Logemann, Anna Elisabeth; Reininghaus, Mathias; Schmidt, Maike M; Ebeling, Anna; Zimmermann, Tristan; Wolschke, Hendrik; Friedrich, Jana; Brockmeyer, Berit; Pröfrock, Daniel; Witt, Gesine (2022): Determination of inorganic and organic pollutants in a dated sediment core of the Skagerrak (North Sea) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.944390

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2022-05-19DOI registered: 2022-06-28

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Abstract:
We investigated 90 contaminants covering inorganic and organic pollutants analyzed in a set of sediment cores taken in the North Sea (Skagerrak). The cores were taken by the German Federal Maritime and Hydrographic Agency (BSH) in August 2017 on the RV CelticExplorer (Cruise CE17013a) using a multi corer (MUC, Oktopus, Kiel, Germany) at 57° 49.8 N and 7° 59.9 E at 520 m water depth. Samples were radiometrically dated and analyzed for the mass fractions of eight elements, as well as Pb isotope ratios by (MC) ICP-MS. Analysis of 61 HOCs was carried out using accelerated solvent extraction followed by GC–MS/MS analysis. Determination of 21 PFAS was carried out following DIN 38414-14, 2011, using LC-MS/MS. Furthermore, concentrations of 12 PAHs and 7 PCBs in porewaters were determined using equilibrium passive sampling and GC-MS analysis. Determined mass fractions decreased towards more recent deposited sediment for most analyzed contaminants. These trends could be linked to the time of introductions of restrictions and bans. Therefore, our results confirm, amongst possible other factors, the effectiveness of environmental legislation by revealing a successive change in contamination levels over the decades.
Related to:
Logemann, Anna Elisabeth; Reininghaus, Mathias; Schmidt, Maike M; Ebeling, Anna; Zimmermann, Tristan; Wolschke, Hendrik; Friedrich, Jana; Brockmeyer, Berit; Pröfrock, Daniel; Witt, Gesine (2022): Assessing the chemical anthropocene – Development of the legacy pollution fingerprint in the North Sea during the last century. Environmental Pollution, 302, 119040, https://doi.org/10.1016/j.envpol.2022.119040
Coverage:
Latitude: 57.829800 * Longitude: 7.997700
Date/Time Start: 2017-08-23T11:26:00 * Date/Time End: 2017-08-23T11:26:00
Minimum DEPTH, sediment/rock: 0.01 m * Maximum DEPTH, sediment/rock: 0.49 m
Event(s):
CE17013_40 * Latitude: 57.829800 * Longitude: 7.997700 * Date/Time: 2017-08-23T11:26:00 * Elevation: -520.0 m * Campaign: CE17013 * Basis: Celtic Explorer * Method/Device: MultiCorer (MUC)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, sediment/rockDepth sedmLogemann, Anna ElisabethGeocode
2AgeAgea AD/CELogemann, Anna Elisabeth
3Age, uncertaintyAge unc±Logemann, Anna Elisabeth
4AGEAgeka BPLogemann, Anna ElisabethGeocode
5ChromiumCrmg/kgLogemann, Anna ElisabethElement analysis grain size fraction <20 microns via ICP-MS (total digest)measured in sediment, total, limit of detection: 2.3 Milligram per kilogram, limit of quantification: 6.2 Milligram per kilogram
6Chromium, uncertaintyCr unc±Logemann, Anna Elisabeth
7NickelNimg/kgLogemann, Anna ElisabethElement analysis grain size fraction <20 microns via ICP-MS (total digest)measured in sediment, total, limit of detection: 0.6 Milligram per kilogram, limit of quantification: 1 Milligram per kilogram
8Nickel, uncertaintyNi unc±Logemann, Anna Elisabeth
9CopperCumg/kgLogemann, Anna ElisabethElement analysis grain size fraction <20 microns via ICP-MS (total digest)measured in sediment, total, limit of detection: 1 Milligram per kilogram, limit of quantification: 3 Milligram per kilogram
10Copper, uncertaintyCu unc±Logemann, Anna Elisabeth
11ZincZnmg/kgLogemann, Anna ElisabethElement analysis grain size fraction <20 microns via ICP-MS (total digest)measured in sediment, total, limit of detection: 18 Milligram per kilogram, limit of quantification: 59 Milligram per kilogram
12Zinc, uncertaintyZn unc±Logemann, Anna Elisabeth
13CadmiumCdmg/kgLogemann, Anna ElisabethElement analysis grain size fraction <20 microns via ICP-MS (total digest)measured in sediment, total, limit of detection: 0.019 Milligram per kilogram, limit of quantification: 0.062 Milligram per kilogram
14Cadmium, uncertaintyCd unc±Logemann, Anna Elisabeth
15LeadPbmg/kgLogemann, Anna ElisabethElement analysis grain size fraction <20 microns via ICP-MS (total digest)measured in sediment, total, limit of detection: 1.6 Milligram per kilogram, limit of quantification: 4.1 Milligram per kilogram
16Lead, uncertaintyPb unc±Logemann, Anna Elisabeth
17ArsenicAsmg/kgLogemann, Anna ElisabethElement analysis grain size fraction <20 microns via ICP-MS (total digest)measured in sediment, total, limit of detection: 0.71 Milligram per kilogram, limit of quantification: 2.4 Milligram per kilogram
