Thomas, Carrie L; Jansen, Boris; Czerwiński, Sambor; Gałka, Mariusz; Knorr, Klaus-Holger; van Loon, E Emiel; Egli, Markus; Wiesenberg, Guido L B (2023): Biomarker concentrations of peat core from Beerberg peatland (Central Germany) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.961133, In: Thomas, CL et al. (2023): Paleobotanical and biomarker records over 2600 years from Beerberg peatland (Central Germany) [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.961142
Always quote citation above when using data! You can download the citation in several formats below.
Funding:
Swiss National Science Foundation (SNF), grant/award no. 188684: IQ-SASS: Improved Quantitative Source Assessment of organic matter in Soils and Sediments using molecular markers and inverse modeling
Coverage:
Latitude: 50.658889 * Longitude: 10.743333
Date/Time Start: 2019-10-11T00:00:00 * Date/Time End: 2019-10-11T00:00:00
Minimum DEPTH, sediment/rock: 0.0250 m * Maximum DEPTH, sediment/rock: 3.3875 m
Event(s):
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, sediment/rock | Depth sed | m | Thomas, Carrie L | Geocode | |
2 | Depth, top/min | Depth top | m | Thomas, Carrie L | ||
3 | Depth, bottom/max | Depth bot | m | Thomas, Carrie L | ||
4 | Sample code/label | Sample label | Thomas, Carrie L | |||
5 | n-Alkane C19 | C19 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
6 | n-Alkane C20 | C20 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
7 | n-Alkane C21 | C21 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
8 | n-Alkane C22 | C22 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
9 | n-Alkane C23 | C23 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
10 | n-Alkane C24 | C24 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
11 | n-Alkane C26 | C26 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
12 | n-Alkane C26 | C26 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
13 | n-Alkane C27 | C27 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
14 | n-Alkane C28 | C28 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
15 | n-Alkane C29 | C29 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
16 | n-Alkane C30 | C30 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
17 | n-Alkane C31 | C31 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
18 | n-Alkane C32 | C32 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
19 | n-Alkane C33 | C33 | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
20 | Carbon Preference Index, n-Alkanes | CPI n-Alkanes | Thomas, Carrie L | Calculation according to Marzi et al. (1993) | ||
21 | n-Alkane, average chain length | ACL n-Alkane | Thomas, Carrie L | Calculation according to Poynter et al. (1989) | ||
22 | n-Alkane, C23/C25 ratio | C23/C25 | Thomas, Carrie L | Calculated | ||
23 | n-Alkane, C23/(C27+C31) ratio | C23/(C27+C31) | Thomas, Carrie L | Calculated | ||
24 | Index of aquatic macrophyte proxy of n-alkanes (C23+C25)/(C23+C25+C29+C31) | Paq | Thomas, Carrie L | Calculated | ||
25 | Index of waxy n-alkanes to total hydrocarbons (C27+C29+C31)/(C23+C25+C27+C29+C31) | Pwax | Thomas, Carrie L | Calculated | ||
26 | n-Alkanol C15 | C15 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
27 | n-Alkanol C16 | C16 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
28 | n-Alkanol C17 | C17 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
29 | n-Alkanol C18 | C18 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
30 | n-Alkanol C19 | C19 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
31 | n-Alkanol C20 | C20 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
32 | n-Alkanol C21 | C21 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
33 | n-Alkanol C22 | C22 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
34 | n-Alkanol C23 | C23 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
35 | n-Alkanol C24 | C24 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
36 | n-Alkanol C25 | C25 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
37 | n-Alkanol C26 | C26 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
38 | n-Alkanol C27 | C27 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
39 | n-Alkanol C28 | C28 n-A.ol | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
40 | Carbon Preference Index, n-Alkanols | CPI n-A.ol | Thomas, Carrie L | Calculation according to Marzi et al. (1993) | ||
41 | n-Alkanol average chain length | ACL n-Alkanol | Thomas, Carrie L | Calculation according to Poynter et al. (1989) | ||
42 | n-fatty acid C14 | n-C14 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
43 | n-fatty acid C15 | n-C15 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
44 | n-fatty acid C16 | n-C16 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
45 | n-fatty acid C17 | n-C17 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
46 | n-fatty acid C18 | n-C18 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
47 | n-fatty acid C19 | n-C19 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
48 | n-fatty acid C20 | n-C20 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
49 | n-fatty acid C21 | n-C21 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
50 | n-fatty acid C22 | n-C22 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
51 | n-fatty acid C23 | n-C23 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
52 | n-fatty acid C24 | n-C24 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
53 | n-fatty acid C25 | n-C25 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
54 | n-fatty acid C26 | n-C26 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
55 | n-fatty acid C27 | n-C27 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
56 | n-fatty acid C28 | n-C28 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
57 | n-fatty acid C29 | n-C29 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
58 | n-fatty acid C30 | n-C30 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
59 | n-fatty acid C31 | n-C31 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
60 | n-fatty acid C32 | n-C32 FA | µg/g | Thomas, Carrie L | Gas chromatography - Flame Ionization Detection (GC-FID), Agilent, Agilent 7890B; relative to in-house standards | |
61 | Carbon Preference Index, n-fatty acids | CPI n-FA | Thomas, Carrie L | Calculation according to Marzi et al. (1993) | ||
62 | n-fatty acids, average chain length | ACL n-fatty acids | Thomas, Carrie L | Calculation according to Poynter et al. (1989) |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
5185 data points
Download Data
View dataset as HTML (shows only first 2000 rows)