Blaser, Patrick; Gutjahr, Marcus; Pöppelmeier, Frerk; Frank, Martin; Kaboth-Bahr, Stefanie; Lippold, Jörg (2023): Authigenic element concentration and neodymium isotope from IODP Sites 303-U1302, 303-U1305, and ODP Site 105--647 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.957996

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
Labrador Sea sediment cores IODP 303-U1302, 303-U1305, and ODP 105-647 were investigated for their authigenic trace metal concentrations and neodymium isotope signatures. The sediments are 0 - 35 thousand years old and the authigenic fractions were extracted with weak acid-reductive bulk sediment leaching, with leaching of the decarbonated sediment, and from picked foraminifera samples, and analysed using ICP-QMS and MC-ICP-MS in 2016 - 2019. They were interpreted in terms of exchange with sediment and sea water, and regional climate-induced changes in continental weathering and ocean circulation.
Data of three sediment sites were extracted with three different methods. Columns are site and core name, sample depth in cm top and bottom and meters composite depth, sample mass in grams, epsilon Nd signature, two standard deviations uncertainty to epsilon Nd signature, concentrations of 32 elements in µg per gram bulk sediment used, calculated carbonate concentration relative to bulk sediment mass in %, the ratio of heavy to light rare earth elements, mid rare earth element enrichment, cerium anomaly, europium anomaly, sediment age minimum, maximum, and weighted mean in thousand years inferred from sediment datings analysed with the BACON package for the R software, and the sediment classification in terms of IRD events.
Keyword(s):
authigenic sediment fraction; IODP; Labrador Sea; marine sediment; Neodymium isotopes; ocean circulation; Rare earth elements; trace metals
Related to:
Blaser, Patrick; Gutjahr, Marcus; Pöppelmeier, Frerk; Frank, Martin; Kaboth-Bahr, Stefanie; Lippold, Jörg (2020): Labrador Sea bottom water provenance and REE exchange during the past 35,000 years. Earth and Planetary Science Letters, 542, 116299, https://doi.org/10.1016/j.epsl.2020.116299
Coverage:
Median Latitude: 52.683611 * Median Longitude: -46.410910 * South-bound Latitude: 50.002776 * West-bound Longitude: -48.530217 * North-bound Latitude: 57.475150 * East-bound Longitude: -45.262000
Date/Time Start: 1985-10-23T18:15:00 * Date/Time End: 1985-10-25T06:15:00
Minimum Elevation: -3871.0 m * Maximum Elevation: -3458.8 m
Event(s):
105-647B  * Latitude: 53.331300 * Longitude: -45.262000 * Date/Time Start: 1985-10-23T18:15:00 * Date/Time End: 1985-10-25T06:15:00 * Elevation: -3871.0 m * Penetration: 103.3 m * Recovery: 93.17 m * Location: South Atlantic Ocean * Campaign: Leg105 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 11 core; 103.3 m cored; 0 m drilled; 90.2 % recovery
303-U1302B  * Latitude: 50.002776 * Longitude: -45.638167 * Elevation: -3563.4 m * Recovery: 102.82 m * Campaign: Exp303 (North Atlantic Climate 1) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 11 cores; 104.7 m cored; 98.2 % recovered; 0 m drilled; 104.7 m penetrated
303-U1302C  * Latitude: 50.166783 * Longitude: -45.638483 * Elevation: -3559.2 m * Recovery: 97.06 m * Campaign: Exp303 (North Atlantic Climate 1) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 11 cores; 104.5 m cored; 92.9 % recovered; 0 m drilled; 104.5 m penetrated
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Event labelEventBlaser, Patrick
Sample code/labelSample labelBlaser, PatrickDSDP/ODP/IODP sample designation
HalfHalfBlaser, Patrick
Depth, compositeDepth compmcdBlaser, Patrick
TreatmentTreatBlaser, Patrick
Sample massSamp mgBlaser, Patrick
ε-Neodymiumε-NdBlaser, PatrickSee Device type column
ε-Neodymium, standard deviationε-Nd std dev±Blaser, PatrickSee Device type column2SD
Device typeDeviceBlaser, PatrickMethod/Device for ε-Nd
10 MagnesiumMgµg/gBlaser, PatrickSee Device type column
11 AluminiumAlµg/gBlaser, PatrickSee Device type column
12 CalciumCaµg/gBlaser, PatrickSee Device type column
13 ScandiumScµg/gBlaser, PatrickSee Device type column
14 TitaniumTiµg/gBlaser, PatrickSee Device type column
15 ManganeseMnµg/gBlaser, PatrickSee Device type column
16 IronFeµg/gBlaser, PatrickSee Device type column
17 CobaltCoµg/gBlaser, PatrickSee Device type column
18 NickelNiµg/gBlaser, PatrickSee Device type column
19 CopperCuµg/gBlaser, PatrickSee Device type column
20 ZincZnµg/gBlaser, PatrickSee Device type column
21 RubidiumRbµg/gBlaser, PatrickSee Device type column
22 StrontiumSrµg/gBlaser, PatrickSee Device type column
23 YttriumYµg/gBlaser, PatrickSee Device type column
24 ZirconiumZrµg/gBlaser, PatrickSee Device type column
25 BariumBaµg/gBlaser, PatrickSee Device type column
26 LanthanumLaµg/gBlaser, PatrickSee Device type column
27 CeriumCeµg/gBlaser, PatrickSee Device type column
28 PraseodymiumPrµg/gBlaser, PatrickSee Device type column
29 NeodymiumNdµg/gBlaser, PatrickSee Device type column
30 SamariumSmµg/gBlaser, PatrickSee Device type column
31 EuropiumEuµg/gBlaser, PatrickSee Device type column
32 GadoliniumGdµg/gBlaser, PatrickSee Device type column
33 TerbiumTbµg/gBlaser, PatrickSee Device type column
34 DysprosiumDyµg/gBlaser, PatrickSee Device type column
35 HolmiumHoµg/gBlaser, PatrickSee Device type column
36 ErbiumErµg/gBlaser, PatrickSee Device type column
37 ThuliumTmµg/gBlaser, PatrickSee Device type column
38 YtterbiumYbµg/gBlaser, PatrickSee Device type column
39 LutetiumLuµg/gBlaser, PatrickSee Device type column
40 LeadPbµg/gBlaser, PatrickSee Device type column
41 UraniumUµg/gBlaser, PatrickSee Device type column
42 Device typeDeviceBlaser, PatrickMethod/Device for concentrations
43 CarbonatesCarb%Blaser, PatrickCalculated
44 Heavy rare-earth elements/light rare-earth elements ratioHREE/LREEBlaser, PatrickCalculated
45 Middle rare-earth elements anomalyMREE/MREE*Blaser, PatrickCalculated
46 Cerium anomalyCe/Ce*Blaser, PatrickCalculated
47 Europium anomalyEu/Eu*Blaser, PatrickCalculated
48 Age, minimum/youngAge minkaBlaser, PatrickBACON age modeling
49 Age, maximum/oldAge maxkaBlaser, PatrickBACON age modeling
50 AGEAgeka BPBlaser, PatrickBACON age modelingGeocode
51 CommentCommentBlaser, PatrickIRD event
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
4898 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Event

Sample label
(DSDP/ODP/IODP sample designation)

Half

Depth comp [mcd]

Treat

Samp m [g]

ε-Nd
(See Device type column)

ε-Nd std dev [±]
(2SD, See Device type column)

Device
(Method/Device for ε-Nd)
10 
Mg [µg/g]
(See Device type column)
11 
Al [µg/g]
(See Device type column)
12 
Ca [µg/g]
(See Device type column)
13 
Sc [µg/g]
(See Device type column)
14 
Ti [µg/g]
(See Device type column)
15 
Mn [µg/g]
(See Device type column)
16 
Fe [µg/g]
(See Device type column)
17 
Co [µg/g]
(See Device type column)
18 
Ni [µg/g]
(See Device type column)
19 
Cu [µg/g]
(See Device type column)
20 
Zn [µg/g]
(See Device type column)
21 
Rb [µg/g]
(See Device type column)
22 
Sr [µg/g]
(See Device type column)
23 
Y [µg/g]
(See Device type column)
24 
Zr [µg/g]
(See Device type column)
25 
Ba [µg/g]
(See Device type column)
26 
La [µg/g]
(See Device type column)
27 
Ce [µg/g]
(See Device type column)
28 
Pr [µg/g]
(See Device type column)
29 
Nd [µg/g]
(See Device type column)
30 
Sm [µg/g]
(See Device type column)
31 
Eu [µg/g]
(See Device type column)
32 
Gd [µg/g]
(See Device type column)
33 
Tb [µg/g]
(See Device type column)
34 
Dy [µg/g]
(See Device type column)
35 
Ho [µg/g]
(See Device type column)
36 
Er [µg/g]
(See Device type column)
37 
Tm [µg/g]
(See Device type column)
38 
Yb [µg/g]
(See Device type column)
39 
Lu [µg/g]
(See Device type column)
40 
Pb [µg/g]
(See Device type column)
41 
U [µg/g]
(See Device type column)
42 
Device
(Method/Device for concentrations)
43 
Carb [%]
(Calculated)
44 
HREE/LREE
(Calculated)
45 
MREE/MREE*
(Calculated)
46 
Ce/Ce*
(Calculated)
47 
Eu/Eu*
(Calculated)
48 
Age min [ka]
(BACON age modeling)
49 
Age max [ka]
(BACON age modeling)
50 
Age [ka BP]
(BACON age modeling)
51 
Comment
(IRD event)
303-U1302D 303-U1302D-1H-1,0-1Archive(A)0.01weak leach0.26-15.470.24Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1289.7667.12122476.0913.55990.11425.374.129.97674.443.210.3413.083.213.440.873.370.710.150.690.100.570.100.290.040.220.032.310.06Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q30.620.811.580.471.03-0.932.450.43none
303-U1302D303-U1302D-1H-1,1-2Archive(A)0.02weak leach-15.130.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1218.18118699.781062.064.1810.52566.003.1643.533.223.620.853.370.710.160.710.100.590.100.300.040.230.033.370.07Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q29.670.891.560.501.05-0.902.490.47none
303-U1302D303-U1302D-1H-1,7-8Archive(A)0.08weak leach0.27-15.260.24Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1388.4658.77125010.163491.48584.104.3310.26698.043.3019.963.213.940.863.410.710.150.700.120.600.100.300.040.220.033.140.07Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q31.250.841.650.541.01-0.682.780.75none
303-U1302D303-U1302D-1H-1,19-20Working (W)0.20weak leach0.26-15.760.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II1353.7995.07130460.99458.631.351.52730.113.760.4917.844.239.751.084.320.850.180.820.120.700.120.350.040.260.041.640.08Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q32.620.781.521.051.04-0.183.321.33none
303-U1302D303-U1302D-1H-1,19-20Working (W)0.20weak leach0.26-15.640.21Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1485.67150.78128621.5724.37445.261146.131.33714.243.790.6626.344.289.691.084.240.860.190.830.120.690.120.340.040.270.041.850.09Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q32.160.781.511.041.04-0.183.321.33none
303-U1302D303-U1302D-1H-1,39-40Working (W)0.40weak leach0.27-15.120.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II1339.0864.78125827.48381.811.083.08699.313.850.3516.244.2310.121.064.260.860.180.860.130.710.130.360.040.270.032.290.67Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q31.460.771.591.101.010.754.192.30none
303-U1302D303-U1302D-1H-1,58-59Working (W)0.59weak leach0.26-15.070.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II1349.9654.92122427.30326.800.931.78673.793.980.3218.624.2010.251.084.280.850.170.840.160.710.120.360.050.270.042.370.28Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q30.610.871.591.110.931.705.003.22none
303-U1302D303-U1302D-1H-1,78Working (W)0.78weak leach0.28-16.030.20Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1514.11122.71119596.91392.641107.141.40612.343.990.7422.924.9512.101.234.790.950.190.890.130.750.130.370.040.290.042.600.37Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q29.900.721.491.130.982.725.884.16none
303-U1302D303-U1302D-1H-1,115Working (W)1.15weak leach0.29-19.030.22Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1486.79146.25109987.5921.77359.76520.691.42505.683.420.7124.434.9212.391.154.430.840.170.760.110.630.110.320.040.250.032.710.25Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q27.500.661.361.211.024.777.616.00none
303-U1302C 303-U1302C-1H-4,118-120Working (W)1.19weak leach0.29-18.020.15Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2897.02127.7122586.170.5110.41104.16914.561.244.131.3369.281.912.0012.612.546.730.602.340.470.100.440.070.350.060.200.030.180.033.120.11Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q5.650.971.331.250.984.997.866.25none
303-U1302D303-U1302D-1H-1,135Working (W)1.35weak leach0.27-20.490.21Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus3465.40222.5672363.1612.85293.391248.021.35233.213.301.0821.504.7511.241.134.290.830.160.750.110.600.100.310.040.250.032.750.15Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q18.090.691.351.120.965.828.907.26none
303-U1302D303-U1302D-1H-2,5-6Working (W)1.56weak leach0.27-21.360.55Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2318.6082.26104910.653.22423.101.55264.502.920.5015.835.0011.431.114.190.770.160.700.100.560.100.290.040.230.033.930.30Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q26.230.671.251.121.007.0710.148.55IRD
303-U1302D303-U1302D-1H-2,24-25Working (W)1.75weak leach0.26-21.610.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1734.4958.0488943.962.57364.351.33243.482.530.4326.284.4110.451.003.750.660.140.610.090.490.090.260.030.210.033.480.13Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q22.240.671.231.151.008.2311.229.74IRD
303-U1302D303-U1302D-1H-2,44-45Working (W)1.95weak leach0.29-19.100.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2207.74203.4076535.0411.91320.401.359.453.29273.212.930.8313.694.3310.411.013.860.720.160.690.110.570.100.290.040.240.032.740.39Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q19.130.741.371.151.059.6012.3610.99none
303-U1302D303-U1302D-1H-2,63-64Working (W)2.14weak leach0.27-22.530.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2941.9377.7091495.39445.872.712.02170.432.120.5011.983.627.950.803.020.550.110.480.070.390.070.210.030.170.021.950.18Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q22.870.631.231.081.0311.0413.3912.17IRD
303-U1302D303-U1302D-1H-2,83-84Working (W)2.34weak leach0.26-17.720.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2404.8481.3465817.832.89200.310.47195.822.730.6524.233.759.290.923.560.700.150.670.100.560.100.290.040.240.033.170.11Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q16.450.851.371.151.0512.4114.9713.64none
303-U1302D303-U1302D-1H-2,102-103Working (W)2.53weak leach0.29-19.030.43Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II3239.60134.6045707.077.04160.581.080.9592.843.031.4219.983.918.900.963.690.750.160.730.110.610.110.330.040.280.044.390.08Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q11.430.941.371.061.0113.7816.3915.13IRD
303-U1302D303-U1302D-1H-2,121-122Working (W)2.72weak leach0.27-24.120.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II3863.02120.6194032.49346.63205.250.492.68138.551.780.6212.353.226.530.702.550.450.080.380.060.320.050.170.020.140.021.830.22Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q23.510.641.151.000.9615.2917.6516.58IRD
303-U1302D303-U1302D-1H-2,134-135Working (W)2.85weak leach0.27-23.860.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2276.5046.26113842.19387.53249.900.55193.612.700.4315.624.328.170.903.380.580.110.510.080.420.080.240.030.210.030.34Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q28.460.711.110.950.9315.9818.6517.37IRD
303-U1302D303-U1302D-1H-2,148-149Working (W)2.99weak leach0.28-17.390.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II3213.47225.2816854.800.519.73153.52386.871.093.497.3146.083.561.5419.823.999.631.044.200.870.180.840.120.710.130.370.040.310.044.890.04Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q4.210.921.491.090.9816.7819.6418.23none
303-U1302D303-U1302D-1H-3,11-12Working (W)3.12weak leach0.28-17.670.25Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2328.35104.5519776.814.93143.331.4015.8247.032.751.4915.463.217.760.813.230.680.150.660.100.550.100.290.040.240.036.250.03Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q4.940.961.441.111.0417.5220.4819.00none
303-U1302D303-U1302D-1H-3,24-25Working (W)3.25weak leach0.28-21.120.32Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2370.36136.4488378.488.76396.30156.831.512.71289.762.860.6614.594.5210.231.033.820.690.120.630.120.510.080.280.040.210.032.720.11Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q22.090.711.321.100.8718.2521.3019.80IRD
303-U1302D303-U1302D-1H-3,37-38Working (W)3.38weak leach0.30-16.890.13Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1783.9879.7515723.543.09134.341.2342.472.651.2322.783.087.540.793.160.650.150.640.090.540.100.280.040.240.035.470.08Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q3.930.951.461.111.1019.0622.0620.58none
303-U1302E 303-U1302E-1H-3,40-41Working (W)3.52weak leach0.29-17.800.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II3219.67141.6918813.283.50186.48173.861.324.6345.873.101.2814.303.538.470.903.570.750.140.710.110.590.110.310.040.260.044.990.04Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q4.700.901.471.100.9219.9122.9021.44none
303-U1302E303-U1302E-1H-3,53-54Working (W)3.65weak leach0.26-17.380.29Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2295.30179.6513638.299.00147.00379.671.594.6536.222.831.2012.353.187.440.813.220.690.140.650.100.550.100.280.030.230.034.250.05Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q3.410.911.491.070.9920.7223.6722.24none
303-U1302E303-U1302E-1H-3,66-67Working (W)3.78weak leach0.27-21.050.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus3271.7042.4660685.28280.981.1287.512.410.7922.503.517.690.823.120.590.120.560.080.470.080.250.030.210.034.950.19Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q15.170.811.301.050.9921.6224.3723.02IRD
303-U1302E303-U1302E-1H-3,79-80Working (W)3.91weak leach0.29-22.140.29Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2944.08130.5851737.91185.01654.221.14117.052.730.7211.393.808.630.893.380.650.100.580.110.480.080.260.040.200.033.080.20Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q12.930.821.371.080.7522.5725.0723.81IRD
303-U1302E303-U1302E-1H-3,93-94Working (W)4.05weak leach0.19-19.390.27Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II3565.51275.9248227.516.77179.601.70105.373.321.2416.954.6711.291.114.290.880.180.830.120.670.120.350.050.290.045.160.22Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q12.060.831.391.141.0023.5525.9424.70IRD
303-U1302E303-U1302E-1H-3,106-107Working (W)4.18weak leach0.272575.36100.9547247.862.61178.611.68105.542.920.6723.404.029.740.973.750.750.160.740.100.590.110.310.040.260.044.640.25Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q11.810.871.371.141.0324.3326.9425.59IRD
303-U1302E303-U1302E-1H-3,106-107Working (W)4.18weak leach0.30-14.770.28Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus3665.0033.7417.490.070.110.150.020.100.020.020.010.010.01Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.920.691.360.7624.3326.9425.59IRD
303-U1302E303-U1302E-1H-3,106-107Working (W)4.18weak leach0.29-16.060.20Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus2431.28136.9533721.700.483.02130.28567.321.793.0799.973.271.0112.203.819.070.973.760.810.190.780.140.680.130.340.050.290.064.740.17Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q8.431.101.461.091.1124.3326.9425.59IRD
303-U1302E303-U1302E-1H-3,106-107Working (W)4.31weak leach0.25-17.430.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2317.13130.3540206.804.44169.671.790.99108.463.250.7822.584.0410.141.013.970.820.180.810.120.660.120.340.040.270.044.420.24Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q10.050.871.471.161.0225.1127.9226.48none
303-U1302E303-U1302E-1H-3,132-133Working (W)4.44weak leach0.27-18.700.35Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2997.22172.3844858.066.59210.61425.242.56120.913.110.9712.023.979.380.983.840.780.150.720.110.600.110.310.040.250.033.550.23Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q11.210.791.451.100.9625.9228.8427.37none
303-U1302E303-U1302E-1H-3,146-147Working (W)4.58weak leach0.30-20.150.27Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Kiel, Plasma II2739.2293.1474146.783.73190.171.694.190.81118.112.690.7311.903.858.980.903.440.680.140.640.090.540.100.280.040.240.034.200.31Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q18.540.841.331.111.0026.8629.7528.34IRD
303-U1302E303-U1302E-1H-4,9-10Working (W)4.71weak leach0.29-18.720.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2344.8288.4248731.402.52161.281.97116.332.890.64205.683.959.600.953.740.760.160.730.110.600.110.310.040.260.044.410.27Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q12.180.871.401.141.0227.7530.5529.22none
303-U1302E303-U1302E-1H-4,28-30Working (W)4.90weak leach0.28-19.550.24Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus3020.93121.4147182.1611.45151.151840.611.6015.57123.842.980.958.683.888.930.953.710.730.140.710.110.580.100.300.040.250.033.100.23Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q11.800.811.441.070.8929.2731.6930.56IRD
303-U1302E303-U1302E-1H-4,66-68Working (W)5.28weak leach0.29-18.960.25Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus3660.24188.0747201.0819.89216.681245.892.231.78116.563.401.3416.524.3710.091.074.100.810.170.790.120.660.120.350.040.290.043.950.16Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q11.800.871.411.081.0031.4734.3132.91none
303-U1302E303-U1302E-1H-4,85-87Working (W)5.47weak leach0.29-18.620.20Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus3236.38166.5138233.565.59146.31918.751.3410.14101.323.121.3815.203.878.790.953.700.750.160.720.110.610.110.320.040.260.043.790.14Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q9.560.881.441.061.0132.4735.5134.04none
303-U1302D303-U1302D-1H-1,1-30.01weak leach decarbonated-15.810.20Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II5011.582798.5928159.421.20235.347187.283437.8226.42101.261.50110.0812.554.8636.1414.9237.663.7414.922.540.562.600.412.180.391.100.140.850.1336.40Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.671.481.161.01-0.912.470.45none
303-U1302D303-U1302D-1H-1,86-880.86weak leach decarbonated-16.490.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma IIMass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q3.146.244.55none
303-U1302B 303-U1302B-1H-2,16-182.48weak leach decarbonated-18.250.10Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II8088.79645.9225830.031.3336.51240.521187.9685.381.8633.4412.459.4344.5017.1541.784.5417.013.080.682.860.432.210.401.070.150.930.1421.76Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.601.391.091.0713.4316.0914.78none
303-U1302B303-U1302B-1H-2,26-282.58weak leach decarbonated-17.120.37Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II52661.61619.19132326.332.4529.15961.482244.715.02179.483.8997.2516.0413.84130.2719.8645.295.4421.363.660.843.640.522.760.501.380.191.080.1724.02Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.611.431.001.0714.2216.7615.56IRD
303-U1302B303-U1302B-1H-2,61-632.93weak leach decarbonated-15.760.16Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II31492.031337.7786882.703.7970.59928.533897.0810.76206.225.1382.4426.9923.32109.3739.1698.5710.5640.817.061.556.551.015.010.982.560.382.080.3563.33Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.631.351.111.0616.4819.2517.89none
303-U1302B303-U1302B-1H-2,111-1133.43weak leach decarbonated-17.730.16Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II4988.34810.3816693.771.5246.54258.761993.025.6473.541.9524.5711.659.3932.7517.8245.144.4417.032.960.642.570.392.050.411.080.150.830.1224.64Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.561.311.171.0719.4022.3920.92none
303-U1302B303-U1302B-1H-3,6-83.88weak leach decarbonated-17.200.17Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II7107.171255.6223621.492.7379.35293.363086.314.19165.002.6533.7824.6422.2246.7035.6995.879.5336.746.061.376.080.884.530.862.350.331.900.2840.32Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.611.371.191.0522.3924.9523.66IRD
303-U1302B303-U1302B-1H-3,21-234.03weak leach decarbonated-18.520.19Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II31881.341147.8482606.333.2355.261010.233811.1614.82186.625.2673.7522.1420.0796.9932.1978.108.7134.085.791.185.410.784.050.762.060.261.610.2442.08Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.551.371.070.9823.4925.7924.60IRD
303-U1302B303-U1302B-1H-3,56-584.38weak leach decarbonated-15.460.14Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II19166.971511.7059231.852.8971.09488.672674.534.89300.164.1782.6632.1918.28110.8745.57118.8012.2248.018.001.717.681.135.961.052.800.352.270.3249.91Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.531.431.151.0125.5728.4226.99none
303-U1302B303-U1302B-1H-3,101-1034.83weak leach decarbonated-16.950.20Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II28663.591300.9376670.523.1054.89642.653165.0414.89217.344.8275.8328.1317.87126.2343.64110.6911.5544.867.681.627.121.005.340.942.580.321.940.2761.980.21Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.491.411.131.0228.7331.2830.08IRD
303-U1302B303-U1302B-1H-3,131-1335.13weak leach decarbonated-15.000.19Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Nu Instruments, Nu GEOTOP, Plasma II19876.652693.4764787.804.20119.00514.594447.817.89325.464.9790.1243.4326.0972.2858.43150.8416.0662.6211.032.3610.061.507.971.433.820.503.160.4269.26Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.000.561.431.131.0430.6833.3032.00none
303-U1305B 303-U1305B-1H-1,0-1Working (W)0.01weak leach0.29-8.540.34Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus1244.8983.88115223.080.446.14468.153.49562.383.158.532.582.450.712.960.670.170.710.100.590.110.310.040.240.032.600.05Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q28.811.101.670.421.130.210.400.32none
303-U1305B303-U1305B-1H-1,4-5Archive(A)0.05weak leach0.27-9.240.18Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1445.8990.03132974.346.37736.624.55819.104.2555.423.122.600.893.740.850.210.890.130.780.150.390.050.300.040.07Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q33.241.121.710.361.150.300.450.39none
303-U1305B303-U1305B-1H-1,4-5Archive(A)0.05weak leach0.27-9.000.20Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1180.73120.92126855.480.479.34644.383.85594.333.4431.462.872.600.773.290.740.180.770.110.630.110.320.040.250.032.540.05Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q31.711.031.690.401.140.300.450.39none
303-U1305B303-U1305B-1H-1,6-7Archive(A)0.07weak leach0.28-8.950.20Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1219.411481.04121065.990.488.281014.634.65594.303.5130.992.882.690.793.380.780.190.790.110.650.120.340.040.260.042.510.06Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q30.271.081.640.411.120.360.490.44none
303-U1305B303-U1305B-1H-1,9-10Working (W)0.10weak leach0.24-8.570.36Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Erlangen, Neptune Plus1458.53202.13136381.722.6020.721530.19293.004.791.10714.304.1242.943.163.060.883.640.850.240.900.150.750.150.380.050.300.020.04Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q34.100.951.950.421.290.430.550.50none
303-U1305B303-U1305B-1H-1,19-20Working (W)0.20weak leach0.26-8.180.36Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Erlangen, Neptune Plus1216.87184.66101641.420.942.56266.440.6361.72545.323.4928.852.875.160.783.200.720.190.760.120.650.130.320.040.260.040.07Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q25.411.101.710.791.180.600.830.71none
303-U1305B303-U1305B-1H-1,29-30Working (W)0.30weak leach0.26-8.250.18Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus1422.4982.05120047.232.77337.851.451.30625.694.212.7326.153.897.501.004.150.930.230.970.140.830.150.410.050.320.042.170.13Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q30.011.021.660.881.140.731.240.99none
303-U1305B303-U1305B-1H-1,49-50Working (W)0.50weak leach0.29-8.450.18Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus975.9663.18105911.203.34335.391.000.95527.413.410.8223.413.166.000.813.380.750.190.800.110.660.120.340.040.260.031.740.09Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q26.481.021.660.871.141.291.831.57none
303-U1305B303-U1305B-1H-1,72-730.73forams-8.870.68Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus97734.5745.70347.330.681.510.520.850.130.570.130.030.140.020.130.020.060.010.050.02Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q24.431.301.660.751.061.912.382.14none
303-U1305B303-U1305B-1H-1,72-73Archive(A)0.73weak leach0.25-8.560.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1242.58116747.240.502.53553.191.32592.144.2537.993.957.611.044.280.950.240.970.140.810.150.430.050.330.042.100.22Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q29.191.021.610.871.151.912.382.14none
303-U1305B303-U1305B-1H-1,98.5-99.5Working (W)0.99weak leach0.29-8.740.26Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus1180.6065.59113536.310.497.17505.751.27546.694.110.4612.293.927.641.034.350.950.230.960.140.810.150.420.060.320.042.030.22Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q28.381.011.610.871.142.552.882.74none
303-U1305B303-U1305B-1H-1,129-130Working (W)1.30weak leach0.29-8.840.26Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus1240.3293.80101475.200.5411.75434.251.72493.464.210.509.874.087.791.064.460.980.240.970.140.830.150.420.060.330.042.160.11Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q25.370.991.590.861.183.113.463.25none
303-U1305B303-U1305B-1H-1,143-144Archive(A)1.44weak leach0.30-8.730.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1554.2671.72112933.9115.03565.722.682.29599.505.2540.244.698.941.255.161.160.281.160.171.020.190.490.070.400.050.26Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q28.231.001.660.851.133.423.613.52none
303-U1305B303-U1305B-1H-2,67-68Working (W)2.18weak leach0.27-9.160.28Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus640.4641695.407.45273.231.15214.672.2219.922.174.300.562.290.500.120.510.080.440.080.220.030.180.020.06Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q10.421.021.580.901.114.174.614.39none
303-U1305B303-U1305B-1H-2,67-68Working (W)2.18weak leach0.29-9.140.20Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1368.17148.7485984.730.5217.36584.502.61436.384.510.6625.564.478.931.154.771.050.251.060.150.890.160.460.060.370.052.830.11Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q21.501.021.580.911.134.174.614.39none
303-U1305B303-U1305B-1H-2,137-138Working (W)2.88weak leach0.27-9.440.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1332.9562.0693649.830.497.15550.921.86477.994.340.4535.344.379.071.124.600.980.241.020.150.860.160.440.060.350.052.670.18Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q23.411.001.570.941.145.805.935.86none
303-U1305B303-U1305B-1H-3,54-55Working (W)3.55weak leach0.26-10.060.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1364.7284.5784590.890.4911.83551.492.89422.264.310.5138.494.469.771.134.570.990.241.000.150.860.150.450.060.360.052.860.15Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q21.151.011.541.001.156.796.946.87none
303-U1305B303-U1305B-1H-3,88-90Working (W)3.89weak leach0.26-10.270.25Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus1215.93201.3762381.260.4618.50340.091.991.23309.023.980.9430.304.048.371.014.110.880.220.930.130.780.140.400.050.320.042.620.08Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q15.601.001.590.961.157.257.367.31IRD
303-U1305B303-U1305B-1H-3,132-133Working (W)4.33weak leach0.25-11.150.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1386.89111.6362082.8912.72367.932.14303.163.900.6331.694.279.211.044.220.880.210.900.130.770.140.410.050.330.052.810.18Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q15.521.001.481.011.137.797.947.88IRD
303-U1305B303-U1305B-1H-4,8.5-9.5Working (W)4.59weak leach0.26-10.930.23Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus1497.67205.4158673.920.4624.03371.902.22287.503.691.2213.053.998.460.963.870.840.210.850.120.730.130.370.050.310.042.570.14Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q14.671.011.521.001.157.898.027.96IRD
303-U1305B303-U1305B-1H-4,53-54Working (W)5.04weak leach0.28-12.590.16Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2533.64370.6045556.580.5742.55329.29630.871.938.663.68250.137.061.4738.636.9715.411.797.281.540.391.560.231.370.270.710.100.610.113.260.11Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q11.391.171.431.011.198.068.708.34IRD
303-U1305B303-U1305B-1H-4,53-54Working (W)5.04weak leach0.28-12.600.16Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1240.28196.9321661.060.3517.88155.17221.750.9949.420.84112.673.501.155.703.727.870.944.020.820.210.890.120.750.140.400.050.320.043.360.05Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q5.421.001.570.971.138.068.708.34IRD
303-U1305B303-U1305B-1H-4,58-60Working (W)5.09weak leach0.26-11.740.23Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus1856.35316.6219671.980.4830.54181.46179.590.86103.084.382.356.574.7610.601.235.021.070.281.090.160.930.170.480.060.400.063.050.03Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q4.921.031.511.011.208.118.748.39IRD
303-U1305B303-U1305B-1H-4,69-70Working (W)5.20weak leach0.27-9.580.37Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Erlangen, Neptune Plus990.44257.5110798.101.7917.30111.33292.100.441.8052.592.911.089.242.665.490.722.900.660.190.680.120.570.120.300.040.240.020.02Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q2.700.991.800.911.358.158.878.49IRD
303-U1305B303-U1305B-1H-4,123-124Working (W)5.74weak leach0.28-11.040.18Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus822.9856.3935368.757.35178.681.67159.622.2217.912.495.450.602.490.520.130.520.080.440.080.230.030.180.030.09Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q8.840.941.531.031.158.619.949.22none
303-U1305B303-U1305B-1H-4,123-124Working (W)5.74weak leach0.30-11.000.13Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus895.2047481.3810.74257.23245.572.523.097.750.51220.782.870.2824.452.946.550.773.340.690.150.670.090.590.100.270.030.240.031.990.14Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q11.870.831.591.001.038.619.949.22none
303-U1305B303-U1305B-1H-5,47-48Working (W)6.48weak leach0.29-10.370.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1181.6284.0641749.3513.35295.932.35185.863.230.3923.523.347.500.833.450.740.180.750.110.640.120.340.040.270.042.120.14Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q10.441.031.531.041.169.4511.0910.27none
303-U1305B303-U1305B-1H-5,117-118Working (W)7.18weak leach0.26-10.850.16Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus860.6720828.2013.40171.23341.572.073.1410.120.4994.472.830.4118.342.656.290.773.470.690.140.720.070.640.090.260.030.230.021.760.08Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q5.210.731.741.010.9610.4711.9611.29IRD
303-U1305B303-U1305B-1H-5,144-145Working (W)7.45weak leach0.27-11.890.37Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Erlangen, Neptune Plus1470.80340.1019414.4440.15161.61313.091.4591.373.331.0110.933.527.680.893.640.770.190.750.110.650.120.330.040.270.040.04Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q4.850.971.511.001.1810.9612.2511.66IRD
303-U1305B303-U1305B-1H-6,38-39Working (W)7.89weak leach0.25-13.360.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus93.014801.180.157.0847.98146.010.370.443.810.870.2718.961.890.616.512.134.510.422.000.370.090.360.050.330.050.170.020.120.020.640.03Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q1.200.801.431.091.1511.8912.7112.30IRD
303-U1305C 303-U1305C-2H-2,48-49Working (W)8.62weak leach0.29-11.060.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1406.38131.8928676.9219.49339.153.06121.133.560.6820.983.899.000.994.010.850.220.860.130.730.130.370.050.300.042.320.10Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q7.170.971.541.061.2112.6914.6113.58IRD
303-U1305C303-U1305C-2H-2,48-49Working (W)8.62weak leach0.26-10.880.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1464.39124.1326206.1022.81305.922.68109.653.340.7821.243.628.480.923.680.780.200.800.120.660.120.340.050.280.042.260.09Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q6.550.971.521.071.1912.6914.6113.58IRD
303-U1305B303-U1305B-2H-1,39-40Working (W)9.32weak leach0.25-9.690.18Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1751.58234.2416024.8625.66224.27334.252.59138.002.1369.303.450.5923.733.498.020.913.720.800.210.820.130.700.130.360.050.280.040.08Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q4.011.021.591.041.2113.7615.9514.85none
303-U1305B303-U1305B-2H-1,70-72Working (W)9.63weak leach0.26-9.720.26Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus2497.13254.2927458.9134.25410.79237.813.8282.323.541.436.043.799.650.983.940.850.210.860.120.720.130.370.050.310.042.770.07Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q6.861.021.511.151.1714.3416.4515.43none
303-U1305B303-U1305B-2H-1,111-112Working (W)10.04weak leach0.28-19.350.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus4143.66131.5329965.185.46512.720.4750.713.350.9422.354.1710.341.054.110.840.180.800.120.670.120.360.050.300.044.340.07Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q7.490.941.371.141.0515.1716.9816.17IRD
303-U1305B303-U1305B-2H-1,131-132Working (W)10.24weak leach0.28-16.270.13Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2316.0684.9236183.934.87423.631.9163.442.820.7123.803.558.470.903.520.710.160.680.100.580.100.310.040.260.043.400.26Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q9.050.921.381.091.1015.6517.2516.53IRD
303-U1305B303-U1305B-2H-2,3-4Working (W)10.46weak leach0.30-14.110.28Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1065.26110.058325.792.8581.240.385.5626.912.340.7912.262.585.790.662.660.560.140.560.080.470.080.250.030.200.032.510.05Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q2.081.001.491.031.1316.2917.5016.94IRD
303-U1305B303-U1305B-2H-2,22-23Working (W)10.65weak leach0.28-11.670.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1234.52170.988451.928.93115.300.3332.913.291.0411.963.477.830.903.720.780.200.780.110.670.120.350.050.290.040.02Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q2.111.041.481.021.2017.0717.9417.51none
303-U1305B303-U1305B-2H-2,30-32Working (W)10.73weak leach0.28-15.260.26Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus1938.96266.2717332.6710.04163.250.3677.333.451.687.463.999.761.054.140.860.210.860.120.690.130.370.050.300.043.65Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q4.330.961.451.101.1317.2618.9918.10IRD
303-U1305B303-U1305B-2H-2,42-43Working (W)10.85weak leach0.28-16.220.16Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus3781.23223.0045284.711.089.80499.182.38101.494.660.4449.245.2912.601.415.331.150.281.110.190.940.190.490.060.410.052.710.02Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q11.320.941.541.061.1818.0420.0919.00IRD
303-U1305B303-U1305B-2H-2,52-54Working (W)10.95weak leach0.27-13.620.26Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus2277.23404.8931800.4612.66212.260.50102.254.091.438.655.0111.671.305.131.070.261.070.150.860.150.430.060.360.052.38Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q7.950.891.501.051.1219.4920.4119.95IRD
303-U1305B303-U1305B-2H-2,62-63Working (W)11.05weak leach0.25-12.260.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2094.75263.9525013.717.76198.190.2385.823.870.9234.074.529.511.214.881.060.261.010.140.820.150.410.050.330.05Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q6.250.891.520.931.1820.0921.2120.62none
303-U1305B303-U1305B-2H-2,82-83Working (W)11.25weak leach0.28-15.300.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1927.45170.8221549.662.23187.970.3276.473.610.7219.574.1310.301.094.380.920.220.920.130.740.140.380.050.310.052.25Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q5.390.941.501.121.1220.5023.1621.61IRD
303-U1305B303-U1305B-2H-2,102-103Working (W)11.45weak leach0.27-16.970.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1975.80190.3812484.88135.350.1850.163.590.7918.203.939.201.054.290.920.210.880.130.740.130.380.050.310.041.92Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q3.120.951.501.041.1021.1324.3522.67IRD
303-U1305B303-U1305B-2H-2,119-120Working (W)11.62weak leach0.30-16.750.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2080.61140.3010968.44183.400.2132.382.740.6819.362.968.140.783.180.670.150.670.100.570.100.310.040.250.032.18Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q2.741.031.481.231.0821.9024.9523.53IRD
303-U1305B303-U1305B-2H-2,139-140Working (W)11.82weak leach0.29-20.770.18Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus4025.43105.0881929.981.111066.340.8211.181.07105.183.5120.324.7110.021.154.200.820.210.800.140.680.140.360.050.320.042.610.16Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q20.480.901.390.991.1923.3725.4124.58IRD
303-U1305B303-U1305B-2H-3,12-13Working (W)12.05weak leach0.29-13.540.18Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1702.01225.908626.879.12121.5636.873.820.8418.253.758.130.984.000.860.210.890.120.740.140.390.050.320.041.880.03Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q2.161.011.530.981.1325.1226.2725.68none
303-U1305B303-U1305B-2H-3,29-30Working (W)12.22weak leach0.30-15.070.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1755.97163.7516232.413.06147.070.2255.383.430.9626.453.979.741.024.070.860.210.840.120.700.130.370.050.320.042.70Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q4.060.991.441.111.1525.3927.6726.35IRD
303-U1305B303-U1305B-2H-3,49-50Working (W)12.42weak leach0.27-14.700.18Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2577.55158.2840308.26310.920.2496.113.440.6033.194.4610.441.134.570.950.220.900.130.720.130.370.050.300.042.120.03Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q10.080.861.461.071.1425.8128.7127.15IRD
303-U1305B303-U1305B-2H-3,69-70Working (W)12.62weak leach0.28-15.980.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2034.59134.4815729.92218.6938.802.810.6417.663.316.960.853.400.720.160.700.100.560.100.290.040.240.032.70Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q3.930.931.450.961.0926.3829.6027.97IRD
303-U1305B303-U1305B-2H-3,88-89Working (W)12.81weak leach0.29-16.000.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2324.65209.3520793.452.99217.040.3271.494.030.8619.904.5210.811.184.801.030.241.000.140.820.150.420.060.340.052.26Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q5.200.951.501.081.1227.0530.2428.73IRD
303-U1305B303-U1305B-2H-3,109-110Working (W)13.02weak leach0.28-13.610.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus247.502833.580.1711.08102.2696.110.381.466.201.390.4517.035.281.4118.955.5611.701.055.401.020.221.040.130.800.130.410.050.270.041.440.01Mass spectrometer (ICP-QMS), Thermo Scientific, Heidelberg, iCap Q0.710.751.501.111.0228.0030.8529.56none
303-U1305B303-U1305B-2H-3,122-123Working (W)13.15weak leach0.29-16.710.12Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2920.03185.6712260.96274.870.2633.933.620.9125.273.6610.240.994.030.860.190.880.120.750.140.390.050.320.052.78Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q3.071.061.511.241.0428.6031.0930.07IRD
303-U1305B303-U1305B-2H-3,137-138Working (W)13.30weak leach0.30-17.170.16Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus5583.20223.1180278.4113.90995.76250.701.9539.921.88130.515.340.4153.776.2714.241.576.121.300.291.260.191.090.210.560.080.480.075.130.13Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q20.070.991.431.041.0729.6931.4030.66IRD
303-U1305B303-U1305B-2H-4,2-3Working (W)13.45weak leach0.29-12.170.18Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2006.52232.9214319.264.49107.629.521.2766.044.420.6814.273.738.181.024.230.920.231.000.150.890.170.450.060.380.054.110.03Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q3.581.211.600.971.1030.9231.7831.35none
303-U1305B303-U1305B-2H-4,16-17Working (W)13.59weak leach0.26-13.040.28Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2114.59172.5012533.790.4410.2383.340.199.0444.754.291.8926.504.019.531.114.601.040.251.070.160.910.170.470.060.370.054.91Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q3.131.081.651.041.1131.2233.8232.14none
303-U1305B303-U1305B-2H-4,31-32Working (W)13.74weak leach0.28-14.450.16Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2469.98211.1324241.310.2710.52174.10129.120.280.274.730.9465.873.501.1022.033.317.360.913.520.780.190.750.110.640.120.320.040.260.043.660.02Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q6.060.951.540.981.1431.6135.4733.12IRD
303-U1305B303-U1305B-2H-4,46-4713.89forams-12.390.22Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus457.99710930.470.94410.722596.7612.803.1014.8240.673.7613.963.000.712.840.482.770.521.390.201.270.170.02Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q177.731.091.431.261.1532.0737.2434.14none
303-U1305B303-U1305B-2H-4,46-47Working (W)13.89weak leach0.27-12.280.28Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1075.6765.3823123.88118.450.2385.902.150.5811.732.486.110.652.610.560.130.540.080.440.080.230.030.190.03Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q5.780.961.481.111.1032.0737.2434.14none
303-U1305B303-U1305B-2H-4,46-47Working (W)13.89weak leach0.30-12.150.28Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus1890.62124.6544924.853.73223.85162.773.900.7420.584.5611.521.214.831.040.251.040.150.840.150.440.060.360.053.140.03Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q11.230.981.511.131.1132.0737.2434.14none
303-U1305B303-U1305B-4H-2,56-57Working (W)0.05weak leach0.27-18.110.26Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus2672.94221.5668171.780.9927.85605.41229.733.941.23220.333.0845.223.915.251.003.780.770.190.720.130.590.120.300.040.230.0229.330.05Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q17.040.711.600.611.22
303-U1305B303-U1305B-4H-2,56-57Working (W)0.09weak leach0.29-17.770.26Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus2497.33241.1141192.710.184.81206.0959.670.410.314.3011.060.61133.602.760.4127.273.306.250.853.150.650.140.570.080.450.080.220.030.170.025.020.02Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q10.300.661.420.861.11
105-647B 105-647B-1H-1,4-6Working (W)0.90weak leach0.28-18.890.26Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus3323.57312.6166918.9220.882434.81296.147.727.025.62279.694.5459.175.828.771.475.771.170.241.110.170.930.170.470.060.380.052.770.06Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q16.730.841.450.691.00
105-647B105-647B-1H-1,8-10Working (W)0.95weak leach0.28-20.490.17Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Kiel, Neptune Plus1669.7351447.148.51874.3595.252.942.890.43153.502.500.0926.073.415.640.873.270.650.120.660.090.540.100.270.040.230.032.260.03Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q12.860.871.400.760.85
105-647B105-647B-1H-1,89-91Working (W)1.49weak leach0.28-14.050.14Multiple collector inductively-coupled plasma mass spectrometer (MC-ICP-MS), Thermo Scientific, Heidelberg, Neptune Plus2849.34291.6732012.145.16230.790.27134.043.810.8925.363.959.161.084.330.960.210.970.140.790.150.390.050.300.042.34Mass spectrometer (ICP-QMS), Thermo Scientific, Cologne, iCap Q8.000.941.641.021.04