.13 | 3531.2705 | 2023-12-22T20:46:54 | 57.50276260 | -51.6906773 | -3525.4883 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0396_20231222_211659_MerianEM122.all | application/octet-stream | 10 MBytes | 0396_20231222_211659_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 14.478 | 2635.7 | 5.9045 | 116 | 2023-12-22T21:16:44 | 57.51210460 | -51.8111132 | 284.45 | 3529.2810 | 2023-12-22T21:31:13 | 57.51680580 | -51.8498794 | 359.85 | 3532.6379 | 2023-12-22T21:16:44 | 57.51210460 | -51.8111132 | -3529.2810 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0397_20231223_034343_MerianEM122.all | application/octet-stream | 19.9 MBytes | 0397_20231223_034343_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.724 | 5684.5 | 6.2023 | 215 | 2023-12-23T03:43:26 | 57.49931300 | -51.8585050 | 194.95 | 3524.5247 | 2023-12-23T04:13:09 | 57.44992920 | -51.8808916 | 211.73 | 3516.5356 | 2023-12-23T03:43:26 | 57.49931300 | -51.8585050 | -3524.5247 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0398_20231223_041335_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0398_20231223_041335_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.838 | 6055.8 | 6.5821 | 224 | 2023-12-23T04:13:22 | 57.44936665 | -51.8814249 | 212.71 | 3515.9675 | 2023-12-23T04:43:12 | 57.39658995 | -51.9039606 | 199.36 | 3528.0776 | 2023-12-23T04:13:22 | 57.44936665 | -51.8814249 | -3515.9675 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0399_20231223_044345_MerianEM122.all | application/octet-stream | 19.4 MBytes | 0399_20231223_044345_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.616 | 5959.9 | 6.5268 | 201 | 2023-12-23T04:43:29 | 57.39556280 | -51.9043345 | 195.46 | 3528.8435 | 2023-12-23T05:13:06 | 57.34386840 | -51.9282105 | 199.97 | 3538.0735 | 2023-12-23T04:43:29 | 57.39556280 | -51.9043345 | -3528.8435 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0400_20231223_051336_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0400_20231223_051336_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 30.012 | 5954.0 | 6.4341 | 223 | 2023-12-23T05:13:21 | 57.34300325 | -51.9287737 | 197.19 | 3543.0259 | 2023-12-23T05:43:22 | 57.29123030 | -51.9519798 | 192.84 | 3546.3777 | 2023-12-23T05:13:21 | 57.34300325 | -51.9287737 | -3543.0259 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0401_20231223_054348_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0401_20231223_054348_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.586 | 5568.1 | 6.1040 | 228 | 2023-12-23T05:43:35 | 57.29041255 | -51.9523613 | 191.70 | 3544.5269 | 2023-12-23T06:13:10 | 57.24203605 | -51.9740053 | 198.15 | 3528.0088 | 2023-12-23T05:43:35 | 57.29041255 | -51.9523613 | -3544.5269 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0402_20231223_061342_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0402_20231223_061342_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.694 | 5618.1 | 6.1362 | 220 | 2023-12-23T06:13:26 | 57.24113030 | -51.9744632 | 194.83 | 3524.9590 | 2023-12-23T06:43:08 | 57.19227055 | -51.9958863 | 196.53 | 3518.4199 | 2023-12-23T06:13:26 | 57.24113030 | -51.9744632 | -3524.9590 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0403_20231223_064337_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0403_20231223_064337_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 5665.3 | 6.1587 | 230 | 2023-12-23T06:43:22 | 57.19143725 | -51.9962787 | 195.76 | 3519.1418 | 2023-12-23T07:13:12 | 57.14202445 | -52.0171387 | 191.52 | 3524.5054 | 2023-12-23T06:43:22 | 57.19143725 | -51.9962787 | -3519.1418 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0404_20231223_071340_MerianEM122.all | application/octet-stream | 19.9 MBytes | 0404_20231223_071340_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 5617.3 | 6.1264 | 217 | 2023-12-23T07:13:26 | 57.14123780 | -52.0173723 | 196.22 | 3526.6758 | 2023-12-23T07:43:10 | 57.09258985 | -52.0410599 | 198.72 | 3523.7534 | 2023-12-23T07:13:26 | 57.14123780 | -52.0173723 | -3526.6758 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0405_20231223_074344_MerianEM122.all | application/octet-stream | 19.9 MBytes | 0405_20231223_074344_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 5438.2 | 5.9085 | 212 | 2023-12-23T07:43:27 | 57.09162675 | -52.0414387 | 194.50 | 3612.0392 | 2023-12-23T08:13:18 | 57.04437400 | -52.0624720 | 191.07 | 3522.3784 | 2023-12-23T07:43:27 | 57.09162675 | -52.0414387 | -3612.0392 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0406_20231223_081344_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0406_20231223_081344_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.604 | 6402.6 | 7.0139 | 215 | 2023-12-23T08:13:31 | 57.04363400 | -52.0626561 | 191.98 | 3520.3918 | 2023-12-23T08:43:08 | 56.98759565 | -52.0849716 | 201.79 | 3523.5125 | 2023-12-23T08:13:31 | 57.04363400 | -52.0626561 | -3520.3918 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0407_20231223_084339_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0407_20231223_084339_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 6416.3 | 7.0114 | 223 | 2023-12-23T08:43:23 | 56.98658650 | -52.0854930 | 201.84 | 3527.1714 | 2023-12-23T09:13:04 | 56.93070285 | -52.1108729 | 201.52 | 3526.1257 | 2023-12-23T08:43:23 | 56.98658650 | -52.0854930 | -3527.1714 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0408_20231223_091336_MerianEM122.all | application/octet-stream | 19.9 MBytes | 0408_20231223_091336_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 5895.9 | 6.4008 | 206 | 2023-12-23T09:13:19 | 56.92973485 | -52.1113578 | 200.74 | 3527.4463 | 2023-12-23T09:43:12 | 56.88074950 | -52.1355749 | 19.44 | 3524.1880 | 2023-12-23T09:13:19 | 56.92973485 | -52.1113578 | -3527.4463 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0409_20231223_094339_MerianEM122.all | application/octet-stream | 5.8 MBytes | 0409_20231223_094339_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 8.046 | 355.0 | 1.4314 | 72 | 2023-12-23T09:43:26 | 56.88103540 | -52.1352834 | 23.22 | 3522.1858 | 2023-12-23T09:51:28 | 56.88310215 | -52.1334552 | 352.21 | 3523.6663 | 2023-12-23T09:43:26 | 56.88103540 | -52.1352834 | -3522.1858 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0410_20231223_124527_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0410_20231223_124527_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.628 | 6947.9 | 7.6052 | 215 | 2023-12-23T12:45:10 | 56.88656175 | -52.1245659 | 269.67 | 3526.5862 | 2023-12-23T13:14:48 | 56.89035760 | -52.2379143 | 278.81 | 3521.0005 | 2023-12-23T12:45:10 | 56.88656175 | -52.1245659 | -3526.5862 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0411_20231223_131523_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0411_20231223_131523_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.802 | 6795.6 | 7.3959 | 214 | 2023-12-23T13:15:06 | 56.89049665 | -52.2401104 | 278.32 | 3520.3218 | 2023-12-23T13:44:54 | 56.89800630 | -52.3507194 | 276.89 | 3505.4426 | 2023-12-23T13:15:06 | 56.89049665 | -52.2401104 | -3520.3218 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0412_20231223_134527_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0412_20231223_134527_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 7031.9 | 7.6577 | 211 | 2023-12-23T13:45:11 | 56.89815215 | -52.3528551 | 278.53 | 3513.9783 | 2023-12-23T14:14:58 | 56.90691275 | -52.4670936 | 276.94 | 3497.1438 | 2023-12-23T13:45:11 | 56.89815215 | -52.3528551 | -3513.9783 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0413_20231223_141531_MerianEM122.all | application/octet-stream | 10.8 MBytes | 0413_20231223_141531_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 15.654 | 1641.9 | 3.4015 | 115 | 2023-12-23T14:15:14 | 56.90711030 | -52.4693739 | 278.40 | 3501.3494 | 2023-12-23T14:30:54 | 56.91072290 | -52.4944510 | 299.59 | 3496.6685 | 2023-12-23T14:15:14 | 56.90711030 | -52.4693739 | -3501.3494 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0414_20231223_165851_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0414_20231223_165851_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.754 | 3511.9 | 3.8280 | 221 | 2023-12-23T16:58:37 | 56.91558550 | -52.4953467 | 69.65 | 3490.9663 | 2023-12-23T17:28:22 | 56.92359375 | -52.4397109 | 75.79 | 3499.1863 | 2023-12-23T16:58:37 | 56.91558550 | -52.4953467 | -3490.9663 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0415_20231223_172856_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0415_20231223_172856_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.628 | 4478.0 | 4.9024 | 207 | 2023-12-23T17:28:39 | 56.92376570 | -52.4383331 | 75.11 | 3504.1465 | 2023-12-23T17:58:16 | 56.93383720 | -52.3671971 | 72.00 | 3509.1506 | 2023-12-23T17:28:39 | 56.92376570 | -52.4383331 | -3504.1465 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0416_20231223_175852_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0416_20231223_175852_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.634 | 4618.8 | 5.0549 | 208 | 2023-12-23T17:58:34 | 56.93404780 | -52.3657001 | 73.16 | 3506.8269 | 2023-12-23T18:28:12 | 56.94442910 | -52.2922703 | 72.25 | 3512.0327 | 2023-12-23T17:58:34 | 56.93404780 | -52.3657001 | -3506.8269 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0417_20231223_182846_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0417_20231223_182846_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.844 | 4532.9 | 4.9256 | 208 | 2023-12-23T18:28:29 | 56.94466515 | -52.2907921 | 71.54 | 3512.3650 | 2023-12-23T18:58:20 | 56.95487510 | -52.2187538 | 70.22 | 3517.9705 | 2023-12-23T18:28:29 | 56.94466515 | -52.2907921 | -3512.3650 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0418_20231223_185855_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0418_20231223_185855_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.658 | 4568.1 | 4.9955 | 205 | 2023-12-23T18:58:38 | 56.95507695 | -52.2174088 | 70.70 | 3514.0759 | 2023-12-23T19:28:17 | 56.96529160 | -52.1447201 | 71.62 | 3526.6206 | 2023-12-23T18:58:38 | 56.95507695 | -52.2174088 | -3514.0759 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0419_20231223_192852_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0419_20231223_192852_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.622 | 4476.5 | 4.9015 | 206 | 2023-12-23T19:28:34 | 56.96543350 | -52.1432904 | 71.58 | 3527.3396 | 2023-12-23T19:58:12 | 56.97551900 | -52.0720777 | 70.26 | 3529.8567 | 2023-12-23T19:28:34 | 56.96543350 | -52.1432904 | -3527.3396 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0420_20231223_195846_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0420_20231223_195846_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 4796.3 | 5.2178 | 205 | 2023-12-23T19:58:29 | 56.97571810 | -52.0706459 | 69.87 | 3525.4990 | 2023-12-23T20:28:17 | 56.98652240 | -51.9943426 | 69.68 | 3532.0505 | 2023-12-23T19:58:29 | 56.97571810 | -52.0706459 | -3525.4990 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0421_20231223_202853_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0421_20231223_202853_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.664 | 4674.5 | 5.1111 | 204 | 2023-12-23T20:28:35 | 56.98670510 | -51.9927686 | 68.81 | 3531.2112 | 2023-12-23T20:58:15 | 56.99724590 | -51.9183902 | 62.79 | 3534.2549 | 2023-12-23T20:28:35 | 56.98670510 | -51.9927686 | -3531.2112 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0422_20231223_205850_MerianEM122.all | application/octet-stream | 6.4 MBytes | 0422_20231223_205850_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 9.168 | 1098.0 | 3.8851 | 63 | 2023-12-23T20:58:32 | 56.99738540 | -51.9173999 | 62.51 | 3536.1948 | 2023-12-23T21:07:42 | 57.00006300 | -51.9000300 | 80.90 | 3536.1396 | 2023-12-23T20:58:32 | 56.99738540 | -51.9173999 | -3536.1948 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0423_20231223_224824_MerianEM122.all | application/octet-stream | 827 kBytes | 0423_20231223_224824_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 0.894 | 2.0 | 0.0723 | 8 | 2023-12-23T22:48:07 | 56.99992835 | -51.8984781 | 74.92 | 3534.8623 | 2023-12-23T22:49:00 | 56.99993970 | -51.8984627 | 75.75 | 3536.3892 | 2023-12-23T22:48:07 | 56.99992835 | -51.8984781 | -3534.8623 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0424_20231223_233426_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0424_20231223_233426_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.730 | 8398.1 | 9.1615 | 216 | 2023-12-23T23:34:11 | 57.00043880 | -51.8981600 | 221.88 | 3537.0610 | 2023-12-24T00:03:55 | 56.94770285 | -51.9966970 | 227.14 | 3543.5403 | 2023-12-23T23:34:11 | 57.00043880 | -51.8981600 | -3537.0610 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0425_20231224_000430_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0425_20231224_000430_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.838 | 8924.9 | 9.7011 | 208 | 2023-12-24T00:04:12 | 56.94658060 | -51.9988307 | 225.08 | 3532.5757 | 2023-12-24T00:34:02 | 56.89038480 | -52.1032791 | 224.62 | 3527.2617 | 2023-12-24T00:04:12 | 56.94658060 | -51.9988307 | -3532.5757 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0426_20231224_003435_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0426_20231224_003435_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.520 | 8522.9 | 9.3636 | 204 | 2023-12-24T00:34:18 | 56.88934480 | -52.1052074 | 226.51 | 3527.7673 | 2023-12-24T01:03:50 | 56.83552430 | -52.2044874 | 224.25 | 3523.7336 | 2023-12-24T00:34:18 | 56.88934480 | -52.1052074 | -3527.7673 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0427_20231224_010424_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0427_20231224_010424_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.916 | 8638.1 | 9.3651 | 212 | 2023-12-24T01:04:07 | 56.83446155 | -52.2064448 | 224.92 | 3525.4580 | 2023-12-24T01:34:02 | 56.78052575 | -52.3080290 | 224.88 | 3526.1838 | 2023-12-24T01:04:07 | 56.83446155 | -52.2064448 | -3525.4580 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0428_20231224_013435_MerianEM122.all | application/octet-stream | 20.1 MBytes | 0428_20231224_013435_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.490 | 8471.9 | 9.3171 | 206 | 2023-12-24T01:34:19 | 56.77957775 | -52.3100405 | 224.56 | 3525.8831 | 2023-12-24T02:03:48 | 56.72731050 | -52.4106323 | 224.53 | 3516.7004 | 2023-12-24T01:34:19 | 56.77957775 | -52.3100405 | -3525.8831 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0429_20231224_020421_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0429_20231224_020421_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.910 | 8631.4 | 9.3594 | 212 | 2023-12-24T02:04:05 | 56.72631780 | -52.4125216 | 224.84 | 3515.1987 | 2023-12-24T02:33:59 | 56.67320350 | -52.5150546 | 222.41 | 3511.7654 | 2023-12-24T02:04:05 | 56.72631780 | -52.4125216 | -3515.1987 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0430_20231224_023434_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0430_20231224_023434_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 8190.4 | 8.9487 | 210 | 2023-12-24T02:34:16 | 56.67215395 | -52.5170482 | 223.81 | 3511.4924 | 2023-12-24T03:03:58 | 56.62182675 | -52.6143106 | 220.16 | 3500.4590 | 2023-12-24T02:34:16 | 56.67215395 | -52.5170482 | -3511.4924 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0431_20231224_030433_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0431_20231224_030433_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.544 | 7825.4 | 8.5911 | 206 | 2023-12-24T03:04:15 | 56.62085080 | -52.6162007 | 220.48 | 3503.3555 | 2023-12-24T03:33:47 | 56.57262335 | -52.7087103 | 220.21 | 3483.4836 | 2023-12-24T03:04:15 | 56.62085080 | -52.6162007 | -3503.3555 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0432_20231224_033421_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0432_20231224_033421_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 7895.4 | 8.6106 | 207 | 2023-12-24T03:34:04 | 56.57163375 | -52.7105883 | 219.35 | 3482.4998 | 2023-12-24T04:03:49 | 56.52304450 | -52.8039631 | 225.17 | 3477.0525 | 2023-12-24T03:34:04 | 56.57163375 | -52.7105883 | -3482.4998 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0433_20231224_040424_MerianEM122.all | application/octet-stream | 20.3 MBytes | 0433_20231224_040424_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.712 | 7632.8 | 8.3321 | 207 | 2023-12-24T04:04:06 | 56.52219190 | -52.8056474 | 219.74 | 3477.5667 | 2023-12-24T04:33:49 | 56.47520015 | -52.8957235 | 217.49 | 3466.7024 | 2023-12-24T04:04:06 | 56.52219190 | -52.8056474 | -3477.5667 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0434_20231224_043424_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0434_20231224_043424_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 7765.2 | 8.4425 | 213 | 2023-12-24T04:34:06 | 56.47423640 | -52.8973279 | 219.59 | 3474.5974 | 2023-12-24T05:03:56 | 56.42656465 | -52.9890968 | 223.68 | 3471.9854 | 2023-12-24T04:34:06 | 56.47423640 | -52.8973279 | -3474.5974 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0435_20231224_050430_MerianEM122.all | application/octet-stream | 20.2 MBytes | 0435_20231224_050430_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.586 | 7938.4 | 8.7015 | 210 | 2023-12-24T05:04:13 | 56.42551880 | -52.9909775 | 222.26 | 3470.6060 | 2023-12-24T05:33:48 | 56.37664895 | -53.0844369 | 225.76 | 3477.4785 | 2023-12-24T05:04:13 | 56.42551880 | -52.9909775 | -3470.6060 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0436_20231224_053421_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0436_20231224_053421_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.754 | 7733.6 | 8.4305 | 213 | 2023-12-24T05:34:04 | 56.37566810 | -53.0862589 | 226.12 | 3477.1694 | 2023-12-24T06:03:50 | 56.32798605 | -53.1771123 | 224.47 | 3470.9875 | 2023-12-24T05:34:04 | 56.37566810 | -53.0862589 | -3477.1694 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0437_20231224_060422_MerianEM122.all | application/octet-stream | 20.4 MBytes | 0437_20231224_060422_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.724 | 8113.5 | 8.8520 | 213 | 2023-12-24T06:04:06 | 56.32713820 | -53.1788473 | 228.65 | 3469.9573 | 2023-12-24T06:33:49 | 56.27721330 | -53.2741805 | 225.50 | 3451.0068 | 2023-12-24T06:04:06 | 56.32713820 | -53.1788473 | -3469.9573 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0438_20231224_063423_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0438_20231224_063423_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 8206.3 | 8.9098 | 214 | 2023-12-24T06:34:06 | 56.27618645 | -53.2762191 | 225.07 | 3449.9512 | 2023-12-24T07:03:58 | 56.22569425 | -53.3725592 | 224.75 | 3422.7683 | 2023-12-24T06:34:06 | 56.27618645 | -53.2762191 | -3449.9512 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0439_20231224_070431_MerianEM122.all | application/octet-stream | 20.6 MBytes | 0439_20231224_070431_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.748 | 8533.9 | 9.3044 | 218 | 2023-12-24T07:04:15 | 56.22465565 | -53.3745174 | 225.27 | 3423.7930 | 2023-12-24T07:33:59 | 56.17208420 | -53.4745014 | 226.82 | 3345.6731 | 2023-12-24T07:04:15 | 56.22465565 | -53.3745174 | -3423.7930 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0440_20231224_073433_MerianEM122.all | application/octet-stream | 20.5 MBytes | 0440_20231224_073433_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.556 | 8532.1 | 9.3630 | 215 | 2023-12-24T07:34:16 | 56.17109030 | -53.4764233 | 226.06 | 3350.0361 | 2023-12-24T08:03:49 | 56.11851210 | -53.5761941 | 230.39 | 3262.8704 | 2023-12-24T07:34:16 | 56.17109030 | -53.4764233 | -3350.0361 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0441_20231224_080422_MerianEM122.all | application/octet-stream | 20.8 MBytes | 0441_20231224_080422_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.838 | 8875.6 | 9.6480 | 219 | 2023-12-24T08:04:06 | 56.11750600 | -53.5782265 | 230.07 | 3260.7993 | 2023-12-24T08:33:56 | 56.06282420 | -53.6819112 | 229.43 | 3197.1685 | 2023-12-24T08:04:06 | 56.11750600 | -53.5782265 | -3260.7993 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0442_20231224_083428_MerianEM122.all | application/octet-stream | 21.1 MBytes | 0442_20231224_083428_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.862 | 8558.9 | 9.2958 | 225 | 2023-12-24T08:34:12 | 56.06186030 | -53.6838405 | 228.60 | 3200.9600 | 2023-12-24T09:04:04 | 56.00916195 | -53.7836678 | 225.45 | 3139.5925 | 2023-12-24T08:34:12 | 56.06186030 | -53.6838405 | -3200.9600 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0443_20231224_090433_MerianEM122.all | application/octet-stream | 22.1 MBytes | 0443_20231224_090433_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.766 | 8571.9 | 9.3405 | 246 | 2023-12-24T09:04:18 | 56.00833845 | -53.7852344 | 226.90 | 3142.9612 | 2023-12-24T09:34:04 | 55.95557200 | -53.8851177 | 231.41 | 3091.5027 | 2023-12-24T09:04:18 | 56.00833845 | -53.7852344 | -3142.9612 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0444_20231224_093433_MerianEM122.all | application/octet-stream | 21.8 MBytes | 0444_20231224_093433_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.580 | 8910.2 | 9.7685 | 244 | 2023-12-24T09:34:19 | 55.95473300 | -53.8868588 | 227.61 | 3096.6704 | 2023-12-24T10:03:54 | 55.89982805 | -53.9905060 | 225.96 | 3041.1284 | 2023-12-24T09:34:19 | 55.95473300 | -53.8868588 | -3096.6704 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0445_20231224_100423_MerianEM122.all | application/octet-stream | 21.8 MBytes | 0445_20231224_100423_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.790 | 8928.1 | 9.7194 | 244 | 2023-12-24T10:04:08 | 55.89891710 | -53.9921340 | 225.87 | 3035.4893 | 2023-12-24T10:33:56 | 55.84392180 | -54.0958811 | 229.72 | 2985.5754 | 2023-12-24T10:04:08 | 55.89891710 | -53.9921340 | -3035.4893 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0446_20231224_103425_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0446_20231224_103425_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 8903.3 | 9.6957 | 245 | 2023-12-24T10:34:10 | 55.84300885 | -54.0976251 | 228.72 | 2985.3120 | 2023-12-24T11:03:57 | 55.78814375 | -54.2009046 | 228.11 | 2953.6672 | 2023-12-24T10:34:10 | 55.84300885 | -54.0976251 | -2985.3120 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0447_20231224_110426_MerianEM122.all | application/octet-stream | 21.7 MBytes | 0447_20231224_110426_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 8655.1 | 9.4098 | 247 | 2023-12-24T11:04:11 | 55.78723945 | -54.2025873 | 229.38 | 2952.9055 | 2023-12-24T11:34:01 | 55.73403385 | -54.3030469 | 229.16 | 2908.1370 | 2023-12-24T11:04:11 | 55.78723945 | -54.2025873 | -2952.9055 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0448_20231224_113430_MerianEM122.all | application/octet-stream | 21.4 MBytes | 0448_20231224_113430_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.616 | 8702.0 | 9.5304 | 243 | 2023-12-24T11:34:15 | 55.73317950 | -54.3046564 | 230.09 | 2906.6365 | 2023-12-24T12:03:52 | 55.67955125 | -54.4052443 | 230.24 | 2838.5481 | 2023-12-24T11:34:15 | 55.73317950 | -54.3046564 | -2906.6365 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0449_20231224_120421_MerianEM122.all | application/octet-stream | 19.1 MBytes | 0449_20231224_120421_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 26.094 | 5722.1 | 7.1125 | 217 | 2023-12-24T12:04:06 | 55.67865520 | -54.4069632 | 229.77 | 2840.1445 | 2023-12-24T12:30:12 | 55.64666285 | -54.4749667 | 280.11 | 2831.7876 | 2023-12-24T12:04:06 | 55.67865520 | -54.4069632 | -2840.1445 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0450_20231224_170424_MerianEM122.all | application/octet-stream | 3.3 MBytes | 0450_20231224_170424_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 4.320 | 754.0 | 5.6602 | 44 | 2023-12-24T17:04:10 | 55.64309700 | -54.4765544 | 254.49 | 2828.2810 | 2023-12-24T17:08:29 | 55.63648575 | -54.4783485 | 178.27 | 2813.5566 | 2023-12-24T17:04:10 | 55.64309700 | -54.4765544 | -2828.2810 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0000_20231224_171010_MerianEM122.all | application/octet-stream | 22 MBytes | 0000_20231224_171010_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.790 | 9492.0 | 10.3335 | 255 | 2023-12-24T17:10:03 | 55.63194905 | -54.4763029 | 151.93 | 2818.6013 | 2023-12-24T17:39:50 | 55.56568125 | -54.3837582 | 127.82 | 2633.9490 | 2023-12-24T17:10:03 | 55.63194905 | -54.4763029 | -2818.6013 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0001_20231224_174018_MerianEM122.all | application/octet-stream | 22.2 MBytes | 0001_20231224_174018_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.814 | 9811.1 | 10.6735 | 262 | 2023-12-24T17:40:04 | 55.56483705 | -54.3818727 | 126.00 | 2640.9436 | 2023-12-24T18:09:53 | 55.50834100 | -54.2626495 | 130.86 | 2596.0474 | 2023-12-24T17:40:04 | 55.56483705 | -54.3818727 | -2640.9436 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0002_20231224_181019_MerianEM122.all | application/octet-stream | 22.1 MBytes | 0002_20231224_181019_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.748 | 9907.1 | 10.8006 | 264 | 2023-12-24T18:10:06 | 55.50746215 | -54.2608782 | 129.91 | 2599.6487 | 2023-12-24T18:39:50 | 55.45043140 | -54.1406566 | 131.74 | 2553.8569 | 2023-12-24T18:10:06 | 55.50746215 | -54.2608782 | -2599.6487 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0003_20231224_184017_MerianEM122.all | application/octet-stream | 23.6 MBytes | 0003_20231224_184017_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.832 | 9728.4 | 10.5757 | 282 | 2023-12-24T18:40:04 | 55.44955115 | -54.1388833 | 128.94 | 2552.5393 | 2023-12-24T19:09:54 | 55.39353610 | -54.0210592 | 135.35 | 2516.7141 | 2023-12-24T18:40:04 | 55.44955115 | -54.1388833 | -2552.5393 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0004_20231224_191020_MerianEM122.all | application/octet-stream | 23.5 MBytes | 0004_20231224_191020_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.670 | 9871.8 | 10.7914 | 276 | 2023-12-24T19:10:07 | 55.39267545 | -54.0193267 | 135.09 | 2518.5969 | 2023-12-24T19:39:47 | 55.33575765 | -53.8999874 | 132.95 | 2394.9390 | 2023-12-24T19:10:07 | 55.39267545 | -54.0193267 | -2518.5969 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0005_20231224_194011_MerianEM122.all | application/octet-stream | 24.4 MBytes | 0005_20231224_194011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.850 | 9861.1 | 10.7142 | 292 | 2023-12-24T19:39:59 | 55.33497865 | -53.8983397 | 133.07 | 2392.5925 | 2023-12-24T20:09:50 | 55.27800825 | -53.7794762 | 131.15 | 2371.2883 | 2023-12-24T19:39:59 | 55.33497865 | -53.8983397 | -2392.5925 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0006_20231224_201016_MerianEM122.all | application/octet-stream | 23.8 MBytes | 0006_20231224_201016_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.730 | 9510.5 | 10.3760 | 282 | 2023-12-24T20:10:03 | 55.27718125 | -53.7776959 | 130.79 | 2368.3140 | 2023-12-24T20:39:47 | 55.22218070 | -53.6632954 | 129.50 | 2244.5046 | 2023-12-24T20:10:03 | 55.27718125 | -53.7776959 | -2368.3140 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0007_20231224_204011_MerianEM122.all | application/octet-stream | 24.5 MBytes | 0007_20231224_204011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.790 | 9695.4 | 10.5556 | 308 | 2023-12-24T20:39:59 | 55.22142250 | -53.6617360 | 128.85 | 2236.2749 | 2023-12-24T21:09:46 | 55.16542575 | -53.5451746 | 123.26 | 2097.2319 | 2023-12-24T20:39:59 | 55.22142250 | -53.6617360 | -2236.2749 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0008_20231224_211008_MerianEM122.all | application/octet-stream | 24.5 MBytes | 0008_20231224_211008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.868 | 9610.8 | 10.4363 | 304 | 2023-12-24T21:09:57 | 55.16476475 | -53.5437054 | 125.67 | 2107.2104 | 2023-12-24T21:39:49 | 55.10925905 | -53.4283311 | 127.43 | 2161.6267 | 2023-12-24T21:09:57 | 55.16476475 | -53.5437054 | -2107.2104 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0009_20231224_214013_MerianEM122.all | application/octet-stream | 24.2 MBytes | 0009_20231224_214013_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.868 | 9550.7 | 10.3700 | 288 | 2023-12-24T21:40:01 | 55.10847615 | -53.4268251 | 125.65 | 2153.6865 | 2023-12-24T22:09:53 | 55.05344475 | -53.3121378 | 124.05 | 2182.5259 | 2023-12-24T21:40:01 | 55.10847615 | -53.4268251 | -2153.6865 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0010_20231224_221018_MerianEM122.all | application/octet-stream | 24.4 MBytes | 0010_20231224_221018_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.712 | 9193.9 | 10.0354 | 308 | 2023-12-24T22:10:05 | 55.05269545 | -53.3105177 | 124.77 | 2184.0591 | 2023-12-24T22:39:48 | 54.99970270 | -53.2002860 | 126.66 | 2061.4729 | 2023-12-24T22:10:05 | 55.05269545 | -53.3105177 | -2184.0591 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0011_20231224_224011_MerianEM122.all | application/octet-stream | 24.6 MBytes | 0011_20231224_224011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.856 | 9246.7 | 10.0442 | 322 | 2023-12-24T22:40:00 | 54.99897850 | -53.1988954 | 128.01 | 2059.4724 | 2023-12-24T23:09:51 | 54.94605290 | -53.0876892 | 125.16 | 1921.0806 | 2023-12-24T22:40:00 | 54.99897850 | -53.1988954 | -2059.4724 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0012_20231224_231012_MerianEM122.all | application/octet-stream | 25.5 MBytes | 0012_20231224_231012_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.784 | 8990.6 | 9.7908 | 344 | 2023-12-24T23:10:02 | 54.94549465 | -53.0863285 | 126.92 | 1921.2615 | 2023-12-24T23:39:49 | 54.89337445 | -52.9792986 | 134.43 | 1677.4573 | 2023-12-24T23:10:02 | 54.94549465 | -53.0863285 | -1921.2615 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0013_20231224_234008_MerianEM122.all | application/octet-stream | 27.4 MBytes | 0013_20231224_234008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.916 | 9023.4 | 9.7832 | 402 | 2023-12-24T23:39:58 | 54.89275325 | -52.9781799 | 130.73 | 1678.6382 | 2023-12-25T00:09:53 | 54.84069575 | -52.8706431 | 127.95 | 1482.8998 | 2023-12-24T23:39:58 | 54.89275325 | -52.9781799 | -1678.6382 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0014_20231225_001009_MerianEM122.all | application/octet-stream | 29.8 MBytes | 0014_20231225_001009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.868 | 8780.0 | 9.5341 | 464 | 2023-12-25T00:10:01 | 54.84022980 | -52.8696785 | 128.25 | 1485.0916 | 2023-12-25T00:39:53 | 54.78957930 | -52.7650516 | 126.64 | 1389.4603 | 2023-12-25T00:10:01 | 54.84022980 | -52.8696785 | -1485.0916 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0015_20231225_004009_MerianEM122.all | application/octet-stream | 30.2 MBytes | 0015_20231225_004009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.934 | 8483.4 | 9.1909 | 464 | 2023-12-25T00:40:01 | 54.78915565 | -52.7641784 | 126.84 | 1388.1838 | 2023-12-25T01:09:57 | 54.74018150 | -52.6632499 | 124.32 | 1507.1625 | 2023-12-25T00:40:01 | 54.78915565 | -52.7641784 | -1388.1838 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0016_20231225_011013_MerianEM122.all | application/octet-stream | 28.6 MBytes | 0016_20231225_011013_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.802 | 8189.3 | 8.9123 | 434 | 2023-12-25T01:10:05 | 54.73977805 | -52.6623690 | 124.15 | 1506.9506 | 2023-12-25T01:39:53 | 54.69256225 | -52.5649740 | 122.11 | 1710.9890 | 2023-12-25T01:10:05 | 54.73977805 | -52.6623690 | -1506.9506 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0017_20231225_014010_MerianEM122.all | application/octet-stream | 27.9 MBytes | 0017_20231225_014010_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.916 | 8229.7 | 8.9227 | 384 | 2023-12-25T01:40:01 | 54.69213275 | -52.5640049 | 122.71 | 1708.0298 | 2023-12-25T02:09:56 | 54.64536455 | -52.4652803 | 121.66 | 1942.6105 | 2023-12-25T01:40:01 | 54.69213275 | -52.5640049 | -1708.0298 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0018_20231225_021016_MerianEM122.all | application/octet-stream | 26.5 MBytes | 0018_20231225_021016_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.838 | 7828.4 | 8.5092 | 350 | 2023-12-25T02:10:06 | 54.64484245 | -52.4641811 | 121.53 | 1943.1649 | 2023-12-25T02:39:56 | 54.59954980 | -52.3715006 | 120.24 | 2230.0500 | 2023-12-25T02:10:06 | 54.64484245 | -52.4641811 | -1943.1649 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0019_20231225_024018_MerianEM122.all | application/octet-stream | 25 MBytes | 0019_20231225_024018_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.700 | 7884.9 | 8.6101 | 332 | 2023-12-25T02:40:07 | 54.59901285 | -52.3703943 | 119.97 | 2230.8208 | 2023-12-25T03:09:49 | 54.55373460 | -52.2766569 | 122.52 | 2325.8972 | 2023-12-25T02:40:07 | 54.59901285 | -52.3703943 | -2230.8208 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0020_20231225_031011_MerianEM122.all | application/octet-stream | 24.7 MBytes | 0020_20231225_031011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.778 | 8079.8 | 8.8007 | 312 | 2023-12-25T03:10:00 | 54.55316395 | -52.2754483 | 121.58 | 2326.5317 | 2023-12-25T03:39:47 | 54.50673545 | -52.1796049 | 127.06 | 2458.0698 | 2023-12-25T03:10:00 | 54.55316395 | -52.2754483 | -2326.5317 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0021_20231225_034011_MerianEM122.all | application/octet-stream | 24.5 MBytes | 0021_20231225_034011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.760 | 8347.7 | 9.0981 | 288 | 2023-12-25T03:39:59 | 54.50605980 | -52.1782781 | 126.45 | 2456.8782 | 2023-12-25T04:09:44 | 54.45800695 | -52.0794867 | 125.26 | 2564.8052 | 2023-12-25T03:39:59 | 54.50605980 | -52.1782781 | -2456.8782 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0022_20231225_041010_MerianEM122.all | application/octet-stream | 23.1 MBytes | 0022_20231225_041010_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.796 | 8258.1 | 8.9886 | 272 | 2023-12-25T04:09:57 | 54.45731205 | -52.0780111 | 124.30 | 2565.4395 | 2023-12-25T04:39:45 | 54.40693415 | -51.9910974 | 177.88 | 2696.2170 | 2023-12-25T04:09:57 | 54.45731205 | -52.0780111 | -2565.4395 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0023_20231225_044013_MerianEM122.all | application/octet-stream | 21.9 MBytes | 0023_20231225_044013_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.772 | 7810.6 | 8.5089 | 254 | 2023-12-25T04:39:59 | 54.40578500 | -51.9910261 | 180.12 | 2705.1440 | 2023-12-25T05:09:45 | 54.33669850 | -52.0113952 | 192.32 | 2658.8135 | 2023-12-25T04:39:59 | 54.40578500 | -51.9910261 | -2705.1440 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0024_20231225_051013_MerianEM122.all | application/octet-stream | 22 MBytes | 0024_20231225_051013_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.736 | 7898.0 | 8.6143 | 257 | 2023-12-25T05:09:59 | 54.33566400 | -52.0117271 | 192.11 | 2661.6812 | 2023-12-25T05:39:43 | 54.26524860 | -52.0259328 | 187.52 | 2683.1143 | 2023-12-25T05:09:59 | 54.33566400 | -52.0117271 | -2661.6812 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0025_20231225_054009_MerianEM122.all | application/octet-stream | 22.2 MBytes | 0025_20231225_054009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.862 | 8172.4 | 8.8766 | 264 | 2023-12-25T05:39:56 | 54.26422550 | -52.0260682 | 188.69 | 2679.3293 | 2023-12-25T06:09:47 | 54.19128365 | -52.0396450 | 189.63 | 2612.8923 | 2023-12-25T05:39:56 | 54.26422550 | -52.0260682 | -2679.3293 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0026_20231225_061014_MerianEM122.all | application/octet-stream | 22.4 MBytes | 0026_20231225_061014_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.772 | 7909.7 | 8.6158 | 272 | 2023-12-25T06:10:00 | 54.19019015 | -52.0398772 | 186.47 | 2611.8750 | 2023-12-25T06:39:47 | 54.12243020 | -52.0704605 | 209.72 | 2526.2422 | 2023-12-25T06:10:00 | 54.19019015 | -52.0398772 | -2611.8750 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0027_20231225_064012_MerianEM122.all | application/octet-stream | 23.5 MBytes | 0027_20231225_064012_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.886 | 7754.0 | 8.4143 | 294 | 2023-12-25T06:39:59 | 54.12150695 | -52.0710847 | 210.34 | 2529.0857 | 2023-12-25T07:09:52 | 54.05840520 | -52.1211006 | 204.56 | 2429.1931 | 2023-12-25T06:39:59 | 54.12150695 | -52.0710847 | -2529.0857 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0028_20231225_071014_MerianEM122.all | application/octet-stream | 24.1 MBytes | 0028_20231225_071014_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.682 | 8299.0 | 9.0672 | 305 | 2023-12-25T07:10:04 | 54.05760340 | -52.1215220 | 201.73 | 2428.1863 | 2023-12-25T07:39:45 | 53.98394565 | -52.1050931 | 171.86 | 2378.9636 | 2023-12-25T07:10:04 | 54.05760340 | -52.1215220 | -2428.1863 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0029_20231225_074007_MerianEM122.all | application/octet-stream | 24.6 MBytes | 0029_20231225_074007_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.940 | 8427.9 | 9.1301 | 318 | 2023-12-25T07:39:56 | 53.98301380 | -52.1048205 | 168.68 | 2381.8777 | 2023-12-25T08:09:52 | 53.90850375 | -52.0825891 | 172.57 | 2284.5054 | 2023-12-25T07:39:56 | 53.98301380 | -52.1048205 | -2381.8777 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0030_20231225_081014_MerianEM122.all | application/octet-stream | 24.9 MBytes | 0030_20231225_081014_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.760 | 8391.1 | 9.1451 | 326 | 2023-12-25T08:10:03 | 53.90762270 | -52.0823708 | 173.30 | 2279.4324 | 2023-12-25T08:39:48 | 53.83275895 | -52.0702664 | 178.53 | 2173.4500 | 2023-12-25T08:10:03 | 53.90762270 | -52.0823708 | -2279.4324 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0031_20231225_084011_MerianEM122.all | application/octet-stream | 25.9 MBytes | 0031_20231225_084011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.874 | 8669.8 | 9.4131 | 347 | 2023-12-25T08:40:00 | 53.83183580 | -52.0701125 | 174.90 | 2170.4026 | 2023-12-25T09:09:52 | 53.75419660 | -52.0608202 | 177.35 | 2056.5061 | 2023-12-25T08:40:00 | 53.83183580 | -52.0701125 | -2170.4026 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0032_20231225_091011_MerianEM122.all | application/octet-stream | 26.8 MBytes | 0032_20231225_091011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.802 | 8806.8 | 9.5834 | 365 | 2023-12-25T09:10:01 | 53.75336510 | -52.0607162 | 179.28 | 2059.8677 | 2023-12-25T09:39:50 | 53.67447195 | -52.0519195 | 173.53 | 1821.6733 | 2023-12-25T09:10:01 | 53.75336510 | -52.0607162 | -2059.8677 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0033_20231225_094009_MerianEM122.all | application/octet-stream | 27.4 MBytes | 0033_20231225_094009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.892 | 8642.1 | 9.3773 | 400 | 2023-12-25T09:39:59 | 53.67365415 | -52.0517726 | 173.45 | 1824.0979 | 2023-12-25T10:09:52 | 53.59626995 | -52.0422864 | 179.91 | 1643.2072 | 2023-12-25T09:39:59 | 53.67365415 | -52.0517726 | -1824.0979 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0034_20231225_101009_MerianEM122.all | application/octet-stream | 28.6 MBytes | 0034_20231225_101009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.916 | 8528.0 | 9.2456 | 442 | 2023-12-25T10:10:00 | 53.59558765 | -52.0422612 | 181.23 | 1642.7180 | 2023-12-25T10:39:55 | 53.51920795 | -52.0334246 | 179.03 | 1486.9921 | 2023-12-25T10:10:00 | 53.59558765 | -52.0422612 | -1642.7180 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0035_20231225_104011_MerianEM122.all | application/octet-stream | 30.9 MBytes | 0035_20231225_104011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.838 | 8910.8 | 9.6851 | 491 | 2023-12-25T10:40:03 | 53.51852880 | -52.0333840 | 179.32 | 1486.7457 | 2023-12-25T11:09:53 | 53.43876010 | -52.0236673 | 174.70 | 1345.2505 | 2023-12-25T10:40:03 | 53.51852880 | -52.0333840 | -1486.7457 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0036_20231225_111007_MerianEM122.all | application/octet-stream | 31.3 MBytes | 0036_20231225_111007_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 8937.6 | 9.6740 | 520 | 2023-12-25T11:10:00 | 53.43811700 | -52.0235857 | 175.18 | 1345.3513 | 2023-12-25T11:39:58 | 53.35856770 | -52.0069097 | 173.13 | 1263.0013 | 2023-12-25T11:10:00 | 53.43811700 | -52.0235857 | -1345.3513 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0037_20231225_114011_MerianEM122.all | application/octet-stream | 32.1 MBytes | 0037_20231225_114011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.868 | 8681.0 | 9.4267 | 555 | 2023-12-25T11:40:04 | 53.35800250 | -52.0067631 | 173.33 | 1267.0809 | 2023-12-25T12:09:56 | 53.28126125 | -51.9842149 | 170.43 | 1206.6750 | 2023-12-25T11:40:04 | 53.35800250 | -52.0067631 | -1267.0809 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0038_20231225_121008_MerianEM122.all | application/octet-stream | 32.6 MBytes | 0038_20231225_121008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.940 | 8685.0 | 9.4087 | 591 | 2023-12-25T12:10:02 | 53.28071550 | -51.9840607 | 172.57 | 1207.3324 | 2023-12-25T12:39:58 | 53.20393180 | -51.9619841 | 171.04 | 1129.5015 | 2023-12-25T12:10:02 | 53.28071550 | -51.9840607 | -1207.3324 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0039_20231225_124011_MerianEM122.all | application/octet-stream | 34.5 MBytes | 0039_20231225_124011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.928 | 8443.7 | 9.1512 | 644 | 2023-12-25T12:40:05 | 53.20340795 | -51.9618129 | 170.04 | 1134.8457 | 2023-12-25T13:10:00 | 53.12883740 | -51.9395773 | 171.13 | 958.8040 | 2023-12-25T12:40:05 | 53.20340795 | -51.9618129 | -1134.8457 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0040_20231225_131010_MerianEM122.all | application/octet-stream | 40.1 MBytes | 0040_20231225_131010_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.910 | 8831.5 | 9.5757 | 679 | 2023-12-25T13:10:05 | 53.12841080 | -51.9394584 | 171.49 | 961.8390 | 2023-12-25T13:40:00 | 53.05032395 | -51.9171897 | 171.88 | 1027.6514 | 2023-12-25T13:10:05 | 53.12841080 | -51.9394584 | -961.8390 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0041_20231225_134010_MerianEM122.all | application/octet-stream | 43 MBytes | 0041_20231225_134010_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.940 | 8972.3 | 9.7194 | 718 | 2023-12-25T13:40:05 | 53.04983890 | -51.9170722 | 173.12 | 1025.5437 | 2023-12-25T14:10:01 | 52.97207635 | -51.8837411 | 165.90 | 830.7838 | 2023-12-25T13:40:05 | 53.04983890 | -51.9170722 | -1025.5437 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0042_20231225_141011_MerianEM122.all | application/octet-stream | 46 MBytes | 0042_20231225_141011_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.922 | 8633.6 | 9.3578 | 840 | 2023-12-25T14:10:06 | 52.97168050 | -51.8835537 | 165.39 | 832.1212 | 2023-12-25T14:40:01 | 52.89898900 | -51.8391525 | 159.64 | 635.7714 | 2023-12-25T14:10:06 | 52.97168050 | -51.8835537 | -832.1212 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0043_20231225_144009_MerianEM122.all | application/octet-stream | 50.4 MBytes | 0043_20231225_144009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 8719.5 | 9.4355 | 1075 | 2023-12-25T14:40:05 | 52.89864610 | -51.8389234 | 158.89 | 637.3047 | 2023-12-25T15:10:03 | 52.82506800 | -51.7948661 | 151.74 | 500.6306 | 2023-12-25T14:40:05 | 52.89864610 | -51.8389234 | -637.3047 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0044_20231225_151009_MerianEM122.all | application/octet-stream | 57.9 MBytes | 0044_20231225_151009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.952 | 8451.3 | 9.1503 | 1424 | 2023-12-25T15:10:06 | 52.82486125 | -51.7946751 | 152.51 | 500.6407 | 2023-12-25T15:40:04 | 52.75363165 | -51.7519909 | 161.96 | 444.3840 | 2023-12-25T15:10:06 | 52.82486125 | -51.7946751 | -500.6407 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0045_20231225_154008_MerianEM122.all | application/octet-stream | 61.5 MBytes | 0045_20231225_154008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 8346.9 | 9.0296 | 1614 | 2023-12-25T15:40:06 | 52.75344485 | -51.7518883 | 163.73 | 445.0181 | 2023-12-25T16:10:05 | 52.68309775 | -51.7098287 | 158.41 | 411.2650 | 2023-12-25T15:40:06 | 52.75344485 | -51.7518883 | -445.0181 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0046_20231225_161009_MerianEM122.all | application/octet-stream | 63.7 MBytes | 0046_20231225_161009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.952 | 8023.0 | 8.6870 | 1772 | 2023-12-25T16:10:07 | 52.68291610 | -51.7097197 | 158.84 | 411.2845 | 2023-12-25T16:40:04 | 52.61548730 | -51.6687517 | 163.99 | 378.0721 | 2023-12-25T16:10:07 | 52.68291610 | -51.7097197 | -411.2845 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0047_20231225_164008_MerianEM122.all | application/octet-stream | 67.6 MBytes | 0047_20231225_164008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 8131.3 | 8.7997 | 1980 | 2023-12-25T16:40:06 | 52.61534045 | -51.6686580 | 166.58 | 377.0489 | 2023-12-25T17:10:04 | 52.54677380 | -51.6279548 | 162.57 | 343.2223 | 2023-12-25T16:40:06 | 52.61534045 | -51.6686580 | -377.0489 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0048_20231225_171007_MerianEM122.all | application/octet-stream | 72.6 MBytes | 0048_20231225_171007_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 8398.0 | 9.0829 | 2219 | 2023-12-25T17:10:06 | 52.54663400 | -51.6278965 | 163.53 | 343.0840 | 2023-12-25T17:40:05 | 52.47580695 | -51.5857381 | 160.66 | 330.6937 | 2023-12-25T17:10:06 | 52.54663400 | -51.6278965 | -343.0840 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0049_20231225_174008_MerianEM122.all | application/octet-stream | 71.9 MBytes | 0049_20231225_174008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 8595.3 | 9.3010 | 2173 | 2023-12-25T17:40:06 | 52.47567600 | -51.5856543 | 161.29 | 329.0887 | 2023-12-25T18:10:05 | 52.40318175 | -51.5425277 | 157.85 | 347.1211 | 2023-12-25T17:40:06 | 52.47567600 | -51.5856543 | -329.0887 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0050_20231225_181008_MerianEM122.all | application/octet-stream | 70 MBytes | 0050_20231225_181008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 8645.0 | 9.3569 | 2057 | 2023-12-25T18:10:06 | 52.40304465 | -51.5424403 | 158.67 | 347.6817 | 2023-12-25T18:40:04 | 52.33008500 | -51.4993965 | 157.02 | 361.8607 | 2023-12-25T18:10:06 | 52.40304465 | -51.5424403 | -347.6817 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0051_20231225_184008_MerianEM122.all | application/octet-stream | 68.7 MBytes | 0051_20231225_184008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 8596.9 | 9.3035 | 1984 | 2023-12-25T18:40:06 | 52.32994935 | -51.4993234 | 156.64 | 361.8810 | 2023-12-25T19:10:04 | 52.25745775 | -51.4563151 | 157.34 | 366.1768 | 2023-12-25T18:40:06 | 52.32994935 | -51.4993234 | -361.8810 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0052_20231225_191008_MerianEM122.all | application/octet-stream | 69.7 MBytes | 0052_20231225_191008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 8779.6 | 9.4973 | 2021 | 2023-12-25T19:10:06 | 52.25731680 | -51.4562326 | 157.82 | 364.7661 | 2023-12-25T19:40:05 | 52.18330035 | -51.4123136 | 153.39 | 334.5484 | 2023-12-25T19:10:06 | 52.25731680 | -51.4562326 | -364.7661 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0053_20231225_194008_MerianEM122.all | application/octet-stream | 72.2 MBytes | 0053_20231225_194008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 8482.9 | 9.1765 | 2183 | 2023-12-25T19:40:07 | 52.18315510 | -51.4122341 | 154.16 | 333.9901 | 2023-12-25T20:10:05 | 52.10884445 | -51.3867061 | 167.92 | 358.3878 | 2023-12-25T19:40:07 | 52.18315510 | -51.4122341 | -333.9901 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0054_20231225_201009_MerianEM122.all | application/octet-stream | 67.7 MBytes | 0054_20231225_201009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.946 | 8096.9 | 8.7697 | 1933 | 2023-12-25T20:10:07 | 52.10871185 | -51.3866715 | 166.78 | 357.2083 | 2023-12-25T20:40:04 | 52.03724925 | -51.3657997 | 173.13 | 384.8441 | 2023-12-25T20:10:07 | 52.10871185 | -51.3866715 | -357.2083 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0055_20231225_204008_MerianEM122.all | application/octet-stream | 65.7 MBytes | 0055_20231225_204008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 8056.6 | 8.7120 | 1830 | 2023-12-25T20:40:06 | 52.03709780 | -51.3657497 | 173.06 | 384.1079 | 2023-12-25T21:10:05 | 51.96594380 | -51.3454346 | 172.85 | 367.2399 | 2023-12-25T20:40:06 | 52.03709780 | -51.3657497 | -384.1079 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0056_20231225_211009_MerianEM122.all | application/octet-stream | 69.7 MBytes | 0056_20231225_211009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.958 | 7896.9 | 8.5495 | 2038 | 2023-12-25T21:10:07 | 51.96580195 | -51.3453991 | 174.63 | 366.9799 | 2023-12-25T21:40:04 | 51.89602440 | -51.3257659 | 165.67 | 337.0664 | 2023-12-25T21:10:07 | 51.96580195 | -51.3453991 | -366.9799 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0057_20231225_214008_MerianEM122.all | application/octet-stream | 74 MBytes | 0057_20231225_214008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 7975.8 | 8.6247 | 2276 | 2023-12-25T21:40:06 | 51.89587580 | -51.3257232 | 165.55 | 337.5598 | 2023-12-25T22:10:06 | 51.82541075 | -51.3058102 | 168.06 | 314.9453 | 2023-12-25T21:40:06 | 51.89587580 | -51.3257232 | -337.5598 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0058_20231225_221009_MerianEM122.all | application/octet-stream | 74.7 MBytes | 0058_20231225_221009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 8025.2 | 8.6869 | 2327 | 2023-12-25T22:10:07 | 51.82528645 | -51.3057700 | 166.98 | 316.0216 | 2023-12-25T22:40:05 | 51.75437795 | -51.2855628 | 169.84 | 343.7423 | 2023-12-25T22:10:07 | 51.82528645 | -51.3057700 | -316.0216 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0059_20231225_224008_MerianEM122.all | application/octet-stream | 67.5 MBytes | 0059_20231225_224008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 7955.6 | 8.6083 | 1916 | 2023-12-25T22:40:06 | 51.75423680 | -51.2855325 | 170.16 | 343.8966 | 2023-12-25T23:10:05 | 51.68369305 | -51.2681891 | 171.46 | 425.7399 | 2023-12-25T22:40:06 | 51.75423680 | -51.2855325 | -343.8966 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0060_20231225_231009_MerianEM122.all | application/octet-stream | 66.3 MBytes | 0060_20231225_231009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 7977.7 | 8.6348 | 1848 | 2023-12-25T23:10:07 | 51.68353760 | -51.2681621 | 171.22 | 423.0034 | 2023-12-25T23:40:05 | 51.61265710 | -51.2518914 | 174.01 | 373.5690 | 2023-12-25T23:10:07 | 51.68353760 | -51.2681621 | -423.0034 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0061_20231225_234008_MerianEM122.all | application/octet-stream | 69.9 MBytes | 0061_20231225_234008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 8070.1 | 8.7338 | 2055 | 2023-12-25T23:40:06 | 51.61251145 | -51.2518576 | 174.65 | 372.9349 | 2023-12-26T00:10:04 | 51.54063175 | -51.2380232 | 175.46 | 332.9836 | 2023-12-25T23:40:06 | 51.61251145 | -51.2518576 | -372.9349 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0062_20231226_001008_MerianEM122.all | application/octet-stream | 76.8 MBytes | 0062_20231226_001008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 8076.8 | 8.7345 | 2446 | 2023-12-26T00:10:06 | 51.54051810 | -51.2379843 | 175.19 | 331.2519 | 2023-12-26T00:40:05 | 51.46902340 | -51.2193003 | 170.90 | 280.1614 | 2023-12-26T00:10:06 | 51.54051810 | -51.2379843 | -331.2519 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0063_20231226_004008_MerianEM122.all | application/octet-stream | 84.6 MBytes | 0063_20231226_004008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 8011.3 | 8.6681 | 2872 | 2023-12-26T00:40:07 | 51.46889315 | -51.2192690 | 171.60 | 280.2498 | 2023-12-26T01:10:05 | 51.39809050 | -51.1992314 | 171.34 | 245.0737 | 2023-12-26T00:40:07 | 51.46889315 | -51.2192690 | -280.2498 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0064_20231226_011008_MerianEM122.all | application/octet-stream | 89.8 MBytes | 0064_20231226_011008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 8072.1 | 8.7291 | 3162 | 2023-12-26T01:10:06 | 51.39798270 | -51.1991995 | 172.49 | 244.8716 | 2023-12-26T01:40:06 | 51.32662575 | -51.1791661 | 175.00 | 235.1228 | 2023-12-26T01:10:06 | 51.39798270 | -51.1991995 | -244.8716 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0065_20231226_014008_MerianEM122.all | application/octet-stream | 88.1 MBytes | 0065_20231226_014008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 8354.8 | 9.0407 | 3067 | 2023-12-26T01:40:07 | 51.32652415 | -51.1791379 | 175.27 | 235.6825 | 2023-12-26T02:10:05 | 51.25268405 | -51.1584317 | 170.34 | 249.9656 | 2023-12-26T01:40:07 | 51.32652415 | -51.1791379 | -235.6825 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0066_20231226_021008_MerianEM122.all | application/octet-stream | 88.2 MBytes | 0066_20231226_021008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 8416.7 | 9.1015 | 3065 | 2023-12-26T02:10:07 | 51.25259475 | -51.1583994 | 171.43 | 250.4945 | 2023-12-26T02:40:06 | 51.17826190 | -51.1370408 | 169.88 | 243.8414 | 2023-12-26T02:10:07 | 51.25259475 | -51.1583994 | -250.4945 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0067_20231226_024008_MerianEM122.all | application/octet-stream | 85.2 MBytes | 0067_20231226_024008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 8405.6 | 9.0938 | 2921 | 2023-12-26T02:40:07 | 51.17816215 | -51.1370204 | 170.01 | 243.3847 | 2023-12-26T03:10:06 | 51.10443920 | -51.1120779 | 171.17 | 270.1712 | 2023-12-26T02:40:07 | 51.17816215 | -51.1370204 | -243.3847 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0068_20231226_031008_MerianEM122.all | application/octet-stream | 80.5 MBytes | 0068_20231226_031008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 8402.0 | 9.0921 | 2648 | 2023-12-26T03:10:07 | 51.10431775 | -51.1120383 | 170.38 | 269.5205 | 2023-12-26T03:40:05 | 51.03034580 | -51.0888474 | 172.14 | 284.7951 | 2023-12-26T03:10:07 | 51.10431775 | -51.1120383 | -269.5205 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0069_20231226_034008_MerianEM122.all | application/octet-stream | 78.9 MBytes | 0069_20231226_034008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 8301.8 | 8.9844 | 2555 | 2023-12-26T03:40:07 | 51.03022950 | -51.0888109 | 172.43 | 284.0673 | 2023-12-26T04:10:05 | 50.95688760 | -51.0679970 | 169.45 | 301.3809 | 2023-12-26T03:40:07 | 51.03022950 | -51.0888109 | -284.0673 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0070_20231226_041008_MerianEM122.all | application/octet-stream | 77.3 MBytes | 0070_20231226_041008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 8049.8 | 8.7056 | 2461 | 2023-12-26T04:10:06 | 50.95676785 | -51.0679721 | 169.98 | 301.1222 | 2023-12-26T04:40:06 | 50.88471530 | -51.0591445 | 174.15 | 294.4050 | 2023-12-26T04:10:06 | 50.95676785 | -51.0679721 | -301.1222 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0071_20231226_044009_MerianEM122.all | application/octet-stream | 72.2 MBytes | 0071_20231226_044009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 7842.0 | 8.4869 | 2216 | 2023-12-26T04:40:07 | 50.88460225 | -51.0591274 | 175.07 | 293.4422 | 2023-12-26T05:10:05 | 50.81441385 | -51.0504441 | 174.54 | 316.7880 | 2023-12-26T04:40:07 | 50.88460225 | -51.0591274 | -293.4422 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0072_20231226_051009_MerianEM122.all | application/octet-stream | 71.1 MBytes | 0072_20231226_051009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 7812.5 | 8.4518 | 2146 | 2023-12-26T05:10:07 | 50.81427220 | -51.0504204 | 175.50 | 317.4745 | 2023-12-26T05:40:06 | 50.74443460 | -51.0401332 | 173.20 | 349.0455 | 2023-12-26T05:10:07 | 50.81427220 | -51.0504204 | -317.4745 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0073_20231226_054009_MerianEM122.all | application/octet-stream | 69 MBytes | 0073_20231226_054009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.940 | 7647.1 | 8.2837 | 2023 | 2023-12-26T05:40:07 | 50.74428270 | -51.0401046 | 173.71 | 348.0090 | 2023-12-26T06:10:04 | 50.67612220 | -51.0272833 | 174.84 | 373.5788 | 2023-12-26T05:40:07 | 50.74428270 | -51.0401046 | -348.0090 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0074_20231226_061007_MerianEM122.all | application/octet-stream | 70.5 MBytes | 0074_20231226_061007_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 30.000 | 7667.1 | 8.2894 | 2113 | 2023-12-26T06:10:06 | 50.67596175 | -51.0272560 | 174.40 | 374.1289 | 2023-12-26T06:40:05 | 50.60759075 | -51.0149165 | 176.16 | 320.9345 | 2023-12-26T06:10:06 | 50.67596175 | -51.0272560 | -374.1289 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0075_20231226_064008_MerianEM122.all | application/octet-stream | 74.8 MBytes | 0075_20231226_064008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 7493.3 | 8.1112 | 2357 | 2023-12-26T06:40:07 | 50.60746465 | -51.0148877 | 175.78 | 321.0212 | 2023-12-26T07:10:05 | 50.54055175 | -51.0041914 | 173.88 | 294.7104 | 2023-12-26T06:40:07 | 50.60746465 | -51.0148877 | -321.0212 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0076_20231226_071008_MerianEM122.all | application/octet-stream | 75 MBytes | 0076_20231226_071008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 7425.3 | 8.0331 | 2369 | 2023-12-26T07:10:06 | 50.54044570 | -51.0041796 | 175.02 | 293.7546 | 2023-12-26T07:40:05 | 50.47409605 | -50.9942073 | 176.06 | 310.9189 | 2023-12-26T07:10:06 | 50.54044570 | -51.0041796 | -293.7546 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0077_20231226_074008_MerianEM122.all | application/octet-stream | 75.2 MBytes | 0077_20231226_074008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 7499.8 | 8.1153 | 2361 | 2023-12-26T07:40:06 | 50.47399460 | -50.9941917 | 176.49 | 310.6566 | 2023-12-26T08:10:05 | 50.40701890 | -50.9835667 | 174.84 | 311.0237 | 2023-12-26T07:40:06 | 50.47399460 | -50.9941917 | -310.6566 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0078_20231226_081008_MerianEM122.all | application/octet-stream | 74.3 MBytes | 0078_20231226_081008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 7070.2 | 7.6458 | 2323 | 2023-12-26T08:10:06 | 50.40690050 | -50.9835538 | 175.13 | 309.3833 | 2023-12-26T08:40:06 | 50.34348800 | -50.9800017 | 178.81 | 306.4284 | 2023-12-26T08:10:06 | 50.40690050 | -50.9835538 | -309.3833 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0079_20231226_084009_MerianEM122.all | application/octet-stream | 75.6 MBytes | 0079_20231226_084009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 7216.6 | 7.8101 | 2376 | 2023-12-26T08:40:07 | 50.34337710 | -50.9800031 | 179.27 | 306.7812 | 2023-12-26T09:10:05 | 50.27862465 | -50.9776881 | 179.56 | 306.8847 | 2023-12-26T08:40:07 | 50.34337710 | -50.9800031 | -306.7812 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0080_20231226_091008_MerianEM122.all | application/octet-stream | 75.3 MBytes | 0080_20231226_091008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 6994.8 | 7.5666 | 2363 | 2023-12-26T09:10:07 | 50.27851550 | -50.9776760 | 178.94 | 307.9977 | 2023-12-26T09:40:05 | 50.21574305 | -50.9756636 | 183.61 | 324.2523 | 2023-12-26T09:10:07 | 50.27851550 | -50.9776760 | -307.9977 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0081_20231226_094008_MerianEM122.all | application/octet-stream | 74.4 MBytes | 0081_20231226_094008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6868.8 | 7.4312 | 2315 | 2023-12-26T09:40:07 | 50.21564335 | -50.9756572 | 183.67 | 323.3430 | 2023-12-26T10:10:06 | 50.15413765 | -50.9809635 | 188.12 | 309.9778 | 2023-12-26T09:40:07 | 50.21564335 | -50.9756572 | -323.3430 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0082_20231226_101009_MerianEM122.all | application/octet-stream | 75.9 MBytes | 0082_20231226_101009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 6737.2 | 7.2922 | 2393 | 2023-12-26T10:10:07 | 50.15402555 | -50.9809748 | 187.45 | 310.0254 | 2023-12-26T10:40:05 | 50.09496600 | -51.0007801 | 195.15 | 310.8542 | 2023-12-26T10:10:07 | 50.15402555 | -50.9809748 | -310.0254 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0083_20231226_104008_MerianEM122.all | application/octet-stream | 75.6 MBytes | 0083_20231226_104008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6760.8 | 7.3151 | 2369 | 2023-12-26T10:40:06 | 50.09487325 | -51.0008165 | 194.56 | 309.9774 | 2023-12-26T11:10:05 | 50.03672815 | -51.0277233 | 202.46 | 312.3147 | 2023-12-26T10:40:06 | 50.09487325 | -51.0008165 | -309.9774 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0084_20231226_111008_MerianEM122.all | application/octet-stream | 75.2 MBytes | 0084_20231226_111008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6366.5 | 6.8886 | 2356 | 2023-12-26T11:10:06 | 50.03662575 | -51.0277929 | 202.67 | 312.2040 | 2023-12-26T11:40:05 | 49.98311655 | -51.0589423 | 200.92 | 310.5194 | 2023-12-26T11:10:06 | 50.03662575 | -51.0277929 | -312.2040 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0085_20231226_114008_MerianEM122.all | application/octet-stream | 75.7 MBytes | 0085_20231226_114008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 6227.2 | 6.7334 | 2374 | 2023-12-26T11:40:06 | 49.98302905 | -51.0589940 | 200.06 | 310.5545 | 2023-12-26T12:10:06 | 49.93124935 | -51.0916846 | 201.98 | 311.9112 | 2023-12-26T11:40:06 | 49.98302905 | -51.0589940 | -310.5545 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0086_20231226_121009_MerianEM122.all | application/octet-stream | 75.8 MBytes | 0086_20231226_121009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 6190.6 | 6.6992 | 2383 | 2023-12-26T12:10:07 | 49.93116345 | -51.0917423 | 201.93 | 312.9253 | 2023-12-26T12:40:06 | 49.87978325 | -51.1245899 | 205.77 | 305.1756 | 2023-12-26T12:10:07 | 49.93116345 | -51.0917423 | -312.9253 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0087_20231226_124009_MerianEM122.all | application/octet-stream | 77 MBytes | 0087_20231226_124009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6051.8 | 6.5475 | 2447 | 2023-12-26T12:40:07 | 49.87970240 | -51.1246471 | 205.39 | 305.2202 | 2023-12-26T13:10:06 | 49.82947830 | -51.1566861 | 206.49 | 300.5001 | 2023-12-26T12:40:07 | 49.87970240 | -51.1246471 | -305.2202 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0088_20231226_131009_MerianEM122.all | application/octet-stream | 78.9 MBytes | 0088_20231226_131009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 7971.8 | 8.6278 | 2544 | 2023-12-26T13:10:07 | 49.82939400 | -51.1567342 | 205.96 | 300.9778 | 2023-12-26T13:40:05 | 49.76319970 | -51.1990015 | 205.81 | 278.5536 | 2023-12-26T13:10:07 | 49.82939400 | -51.1567342 | -300.9778 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0089_20231226_134008_MerianEM122.all | application/octet-stream | 81.5 MBytes | 0089_20231226_134008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 8435.9 | 9.1239 | 2690 | 2023-12-26T13:40:06 | 49.76309215 | -51.1990804 | 205.89 | 278.9930 | 2023-12-26T14:10:06 | 49.69306370 | -51.2438273 | 210.44 | 272.0743 | 2023-12-26T13:40:06 | 49.76309215 | -51.1990804 | -278.9930 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0090_20231226_141008_MerianEM122.all | application/octet-stream | 82.7 MBytes | 0090_20231226_141008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 7318.0 | 7.9189 | 2761 | 2023-12-26T14:10:07 | 49.69299820 | -51.2438727 | 210.70 | 272.1866 | 2023-12-26T14:40:05 | 49.63223985 | -51.2825279 | 209.96 | 267.9117 | 2023-12-26T14:10:07 | 49.69299820 | -51.2438727 | -272.1866 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0091_20231226_144008_MerianEM122.all | application/octet-stream | 82.6 MBytes | 0091_20231226_144008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 8260.7 | 8.9380 | 2757 | 2023-12-26T14:40:07 | 49.63213940 | -51.2825895 | 209.63 | 268.9342 | 2023-12-26T15:10:05 | 49.56356750 | -51.3262945 | 206.54 | 283.0343 | 2023-12-26T14:40:07 | 49.63213940 | -51.2825895 | -268.9342 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0092_20231226_151008_MerianEM122.all | application/octet-stream | 76.2 MBytes | 0092_20231226_151008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 5705.6 | 6.1701 | 2431 | 2023-12-26T15:10:06 | 49.56346240 | -51.3263589 | 206.22 | 282.6331 | 2023-12-26T15:40:06 | 49.51613580 | -51.3562873 | 212.47 | 317.1204 | 2023-12-26T15:10:06 | 49.56346240 | -51.3263589 | -282.6331 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0093_20231226_154009_MerianEM122.all | application/octet-stream | 74.5 MBytes | 0093_20231226_154009_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.952 | 5938.6 | 6.4303 | 2323 | 2023-12-26T15:40:07 | 49.51602955 | -51.3563536 | 212.27 | 316.9097 | 2023-12-26T16:10:05 | 49.46673320 | -51.3875097 | 209.10 | 322.4196 | 2023-12-26T15:40:07 | 49.51602955 | -51.3563536 | -316.9097 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0094_20231226_161008_MerianEM122.all | application/octet-stream | 74.2 MBytes | 0094_20231226_161008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 6030.1 | 6.5218 | 2291 | 2023-12-26T16:10:06 | 49.46664755 | -51.3875652 | 209.90 | 321.0296 | 2023-12-26T16:40:05 | 49.41662505 | -51.4192850 | 206.85 | 322.6268 | 2023-12-26T16:10:06 | 49.46664755 | -51.3875652 | -321.0296 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0095_20231226_164008_MerianEM122.all | application/octet-stream | 54.5 MBytes | 0095_20231226_164008_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 22.794 | 2885.1 | 4.1055 | 1695 | 2023-12-26T16:40:07 | 49.41653390 | -51.4193353 | 207.09 | 322.2893 | 2023-12-26T17:02:54 | 49.39313150 | -51.4304059 | 248.54 | 324.7294 | 2023-12-26T16:40:07 | 49.41653390 | -51.4193353 | -322.2893 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0096_20231226_173244_MerianEM122.all | application/octet-stream | 74.7 MBytes | 0096_20231226_173244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.964 | 6235.1 | 6.7484 | 2320 | 2023-12-26T17:32:42 | 49.39024610 | -51.4366836 | 246.92 | 325.7751 | 2023-12-26T18:02:40 | 49.34153550 | -51.4746594 | 208.26 | 312.7776 | 2023-12-26T17:32:42 | 49.39024610 | -51.4366836 | -325.7751 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0097_20231226_180243_MerianEM122.all | application/octet-stream | 75.5 MBytes | 0097_20231226_180243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 6046.0 | 6.5425 | 2366 | 2023-12-26T18:02:41 | 49.34144970 | -51.4747091 | 208.12 | 313.4645 | 2023-12-26T18:32:40 | 49.29079255 | -51.5046728 | 207.93 | 317.2532 | 2023-12-26T18:02:41 | 49.34144970 | -51.4747091 | -313.4645 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0098_20231226_183243_MerianEM122.all | application/octet-stream | 75.6 MBytes | 0098_20231226_183243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 6078.0 | 6.5731 | 2365 | 2023-12-26T18:32:41 | 49.29070580 | -51.5047189 | 207.56 | 316.7084 | 2023-12-26T19:02:41 | 49.23970850 | -51.5345971 | 209.51 | 313.9442 | 2023-12-26T18:32:41 | 49.29070580 | -51.5047189 | -316.7084 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0099_20231226_190244_MerianEM122.all | application/octet-stream | 75.8 MBytes | 0099_20231226_190244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.952 | 6104.5 | 6.6095 | 2370 | 2023-12-26T19:02:42 | 49.23962555 | -51.5346507 | 209.93 | 316.8836 | 2023-12-26T19:32:39 | 49.18845800 | -51.5648547 | 209.06 | 317.2234 | 2023-12-26T19:02:42 | 49.23962555 | -51.5346507 | -316.8836 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0100_20231226_193242_MerianEM122.all | application/octet-stream | 76.2 MBytes | 0100_20231226_193242_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 6251.1 | 6.7606 | 2398 | 2023-12-26T19:32:41 | 49.18838115 | -51.5648997 | 209.04 | 318.2237 | 2023-12-26T20:02:40 | 49.13613885 | -51.5963481 | 209.19 | 312.8953 | 2023-12-26T19:32:41 | 49.18838115 | -51.5648997 | -318.2237 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0101_20231226_200243_MerianEM122.all | application/octet-stream | 76.4 MBytes | 0101_20231226_200243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 6385.5 | 6.9099 | 2408 | 2023-12-26T20:02:42 | 49.13604625 | -51.5964058 | 209.68 | 313.0551 | 2023-12-26T20:32:40 | 49.08302050 | -51.6298462 | 209.35 | 311.1418 | 2023-12-26T20:02:42 | 49.13604625 | -51.5964058 | -313.0551 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0102_20231226_203243_MerianEM122.all | application/octet-stream | 78.9 MBytes | 0102_20231226_203243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 6035.4 | 6.5266 | 2549 | 2023-12-26T20:32:41 | 49.08293045 | -51.6299044 | 209.09 | 311.2706 | 2023-12-26T21:02:41 | 49.03283150 | -51.6614835 | 213.24 | 299.6763 | 2023-12-26T20:32:41 | 49.08293045 | -51.6299044 | -311.2706 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0103_20231226_210244_MerianEM122.all | application/octet-stream | 76.9 MBytes | 0103_20231226_210244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6031.3 | 6.5260 | 2432 | 2023-12-26T21:02:42 | 49.03275615 | -51.6615307 | 213.09 | 299.5817 | 2023-12-26T21:32:41 | 48.98263530 | -51.6928882 | 211.13 | 314.9788 | 2023-12-26T21:02:42 | 49.03275615 | -51.6615307 | -299.5817 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0104_20231226_213244_MerianEM122.all | application/octet-stream | 75.4 MBytes | 0104_20231226_213244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.958 | 6029.7 | 6.5273 | 2355 | 2023-12-26T21:32:42 | 48.98254780 | -51.6929402 | 211.71 | 315.3345 | 2023-12-26T22:02:40 | 48.93246860 | -51.7243670 | 210.33 | 321.6486 | 2023-12-26T21:32:42 | 48.98254780 | -51.6929402 | -315.3345 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0105_20231226_220243_MerianEM122.all | application/octet-stream | 74.9 MBytes | 0105_20231226_220243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6096.4 | 6.5962 | 2330 | 2023-12-26T22:02:41 | 48.93238030 | -51.7244295 | 210.48 | 321.5918 | 2023-12-26T22:32:40 | 48.88174225 | -51.7561402 | 209.18 | 319.7314 | 2023-12-26T22:02:41 | 48.93238030 | -51.7244295 | -321.5918 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0106_20231226_223243_MerianEM122.all | application/octet-stream | 74.8 MBytes | 0106_20231226_223243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 6005.1 | 6.4947 | 2327 | 2023-12-26T22:32:41 | 48.88165900 | -51.7561862 | 209.21 | 320.1074 | 2023-12-26T23:02:40 | 48.83182160 | -51.7875661 | 209.14 | 319.2941 | 2023-12-26T22:32:41 | 48.88165900 | -51.7561862 | -320.1074 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0107_20231226_230244_MerianEM122.all | application/octet-stream | 76.4 MBytes | 0107_20231226_230244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6227.5 | 6.7373 | 2413 | 2023-12-26T23:02:42 | 48.83172725 | -51.7876221 | 208.93 | 322.3684 | 2023-12-26T23:32:41 | 48.77996545 | -51.8198279 | 212.71 | 304.5058 | 2023-12-26T23:02:42 | 48.83172725 | -51.7876221 | -322.3684 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0108_20231226_233244_MerianEM122.all | application/octet-stream | 79.1 MBytes | 0108_20231226_233244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 6318.2 | 6.8350 | 2570 | 2023-12-26T23:32:42 | 48.77987975 | -51.8198801 | 212.75 | 304.4674 | 2023-12-27T00:02:41 | 48.72744760 | -51.8528359 | 215.58 | 286.6798 | 2023-12-26T23:32:42 | 48.77987975 | -51.8198801 | -304.4674 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0109_20231227_000244_MerianEM122.all | application/octet-stream | 83.3 MBytes | 0109_20231227_000244_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6449.1 | 6.9783 | 2806 | 2023-12-27T00:02:42 | 48.72736810 | -51.8528882 | 215.40 | 287.2085 | 2023-12-27T00:32:41 | 48.67377365 | -51.8862391 | 210.42 | 249.6882 | 2023-12-27T00:02:42 | 48.72736810 | -51.8528882 | -287.2085 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0110_20231227_003243_MerianEM122.all | application/octet-stream | 89.8 MBytes | 0110_20231227_003243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 6336.1 | 6.8545 | 3164 | 2023-12-27T00:32:42 | 48.67369395 | -51.8862898 | 209.98 | 252.2951 | 2023-12-27T01:02:41 | 48.62106520 | -51.9191118 | 207.69 | 244.1897 | 2023-12-27T00:32:42 | 48.67369395 | -51.8862898 | -252.2951 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0111_20231227_010243_MerianEM122.all | application/octet-stream | 93.9 MBytes | 0111_20231227_010243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 6342.3 | 6.8577 | 3376 | 2023-12-27T01:02:42 | 48.62100280 | -51.9191472 | 207.56 | 248.5970 | 2023-12-27T01:32:41 | 48.56831565 | -51.9519488 | 204.92 | 212.9447 | 2023-12-27T01:02:42 | 48.62100280 | -51.9191472 | -248.5970 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0112_20231227_013243_MerianEM122.all | application/octet-stream | 96.7 MBytes | 0112_20231227_013243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 5963.3 | 6.4537 | 3534 | 2023-12-27T01:32:42 | 48.56826595 | -51.9519776 | 205.10 | 214.2363 | 2023-12-27T02:02:40 | 48.51875945 | -51.9829105 | 209.10 | 209.6671 | 2023-12-27T01:32:42 | 48.56826595 | -51.9519776 | -214.2363 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0113_20231227_020242_MerianEM122.all | application/octet-stream | 98.7 MBytes | 0113_20231227_020242_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 6090.7 | 6.5872 | 3649 | 2023-12-27T02:02:41 | 48.51870880 | -51.9829395 | 208.97 | 209.8199 | 2023-12-27T02:32:41 | 48.46808545 | -52.0142762 | 207.56 | 202.8833 | 2023-12-27T02:02:41 | 48.51870880 | -51.9829395 | -209.8199 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0114_20231227_023243_MerianEM122.all | application/octet-stream | 101 MBytes | 0114_20231227_023243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 6274.1 | 6.7837 | 3772 | 2023-12-27T02:32:42 | 48.46802750 | -52.0143093 | 208.04 | 203.9499 | 2023-12-27T03:02:41 | 48.41597455 | -52.0468771 | 204.73 | 197.8534 | 2023-12-27T02:32:42 | 48.46802750 | -52.0143093 | -203.9499 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0115_20231227_030243_MerianEM122.all | application/octet-stream | 103 MBytes | 0115_20231227_030243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 6403.4 | 6.9255 | 3879 | 2023-12-27T03:02:42 | 48.41591965 | -52.0469120 | 204.75 | 197.3558 | 2023-12-27T03:32:42 | 48.36267590 | -52.0797393 | 208.35 | 195.5409 | 2023-12-27T03:02:42 | 48.41591965 | -52.0469120 | -197.3558 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0116_20231227_033243_MerianEM122.all | application/octet-stream | 104.7 MBytes | 0116_20231227_033243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.970 | 6499.0 | 7.0325 | 3969 | 2023-12-27T03:32:42 | 48.36262435 | -52.0797731 | 208.66 | 195.7693 | 2023-12-27T04:02:41 | 48.30869895 | -52.1134636 | 207.00 | 183.8347 | 2023-12-27T03:32:42 | 48.36262435 | -52.0797731 | -195.7693 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0117_20231227_040242_MerianEM122.all | application/octet-stream | 106.9 MBytes | 0117_20231227_040242_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 30.000 | 6292.4 | 6.8029 | 4089 | 2023-12-27T04:02:42 | 48.30863865 | -52.1134958 | 207.17 | 184.2261 | 2023-12-27T04:32:42 | 48.25631790 | -52.1456379 | 209.79 | 181.5485 | 2023-12-27T04:02:42 | 48.30863865 | -52.1134958 | -184.2261 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0118_20231227_043243_MerianEM122.all | application/octet-stream | 108.3 MBytes | 0118_20231227_043243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 6169.8 | 6.6746 | 4165 | 2023-12-27T04:32:42 | 48.25626870 | -52.1456710 | 209.64 | 181.6134 | 2023-12-27T05:02:41 | 48.20498075 | -52.1772238 | 209.70 | 175.4551 | 2023-12-27T04:32:42 | 48.25626870 | -52.1456710 | -181.6134 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0119_20231227_050243_MerianEM122.all | application/octet-stream | 108.8 MBytes | 0119_20231227_050243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.982 | 6014.6 | 6.5061 | 4194 | 2023-12-27T05:02:42 | 48.20493860 | -52.1772506 | 209.59 | 175.6410 | 2023-12-27T05:32:41 | 48.15499175 | -52.2081838 | 205.21 | 180.0582 | 2023-12-27T05:02:42 | 48.20493860 | -52.1772506 | -175.6410 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0120_20231227_053243_MerianEM122.all | application/octet-stream | 107.1 MBytes | 0120_20231227_053243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 5985.7 | 6.4722 | 4106 | 2023-12-27T05:32:42 | 48.15493985 | -52.2082172 | 205.04 | 179.6913 | 2023-12-27T06:02:41 | 48.10518900 | -52.2387562 | 204.00 | 187.1772 | 2023-12-27T05:32:42 | 48.15493985 | -52.2082172 | -179.6913 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0121_20231227_060243_MerianEM122.all | application/octet-stream | 105.2 MBytes | 0121_20231227_060243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 6010.5 | 6.5007 | 4006 | 2023-12-27T06:02:42 | 48.10513855 | -52.2387875 | 203.74 | 186.5331 | 2023-12-27T06:32:41 | 48.05528540 | -52.2698366 | 199.96 | 192.9633 | 2023-12-27T06:02:42 | 48.10513855 | -52.2387875 | -186.5331 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0122_20231227_063243_MerianEM122.all | application/octet-stream | 103.5 MBytes | 0122_20231227_063243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6146.5 | 6.6503 | 3916 | 2023-12-27T06:32:42 | 48.05523485 | -52.2698682 | 199.85 | 192.7200 | 2023-12-27T07:02:41 | 48.00415375 | -52.3012775 | 200.06 | 196.0699 | 2023-12-27T06:32:42 | 48.05523485 | -52.2698682 | -192.7200 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0123_20231227_070243_MerianEM122.all | application/octet-stream | 102.5 MBytes | 0123_20231227_070243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 5875.1 | 6.3531 | 3858 | 2023-12-27T07:02:42 | 48.00410245 | -52.3013082 | 199.90 | 196.0933 | 2023-12-27T07:32:41 | 47.95525095 | -52.3311974 | 203.04 | 193.8128 | 2023-12-27T07:02:42 | 48.00410245 | -52.3013082 | -196.0933 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0124_20231227_073243_MerianEM122.all | application/octet-stream | 102.7 MBytes | 0124_20231227_073243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 5865.4 | 6.3461 | 3870 | 2023-12-27T07:32:42 | 47.95520080 | -52.3312333 | 203.14 | 193.6898 | 2023-12-27T08:02:41 | 47.90651265 | -52.3613494 | 203.67 | 194.5150 | 2023-12-27T07:32:42 | 47.95520080 | -52.3312333 | -193.6898 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0125_20231227_080243_MerianEM122.all | application/octet-stream | 104.4 MBytes | 0125_20231227_080243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 5916.0 | 6.3982 | 3964 | 2023-12-27T08:02:42 | 47.90645910 | -52.3613825 | 203.70 | 195.5199 | 2023-12-27T08:32:41 | 47.85727085 | -52.3914601 | 207.25 | 185.0895 | 2023-12-27T08:02:42 | 47.90645910 | -52.3613825 | -195.5199 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0126_20231227_083243_MerianEM122.all | application/octet-stream | 107.5 MBytes | 0126_20231227_083243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.994 | 5956.7 | 6.4411 | 4128 | 2023-12-27T08:32:42 | 47.85721930 | -52.3914946 | 207.34 | 184.0669 | 2023-12-27T09:02:41 | 47.80774125 | -52.4219252 | 206.49 | 177.4220 | 2023-12-27T08:32:42 | 47.85721930 | -52.3914946 | -184.0669 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0127_20231227_090243_MerianEM122.all | application/octet-stream | 110.1 MBytes | 0127_20231227_090243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.976 | 6286.5 | 6.8010 | 4267 | 2023-12-27T09:02:42 | 47.80769110 | -52.4219544 | 206.39 | 177.8474 | 2023-12-27T09:32:41 | 47.75507735 | -52.4525748 | 205.21 | 175.1801 | 2023-12-27T09:02:42 | 47.80769110 | -52.4219544 | -177.8474 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0128_20231227_093243_MerianEM122.all | application/octet-stream | 111.3 MBytes | 0128_20231227_093243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 29.988 | 5990.8 | 6.4789 | 4336 | 2023-12-27T09:32:42 | 47.75502710 | -52.4526033 | 205.14 | 175.4643 | 2023-12-27T10:02:41 | 47.70492885 | -52.4818349 | 205.30 | 170.2171 | 2023-12-27T09:32:42 | 47.75502710 | -52.4526033 | -175.4643 | GEOCODEs from start of data file recording |
MSM123_0_Underway-5 | 0129_20231227_100243_MerianEM122.all | application/octet-stream | 104.1 MBytes | 0129_20231227_100243_MerianEM122.all | multibeam raw data file .all / Kongsberg multibeam vendor format / MB-System MBIO data format ID 58 | 27.870 | 5823.0 | 6.7759 | 4070 | 2023-12-27T10:02:42 | 47.70488165 | -52.4818609 | 205.13 | 170.0762 | 2023-12-27T10:30:34 | 47.65650045 | -52.5113156 | 209.93 | 173.9836 | 2023-12-27T10:02:42 | 47.70488165 | -52.4818609 | -170.0762 | GEOCODEs from start of data file recording |