Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Logemann, Anna Elisabeth; Röhrs, Steffen; Brockmeyer, Berit (2022): Determination of hydrophobic organic contaminants in sediment fines and bulk sediment [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.950287

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2022-11-08DOI registered: 2023-01-09

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Abstract:
We investigated 41 hydrophobic organic contaminants set of sediment samples (from 16 monitoring stations) taken in the North Sea (German EEZ). The samples were taken by the German Federal Maritime and Hydrographic Agency (BSH) in June 2016 on the RV Atair (Cruise AT239) using a box corer. Bulk sediment samples were analyzed for hydrophobic organic contaminants unsing micowave extraction, column clean-up, size-exclusion chromatography followed by GC-MS/MS analysis. Bulk sediment samples were additionally wet-sieved to seperate the sediment fine fraction (< 63 µm) which was analyzed accordingly. This study provides a comprehensive overview of hydrophobic organic contaminant concentrations in sediment fines (< 63 µm) for the German EEZ. The results indicate that the improved wet-sieving procedure is capable of physically normalizing the concentrations of the investigated contaminants and is useful for the comparison of different sediment types.
Related to:
Bundesanstalt für Gewässerkunde (2021): Meeresumweltdatenbank (MUDAB). Version 1.5.2 (13.08.2021). https://geoportal.bafg.de/MUDABAnwendung/
Witt, Gesine; Brockmeyer, Berit; Niehus, Nora Claire; Reininghaus, Mathias (2017): Organic contaminants (PAH, PCB and DDT) in sediments and porewater of the German Exclusive Economic Zone sampled in 2013/2014 [dataset]. Hochschule für Angewandte Wissenschaften Hamburg - Hamburg University of Applied Sciences and Bundesamt für Seeschiffahrt und Hydrographie, Hamburg, PANGAEA, https://doi.org/10.1594/PANGAEA.875181
Funding:
Federal Ministry of Education and Research (BMBF), grant/award no. 03F0669A: North Sea Observation and Assessment of Habitats
Coverage:
Median Latitude: 54.623444 * Median Longitude: 6.920513 * South-bound Latitude: 53.673300 * West-bound Longitude: 4.250000 * North-bound Latitude: 55.766700 * East-bound Longitude: 8.383300
Date/Time Start: 2016-05-24T11:10:00 * Date/Time End: 2016-05-31T16:15:00
Minimum DEPTH, sediment/rock: 0.02 m * Maximum DEPTH, sediment/rock: 0.02 m
Event(s):
AT239_BL4 * Latitude: 54.250000 * Longitude: 7.800000 * Date/Time: 2016-05-30T15:40:00 * Elevation: -27.0 m * Location: North Sea * Campaign: Atair239 (AT239) * Basis: Atair * Method/Device: Box corer (BC)
AT239_EIDER * Latitude: 54.225000 * Longitude: 8.383300 * Date/Time: 2016-05-31T09:55:00 * Elevation: -13.0 m * Location: North Sea * Campaign: Atair239 (AT239) * Basis: Atair * Method/Device: Box corer (BC)
AT239_ES1 * Latitude: 53.673300 * Longitude: 6.500000 * Date/Time: 2016-05-30T06:35:00 * Elevation: -21.0 m * Location: North Sea * Campaign: Atair239 (AT239) * Basis: Atair * Method/Device: Box corer (BC)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventLogemann, Anna Elisabeth
2Station labelStationLogemann, Anna Elisabeth
3Sample code/labelSample labelLogemann, Anna Elisabeth
4Elevation of eventElevationmLogemann, Anna Elisabeth
5DEPTH, sediment/rockDepth sedmLogemann, Anna ElisabethGeocode
6Latitude of eventLatitudeLogemann, Anna Elisabeth
7Longitude of eventLongitudeLogemann, Anna Elisabeth
8DATE/TIMEDate/TimeLogemann, Anna ElisabethGeocode – UTC
9Carbon, organic, total, per unit sediment massTOC/sedmg/gLogemann, Anna ElisabethCarbon and nitrogen and sulfur (CNS) isotope element analyzer, Elementar, Vario EL IIImeasured in sediment, grain size fraction <63 µm. The TOC analysis was carried out with a VarioEL (Elementar, Germany) in CN mode at 950 degC. The dried and homogenized samples were weighted in silver capsules, acidified with 200 microL of 2 M HCl (32%) and placed in an oven for 3 h at 110 degC to remove the inorganic carbon.
10Acenaphthene, per unit sediment massAcenaphthene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.21 ng/g, limit of quantification: 0.56 ng/g
11Acenaphthylene, per unit sediment massAcenaphthylene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.17 ng/g, limit of quantification: 0.45 ng/g
12Anthracene, per unit sediment massAnthracene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.12 ng/g, limit of quantification: 0.33 ng/g
13Benz(a)anthracene, per unit sediment massBenz(a)anthracene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.31 ng/g, limit of quantification: 0.79 ng/g
14Benzo(a)pyrene, per unit sediment massBenzo(a)pyrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.35 ng/g, limit of quantification: 0.91 ng/g
15Benzo(b)fluoranthene, per unit sediment massBenzo(b)fluoranthene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.31 ng/g, limit of quantification: 0.80 ng/g
16Benzo(g,h,i)perylene, per unit sediment massBenzo(g,h,i)perylene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.05 ng/g, limit of quantification: 0.15 ng/g
17Chrysene/Triphenylene, per unit sediment massChrysene/Triphenylene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.08 ng/g, limit of quantification: 0.20 ng/g
18Dibenz(a,h)anthracene, per unit sediment massDibenz(ah)anthracene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.29 ng/g, limit of quantification: 0.75 ng/g
19Fluoranthene, per unit sediment massFluoranthene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.11 ng/g, limit of quantification: 0.30 ng/g
20Fluorene, per unit sediment massFluorene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.18 ng/g, limit of quantification: 0.47 ng/g
21Indeno(1,2,3-cd)pyrene, per unit sediment massIndeno(1,2,3-cd)pyr/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.33 ng/g, limit of quantification: 0.86 ng/g
22Naphthalene, per unit sediment massNaphth/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.26 ng/g, limit of quantification: 0.50 ng/g
23Phenanthrene, per unit sediment massPhenanthrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.10 ng/g, limit of quantification: 0.28 ng/g
24Pyrene, per unit sediment massPyrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.21 ng/g, limit of quantification: 0.55 ng/g
251-Methylnaphthalene, per unit sediment mass1-Methylnaphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.10 ng/g, limit of quantification: 0.28 ng/g
262-Methylnaphthalene, per unit sediment mass2-Methylnaphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.17 ng/g, limit of quantification: 0.44 ng/g
273-Methylphenanthrene, per unit sediment mass3-Methylphenanthrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.45 ng/g, limit of quantification: 1.2 ng/g
282,6-Dimethylnaphthalene, per unit sediment mass2,6-Dimethylnaphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.07 ng/g, limit of quantification: 0.19 ng/g
293,6-Dimethylphenanthrene, per unit sediment mass3,6-Dimethylphenanthrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.29 ng/g, limit of quantification: 0.77 ng/g
302,3,5-Trimethylnaphthalene, per unit sediment mass2,3,5-Trimethylnaphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.04 ng/g, limit of quantification: 0.10 ng/g
311,2,8-Trimethylphenanthrene, per unit sediment mass1,2,8-Trimethylphenanthrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, grain size fraction <63 µm, limit of detection: 0.09 ng/g, limit of quantification: 0.24 ng/g
32Dimethylated Naphthalenes, per unit sediment massDimethylated Naphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, grain size fraction <63 µm, limit of detection: 0.070 ng/g, limit of quantification: 0.19 ng/g
33Trimethylated Naphthalenes, per unit sediment massTrimethylated Naphthalenes/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, grain size fraction <63 µm, limit of detection: 0.25 ng/g, limit of quantification: 0.64 ng/g
34Methylated Phenantrenes, per unit sediment massMethylated Phenantrenes/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, grain size fraction <63 µm, limit of detection: 0.45 ng/g, limit of quantification: 1.2 ng/g
35Dimethylated Phenantrenes, per unit sediment massDimethylated Phenantrenes/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, grain size fraction <63 µm, limit of detection: 0.29 ng/g, limit of quantification: 0.76 ng/g
36Trimethylated Phenantrenes, per unit sediment massTrimethylated Phenantrenes/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, grain size fraction <63 µm, limit of detection: 0.09 ng/g, limit of quantification: 0.24 ng/g
372,4,4'-Trichlorobiphenyl, per unit sediment mass2,4,4-Trichlorobiphenyl/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.004 ng/g, limit of quantification: 0.01 ng/g
382,2',5,5'-Tetrachlorobiphenyl, per unit sediment massC12H6Cl4/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.001 ng/g, limit of quantification: 0.002 ng/g
392,2',4,5,5'-Pentachlorobiphenyl, per unit sediment massC12H5Cl5/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.005 ng/g, limit of quantification: 0.01 ng/g
402,3',4,4,5'-Pentachlorobiphenyl, per unit sediment mass2,3',4,4,5'-Pentachlorobiphenyl/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.003 ng/g, limit of quantification: 0.007 ng/g
412,2',3,4,4',5'-Hexachlorobiphenyl, per unit sediment massC12H4Cl6/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.002 ng/g, limit of quantification: 0.005 ng/g
422,2',4,4',5,5'-Hexachlorobiphenyl, per unit sediment massC12H4Cl6/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.006 ng/g, limit of quantification: 0.01 ng/g
432,2',3,4,4',5,5'-Heptachlorobiphenyl, per unit sediment massC12H3Cl7/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.005 ng/g, limit of quantification: 0.01 ng/g
44alpha-Hexachlorocyclohexane, per unit sediment massa-HCH/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.01 ng/g, limit of quantification: 0.02 ng/g
45beta-Hexachlorocyclohexane, per unit sediment massb-HCH/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.005 ng/g, limit of quantification: 0.01 ng/g
46gamma-Hexachlorocyclohexane, per unit sediment massg-HCH/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.004 ng/g, limit of quantification: 0.01 ng/g
47Hexachlorobenzene, per unit sediment massHCB/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.002 ng/g, limit of quantification: 0.006 ng/g
48para,para-Dichlorodiphenyldichloroethane, per unit sediment masspp-DDD/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.007 ng/g, limit of quantification: 0.01 ng/g
49para,para-Dichlorodiphenyldichloroethylene, per unit sediment masspp-DDE/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.002 ng/g, limit of quantification: 0.005 ng/g
50para,para-Dichlorodiphenyltrichloroethane, per unit sediment masspp-DDT/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, grain size fraction <63 µm, limit of detection: 0.008 ng/g, limit of quantification: 0.01 ng/g
51Carbon, organic, total, per unit sediment massTOC/sedmg/gLogemann, Anna ElisabethCarbon and nitrogen and sulfur (CNS) isotope element analyzer, Elementar, Vario EL IIImeasured in sediment, total. The TOC analysis was carried out with a VarioEL (Elementar, Germany) in CN mode at 950 degC. The dried and homogenized samples were weighted in silver capsules, acidified with 200 microL of 2 M HCl (32%) and placed in an oven for 3 h at 110 degC to remove the inorganic carbon.
52Size fraction < 0.020 mm<20 µm%Logemann, Anna ElisabethLaser Particle Analyser, Fritsch GmbH, Analysette 22measured in sediment, total
53Size fraction < 0.063 mm, mud, silt+clay<63 µm%Logemann, Anna ElisabethLaser Particle Analyser, Fritsch GmbH, Analysette 22measured in sediment, total
54Size fraction < 0.200 mm<200 µm%Logemann, Anna ElisabethLaser Particle Analyser, Fritsch GmbH, Analysette 22measured in sediment, total
55Size fraction < 2.0 mm<2000 µm%Logemann, Anna ElisabethLaser Particle Analyser, Fritsch GmbH, Analysette 22measured in sediment, total
56Acenaphthene, per unit sediment massAcenaphthene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.21 ng/g, limit of quantification: 0.56 ng/g
57Acenaphthylene, per unit sediment massAcenaphthylene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.17 ng/g, limit of quantification: 0.45 ng/g
58Anthracene, per unit sediment massAnthracene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.12 ng/g, limit of quantification: 0.33 ng/g
59Benz(a)anthracene, per unit sediment massBenz(a)anthracene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.31 ng/g, limit of quantification: 0.79 ng/g
60Benzo(a)pyrene, per unit sediment massBenzo(a)pyrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.35 ng/g, limit of quantification: 0.91 ng/g
61Benzo(b)fluoranthene, per unit sediment massBenzo(b)fluoranthene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.31 ng/g, limit of quantification: 0.80 ng/g
62Benzo(g,h,i)perylene, per unit sediment massBenzo(g,h,i)perylene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.05 ng/g, limit of quantification: 0.15 ng/g
63Chrysene/Triphenylene, per unit sediment massChrysene/Triphenylene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.08 ng/g, limit of quantification: 0.20 ng/g
64Dibenz(a,h)anthracene, per unit sediment massDibenz(ah)anthracene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.29 ng/g, limit of quantification: 0.75 ng/g
65Fluoranthene, per unit sediment massFluoranthene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.11 ng/g, limit of quantification: 0.30 ng/g
66Fluorene, per unit sediment massFluorene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.18 ng/g, limit of quantification: 0.47 ng/g
67Indeno(1,2,3-cd)pyrene, per unit sediment massIndeno(1,2,3-cd)pyr/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.33 ng/g, limit of quantification: 0.86 ng/g
68Naphthalene, per unit sediment massNaphth/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.26 ng/g, limit of quantification: 0.50 ng/g
69Phenanthrene, per unit sediment massPhenanthrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.10 ng/g, limit of quantification: 0.28 ng/g
70Pyrene, per unit sediment massPyrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.21 ng/g, limit of quantification: 0.55 ng/g
711-Methylnaphthalene, per unit sediment mass1-Methylnaphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.10 ng/g, limit of quantification: 0.28 ng/g
722-Methylnaphthalene, per unit sediment mass2-Methylnaphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.17 ng/g, limit of quantification: 0.44 ng/g
733-Methylphenanthrene, per unit sediment mass3-Methylphenanthrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.45 ng/g, limit of quantification: 1.2 ng/g
742,6-Dimethylnaphthalene, per unit sediment mass2,6-Dimethylnaphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.07 ng/g, limit of quantification: 0.19 ng/g
753,6-Dimethylphenanthrene, per unit sediment mass3,6-Dimethylphenanthrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.29 ng/g, limit of quantification: 0.77 ng/g
762,3,5-Trimethylnaphthalene, per unit sediment mass2,3,5-Trimethylnaphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.04 ng/g, limit of quantification: 0.10 ng/g
771,2,8-Trimethylphenanthrene, per unit sediment mass1,2,8-Trimethylphenanthrene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)measured in sediment, total, limit of detection: 0.09 ng/g, limit of quantification: 0.24 ng/g
78Dimethylated Naphthalenes, per unit sediment massDimethylated Naphthalene/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, total, limit of detection: 0.070 ng/g, limit of quantification: 0.19 ng/g
79Trimethylated Naphthalenes, per unit sediment massTrimethylated Naphthalenes/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, total, limit of detection: 0.025 ng/g, limit of quantification: 0.64 ng/g
80Methylated Phenantrenes, per unit sediment massMethylated Phenantrenes/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, total, limit of detection: 0.45 ng/g, limit of quantification: 1.2 ng/g
81Dimethylated Phenantrenes, per unit sediment massDimethylated Phenantrenes/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, total, limit of detection: 0.29 ng/g, limit of quantification: 0.76 ng/g
82Trimethylated Phenantrenes, per unit sediment massTrimethylated Phenantrenes/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS/MS system (GC CP-3800, Varian) coupled to Varian 1200 (Varian)sum, measured in sediment, total, limit of detection: 0.09 ng/g, limit of quantification: 0.24 ng/g
832,4,4'-Trichlorobiphenyl, per unit sediment mass2,4,4-Trichlorobiphenyl/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.004 ng/g, limit of quantification: 0.01 ng/g
842,2',5,5'-Tetrachlorobiphenyl, per unit sediment massC12H6Cl4/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.001 ng/g, limit of quantification: 0.002 ng/g
852,2',4,5,5'-Pentachlorobiphenyl, per unit sediment massC12H5Cl5/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.005 ng/g, limit of quantification: 0.01 ng/g
862,3',4,4,5'-Pentachlorobiphenyl, per unit sediment mass2,3',4,4,5'-Pentachlorobiphenyl/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.003 ng/g, limit of quantification: 0.007 ng/g
872,2',3,4,4',5'-Hexachlorobiphenyl, per unit sediment massC12H4Cl6/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.006 ng/g, limit of quantification: 0.01 ng/g
882,2',4,4',5,5'-Hexachlorobiphenyl, per unit sediment massC12H4Cl6/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.002 ng/g, limit of quantification: 0.005 ng/g
892,2',3,4,4',5,5'-Heptachlorobiphenyl, per unit sediment massC12H3Cl7/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.005 ng/g, limit of quantification: 0.01 ng/g
90alpha-Hexachlorocyclohexane, per unit sediment massa-HCH/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.01 ng/g, limit of quantification: 0.02 ng/g
91beta-Hexachlorocyclohexane, per unit sediment massb-HCH/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.005 ng/g, limit of quantification: 0.01 ng/g
92gamma-Hexachlorocyclohexane, per unit sediment massg-HCH/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.004 ng/g, limit of quantification: 0.01 ng/g
93Hexachlorobenzene, per unit sediment massHCB/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.002 ng/g, limit of quantification: 0.006 ng/g
94para,para-Dichlorodiphenyldichloroethane, per unit sediment masspp-DDD/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.007 ng/g, limit of quantification: 0.01 ng/g
95para,para-Dichlorodiphenyldichloroethylene, per unit sediment masspp-DDE/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.002 ng/g, limit of quantification: 0.005 ng/g
96para,para-Dichlorodiphenyltrichloroethane, per unit sediment masspp-DDT/sedng/gLogemann, Anna ElisabethMicrowave extration, column clean-up, SEC, quantification via GC-MS ion-trap system (GC CP3800 coupled to a Saturn 2200, both Varian, CA, USA)measured in sediment, total, limit of detection: 0.008 ng/g, limit of quantification: 0.01 ng/g
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1472 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML