Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Müller, Oliver; Fong, Allison A; Snoeijs-Leijonmalm, Pauline; Creamean, Jessie; Olsen, Lasse Mørk; Eggers, Lena; Grosse, Julia; Hoppe, Clara Jule Marie; Torstensson, Anders; Heitman, Laura; Balmonte, John Paul; Chamberlain, Emelia; Dietrich, Ulrike; Larsen, Aud; Petelenz, Elzbieta; Tsagaraki, Tatiana M; Mayers, Kyle; Langvad, Maria; Granskog, Mats A; Bratbak, Gunnar (2023): Flow cytometry dataset from CTD casts showing the abundance of microorganisms (smaller than 20 µm) during the Arctic MOSAiC expedition [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.963430

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
This dataset gives an overview of the abundance of microorganisms (smaller than 20 µm) enumerated using flow cytometry (FCM) during the Multidisciplinary drifting observatory for the study of Arctic Climate (MOSAiC) sampled from ship-based and on-ice CTD rosettes during leg 1, 2, 3, 4 and 5 (November 2019 – September 2020). Additional expedition and sampling details can be found in the ECO-overview paper (Fong et al., to be submitted to Elementa). We thank all persons involved in the expedition of the Research Vessel Polarstern during MOSAiC in 2019-2020 (AWI_PS122_00) as listed in Nixdorf et al. (2021).
Flow cytometry (FCM) is a fast, high-throughput method to enumerate the abundance of microorganism (smaller than 20 µm). FCM uses the hydrodynamic focusing of a laminar flow to separate and line up microscopic particles. When particles pass a laser beam, the generated light scattering can be used to estimate their cell size, obtain information about cell granularity and surface characteristics and determine fluorescence from inherent pigments or applied stains, such as DNA binding ones. Photosynthetic microorganisms have auto-fluorescent pigments, such as chlorophylls which in combination with the light scattering properties (cell size) or surface properties, can be used to group them into clusters of similar or identical organism types. Heterotrophic microorganisms, including archaea, bacteria and heterotrophic nanoflagellates, and virus do not have fluorescent pigments and require staining, for example using SYBR Green to stain Nucleic Acids (DNA/RNA) in order to distinguish these cells from other organic and inorganic particles in the sample.
Samples for flow cytometric analysis were taken in triplicates or quadruplicates of 1.8 mL of sample water and fixed with 36 μL 25 % glutaraldehyde (0.5 % final concentration) at 4 °C in the dark for approximately 2 hours, then flash frozen in liquid nitrogen and stored at -80 °C until analysis. The abundance of pico- and nano-sized phytoplankton and heterotrophic nanoflagellates (HNF) were determined using an Attune® NxT, Acoustic Focusing Cytometer (Invitrogen by Thermo Fisher Scientific) with a 20 mW 488 nm (blue) laser. Autotrophic pico-and nano-sized plankton were counted directly after thawing and the various groups discriminated based on their red fluorescence (BL3) vs. orange fluorescence (BL2), red fluorescence (BL3) vs. side scatter (SSC) and orange fluorescence (BL2) vs. side scatter (SSC). For HNF analysis, the samples were stained with SYBR Green I for 2 h in the dark and 1-2 mL were subsequently measured at a flow rate of 500 µl min-1 following the protocol of Zubkov et al. 2007. The abundance of virus and bacteria was determined using a FACS Calibur (Becton Dickinson) flow cytometer with a 15 mW 480 nm (blue) laser. Prior analysis of virus and bacteria, samples were first thawed, diluted x10 and x100 with 0.2 μm filtered TE buffer (Tris 10 mM, EDTA 1 mM, pH 8), stained with a green fluorescent nucleic acid dye (SYBR Green I ; Molecular Probes, Eugene, Oregon, USA) and then incubated for 10 min at 80°C in a water bath (Marie et al. 1999). Stained samples were counted at a flow rate of around 60 µL min-1 and different groups discriminated on a biparametric plot of green florescence (BL1) vs. side scatter (SSC). This allowed to distinguish virus particles of different sizes, and different bacterial groups including low nuclear acid (LNA) and high nuclear acid (HNA) bacteria. Names of size groups of photosynthetic and heterotrophic organisms are in accordance to "Standards and Best Practices For Reporting Flow Cytometry Observations: a technical manual (Version 1.1)" (Neeley et al., 2023). A short summary is listed here: RedPico = picophytoplankton (1-2 µm); RedNano = Nanophytoplankton (2-20µm), which includes subgroups RedNano_small (2-5 µm), RedNano_large (5-20 µm); OraPico = Nanophytoplankton with more orange fluorescence; OraNano = Cryptophytes; OraPicoProk = Synechococcus; HetNano = heterotrophic nanoflagellates; HetProk = bacteria (and when present archaea); HetLNA = low nucleic acid (LNA) containing bacteria; HetHNA = high nucleic acid (HNA) containing bacteria with the subgroups HetProk_medium = HNA-bacteria subgroup with less fluorescence signal, HetProk_large = HNA-bacteria subgroup with more fluorescence signal and HetProk_verylarge = HNA-bacteria subgroup with very strong fluorescence signal; Virus = virus-like particles, including size refined subgroups: LFV (low fluorescence virus or small virus); MFV (medium fluorescence virus or medium virus); HFV (high fluorescence virus or large virus) according to Larsen et al., 2008. Exemplary plots showing the gating strategies that were followed can be found in "Interoperable vocabulary for marine microbial flow cytometry" (Thyssen et al., 2022).
Keyword(s):
Arctic; flow cytometry; microbial abundance; MOSAiC_ECO; MOSAiC expedition; Water Column Data
References:
Larsen, L B; Larsen, Aud; Thyrhaug, Runar; Bratbak, Gunnar; Sandaa, Ruth-Anne (2008): Response of marine viral populations to a nutrient induced phytoplankton bloom at different pCO2 levels. Biogeosciences, 5(2), 523-533, https://doi.org/10.5194/bg-5-523-2008
Marie, Dominique; Brussaard, Corina P D; Thyrhaug, Runar; Bratbak, Gunnar; Vaulot, Daniel (1999): Enumeration of Marine Viruses in Culture and Natural. Applied and Environmental Microbiology, 65(1), 45-52, https://doi.org/10.1128/AEM.65.1.45-52.1999
Neeley, Aimee; Soto, Inia; Proctor, Christopher W (2023): Standards and Best Practices For Reporting Flow Cytometry Observations: a technical manual. Version 1.1. UNESCO/IOC, https://doi.org/10.25607/OBP-1864.2
Thyssen, Melilotus; Grégori, Gérald; Créach, Véronique; Lahbib, Soumaya; Dugenne, Mathilde; Aardema, Hedy M; Artigas, Luis Felipe; Huang, Bangqin; Barani, Aude; Beaugeard, Laureen; Bellaaj-Zouari, Amel; Beran, Alfred; Casotti, Raffaella; Del Amo, Yolanda; Denis, Michel; Dubelaar, George BJ; Endres, Sonja; Haraguchi, Lumi; Karlson, Bengt; Lambert, Christophe; Louchart, Arnaud; Marie, Dominique; Moncoiffé, Gwenaëlle; Pecqueur, David; Ribalet, François; Rijkeboer, Machteld; Silovic, Tina; Silva, Ricardo; Marro, Sophie; Sosik, Heidi M; Sourisseau, Marc; Tarran, Glen A; Van Oostende, Nicolas; Zhao, Li; Zheng, Shan (2022): Interoperable vocabulary for marine microbial flow cytometry. Frontiers in Marine Science, 9, 975877, https://doi.org/10.3389/fmars.2022.975877
Zubkov, M V; Burkill, P H; Topping, J N (2006): Flow cytometric enumeration of DNA-stained oceanic planktonic protists. Journal of Plankton Research, 29(1), 79-86, https://doi.org/10.1093/plankt/fbl059
Funding:
Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven (AWI), grant/award no. AFMOSAiC-1_00: Multidisciplinary drifting Observatory for the Study of Arctic Climate
Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven (AWI), grant/award no. AWI_PS122_00: Multidisciplinary drifting Observatory for the Study of Arctic Climate / MOSAiC
The Research Council of Norway (RCN), grant/award no. 280292: Ridges - Safe HAVens for ice-associated Flora and Fauna in a Seasonally ice-covered Arctic OCean
Coverage:
Median Latitude: 85.263782 * Median Longitude: 53.008084 * South-bound Latitude: 79.205856 * West-bound Longitude: -35.676758 * North-bound Latitude: 89.072990 * East-bound Longitude: 121.007309
Date/Time Start: 2019-11-14T03:20:00 * Date/Time End: 2020-09-25T08:59:00
Minimum DEPTH, water: m * Maximum DEPTH, water: 4458 m
Event(s):
PS122/1_7-49 * Latitude: 86.161549 * Longitude: 118.188328 * Date/Time: 2019-11-14T05:12:00 * Elevation: -4409.8 m * O2A Registry URI: registry.o2a-data.de * Campaign: PS122/1 (MOSAiC20192020) * Basis: Polarstern * Method/Device: CTD/Rosette (CTD-RO) * Comment: 10m Shelter wird entfernt; 20m; EL31 SL=4435m; Im Shelter; Shelter an Deck
PS122/1_8-46 * Latitude: 85.743112 * Longitude: 120.945947 * Date/Time: 2019-11-21T06:50:00 * Elevation: -4403.6 m * O2A Registry URI: registry.o2a-data.de * Campaign: PS122/1 (MOSAiC20192020) * Basis: Polarstern * Method/Device: CTD/Rosette (CTD-RO) * Comment: EL31, SL=4423m
PS122/1_9-50 * Latitude: 86.160395 * Longitude: 116.754612 * Date/Time: 2019-11-28T09:58:00 * Elevation: -4325.1 m * O2A Registry URI: registry.o2a-data.de * Campaign: PS122/1 (MOSAiC20192020) * Basis: Polarstern * Method/Device: CTD/Rosette (CTD-RO) * Comment: SL=4354m
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventMüller, Oliver
2Sample code/labelSample labelMüller, Oliver
3Leg NumberLegMüller, OliverMOSAiC leg
4Activity descriptionActivityMüller, OliverMOSAiC week
5Cast numberCastMüller, Oliver
6DATE/TIMEDate/TimeMüller, OliverGeocode – UTC
7Device typeDeviceMüller, Oliverdevice
8Device typeDeviceMüller, Oliverdevice code
9Depth, bathymetricBathy depthmMüller, Oliver
10LATITUDELatitudeMüller, OliverGeocode
11LONGITUDELongitudeMüller, OliverGeocode
12CollectorCollectorMüller, Oliver
13FeatureFeatureMüller, Oliver
14DEPTH, waterDepth watermMüller, OliverGeocode
15Red only fluorescing picophytoplanktonRedPico#/mlMüller, OliverAcoustic focusing cytometer, Thermo Fisher, Attune NxT [20 mW 488 nm (blue) laser]
16Red only fluorescing nanophytoplanktonRedNano#/mlMüller, OliverAcoustic focusing cytometer, Thermo Fisher, Attune NxT [20 mW 488 nm (blue) laser]
17Red only fluorescing nanophytoplankton, smallRedNano small#/mlMüller, OliverAcoustic focusing cytometer, Thermo Fisher, Attune NxT [20 mW 488 nm (blue) laser]
18Red only fluorescing nanophytoplankton, largeRedNano large#/mlMüller, OliverAcoustic focusing cytometer, Thermo Fisher, Attune NxT [20 mW 488 nm (blue) laser]
19Orange and red fluorescing picophytoplanktonOraPico#/mlMüller, OliverAcoustic focusing cytometer, Thermo Fisher, Attune NxT [20 mW 488 nm (blue) laser]
20Orange and red fluorescing nanophytoplanktonOraNano#/mlMüller, OliverAcoustic focusing cytometer, Thermo Fisher, Attune NxT [20 mW 488 nm (blue) laser]
21Orange fluorescing prokaryote picophytoplanktonOraPicoProk#/mlMüller, OliverAcoustic focusing cytometer, Thermo Fisher, Attune NxT [20 mW 488 nm (blue) laser]
22Heterotrophic nanophytoplanktonHetNano#/mlMüller, OliverAcoustic focusing cytometer, Thermo Fisher, Attune NxT [20 mW 488 nm (blue) laser]
23Heterotrophic prokaryotesHetProk#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCalibur
24Heterotrophic prokaryotes with relatively low nucleic acidHetLNA#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCalibur
25Heterotrophic prokaryotes with relatively high nucleic acidHetHNA#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCalibur
26Heterotrophic prokaryotes, mediumHetProk medium#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCalibur
27Heterotrophic prokaryotes, largeHetProk large#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCalibur
28Heterotrophic prokaryotes, very largeHetProk very large#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCalibur
29Virus-like particlesVirus-like#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCalibur
30Virus, low DNA fluorescenceVirus LDNA#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCaliburLow fluorescence virus, LFV
31Virus, medium DNA fluorescenceVirus HDNA#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCaliburMedium fluorescence virus, MFV
32Virus, high DNA fluorescenceVirus HDNA#/mlMüller, OliverFlow cytometry system, Becton Dickinson, FACSCaliburHigh fluorescence virus, HFV
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
13768 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)