Dietrich, Florian; Chen, Jia; Forstmaier, Andreas; Bi, Xiao; Reger, Björn; Luther, Andreas; Matzke, Jared; Ramezani, Mohammad; Hase, Frank; Butz, André (2023): Column-averaged dry-air mole fractions of CO2, CH4 and CO recorded in August 2018 in Garching (Munich North) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.963225, In: Dietrich, F et al. (2023): Column-averaged dry-air mole fractions of CO2, CH4 and CO recorded during an urban measurement campaign in Munich in August 2018 with five solar-tracking Fourier transform spectrometers (EM27/SUN) [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.962966
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2023-11-06 • DOI registered: 2023-11-17
Keyword(s):
Funding:
Coverage:
Latitude: 48.261000 * Longitude: 11.671000
Date/Time Start: 2018-08-01T09:33:50 * Date/Time End: 2018-08-29T17:00:21
Event(s):
Comment:
Source files including further details are given in dataset doi:10.1594/PANGAEA.962978, see file names starting with "ma".
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | DATE/TIME | Date/Time | Dietrich, Florian | Geocode – Time UTC | ||
| 2 | Solar zenith angle | SZA | deg | Dietrich, Florian | EM27/SUN - Fourier Transform Spectrometer | |
| 3 | Solar intensity | SI | AU | Dietrich, Florian | EM27/SUN - Fourier Transform Spectrometer | Solar Intensity Average |
| 4 | Solar intensity, fractional variation | SI frac var | % | Dietrich, Florian | EM27/SUN - Fourier Transform Spectrometer | |
| 5 | Dry air column-averaged mole fraction of methane | XCH4 | ppmv | Dietrich, Florian | EM27/SUN - Fourier Transform Spectrometer | |
| 6 | Dry air column-averaged mole fraction of carbon dioxide | XCO2 | ppmv | Dietrich, Florian | EM27/SUN - Fourier Transform Spectrometer | |
| 7 | Dry air column-averaged mole fraction of carbon monoxide | XCO | ppbv | Dietrich, Florian | EM27/SUN - Fourier Transform Spectrometer | |
| 8 | Diagnostic parameter Xair | Xair | Dietrich, Florian | EM27/SUN - Fourier Transform Spectrometer | Diagnostic parameter: To calculate Xair, the sum of all non-water molecules based on surface pressure is divided by the retrieved columns of dry air based on the O2 column. It should be very constant and close to 1.0. | |
| 9 | Dry air column-averaged mole fraction of oxygen, error | XO2 err | Dietrich, Florian | EM27/SUN - Fourier Transform Spectrometer | ||
| 10 | Quality flag | QF | Dietrich, Florian | Quality control flag computed by the GFIT retrieval algorithm (flag==0: good data; flag!=0: there exists an issue with the parameter it points to - e.g. flag==1 means that there is an issue with the year) |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
611748 data points
Download Data
View dataset as HTML (shows only first 2000 rows)