Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Veit, Andreas; Miller, Hubert (2003): Geochemical analysis of volcanic rocks from the Antarctic Peninsula [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.95059

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Veit, Andreas (2002): Vulkanologie und Geochemie pliozäner bis rezenter Vulkanite beiderseits der Bransfield-Straße/West-Antarktis (Volcanology and geochemistry of Pliocene to Recent volcanics on both sides of the Bransfield-Strait / West-Antarctica). Berichte zur Polar- und Meeresforschung = Reports on Polar and Marine Research, 420, 177 pp, https://doi.org/10.2312/BzPM_0420_2002
Coverage:
Median Latitude: -65.016000 * Median Longitude: -60.124000 * South-bound Latitude: -65.080000 * West-bound Longitude: -60.250000 * North-bound Latitude: -64.950000 * East-bound Longitude: -60.030000
Minimum Elevation: 25.0 m * Maximum Elevation: 359.9 m
Event(s):
Akelundh_N * Latitude: -65.050000 * Longitude: -60.180000 * Location: Akelundh Nunatak * Method/Device: Geological sample (GEOS)
Bruce_N * Latitude: -65.080000 * Longitude: -60.250000 * Elevation: 359.8 m * Location: Bruce Nunatak * Campaign: GAP98 * Basis: Sampling on land * Method/Device: Geological sample (GEOS)
Larsen_N * Latitude: -64.970000 * Longitude: -60.080000 * Elevation: 25.0 m * Location: Larsen Nunatak * Campaign: GAP98 * Basis: Sampling on land * Method/Device: Geological sample (GEOS)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEvent
2Sample code/labelSample labelMiller, Hubert
3Silicon dioxideSiO2%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
4Aluminium oxideAl2O3%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
5Iron oxide, Fe2O3Fe2O3%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
6Magnesium oxideMgO%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
7Calcium oxideCaO%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
8Sodium oxideNa2O%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
9Potassium oxideK2O%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
10Manganese oxideMnO%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
11Titanium dioxideTiO2%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
12Phosphorus pentoxideP2O5%Miller, HubertInductively coupled plasma atomic emission spectroscope (ICP-AES)
13ScandiumScmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
14VanadiumVmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
15ChromiumCrmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
16CobaltComg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
17NickelNimg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
18CopperCumg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
19ZincZnmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
20GalliumGamg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
21RubidiumRbmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
22StrontiumSrmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
23YttriumYmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
24ZirconiumZrmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
25NiobiumNbmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
26BariumBamg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
27HafniumHfmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
28TantalumTamg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
29LeadPbmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
30GoldAung/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
31SilverAgmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
32ArsenicAsmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
33BromineBrmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
34CaesiumCsmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
35MercuryHgmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
36IridiumIrng/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
37MolybdenumMomg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
38AntimonySbmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
39SeleniumSemg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
40ThoriumThmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
41UraniumUmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
42TungstenWmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
43LanthanumLamg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
44CeriumCemg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
45NeodymiumNdmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
46SamariumSmmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
47EuropiumEumg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
48TerbiumTbmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
49YtterbiumYbmg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
50LutetiumLumg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
51BismuthBimg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
52BerylliumBemg/kgMiller, HubertInductively coupled plasma - mass spectrometry (ICP-MS)
Size:
670 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML