<?xml version="1.0" encoding="UTF-8"?><md:MetaData xmlns:md="http://www.pangaea.de/MetaData" version="2026-04-13">
<md:citation id="dataset951259">
<md:author id="dataset.author94337">
<md:lastName>Fontenla-Razzetto</md:lastName>
<md:firstName>Gabriela</md:firstName>
</md:author>
<md:author id="dataset.author94339">
<md:lastName>Tavares Wahren</md:lastName>
<md:firstName>Filipa</md:firstName>
</md:author>
<md:author id="dataset.author94340">
<md:lastName>Heilig</md:lastName>
<md:firstName>Dávid</md:firstName>
<md:orcid>0000-0002-9690-9643</md:orcid>
</md:author>
<md:author id="dataset.author94341">
<md:lastName>Heil</md:lastName>
<md:firstName>Bálint</md:firstName>
</md:author>
<md:author id="dataset.author94342">
<md:lastName>Kovacs</md:lastName>
<md:firstName>Gábor</md:firstName>
</md:author>
<md:author id="dataset.author75007">
<md:lastName>Feger</md:lastName>
<md:firstName>Karl-Heinz</md:firstName>
</md:author>
<md:author id="dataset.author94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:author>
<md:year>2022</md:year>
<md:title>Monitoring of sap velocity in hybrid poplar (Populus deltoides Bart. Ex Marsh x P.nigra L. "AF2") across contrasting sites and groundwater conditions, Kopcany, western Slowakia, 2019-2021</md:title>
<md:type id="dataset.reftype10" includeInCitation="true">dataset</md:type>
<md:URI>https://doi.org/10.1594/PANGAEA.951259</md:URI>
<md:dateTime>2022-11-25T08:34:22</md:dateTime>
<md:parentURI>https://doi.org/10.1594/PANGAEA.951255</md:parentURI>
</md:citation>
<md:abstract>This dataset contains measurements of sap velocity and sap flow from the study area of the project Dendromass4Europe. Three poplar SRC stands were selected according to a gradient of groundwater accessibility: S5-N (higher groundwater level), S4-D (low groundwater level), and S2-F (fluctuating groundwater level). On each of the selected sites four trees were selected according to the tree diameter at breast height distribution.The aim of the study was to quantify the water use of clone "AF2"  on sites with contrasting groundwater conditions. For the sap measurements a SFM1 sap device (Heat Ratio Method) was used at 20-minutes resolution in 2019 and 30-minutes resolution in 2021. In 2019 the sensors were installed in April and the measurements were conducted throughout the growing season until end of September. In 2021, measurements started in July and concluded in September. No measurements were conducted in growing season 2020.</md:abstract>
<md:reference dataciteRelType="References" group="210" id="ref116123" relationType="Related to" relationTypeId="12">
<md:author id="ref116123.author94337">
<md:lastName>Fontenla-Razzetto</md:lastName>
<md:firstName>Gabriela</md:firstName>
</md:author>
<md:author id="ref116123.author94339">
<md:lastName>Tavares Wahren</md:lastName>
<md:firstName>Filipa</md:firstName>
</md:author>
<md:author id="ref116123.author94340">
<md:lastName>Heilig</md:lastName>
<md:firstName>Dávid</md:firstName>
<md:orcid>0000-0002-9690-9643</md:orcid>
</md:author>
<md:author id="ref116123.author94341">
<md:lastName>Heil</md:lastName>
<md:firstName>Bálint</md:firstName>
</md:author>
<md:author id="ref116123.author94342">
<md:lastName>Kovacs</md:lastName>
<md:firstName>Gábor</md:firstName>
</md:author>
<md:author id="ref116123.author75007">
<md:lastName>Feger</md:lastName>
<md:firstName>Karl-Heinz</md:firstName>
</md:author>
<md:author id="ref116123.author94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:author>
<md:year>2022</md:year>
<md:title>Water Use of Hybrid Poplar (Populus deltoides Bart. ex Marsh x P. nigra L. “AF2”) Growing Across Contrasting Site and Groundwater Conditions in Western Slovakia</md:title>
<md:type id="ref116123.reftype1">journal article</md:type>
<md:source id="ref116123.journal2130" type="journal">BioEnergy Research</md:source>
<md:URI>https://doi.org/10.1007/s12155-022-10445-x</md:URI>
</md:reference>
<md:extent>
<md:geographic>
<md:westBoundLongitude>17.54941</md:westBoundLongitude>
<md:eastBoundLongitude>17.54941</md:eastBoundLongitude>
<md:southBoundLatitude>48.46908</md:southBoundLatitude>
<md:northBoundLatitude>48.46908</md:northBoundLatitude>
<md:meanLongitude>17.54941</md:meanLongitude>
<md:meanLatitude>48.46908</md:meanLatitude>
</md:geographic>
<md:temporal>
<md:minDateTime>2021-07-09T00:00:00</md:minDateTime>
<md:maxDateTime>2021-09-30T23:00:00</md:maxDateTime>
</md:temporal>
<md:topoType id="topotype8">time series</md:topoType>
</md:extent>
<md:project id="project4825" type="EU">
<md:label>D4EU-Dendromass4Europe</md:label>
<md:name>Securing Sustainable Dendromass Production with Poplar Plantations in European Rural Areas</md:name>
<md:URI>https://www.dendromass4europe.eu/</md:URI>
<md:institution id="project4825.inst20698">
<md:name>Technische Universität Dresden</md:name>
<md:optionalName>TUD</md:optionalName>
<md:URI>https://tu-dresden.de/</md:URI>
<md:ROR>https://ror.org/042aqky30</md:ROR>
</md:institution>
</md:project>
<md:award id="award1734">
<md:funder id="award1734.funder20475" semanticURI="doi:10.13039/501100007601">
<md:name>Horizon 2020</md:name>
<md:optionalName>H2020</md:optionalName>
<md:URI>https://ec.europa.eu/programmes/horizon2020/</md:URI>
<md:crossrefFunderId>https://doi.org/10.13039/501100007601</md:crossrefFunderId>
</md:funder>
<md:number>745874</md:number>
<md:title>Dendromass4Europe</md:title>
<md:URI>https://doi.org/10.3030/745874</md:URI>
</md:award>
<md:event displayTypeName="Event" id="event3031249" typeName="Generic Event">
<md:label>SK-Land-2018-2022_Kopcany_S5-N</md:label>
<md:latitude>48.46908</md:latitude>
<md:longitude>17.54941</md:longitude>
<md:location id="event3031249.term30120">
<md:name>Slovakia, Europe</md:name>
</md:location>
<md:dateTime>2018-06-01T00:00:00</md:dateTime>
<md:dateTime2>2022-05-31T00:00:00</md:dateTime2>
<md:campaign displayTypeName="Campaign" id="event3031249.campaign3373692" legacyId="event3031249.campaign49224" typeName="Generic Campaign">
<md:label>SK-Land-2018-2022_Kopcany</md:label>
<md:name warning="deprecated">SK-Land-2018-2022_Kopcany</md:name>
<md:dateTime>2018-06-01T00:00:00</md:dateTime>
<md:start warning="deprecated">2018-06-01</md:start>
<md:dateTime2>2022-05-31T00:00:00</md:dateTime2>
<md:end warning="deprecated">2022-05-31</md:end>
<md:basis id="event3031249.campaign3373692.basis40">
<md:name>Sampling on land</md:name>
</md:basis>
<md:responsible>Fontenla-Razzetto, Gabriela</md:responsible>
<md:chiefScientist warning="deprecated">Fontenla-Razzetto, Gabriela</md:chiefScientist>
</md:campaign>
<md:basis id="event3031249.basis40">
<md:name>Sampling on land</md:name>
</md:basis>
<md:method id="event3031249.method10690">
<md:name>Monitoring</md:name>
<md:optionalName>MON</md:optionalName>
</md:method>
</md:event>
<md:size unit="data points">18144</md:size>
<md:license id="license21">
<md:label>CC-BY-4.0</md:label>
<md:name>Creative Commons Attribution 4.0 International</md:name>
<md:URI>https://creativecommons.org/licenses/by/4.0/</md:URI>
</md:license>
<md:comment>Empty cells represent missing values</md:comment>
<md:matrixColumn col="0" id="col0.ds14775999" source="data" type="string">
<md:parameter id="col0.ds14775999.param48491">
<md:name>Site</md:name>
<md:shortName>Site</md:shortName>
<md:term endOffset="4" fragment="1" id="col0.ds14775999.param48491.term37810" startOffset="0" terminologyId="18" terminologyLabel="PAN-MicroBio">
<md:name>site</md:name>
</md:term>
</md:parameter>
<md:PI id="col0.ds14775999.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:caption>Site</md:caption>
</md:matrixColumn>
<md:matrixColumn behaviour="4" col="1" format="yyyy-MM-dd'T'HH:mm" id="col1.ds14776000" source="geocode" type="datetime">
<md:parameter id="col1.ds14776000.geocode1599">
<md:name>DATE/TIME</md:name>
<md:shortName>Date/Time</md:shortName>
<md:URI>http://en.wikipedia.org/wiki/ISO_8601</md:URI>
<md:term endOffset="9" fragment="2" id="col1.ds14776000.geocode1599.term43975" semanticURI="http://qudt.org/1.1/vocab/quantity#Time" startOffset="5" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Time</md:name>
