Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Kuhn, Gerhard (2003): Color measurements on sediment core PS2711-1 [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.95848

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -57.255000 * Longitude: -91.627000
Date/Time Start: 1995-05-07T07:22:00 * Date/Time End: 1995-05-07T07:22:00
Minimum DEPTH, sediment/rock: 0.03 m * Maximum DEPTH, sediment/rock: 15.34 m
Event(s):
PS2711-1 (PS35/204) * Latitude: -57.255000 * Longitude: -91.627000 * Date/Time: 1995-05-07T07:22:00 * Elevation: -4921.0 m * Penetration: 16.5 m * Recovery: 15.35 m * Location: Southeast Pacific * Campaign: ANT-XII/4 (PS35 06AQANTXII_4) * Basis: Polarstern * Method/Device: Piston corer (BGR type) (KL) * Comment: 16 core sections: 0-0.34, 0.34-1.35, 1.35-2.35, 2.35-3.35, 3.35-4.35, 4.35-5.35, 5.35-6.35, 6.35-7.35, 7.35-8.35, 8.35-9.35, 9.35-10.35, 10.35-11.35, 11.35-12.35, 12.35-13.35, 13.35-14.35, 14.35-15.35 m
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, sediment/rockDepth sedmGeocode
2Color code HLS-systemColor HLSKuhn, GerhardMunsell Color System (1994)
3Color, L*, lightnessL*Kuhn, GerhardSpectrophotometer Minolta CM-2002
4Color, a*a*Kuhn, GerhardSpectrophotometer Minolta CM-2002
5Color, b*b*Kuhn, GerhardSpectrophotometer Minolta CM-2002
6Color reflectance at 400 nmColor 400%Kuhn, GerhardSpectrophotometer Minolta CM-2002
7Color reflectance at 410 nmColor 410%Kuhn, GerhardSpectrophotometer Minolta CM-2002
8Color reflectance at 420 nmColor 420%Kuhn, GerhardSpectrophotometer Minolta CM-2002
9Color reflectance at 430 nmColor 430%Kuhn, GerhardSpectrophotometer Minolta CM-2002
10Color reflectance at 440 nmColor 440%Kuhn, GerhardSpectrophotometer Minolta CM-2002
11Color reflectance at 450 nmColor 450%Kuhn, GerhardSpectrophotometer Minolta CM-2002
12Color reflectance at 460 nmColor 460%Kuhn, GerhardSpectrophotometer Minolta CM-2002
13Color reflectance at 470 nmColor 470%Kuhn, GerhardSpectrophotometer Minolta CM-2002
14Color reflectance at 480 nmColor 480%Kuhn, GerhardSpectrophotometer Minolta CM-2002
15Color reflectance at 490 nmColor 490%Kuhn, GerhardSpectrophotometer Minolta CM-2002
16Color reflectance at 500 nmColor 500%Kuhn, GerhardSpectrophotometer Minolta CM-2002
17Color reflectance at 510 nmColor 510%Kuhn, GerhardSpectrophotometer Minolta CM-2002
18Color reflectance at 520 nmColor 520%Kuhn, GerhardSpectrophotometer Minolta CM-2002
19Color reflectance at 530 nmColor 530%Kuhn, GerhardSpectrophotometer Minolta CM-2002
20Color reflectance at 540 nmColor 540%Kuhn, GerhardSpectrophotometer Minolta CM-2002
21Color reflectance at 550 nmColor 550%Kuhn, GerhardSpectrophotometer Minolta CM-2002
22Color reflectance at 560 nmColor 560%Kuhn, GerhardSpectrophotometer Minolta CM-2002
23Color reflectance at 570 nmColor 570%Kuhn, GerhardSpectrophotometer Minolta CM-2002
24Color reflectance at 580 nmColor 580%Kuhn, GerhardSpectrophotometer Minolta CM-2002
25Color reflectance at 590 nmColor 590%Kuhn, GerhardSpectrophotometer Minolta CM-2002
26Color reflectance at 600 nmColor 600%Kuhn, GerhardSpectrophotometer Minolta CM-2002
27Color reflectance at 610 nmColor 610%Kuhn, GerhardSpectrophotometer Minolta CM-2002
28Color reflectance at 620 nmColor 620%Kuhn, GerhardSpectrophotometer Minolta CM-2002
29Color reflectance at 630 nmColor 630%Kuhn, GerhardSpectrophotometer Minolta CM-2002
30Color reflectance at 640 nmColor 640%Kuhn, GerhardSpectrophotometer Minolta CM-2002
31Color reflectance at 650 nmColor 650%Kuhn, GerhardSpectrophotometer Minolta CM-2002
32Color reflectance at 660 nmColor 660%Kuhn, GerhardSpectrophotometer Minolta CM-2002
33Color reflectance at 670 nmColor 670%Kuhn, GerhardSpectrophotometer Minolta CM-2002
34Color reflectance at 680 nmColor 680%Kuhn, GerhardSpectrophotometer Minolta CM-2002
35Color reflectance at 690 nmColor 690%Kuhn, GerhardSpectrophotometer Minolta CM-2002
36Color reflectance at 700 nmColor 700%Kuhn, GerhardSpectrophotometer Minolta CM-2002
Size:
11795 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)