Campbell, Mae Kate; Bierman, Paul R; Schmidt, Amanda H; Sibello Hernández, Rita Yvelice; Garcia-Moya, Alejandro; Corbett, Lee B; Hidy, Alan J; Cartas Aguila, Héctor Alejandro; Guillén Arruebarrena, Aniel; Balco, Greg; Dethier, David; Caffee, Marc W (2022): Aluminum isotope measurements from the detrital river sediment in central Cuba [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.940045, In: Campbell, MK et al. (2022): In situ Be-10, Al-26, and Ne-21 measurements of detrital river sediment in central Cuba [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.940051
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2022-01-14 • DOI registered: 2022-07-08
Keyword(s):
Related to:
Bierman, Paul R; Sibello Hernández, Rita Yvelice; Schmidt, Amanda H; Cartas Aguila, Héctor Alejandro; Bolaños, Yoelvis; Guillén Arruebarrena, Aniel; Campbell, Mae Kate; Dethier, David; Dix, Monica; Massey-Bierman, Marika; Garcia-Moya, Alejandro; Perdrial, Julia N; Racela, Jason; Alonso-Hernandez, Carlos M (2020): Cuba River Water Chemistry Reveals Rapid Chemical Weathering, the Echo of Uplift, and the Promise of More Sustainable Agriculture. GSA Today, 30(3), 4-10, https://doi.org/10.1130/GSATG419A.1
Coverage:
Median Latitude: 22.246712 * Median Longitude: -80.057946 * South-bound Latitude: 21.832600 * West-bound Longitude: -80.508800 * North-bound Latitude: 22.706800 * East-bound Longitude: -79.017200
Minimum Elevation: 2.0 m * Maximum Elevation: 449.0 m
Event(s):
CU-014 * Latitude: 22.066200 * Longitude: -79.796200 * Elevation: 158.0 m * Location: Cuba * Method/Device: Sampling by hand (HAND) * Comment: Surface sample of river sediment.
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | Event label | Event | Schmidt, Amanda H | Sample ID | ||
| 2 | Laboratory code/label | Lab label | Schmidt, Amanda H | Lab replicate. Sample was splitted into two parts | ||
| 3 | Quartz | Qz | mg | Schmidt, Amanda H | ||
| 4 | Aluminium-27 | 27Al | µg | Schmidt, Amanda H | ||
| 5 | Identification | ID | Schmidt, Amanda H | Accelerator mass spectrometry (AMS) | Cathode Number | |
| 6 | Aluminium-26/Aluminium-27 ratio | 26Al/27Al | Schmidt, Amanda H | Normalized after Nishiizumi et al., 2004 | Uncorrected. Isotopic analysis was conducted at PRIME Laboratory; ratios were normalized against standard KNSTD with an assumed ratio of 1.818 x 10-12 (Nishiizumi et al., 2004). | |
| 7 | Aluminium-26/Aluminium-27 ratio, uncertainty | 26Al/27Al unc | ± | Schmidt, Amanda H | Normalized after Nishiizumi et al., 2004 | Uncorrected. 27Al was added only to samples with insufficient total Al through commercial SPEX ICP standard with a concentration of 1000 μg mL-1. The total here reflects the sum of Al added through carrier and native Al in quartz.. |
| 8 | Aluminium-26/Aluminium-27 ratio | 26Al/27Al | Schmidt, Amanda H | Background-Corrected | ||
| 9 | Aluminium-26/Aluminium-27 ratio, uncertainty | 26Al/27Al unc | ± | Schmidt, Amanda H | Background-Corrected | |
| 10 | Aluminium-26 | 26Al | atoms/g | Schmidt, Amanda H | ||
| 11 | Aluminium-26, uncertainty | 26Al unc | ± | Schmidt, Amanda H |
Change history:
2022-06-08T12:38:23 – Revised version due to adding line for CU-016DUP. Other data for 26Al and the associated uncertainty were updated to reflect an additional blank measurement.
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size: