Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

McKenzie, Marion A; Miller, Lauren; Lepp, Allison; DeWitt, Regina (2024): XRF data from coastal outcrop samples of Cliffside from Whidbey Island, Washington state [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.965538, In: McKenzie, MA et al. (2024): XRF data from coastal outcrop samples of West Beach 2 from Whidbey Island, Washington state [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.965545

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
These trace element data were collected by a Niton XLF X-ray fluorescence machine (units in ppm), while magnetic susceptibility (MS) data (units in SI) were collected using a Bartington MS2 meter. Within the spreadsheet, this data is organized by site and each sample has a unique row of data. This spreadsheet also lists the difference between "field" labels (in centimeters from the beach) and "lab" labels (in centimeters from the top of the column) presented in the associated manuscript. Code to plot these data is available upon request to Dr. Marion McKenzie.
Keyword(s):
Cordilleran Ice Sheet; grain size analysis; ice sheets; magnetic susceptibility; XRF
Coverage:
Latitude: 48.301003 * Longitude: -122.693870
Date/Time Start: 2020-10-17T09:00:00 * Date/Time End: 2020-10-17T09:00:00
Minimum DEPTH, sediment/rock: 0.0 m * Maximum DEPTH, sediment/rock: 2.8 m
Event(s):
Cliffside (CS) * Latitude: 48.301003 * Longitude: -122.693870 * Date/Time: 2020-10-17T09:00:00 * Location: Whidbey Island, Washington State, United States * Method/Device: Shovel (SHOVEL) * Comment: Number of samples: 29, number of sub-sites: 2, estimated elevation (from beach/sea level): 0 - 12m , samples collected with hand shove and stored in WhirlPak bags.
Comment:
<0 = <LOD
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
NumberNoMcKenzie, Marion AReading No
NameNameMcKenzie, Marion AOld name
Lithological unit typeLithol typeMcKenzie, Marion AOriginal unit (field description)
DEPTH, sediment/rockDepth sedmMcKenzie, Marion AGeocode – Original depth (field description: cm from beach)
Lithological unit typeLithol typeMcKenzie, Marion ANew unit
Depth, top/minDepth topmMcKenzie, Marion ANew depth (from top)
Magnetic susceptibilityMAGSSIMcKenzie, Marion ALow frequency
SigmaSigmaMcKenzie, Marion A
UnitUnitMcKenzie, Marion A
10 MaterialMaterialMcKenzie, Marion AMode
11 SilverAgmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
12 Silver, standard deviationAg std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
13 ArsenicAsmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
14 Arsenic, standard deviationAs std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
15 GoldAumg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
16 Gold, standard deviationAu std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
17 BariumBamg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
18 Barium, standard deviationBa std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
19 Boron-AluminideBAlmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
20 Boron-Aluminide, standard deviationBAl std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
21 CalciumCamg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
22 Calcium, standard deviationCa std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
23 CadmiumCdmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
24 Cadmium, standard deviationCd std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
25 CobaltComg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
26 Cobalt, standard deviationCo std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
27 ChromiumCrmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
28 Chromium, standard deviationCr std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
29 CaesiumCsmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
30 Caesium, standard deviationCs std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
31 CopperCumg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
32 Copper, standard deviationCu std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
33 IronFemg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
34 Iron, standard deviationFe std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
35 MercuryHgmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
36 Mercury, standard deviationHg std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
37 PotassiumKmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
38 Potassium, standard deviationK std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
39 ManganeseMnmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
40 Manganese, standard deviationMn std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
41 MolybdenumMomg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
42 Molybdenum, standard deviationMo std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
43 NickelNimg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
44 Nickel, standard deviationNi std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
45 LeadPbmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
46 Lead, standard deviationPb std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
47 PalladiumPdmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
48 Palladium std devPd std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
49 RubidiumRbmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
50 Rubidium, standard deviationRb std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
51 SulfurSmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
52 Sulfur, standard deviationS std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
53 AntimonySbmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
54 Antimony, standard deviationSb std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
55 ScandiumScmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
56 Scandium, standard deviationSc std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
57 SeleniumSemg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
58 Selenium, standard deviationSe std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
59 TinSnmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
60 Tin, standard deviationSn std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
61 StrontiumSrmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
62 Strontium, standard deviationSr std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
63 TelluriumTemg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
64 Tellurium, standard deviationTe std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
65 ThoriumThmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
66 Thorium, standard deviationTh std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
67 TitaniumTimg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
68 Titanium, standard deviationTi std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
69 UraniumUmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
70 Uranium, standard deviationU std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
71 VanadiumVmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
72 Vanadium, standard deviationV std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
73 TungstenWmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
74 Tungsten, standard deviationW std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
75 ZincZnmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
76 Zinc, standard deviationZn std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
77 ZirconiumZrmg/kgMcKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)
78 Zirconium, standard deviationZr std dev±McKenzie, Marion AX-ray fluorescence spectrometer (Niton XLi analyzer)2-Sigma
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
2231 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


No
(Reading No)

Name
(Old name)

Lithol type
(Original unit (field descript...)

Depth sed [m]
(Original depth (field descrip...)

Lithol type
(New unit)

Depth top [m]
(New depth (from top))

MAGS [SI]
(Low frequency)

Sigma

Unit
10 
Material
(Mode)
11 
Ag [mg/kg]
12 
Ag std dev [±]
(2-Sigma)
13 
As [mg/kg]
14 
As std dev [±]
(2-Sigma)
15 
Au [mg/kg]
16 
Au std dev [±]
(2-Sigma)
17 
Ba [mg/kg]
18 
Ba std dev [±]
(2-Sigma)
19 
BAl [mg/kg]
20 
BAl std dev [±]
(2-Sigma)
21 
Ca [mg/kg]
22 
Ca std dev [±]
(2-Sigma)
23 
Cd [mg/kg]
24 
Cd std dev [±]
(2-Sigma)
25 
Co [mg/kg]
26 
Co std dev [±]
(2-Sigma)
27 
Cr [mg/kg]
28 
Cr std dev [±]
(2-Sigma)
29 
Cs [mg/kg]
30 
Cs std dev [±]
(2-Sigma)
31 
Cu [mg/kg]
32 
Cu std dev [±]
(2-Sigma)
33 
Fe [mg/kg]
34 
Fe std dev [±]
(2-Sigma)
35 
Hg [mg/kg]
36 
Hg std dev [±]
(2-Sigma)
37 
K [mg/kg]
38 
K std dev [±]
(2-Sigma)
39 
Mn [mg/kg]
40 
Mn std dev [±]
(2-Sigma)
41 
Mo [mg/kg]
42 
Mo std dev [±]
(2-Sigma)
43 
Ni [mg/kg]
44 
Ni std dev [±]
(2-Sigma)
45 
Pb [mg/kg]
46 
Pb std dev [±]
(2-Sigma)
47 
Pd [mg/kg]
48 
Pd std dev [±]
(2-Sigma)
49 
Rb [mg/kg]
50 
Rb std dev [±]
(2-Sigma)
51 
S [mg/kg]
52 
S std dev [±]
(2-Sigma)
53 
Sb [mg/kg]
54 
Sb std dev [±]
(2-Sigma)
55 
Sc [mg/kg]
56 
Sc std dev [±]
(2-Sigma)
57 
Se [mg/kg]
58 
Se std dev [±]
(2-Sigma)
59 
Sn [mg/kg]
60 
Sn std dev [±]
(2-Sigma)
61 
Sr [mg/kg]
62 
Sr std dev [±]
(2-Sigma)
63 
Te [mg/kg]
64 
Te std dev [±]
(2-Sigma)
65 
Th [mg/kg]
66 
Th std dev [±]
(2-Sigma)
67 
Ti [mg/kg]
68 
Ti std dev [±]
(2-Sigma)
69 
U [mg/kg]
70 
U std dev [±]
(2-Sigma)
71 
V [mg/kg]
72 
V std dev [±]
(2-Sigma)
73 
W [mg/kg]
74 
W std dev [±]
(2-Sigma)
75 
Zn [mg/kg]
76 
Zn std dev [±]
(2-Sigma)
77 
Zr [mg/kg]
78 
Zr std dev [±]
(2-Sigma)
283CS S1U6 90cm from U6U62.8U10.0280.812ppmSoils<01.09185.29010.7469<02.1621318.100312.7419<0014889.1143112.3185<01.7553<0.000028.4843136.23604.5469<0.00009.79123.27502.448739246.906290.7859<0.00002.90147040.427794.9995574.261019.7075<00.727675.70066.84116.93570.9835<0.00001.018739.54821.12531064.459479.7619<03.262165.010723.1293<0.00000.2972<0.00002.7781295.76941.6057<05.21097.37340.99924409.749024.94106.94692.0048103.55927.7087<0.00005.096458.62141.7291115.58071.6252
285CS S1U6 20cm from bottom U6U62.7U10.1449.732ppmSoils<01.15665.08320.7413<02.1509380.038813.2357<0022680.0566134.5390<01.8023<0.000028.4823311.43325.504133.279610.13349.00352.690736134.332090.9601<0.00003.49859239.9453106.8732718.377922.2814<00.7770120.21777.70175.07190.9649<0.00001.051426.21011.0262173.514166.3499<03.370460.681828.1043<0.00000.3001<0.00003.9230324.15471.7336<05.39263.39820.97103532.019323.23616.52872.0694115.55367.3426<0.00005.299857.60531.7739174.87371.9399
287CS S1U6 70cm from bottom U6U62.6U10.2527.052ppmSoils<01.15655.41750.7638<02.2053329.598613.4744<0021573.9863137.0617<01.8418<0.000035.3909473.77576.5660<0.000010.71069.71012.736442517.386796.8783<0.00002.78358659.8438107.8949876.399424.2024<00.7752123.39518.01285.69000.9986<0.00001.068829.85381.0728413.000975.5190<03.457042.510228.6456<0.00000.3084<0.00002.9176308.89721.7090<05.50825.22391.01644204.799325.82086.50172.0707120.36878.0935<0.00006.406173.76531.9589151.51331.8572
RP S1U4 90cmU42.5U30.3315.302ppmSoils<01.16274.88770.8351<02.5744379.551615.1121<0026044.7559131.8971<01.8243<0.000034.7319142.68414.485019.236110.555429.95103.107233376.597791.5330<0.00003.282310739.6650108.4043543.480821.2887<00.7695113.91426.30544.99000.9454<0.00001.036227.50661.10381496.576984.8990<03.560337.793019.74613.49290.41305.60672.9407382.60262.1766<05.56493.92391.14754229.364323.79419.08381.9805100.60736.692867.38477.315460.04721.8248143.88082.3408
RP S1U4 80cmU42.4U30.4338.902ppmSoils<01.16806.80320.8519<02.5514406.925715.1069<0033932.3008147.8598<01.8093<0.000039.3647143.46424.509141.855310.551127.78143.089731277.539190.4089<0.00003.34519967.0850104.9622570.521821.8528<00.7787101.51346.17854.12580.9123<0.00001.039325.46501.08811782.992988.9005<03.556137.426522.6851<0.00000.36588.97682.9460384.76812.2020<07.18723.95411.12983923.451423.17488.63971.9910102.28966.574669.13607.358553.55091.7769150.32642.3955
282CS S1U4 110cmU42.3U30.5296.592ppmSoils<01.16545.88980.7485<02.1355505.935913.9570<0027354.9102144.8369<01.8517<0.000046.4805109.74824.385435.283910.533022.54382.891835632.488389.9689<0.00004.276710717.4082112.7242568.865820.1179<00.755185.38627.17425.15380.9613<0.00001.370329.75331.0758713.999574.8468<03.4993<0.000046.7591<0.00000.2970<0.00003.2620371.12731.8356<05.60833.69470.98064120.836424.70339.34652.1723102.90487.5898<0.00005.286061.55781.8067137.54761.8030
279CS S1U4 80cmU42.2U30.6297.472ppmSoils<01.17257.33490.7622<02.0359448.080013.5733<0024520.3652137.5794<01.8375<0.000038.4849117.49154.380129.596010.294324.61922.936135249.902389.4196<0.00002.708510868.2920113.0919603.094520.4426<00.7511100.68577.36434.99010.9527<0.00001.112430.64561.0684353.169769.7192<03.428639.599728.8810<0.00000.2899<0.00003.3209360.54681.8065<05.49704.14380.95693791.628723.72986.67212.0992113.25057.4082<0.00005.377962.28821.8119137.81941.7941
270CS S1U4 30cmU42.1U30.7339.942ppmSoils<01.16906.91360.7688<02.0501444.032313.6144<0022704.0195136.6551<01.8389<0.000029.8187131.93774.613525.650910.326425.17792.947537451.738391.1718<0.00003.765811350.0752117.9771678.938621.2185<00.7567101.06327.39525.71700.9721<0.00001.071030.82941.0756<0.0000109.5578<03.436645.912128.6693<0.00000.2908<0.00003.5375368.81681.8276<05.49783.10830.97904178.443425.06577.21452.1244116.87677.8143<0.00005.348066.82611.8572140.75041.8123
263CS S1U4 0cmU42.0U30.8341.182ppmSoils<01.16755.22110.7548<02.1304444.352013.5541<0025318.5996136.7825<01.8329<0.000030.0470111.99134.256931.429810.282324.24952.886633953.441487.1079<0.00004.26029895.3047106.6065629.624920.4552<00.753991.58437.07377.27980.9881<0.00001.071327.75461.0361185.927465.2836<03.425148.954928.8330<0.00000.2915<0.00003.3686405.48371.8884<05.48893.99370.96673812.384323.40257.26792.138097.79237.1967<0.00005.230758.41621.7508159.87111.8839
276CS S1U3 60cmU31.9U40.9361.432ppmSoils<01.32896.27010.7756<02.1528444.512913.6463<0023627.4941141.5302<01.8510<0.000032.6988113.06784.595727.583810.352924.75292.957738161.367292.0951<0.00003.917811440.9326120.9088654.144720.9599<00.7728106.68617.53666.62120.9965<0.00001.076531.72801.0977262.735072.0935<03.460964.182029.6509<0.00000.2953<0.00003.2773372.16561.8430<05.51583.18600.99664145.041025.57318.79112.1734117.79847.9807<0.00005.404467.20101.8687171.36821.9432
274CS S1U3 50cmU31.8U41.0315.592ppmSoils<01.17887.35620.7852<02.1462496.630713.9719<0023700.1523139.5747<01.8646<0.000029.4138126.34434.638436.348510.557625.21142.995938440.203193.4445<0.00003.228811722.3057120.2086596.409720.6620<00.7654100.13127.51405.55850.9874<0.00001.079032.36301.1114<0.0000101.8500<03.504272.094829.3058<0.00000.3008<0.00002.9888370.10271.8594<05.61084.16051.00184667.228026.37277.78172.1739130.30118.2277<0.00007.292768.47111.9073135.06021.8188
272CS S1U3 40cmU31.7U41.1592.382ppmSoils<01.20665.49030.7631<02.1920485.976714.2014<0027409.4805141.8803<01.895237.013528.5222113.99594.326344.312810.755220.26812.887435907.281290.7382<0.00004.451110369.8447109.0422645.367421.1375<00.833686.46307.29575.98770.9967<0.00001.234423.40381.0228<0.000097.3966<03.565452.484030.0790<0.00000.3102<0.00004.5285416.07101.9586<05.72495.22590.99864488.494624.56938.71372.2273112.81977.6175<0.00005.402551.94601.7245280.31042.3593
269CS S1U3 30cmU31.6U41.2453.282ppmSoils<01.13555.16660.7255<02.1068442.742013.3527<0024474.5469132.7780<01.8091<0.000026.1609131.28764.245929.876810.132912.28212.663630825.064584.5432<0.00004.125910293.7080106.7693694.551321.3612<00.734880.54416.82244.96760.9416<0.00001.055923.87751.0015<0.000058.6936<03.367676.894827.9797<0.00000.2947<0.00003.2134383.17271.8432<05.39884.89510.95653087.206321.21339.19732.145899.02296.6343<0.00004.986253.13351.6935121.90511.7241
267CS S1U3 20cmU31.5U41.3473.202ppmSoils<01.20688.39970.8002<02.1407526.895614.2478<0024271.3574141.8298<01.8908<0.000029.879097.27684.497445.656610.739228.30483.061439458.945394.5610<0.00002.789712022.8125122.0788765.887522.4443<00.801596.45477.51805.23930.9901<0.00001.109029.86471.1035<0.000076.6220<03.566962.793929.8666<0.00000.3049<0.00004.7614387.12661.9090<05.70904.14381.01084536.531226.170510.20512.2477131.44928.1969<0.00005.514467.10381.8989199.94932.0919
265CS S1U3 10cmU31.4U41.4314.412ppmSoils<01.17765.99010.7557<02.1484507.764013.9374<0022920.4395134.9847<01.8474<0.000028.802799.16464.354439.953910.522425.39232.959937853.027391.8622<0.00003.656611972.8086118.6784560.696319.9565<00.765497.99647.32795.43700.9722<0.00001.084131.37671.0957182.303467.1894<03.4907<0.000046.9063<0.00000.3021<0.00004.7277375.19101.8499<05.58912.88010.96434409.473625.25759.32832.1849117.94677.8353<0.00005.388268.25781.8791159.04291.8964
262CS S1U2-3T 0cmU31.3U4.51.5315.792ppmSoils<01.15258.74690.7816<02.1154413.853413.3775<0022966.8828137.1658<01.8246<0.000028.0427108.73674.462919.582310.172227.99372.971136710.707089.5630<0.00003.407111385.4072118.3710966.726923.6915<00.7465114.36807.44975.75610.9569<0.00001.344629.80871.0511186.084068.0873<03.392980.792628.7114<0.00000.2885<0.00002.8878364.08651.7948<05.42353.53380.94083903.197024.46177.07922.0900107.15467.6063<0.00005.350570.93971.8765139.59281.7832
286CS S1U2 finesU21.2U51.6345.652ppmSoils<01.13845.01680.7189<02.0244418.447313.1695<0025320.4980131.9106<01.7837<0.000025.1850126.40844.124728.543510.025516.63082.738828243.179781.9500<0.00003.60179739.0293102.2510475.986318.9915<00.743872.32996.61604.79370.9286<0.00001.272524.48521.0073386.696762.8300<03.345554.293127.7242<0.00000.2820<0.00002.8454390.35051.8592<05.34712.94520.93453134.804420.97728.97622.149692.27196.4975<0.00004.976249.01951.6512147.52081.8306
284CS S1U2 gravelU21.1U51.7337.432ppmSoils<01.14857.61810.7631<02.0292447.276513.4903<0025344.3965135.3977<01.8269<0.000039.1508128.05414.277138.754510.245219.88342.809232554.107486.2667<0.00004.003210611.8115108.6568621.768720.6399<00.749078.90866.89885.23660.9472<0.00001.433427.77281.0340390.475266.9798<03.409755.067628.5375<0.00000.28574.17232.9174376.05001.8279<05.46543.91740.96363447.671622.25107.11402.106498.10456.8936<0.00005.206556.89121.7404147.17811.8246
281CS S1U1 100cmU11.0U61.8351.782ppmSoils<01.142211.88520.8301<02.1228457.734313.6047<0028116.6797145.5371<01.8245<0.000027.5014116.46794.373931.042310.320023.30872.910133818.589888.5212<0.00004.173810401.4082110.8294568.837520.1898<00.760582.19836.98305.29790.9654<0.00001.075025.13701.0330711.635473.0173<03.427759.483430.9032<0.00000.3007<0.00004.2164387.75721.8800<05.49263.75230.96943949.717024.09199.78862.1963103.31427.4354<0.00005.260052.56421.7180149.84461.8668
280CS S1U1 90cmU10.9U61.9390.702ppmSoils<01.17354.18060.6916<02.0734448.440913.6021<0028019.7461137.5755<01.8359<0.000025.392398.66053.981537.899410.331010.67312.588429666.156282.4631<0.00003.197410400.6270104.8037480.010818.6898<00.735566.16696.46114.17350.90801.12561.091122.95560.9845371.709262.5197<03.442552.921329.2263<0.00000.28284.16702.9443404.78631.8693<05.51183.60040.93853539.090621.67309.67252.150198.10556.7203<0.00004.961145.29781.5899133.02101.7603
278CS S1U1 80cmU10.8U62.0366.462ppmSoils<01.16575.78970.7362<02.1415472.630713.8166<0029196.7168144.8463<01.8542<0.000033.228093.91264.128837.777710.475618.78972.800931454.660285.5839<0.00002.96079975.3477106.5646546.466519.7527<00.759778.90906.87684.83250.9432<0.00001.078224.64501.0168507.614368.3653<03.477940.427930.8737<0.00000.2982<0.00002.9720396.44531.8833<05.57543.51930.94843837.188723.34569.03522.1699100.60747.1962<0.00005.148655.01901.7262156.28961.8796
277CS S1U1 70cmU10.7U62.1361.432ppmSoils<01.16395.91180.7387<02.1316473.744813.6593<0028272.6270142.9496<01.8439<0.000033.8440127.73894.327837.181910.337521.31132.840932675.119186.5499<0.00003.320610764.4150110.0515528.072619.5678<00.762181.07736.92625.08420.9439<0.00001.074126.29201.0329446.206467.8656<03.453135.229930.3624<0.00000.2917<0.00004.6224379.06271.8382<05.51063.01300.93843727.564522.73869.82652.1648115.43307.1652<0.00005.144958.47541.7584167.89771.9102
275CS S1U1 60cmU10.6U62.2388.252ppmSoils<01.14854.54650.7414<02.0712495.477613.6270<0030103.0391149.4019<01.8186<0.000044.2064114.10934.363242.535710.303517.34472.788732848.000087.47865.17042.769710595.4561111.4291560.184020.0190<00.787074.34356.91676.03780.9757<0.00001.055424.98691.0346192.615965.7104<03.423565.080831.8915<0.00000.29154.09922.9285397.48041.8970<05.48702.31470.97664148.795424.522610.65092.2219101.17027.5246<0.00005.174352.30511.7077206.00432.0772
273CS S1U1 50cmU10.5U62.3374.462ppmSoils<01.14935.60650.7478<02.1449477.311013.7376<0029600.5938148.5661<01.8347<0.000037.0410111.73734.353032.237510.395717.93542.827634384.773489.4982<0.00004.208610484.1221111.0387607.140720.6436<00.770885.57057.16135.05310.9649<0.00001.064526.03001.0486336.612668.5924<03.443034.080131.6259<0.00000.3030<0.00003.0776390.96011.8962<05.53253.17370.96094073.935124.30899.83192.2134105.78127.5086<0.00005.209658.07371.7801154.43241.8955
271CS S1U1 40cmU10.4U62.4406.882ppmSoils<01.14586.54800.7434<02.0541501.371913.6259<0030631.0527149.0119<01.8242<0.000033.7845110.15764.296649.813810.303918.38842.812232774.968887.4967<0.00003.25649909.5342107.0810593.605820.4661<00.762975.43876.90434.09290.9393<0.00001.067825.24021.0322419.147668.6959<03.419060.817531.9367<0.00000.29623.91562.9245397.35661.8993<05.48734.97080.97264165.665024.24839.50972.1965105.14427.4724<0.00005.313753.98091.7302153.77911.8855
268CS S1U1 30cmU10.3U62.5453.282ppmSoils<01.14824.94420.7399<02.0976462.878413.5339<0029739.4785146.1298<01.8195<0.000027.1828102.48824.212930.263310.251016.26052.749433519.910287.6109<0.00002.655610155.7520107.4743599.221420.2899<00.757970.92276.73005.98210.9672<0.00001.260525.61051.0266435.502768.1772<03.420049.991231.2049<0.00000.2937<0.00003.8107402.42911.8992<05.46482.35990.94194182.529324.06088.53372.1674114.16807.4725<0.00005.197255.28191.7304142.86131.8323
266CS S1U1 20cmU10.2U62.6375.412ppmSoils<01.17865.58910.7388<02.1078491.992013.8040<0031084.5742149.0411<01.8617<0.000037.3426113.89874.286439.673110.428520.15932.809733319.585987.2852<0.00003.894110435.2744108.9608598.575120.2997<00.755366.42826.72025.21150.9539<0.00001.081126.48731.0359301.162166.3426<03.467955.125531.8805<0.00000.2958<0.00003.8802398.98351.8870<05.56113.87300.96384052.355523.87858.99362.1742103.57107.3602<0.00005.038251.28571.6830148.32231.8486
264CS S1U1 10cmU10.1U62.7363.922ppmSoils<01.16215.90420.7328<02.0864461.119713.6505<0029783.7207147.7450<01.8403<0.000036.6510124.82704.371128.940410.338020.27802.819032869.859486.8447<0.00004.136910355.4580109.6469599.246520.2996<00.744976.17356.86564.49650.9372<0.00001.328125.43371.0267324.361167.0399<03.444156.054731.4637<0.00000.2971<0.00004.0082397.35901.8824<05.51083.63280.94503899.772223.58629.80182.1841108.71497.3451<0.00005.106255.57961.7287131.99611.7807
261CS S1U1 0cmU10.0U62.8345.142ppmSoils<01.15816.71150.7456<02.1456466.375813.5096<0028841.5488147.3581<01.8230<0.000033.2086135.31344.519734.154410.229717.01492.798435088.671989.7327<0.00002.798211000.5918113.5707607.700920.6436<00.770182.89337.09463.89240.9358<0.00001.139227.41201.0531496.570670.8982<03.401248.300131.3791<0.00000.2959<0.00004.4976386.67521.8784<05.44403.29780.97823976.445324.34498.51262.1746109.60587.5317<0.00005.324759.68381.7919164.09941.9236