18Arsenic, uncertaintyAs unc±Logemann, Anna Elisabeth
19TitaniumTimg/kgLogemann, Anna ElisabethElement analysis grain size fraction <20 microns via ICP-MS (total digest)measured in sediment, total, limit of detection: 80 Milligram per kilogram, limit of quantification: 260 Milligram per kilogram
20Titanium, uncertaintyTi unc±Logemann, Anna Elisabeth
21Lead-206/Lead-204 ratio206Pb/204PbLogemann, Anna ElisabethMulti-collector ICP-MS (MC-ICP-MS), Nu Plasma IImeasured in sediment, total
22Lead-206/Lead-204 ratio, uncertainty206Pb/204Pb unc±Logemann, Anna Elisabeth
23Lead-208/Lead-204 ratio208Pb/204PbLogemann, Anna ElisabethMulti-collector ICP-MS (MC-ICP-MS), Nu Plasma IImeasured in sediment, total
24Lead-208/Lead-204 ratio, uncertainty208Pb/204Pb unc±Logemann, Anna Elisabeth
25Lead-208/Lead-206 ratio208Pb/206PbLogemann, Anna ElisabethMulti-collector ICP-MS (MC-ICP-MS), Nu Plasma IImeasured in sediment, total
26Lead-208/Lead-206 ratio, uncertainty208Pb/206Pb unc±Logemann, Anna Elisabeth
27Lead-207/Lead-206 ratio207Pb/206PbLogemann, Anna ElisabethMulti-collector ICP-MS (MC-ICP-MS), Nu Plasma IImeasured in sediment, total
28Lead-207/Lead-206 ratio, uncertainty207Pb/206Pb unc±Logemann, Anna Elisabeth
29Lead-207/Lead-204 ratio207Pb/204PbLogemann, Anna ElisabethMulti-collector ICP-MS (MC-ICP-MS), Nu Plasma IImeasured in sediment, total
30Lead-207/Lead-204 ratio, uncertainty207Pb/204Pb unc±Logemann, Anna Elisabeth
31Carbon, organic, totalTOC%Logemann, Anna ElisabethCarbon and nitrogen and sulfur (CNS) element analyzer, Elementar, Vario ELmeasured in sediment, total. The TOC analysis was carried out with a VarioEL (Elementar, Germany) in CN mode at 950 degC. The dried and homogenized samples were weighted in silver capsules, acidified with 200 microL of 2 M HCl (32%) and placed in an oven for 3 h at 110 degC to remove the inorganic carbon.
321,2,8-Trimethylphenanthrene, per unit sediment mass1,2,8-Trimethylphenanthrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectorsum, measured in sediment, total, limit of detection: 0.012 Nanogram per gram, limit of quantification: 0.037 Nanogram per gram
331-Methylpyrene, per unit sediment mass1-Methylpyrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectorsum, measured in sediment, total, limit of detection: 0.11 Nanogram per gram, limit of quantification: 0.35 Nanogram per gram
345-Methylchrysene, per unit sediment mass5-Methylchrysene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectorsum, measured in sediment, total, limit of detection: 0.036 Nanogram per gram, limit of quantification: 0.11 Nanogram per gram
35Dimethylated Naphthalenes, per unit sediment massDimethylated Naphthalene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectorsum, measured in sediment, total, limit of detection: 0.017 Nanogram per gram, limit of quantification: 0.043 Nanogram per gram
36Trimethylated Naphthalenes, per unit sediment massTrimethylated Naphthalenes/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectorsum, measured in sediment, total, limit of detection: 0.029 Nanogram per gram, limit of quantification: 0.075 Nanogram per gram
37Methylated Phenantrenes, per unit sediment massMethylated Phenantrenes/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectorsum, measured in sediment, total, limit of detection: 0.029 Nanogram per gram, limit of quantification: 0.074 Nanogram per gram
38Dimethylated Phenantrenes, per unit sediment massDimethylated Phenantrenes/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectorsum, measured in sediment, total, limit of detection: 0.052 Nanogram per gram, limit of quantification: 0.132 Nanogram per gram
39Trimethylated Phenantrenes, per unit sediment massTrimethylated Phenantrenes/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectorsum, measured in sediment, total, limit of detection: 0.012 Nanogram per gram, limit of quantification: 0.03 Nanogram per gram
40Hexachlorobenzene, per unit sediment massHCB/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.01 Nanogram per gram, limit of quantification: 0.03 Nanogram per gram
41alpha-Hexachlorocyclohexane (Lindane), per unit sediment massa-HCH(Lindane)/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.0067 Nanogram per gram, limit of quantification: 0.02 Nanogram per gram
42beta-Hexachlorocyclohexane, per unit sediment massb-HCH/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.014 Nanogram per gram, limit of quantification: 0.041 Nanogram per gram
43gamma-Hexachlorocyclohexane (Lindane), per unit sediment massg-HCH/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.012 Nanogram per gram, limit of quantification: 0.035 Nanogram per gram
44Dieldrin, per unit sediment massDieldrin/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.026 Nanogram per gram, limit of quantification: 0.08 Nanogram per gram
451,1-Dichloro-2,2-bis-(p-chlorophenyl)ethene, per unit sediment mass1,1-Dichloro-2,2-bis-(p-chlorophenyl)ethng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.011 Nanogram per gram, limit of quantification: 0.033 Nanogram per gram
461,1-Dichloro-2,2-bis(p-chlorophenyl)ethane, per unit sediment mass1,1-Dichloro-2,2-bis(p-chlorophenyl)ethang/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.015 Nanogram per gram, limit of quantification: 0.046 Nanogram per gram
471,1,1-Trichloro-2,2-bis-(p-chlorophenyl)-ethane, per unit sediment massDDT/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.0078 Nanogram per gram, limit of quantification: 0.024 Nanogram per gram
482,4,4'-Trichlorobiphenyl/2,4',5-Trichlorobiphenyl, per unit sediment mass2,4,4-Trichlorobiphenyl/2,4,5-Trichlorobng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.016 Nanogram per gram, limit of quantification: 0.05 Nanogram per gram
492,2',5,5'-Tetrachlorobiphenyl, per unit sediment massC12H6Cl4/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.016 Nanogram per gram, limit of quantification: 0.048 Nanogram per gram
502,2',4,5,5'-Pentachlorobiphenyl, per unit sediment massC12H5Cl5/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.012 Nanogram per gram, limit of quantification: 0.038 Nanogram per gram
512,3',4,4',5-Pentachlorobiphenyl, per unit sediment massC12H5Cl/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.011 Nanogram per gram, limit of quantification: 0.034 Nanogram per gram
522,2',4,4',5,5'-Hexachlorobiphenyl, per unit sediment massC12H4Cl6/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.013 Nanogram per gram, limit of quantification: 0.039 Nanogram per gram
532,2',3,4,4',5'-Hexachlorobiphenyl, per unit sediment massC12H4Cl6/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.011 Nanogram per gram, limit of quantification: 0.034 Nanogram per gram
542,2',3,4,4',5,5'-Heptachlorobiphenyl, per unit sediment massC12H3Cl7/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.016 Nanogram per gram, limit of quantification: 0.048 Nanogram per gram
552,4,4'-tribromodiphenyl ether, per unit sediment mass2,4,4-tribromodiphenyl ether/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.0041 Nanogram per gram, limit of quantification: 0.013 Nanogram per gram
562,2',4,4'-tetrabromodiphenyl ether, per unit sediment massBDE47/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.0027 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
572,3',4,4'-tetrabromodiphenyl ether, per unit sediment mass2,3,4,4-tetrabromodiphenyl ether/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.0034 Nanogram per gram, limit of quantification: 0.01 Nanogram per gram
582,2',4,4',6-pentabromodiphenyl ether, per unit sediment massBDE100/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.0059 Nanogram per gram, limit of quantification: 0.018 Nanogram per gram
592,2',4,4',5-pentabromodiphenyl ether, per unit sediment massBDE99/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.0053 Nanogram per gram, limit of quantification: 0.016 Nanogram per gram
602,2',4,4',5,6'-hexabromodiphenyl ether, per unit sediment massBDE154/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.0055 Nanogram per gram, limit of quantification: 0.017 Nanogram per gram
612,2',4,4',5,5'-hexabromodiphenyl ether, per unit sediment mass2,2,4,4,5,5-hexabromodiphenyl ether/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.0059 Nanogram per gram, limit of quantification: 0.018 Nanogram per gram
62Naphthalene, per unit sediment massNaphth/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.13 Nanogram per gram, limit of quantification: 0.41 Nanogram per gram
63Acenaphthylene, per unit sediment massAcenaphthylene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.11 Nanogram per gram, limit of quantification: 0.32 Nanogram per gram
64Acenaphthene, per unit sediment massAcenaphthene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.069 Nanogram per gram, limit of quantification: 0.21 Nanogram per gram
65Fluorene, per unit sediment massFluorene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.077 Nanogram per gram, limit of quantification: 0.23 Nanogram per gram
66Dibenzothiophene, per unit sediment massDBT/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.11 Nanogram per gram, limit of quantification: 0.34 Nanogram per gram
67Phenanthrene, per unit sediment massPhenanthrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.11 Nanogram per gram, limit of quantification: 0.32 Nanogram per gram
68Anthracene, per unit sediment massAnthracene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.11 Nanogram per gram, limit of quantification: 0.34 Nanogram per gram
69Fluoranthene, per unit sediment massFluoranthene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.034 Nanogram per gram, limit of quantification: 0.1 Nanogram per gram
70Pyrene, per unit sediment massPyrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.065 Nanogram per gram, limit of quantification: 0.2 Nanogram per gram
7111H-Benzo(a)fluorene, per unit sediment mass11H-Benzo(a)fluorene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.12 Nanogram per gram, limit of quantification: 0.36 Nanogram per gram
72Cyclopenta(c,d)pyrene, per unit sediment massCyclopenta(c,d)pyrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.036 Nanogram per gram, limit of quantification: 0.11 Nanogram per gram
73Benz(a)anthracene, per unit sediment massBenz(a)anthracene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.11 Nanogram per gram, limit of quantification: 0.34 Nanogram per gram
74Chrysene/Triphenylene, per unit sediment massChrysene/Triphenylene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.39 Nanogram per gram, limit of quantification: 1.2 Nanogram per gram
75Benzo(b)fluoranthene, per unit sediment massBenzo(b)fluoranthene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.11 Nanogram per gram, limit of quantification: 0.32 Nanogram per gram
76Benzo(k)fluoranthene/Benzo(j)fluoranthene, per unit sediment massBenzo(k)fluoranthene/Benzo(j)fluoranthenng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.2 Nanogram per gram, limit of quantification: 0.61 Nanogram per gram
77Benzo(e)pyrene, per unit sediment massBEP/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.11 Nanogram per gram, limit of quantification: 0.34 Nanogram per gram
78Benzo(a)pyrene, per unit sediment massBenzo(a)pyrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.2 Nanogram per gram, limit of quantification: 0.6 Nanogram per gram
79Perylene, per unit sediment massPerylene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.13 Nanogram per gram, limit of quantification: 0.4 Nanogram per gram
80Indeno(1,2,3-cd)pyrene, per unit sediment massIndeno(1,2,3-cd)pyr/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.099 Nanogram per gram, limit of quantification: 0.3 Nanogram per gram
81Dibenz(a,h)anthracene, per unit sediment massDibenz(ah)anthracene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.16 Nanogram per gram, limit of quantification: 0.48 Nanogram per gram
82Benzo(g,h,i)perylene, per unit sediment massBenzo(g,h,i)perylene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.093 Nanogram per gram, limit of quantification: 0.28 Nanogram per gram
83Indeno(1,2,3-cd)pyrene, per unit sediment massIndeno(1,2,3-cd)pyr/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.04 Nanogram per gram, limit of quantification: 0.12 Nanogram per gram
84Dibenzo(a,e)pyrene, per unit sediment massDibenzo(a,e)pyrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.043 Nanogram per gram, limit of quantification: 0.13 Nanogram per gram
85Dibenzo(a,i)pyrene, per unit sediment massDibenzo(a,i)pyrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.039 Nanogram per gram, limit of quantification: 0.12 Nanogram per gram
86Dibenzo(a,h)pyrene, per unit sediment massDibenzo(a,h)pyrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.024 Nanogram per gram, limit of quantification: 0.072 Nanogram per gram
872-Methylnaphthalene, per unit sediment mass2-Methylnaphthalene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.026 Nanogram per gram, limit of quantification: 0.078 Nanogram per gram
881-Methylnaphthalene, per unit sediment mass1-Methylnaphthalene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.12 Nanogram per gram, limit of quantification: 0.38 Nanogram per gram
892,6-Dimethylnaphthalene, per unit sediment mass2,6-Dimethylnaphthalene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.044 Nanogram per gram, limit of quantification: 0.13 Nanogram per gram
902,3,5-Trimethylnaphthalene, per unit sediment mass2,3,5-Trimethylnaphthalene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.098 Nanogram per gram, limit of quantification: 0.3 Nanogram per gram
912-Methylphenanthrene, per unit sediment mass2-Methylphenanthrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.088 Nanogram per gram, limit of quantification: 0.27 Nanogram per gram
923,6-Dimethylphenanthrene, per unit sediment mass3,6-Dimethylphenanthrene/sedng/gLogemann, Anna ElisabethGC–MS/MS system (7890B GC-System, 7000C GC/MS Triple Quad, Agilent Technologies) coupled to an Gerstel MPS robotic pro autosampler with Gerstel KAS 4 injectormeasured in sediment, total, limit of detection: 0.093 Nanogram per gram, limit of quantification: 0.28 Nanogram per gram
93Perfluorodecanoic acid, per unit sediment massPFDA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
94Perfluorooctane sulfonic acid, per unit sediment massPFOS/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
95Perfluorononanoic acid, per unit sediment massPFNA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
96Perfluorooctanoic acid, per unit sediment massPFOA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
97Perfluorohexane sulfonic acid, per unit sediment massPFHxS/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
98Perfluoroheptanoic acid, per unit sediment massPFHpA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
99Perfluorohexanoic acid, per unit sediment massPFHxA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
100Perfluorobutane sulfonic acid, per unit sediment massPFBS/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
101Perfluoropentanoic acid, per unit sediment massPFPeA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
102Perfluorobutanoic acid, per unit sediment massPFBA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
103Perfluoroheptane sulfonic acid, per unit sediment massPFHpS/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
1046:2 fluorotelomer sulfonic acid, per unit sediment mass6:2FTSA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
1054:2 fluorotelomer sulfonic acid, per unit sediment mass4:2FTSA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
1062,3,3,3-tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy)propanoic acid, per unit sediment massHFPO-DA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
1078:2 fluorotelomer sulfonic acid, per unit sediment mass8:2FTSA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
108Perfluoropentane sulfonic acid, per unit sediment massPFGpS/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
109Henicosalfluorodecane sulfonic acid, per unit sediment massPFDS/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
110Perfluoroundecanoic acid, per unit sediment massPFUnDA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
111Perfluorododecanoic acid, per unit sediment massPFDoDA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
112Perfluorotridecanoic acid, per unit sediment massPFTrDA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
113Perfluorotetradecanoic acid, per unit sediment massPFTeDA/sedng/gLogemann, Anna ElisabethLC–MS/MS system (LC: Agilent 1260 pump, Agilent 1200 oven, MS: Sciex QTrap 5500, Agilent Technologies and Sciex)measured in sediment, total, limit of detection: 0.025 Nanogram per gram, limit of quantification: 0.0083 Nanogram per gram
114FluoreneFluorenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
115PhenanthrenePhenanthrenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
116AnthraceneAnthracenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
117FluorantheneFluoranthenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
118PyrenePyrenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
119Benz(a)anthraceneBenz(a)anthracenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
120Chrysene/TriphenyleneChrysene/Triphenylenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
121Benzo(k)fluorantheneBenzo(k)fluoranthenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
122Benzo(a)pyreneBenzo(a)pyrenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
123Indeno(1,2,3-cd)pyreneIndeno(1,2,3-cd)pyrpg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
124Dibenz(a,h)anthraceneDibenz(a,h)anthracenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
125Benzo(g,h,i)peryleneBenzo(g,h,i)perylenepg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
1262,4,4'-Trichlorobiphenyl/2,4',5-Trichlorobiphenyl, per unit sediment mass2,4,4-Trichlorobiphenyl/2,4,5-Trichlorobng/gLogemann, Anna Elisabethmeasured in porewater
1272,2',5,5'-Tetrachlorobiphenyl2,2,5,5-Tetrachlorobiphenylpg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
1282,2',4,5,5'-Pentachlorobiphenyl2,2',4,5,5'-Pentachlorobiphenylpg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
1292,3',4,4',5-Pentachlorobiphenyl2,3',4,4',5-Pentachlorobiphenylpg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
1302,2',4,4',5,5'-Hexachlorobiphenyl2,2,4,4,5,5-Hexachlorobiphenylpg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
1312,2',3,4,4',5'-Hexachlorobiphenyl2,2,3,4,4,5-Hexachlorobiphenylpg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
1322,2',3,4,4',5,5'-Heptachlorobiphenyl2,2,3,4,4,5,5-Heptachlorobiphenylpg/lLogemann, Anna ElisabethGas chromatography/mass spectrometry system (GC 7890B/ MS 5977A, Agilent Technologies)measured in porewater
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
3502 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding: