Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Xu, Duo; Song, Baofang; Avila, Marc (2022): Optimal wavenumber as function of Re (A=1,Wo=25) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.949144

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2022-09-28DOI registered: 2023-01-13

RIS CitationBibTeX Citation Share

Abstract:
The data are obtained via an in-house Matlab script (developed by Dr. Baofang Song) to compute the non-modal transient growth of disturbances in pulsatile and oscillatory pipe flows. In this study, a Newtonian fluid driven by pulsatile and oscillatory flow rate flows in a straight pipe. In pulsatile flow, there are three governing parameters: steady Reynolds number (defined by the steady flow component), pulsation amplitude (ratio of oscillatory and steady flow component) and Womersley number (dimensionless pulsation and oscillation frequency). In oscillatory flow, due to vanishment of steady flow component, oscillatory Reynolds number (defined by the oscillation flow component) and Womersley number. The Reynolds number defined by the thickness of Stokes layer is alternatively used for the oscillatory Reynolds number. The study was carried out in a manner that one governing parameter varies while other governing parameters are fixed.
The data file 'wavenumber_Re_Wo25.dat' shows the dependence of the optimal wavenumber on the Reynolds numbers at Womersley number of 25 and pulsation amplitude of 1.
This file includes three columns: the first column indicates the Reynolds number; the second column indicates the optimal axial wavenumber; the third column indicates the optimal azimuthal wavenumber.
Keyword(s):
nonlinear instability; transition to turbulence
Comment:
#(A,Wo)=(1.00,25.00)
#t0:initial time; tf:end time;
VARIABLES = "Re", "axial wavenumber (k)", "azimuthal wavenumber (m)"
ZONE T="data, raw", I=6, J=1
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Reynolds numberReXu, Duo
Axial wave numberk_zXu, Duo
Azimuthal wave numberk_θXu, Duo
Status:
Curation Level: Enhanced curation (CurationLevelC) * Processing Level: PANGAEA data processing level 2 (ProcLevel2)
Size:
18 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Re

k_z

k_θ
5000.001
10000.001
15000.001
20000.001
25000.001
30000.001