<md:optionalName>T</md:optionalName>
<md:URI>http://dbpedia.org/resource/Time</md:URI>
</md:term>
</md:parameter>
<md:PI id="col1.ds14776000.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:caption>Date/Time</md:caption>
</md:matrixColumn>
<md:matrixColumn col="2" format="##0.000000000" id="col2.ds14776001" source="data" type="numeric">
<md:parameter id="col2.ds14776001.param516116">
<md:name>Sap velocity</md:name>
<md:shortName>Sap vel</md:shortName>
<md:unit>cm/h</md:unit>
<md:term id="col2.ds14776001.param516116.term43876" semanticURI="http://qudt.org/1.1/vocab/quantity#LinearVelocity" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Linear Velocity</md:name>
<md:URI>http://dbpedia.org/resource/Velocity</md:URI>
</md:term>
</md:parameter>
<md:method id="col2.ds14776001.method15090">
<md:name>Sap flow sensors SFM1 (Heat Ratio Method), two measuring needles and one line heater, 35 mm length (ICT International)</md:name>
</md:method>
<md:PI id="col2.ds14776001.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:comment>at inner sensor</md:comment>
<md:caption>Sap vel [cm/h] (at inner sensor, Sap flow sen...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="3" format="##0.000000000" id="col3.ds14776002" source="data" type="numeric">
<md:parameter id="col3.ds14776002.param516116">
<md:name>Sap velocity</md:name>
<md:shortName>Sap vel</md:shortName>
<md:unit>cm/h</md:unit>
<md:term id="col3.ds14776002.param516116.term43876" semanticURI="http://qudt.org/1.1/vocab/quantity#LinearVelocity" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Linear Velocity</md:name>
<md:URI>http://dbpedia.org/resource/Velocity</md:URI>
</md:term>
</md:parameter>
<md:method id="col3.ds14776002.method15090">
<md:name>Sap flow sensors SFM1 (Heat Ratio Method), two measuring needles and one line heater, 35 mm length (ICT International)</md:name>
</md:method>
<md:PI id="col3.ds14776002.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:comment>at outer sensor</md:comment>
<md:caption>Sap vel [cm/h] (at outer sensor, Sap flow sen...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="4" format="##0.000000000" id="col4.ds14776003" source="data" type="numeric">
<md:parameter id="col4.ds14776003.param516116">
<md:name>Sap velocity</md:name>
<md:shortName>Sap vel</md:shortName>
<md:unit>cm/h</md:unit>
<md:term id="col4.ds14776003.param516116.term43876" semanticURI="http://qudt.org/1.1/vocab/quantity#LinearVelocity" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Linear Velocity</md:name>
<md:URI>http://dbpedia.org/resource/Velocity</md:URI>
</md:term>
</md:parameter>
<md:method id="col4.ds14776003.method15090">
<md:name>Sap flow sensors SFM1 (Heat Ratio Method), two measuring needles and one line heater, 35 mm length (ICT International)</md:name>
</md:method>
<md:PI id="col4.ds14776003.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:comment>Mean velocity, inner and outer sensor</md:comment>
<md:caption>Sap vel [cm/h] (Mean velocity, inner and oute...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="5" format="####0.000000000" id="col5.ds14776004" source="data" type="numeric">
<md:parameter id="col5.ds14776004.param516117">
<md:name>Flow rate</md:name>
<md:shortName>Flow rate</md:shortName>
<md:unit>cm**3/h</md:unit>
<md:term endOffset="9" fragment="1" id="col5.ds14776004.param516117.term1074818" semanticURI="urn:obo:pato:term:0001574" startOffset="0" terminologyId="14" terminologyLabel="PATO">
<md:name>flow rate</md:name>
<md:URI>http://purl.obolibrary.org/obo/PATO_0001574</md:URI>
</md:term>
<md:term id="col5.ds14776004.param516117.term43985" semanticURI="http://qudt.org/1.1/vocab/quantity#VolumePerUnitTime" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Volume per Unit Time</md:name>
</md:term>
</md:parameter>
<md:method id="col5.ds14776004.method15090">
<md:name>Sap flow sensors SFM1 (Heat Ratio Method), two measuring needles and one line heater, 35 mm length (ICT International)</md:name>
</md:method>
<md:PI id="col5.ds14776004.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:comment>at inner sensor</md:comment>
<md:caption>Flow rate [cm**3/h] (at inner sensor, Sap flow sen...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="6" format="####0.00000000" id="col6.ds14776005" source="data" type="numeric">
<md:parameter id="col6.ds14776005.param516117">
<md:name>Flow rate</md:name>
<md:shortName>Flow rate</md:shortName>
<md:unit>cm**3/h</md:unit>
<md:term endOffset="9" fragment="1" id="col6.ds14776005.param516117.term1074818" semanticURI="urn:obo:pato:term:0001574" startOffset="0" terminologyId="14" terminologyLabel="PATO">
<md:name>flow rate</md:name>
<md:URI>http://purl.obolibrary.org/obo/PATO_0001574</md:URI>
</md:term>
<md:term id="col6.ds14776005.param516117.term43985" semanticURI="http://qudt.org/1.1/vocab/quantity#VolumePerUnitTime" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Volume per Unit Time</md:name>
</md:term>
</md:parameter>
<md:method id="col6.ds14776005.method15090">
<md:name>Sap flow sensors SFM1 (Heat Ratio Method), two measuring needles and one line heater, 35 mm length (ICT International)</md:name>
</md:method>
<md:PI id="col6.ds14776005.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:comment>at outer sensor</md:comment>
<md:caption>Flow rate [cm**3/h] (at outer sensor, Sap flow sen...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="7" format="####0.00000000" id="col7.ds14776006" source="data" type="numeric">
<md:parameter id="col7.ds14776006.param516117">
<md:name>Flow rate</md:name>
<md:shortName>Flow rate</md:shortName>
<md:unit>cm**3/h</md:unit>
<md:term endOffset="9" fragment="1" id="col7.ds14776006.param516117.term1074818" semanticURI="urn:obo:pato:term:0001574" startOffset="0" terminologyId="14" terminologyLabel="PATO">
<md:name>flow rate</md:name>
<md:URI>http://purl.obolibrary.org/obo/PATO_0001574</md:URI>
</md:term>
<md:term id="col7.ds14776006.param516117.term43985" semanticURI="http://qudt.org/1.1/vocab/quantity#VolumePerUnitTime" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Volume per Unit Time</md:name>
</md:term>
</md:parameter>
<md:method id="col7.ds14776006.method15090">
<md:name>Sap flow sensors SFM1 (Heat Ratio Method), two measuring needles and one line heater, 35 mm length (ICT International)</md:name>
</md:method>
<md:PI id="col7.ds14776006.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:comment>sum of contributions of each wood ring to flow rate</md:comment>
<md:caption>Flow rate [cm**3/h] (sum of contributions of each ...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="8" format="###0.000000000" id="col8.ds14776007" source="data" type="numeric">
<md:parameter id="col8.ds14776007.param516117">
<md:name>Flow rate</md:name>
<md:shortName>Flow rate</md:shortName>
<md:unit>cm**3/h</md:unit>
<md:term endOffset="9" fragment="1" id="col8.ds14776007.param516117.term1074818" semanticURI="urn:obo:pato:term:0001574" startOffset="0" terminologyId="14" terminologyLabel="PATO">
<md:name>flow rate</md:name>
<md:URI>http://purl.obolibrary.org/obo/PATO_0001574</md:URI>
</md:term>
<md:term id="col8.ds14776007.param516117.term43985" semanticURI="http://qudt.org/1.1/vocab/quantity#VolumePerUnitTime" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Volume per Unit Time</md:name>
</md:term>
</md:parameter>
<md:method id="col8.ds14776007.method81">
<md:name>Estimated</md:name>
</md:method>
<md:PI id="col8.ds14776007.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:comment>flow rate in the sapwood area not covered by the sensor</md:comment>
<md:caption>Flow rate [cm**3/h] (flow rate in the sapwood area...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="9" format="####0.000000000" id="col9.ds14776008" source="data" type="numeric">
<md:parameter id="col9.ds14776008.param516117">
<md:name>Flow rate</md:name>
<md:shortName>Flow rate</md:shortName>
<md:unit>cm**3/h</md:unit>
<md:term endOffset="9" fragment="1" id="col9.ds14776008.param516117.term1074818" semanticURI="urn:obo:pato:term:0001574" startOffset="0" terminologyId="14" terminologyLabel="PATO">
<md:name>flow rate</md:name>
<md:URI>http://purl.obolibrary.org/obo/PATO_0001574</md:URI>
</md:term>
<md:term id="col9.ds14776008.param516117.term43985" semanticURI="http://qudt.org/1.1/vocab/quantity#VolumePerUnitTime" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Volume per Unit Time</md:name>
</md:term>
</md:parameter>
<md:method id="col9.ds14776008.method81">
<md:name>Estimated</md:name>
</md:method>
<md:PI id="col9.ds14776008.pi94338">
<md:lastName>Julich</md:lastName>
<md:firstName>Stefan</md:firstName>
<md:eMail>Stefan.Julich@hnee.de</md:eMail>
</md:PI>
<md:comment>total flow rate for the entire sapwood</md:comment>
<md:caption>Flow rate [cm**3/h] (total flow rate for the entir...)</md:caption>
</md:matrixColumn>
<md:status>
<md:curationLevel id="curlevel30">
<md:label>CurationLevelC</md:label>
<md:name>Enhanced curation</md:name>
<md:URI>https://wiki.pangaea.de/wiki/Curation_levels</md:URI>
</md:curationLevel>
</md:status>
<md:keywords>
<md:techKeyword type="autoGenerated">citable</md:techKeyword>
<md:techKeyword type="autoGenerated">author75007</md:techKeyword>
<md:techKeyword type="autoGenerated">author94337</md:techKeyword>
<md:techKeyword type="autoGenerated">author94338</md:techKeyword>
<md:techKeyword type="autoGenerated">author94339</md:techKeyword>
<md:techKeyword type="autoGenerated">author94340</md:techKeyword>
<md:techKeyword type="autoGenerated">author94341</md:techKeyword>
<md:techKeyword type="autoGenerated">author94342</md:techKeyword>
<md:techKeyword type="autoGenerated">award1734</md:techKeyword>
<md:techKeyword type="autoGenerated">basis40</md:techKeyword>
<md:techKeyword type="autoGenerated">campaign3373692</md:techKeyword>
<md:techKeyword type="autoGenerated">campaign49224</md:techKeyword>
<md:techKeyword type="autoGenerated">curlevel30</md:techKeyword>
<md:techKeyword type="autoGenerated">event3031249</md:techKeyword>
<md:techKeyword type="autoGenerated">funder20475</md:techKeyword>
<md:techKeyword type="autoGenerated">geocode1599</md:techKeyword>
<md:techKeyword type="autoGenerated">geocode1600</md:techKeyword>
<md:techKeyword type="autoGenerated">geocode1601</md:techKeyword>
<md:techKeyword type="autoGenerated">inst20698</md:techKeyword>
<md:techKeyword type="autoGenerated">journal2130</md:techKeyword>
<md:techKeyword type="autoGenerated">license21</md:techKeyword>
<md:techKeyword type="autoGenerated">method10690</md:techKeyword>
<md:techKeyword type="autoGenerated">method15090</md:techKeyword>
<md:techKeyword type="autoGenerated">method81</md:techKeyword>
<md:techKeyword type="autoGenerated">param48491</md:techKeyword>
<md:techKeyword type="autoGenerated">param516116</md:techKeyword>
<md:techKeyword type="autoGenerated">param516117</md:techKeyword>
<md:techKeyword type="autoGenerated">pi94338</md:techKeyword>
<md:techKeyword type="autoGenerated">project4825</md:techKeyword>
<md:techKeyword type="autoGenerated">ref116123</md:techKeyword>
<md:techKeyword type="autoGenerated">term1074818</md:techKeyword>
<md:techKeyword type="autoGenerated">term30120</md:techKeyword>
<md:techKeyword type="autoGenerated">term37810</md:techKeyword>
<md:techKeyword type="autoGenerated">term43876</md:techKeyword>
<md:techKeyword type="autoGenerated">term43975</md:techKeyword>
<md:techKeyword type="autoGenerated">term43985</md:techKeyword>
<md:techKeyword type="autoGenerated">topotype8</md:techKeyword>
</md:keywords>
<md:technicalInfo>
<md:entry key="xmlLastModified" value="2026-04-30T21:28:30Z"/>
<md:entry key="lastModified" value="2022-12-07T07:31:09"/>
<md:entry key="filename" value="D4EU_sap-vel-mon"/>
<md:entry key="mimeType" value="text/tab-separated-values"/>
<md:entry key="status" value="published"/>
<md:entry key="status_num" value="4"/>
<md:entry key="DOIRegistryStatus" value="registered"/>
<md:entry key="DOIRegistryStatus_num" value="4"/>
<md:entry key="DOIRegistrationDate" value="2023-01-05T01:04:43"/>
<md:entry key="hierarchyLevel" value="child"/>
<md:entry key="loginOption" value="unrestricted"/>
<md:entry key="loginOption_num" value="1"/>
</md:technicalInfo>
</md:MetaData>