Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Tagliaro, Gabriel; Brumsack, Hans-Jürgen; Fulthorpe, Craig S (2021): Compositional results from discrete x-ray fluorescence measurements for IODP Hole 369-U1516A (Table S1) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.939185, In: Tagliaro, G et al. (2021): Compositional results from the Late Miocene and Pliocene of Sites U1514 and U1516: X-ray fluorescence and grain-size measurements [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.939189

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2021-12-08DOI registered: 2022-01-06

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Keyword(s):
Grain Size; Late Miocene; marine sediments; Mentelle Basin; Pliocene; U1514; U1516; XRF
Coverage:
Latitude: -34.348615 * Longitude: 112.799255
Date/Time Start: 2017-11-13T17:48:00 * Date/Time End: 2017-11-15T09:25:00
Minimum DEPTH, sediment/rock: 52.96 m * Maximum DEPTH, sediment/rock: 220.40 m
Event(s):
369-U1516A * Latitude: -34.348615 * Longitude: 112.799255 * Date/Time Start: 2017-11-13T17:48:00 * Date/Time End: 2017-11-15T09:25:00 * Elevation: -2676.0 m * Campaign: Exp369 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL)
Comment:
Compositional results (%) from discrete x-ray fluorescence measurements (WD-XRF) for Site U1516. Excess silica is calculated from the linear relationship between terrigenous silica and aluminum content for marine deep-sea sediments (Turekian and Wedepohl, 1961). Terrigenous content is calculated from the difference between carbonate content and excess silica.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmTagliaro, GabrielIODP Depth Scale TerminologyGeocode – m CSF-A
Sample code/labelSample labelTagliaro, GabrielDSDP/ODP/IODP sample designation
Calcium carbonateCaCO3%Tagliaro, GabrielWave-length dispersive X-ray fluorescence spectroscopy (WD-XRF)
Silicon dioxide excessSiO2 xs%Tagliaro, GabrielCalculated
Silicon dioxideSiO2%Tagliaro, GabrielWave-length dispersive X-ray fluorescence spectroscopy (WD-XRF)
Iron oxide, Fe2O3Fe2O3%Tagliaro, GabrielWave-length dispersive X-ray fluorescence spectroscopy (WD-XRF)
Aluminium oxideAl2O3%Tagliaro, GabrielWave-length dispersive X-ray fluorescence spectroscopy (WD-XRF)
Titanium dioxideTiO2%Tagliaro, GabrielWave-length dispersive X-ray fluorescence spectroscopy (WD-XRF)
Lithogenic materialLitho%Tagliaro, GabrielCalculated
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
471 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Sample label

CaCO3 [%]

SiO2 xs [%]

SiO2 [%]

Fe2O3 [%]

Al2O3 [%]

TiO2 [%]

Litho [%]
52.96369-U1516A-7H-1,74-7693.420.822.980.240.640.045.76
61.61369-U1516A-7H-7,39-4192.130.842.420.200.470.037.03
66.21369-U1516A-8H-3,140-15088.175.370.512.070.0913.44
71.96369-U1516A-9H-1,76-7890.720.993.920.300.870.058.29
79.46369-U1516A-9H-6,74-7690.862.855.710.370.850.066.29
81.46369-U1516A-10H-1,74-7694.310.743.400.290.790.044.95
89.76369-U1516A-10H-7,4-685.132.898.010.591.520.0911.98
90.96369-U1516A-11H-1,74-7696.810.652.710.250.610.032.54
93.96369-U1516A-11H-3,74-7693.380.742.900.230.640.045.88
99.61369-U1516A-11H-7,39-4192.490.973.600.280.780.056.54
100.26369-U1516A-12H-1,54-5682.143.156.490.340.990.0614.71
105.70369-U1516A-12H-4,140-15093.490.823.010.300.650.045.69
109.11369-U1516A-12H-7,39-4195.170.652.710.210.610.044.18
110.01369-U1516A-13H-1,79-8194.080.943.060.230.630.044.99
114.46369-U1516A-13H-4,74-7692.420.983.740.270.820.056.61
115.20369-U1516A-13H-4,140-15092.310.853.550.260.800.056.84
118.61369-U1516A-13H-7,39-4190.760.604.000.371.010.068.65
119.68369-U1516A-14H-1,96-9851.1729.5638.621.752.690.2819.27
122.46369-U1516A-14H-3,74-7693.361.284.110.320.840.055.36
124.70369-U1516A-14H-4,140-15087.011.267.220.711.770.1011.74
128.11369-U1516A-14H-7,39-4192.060.563.590.350.900.057.38
128.71369-U1516A-15H-1,49-5191.510.472.660.250.650.048.02
131.96369-U1516A-15H-3,74-7689.740.685.160.441.330.079.58
134.20369-U1516A-15H-4,140-15092.600.733.120.240.710.046.68
137.61369-U1516A-15H-7,39-4189.080.603.600.270.890.0510.32
139.96369-U1516A-16H-2,74-7691.770.414.220.431.130.067.81
141.61369-U1516A-16H-3,89-9184.582.529.090.861.950.1012.90
143.70369-U1516A-16H-4,140-15088.311.205.480.381.270.0710.49
147.13369-U1516A-16H-7,41-4393.330.683.340.320.790.045.99
147.96369-U1516A-17H-1,74-7692.720.623.280.390.790.056.66
151.01369-U1516A-17H-3,79-8186.352.547.290.551.410.0811.11
153.20369-U1516A-17H-4,140-15094.240.793.050.230.670.044.97
156.61369-U1516A-17H-7,39-4193.010.543.940.351.010.066.46
157.41369-U1516A-18H-1,69-7193.741.164.130.360.880.065.10
161.96369-U1516A-18H-4,74-7692.290.754.390.401.080.066.96
162.70369-U1516A-18H-4,140-15090.170.523.890.331.000.069.31
166.21369-U1516A-18H-7,49-5161.0224.0330.871.492.030.4014.95
166.31369-U1516A-19H-1,9-1192.401.324.660.400.990.066.28
172.20369-U1516A-19H-4,140-15091.060.493.990.411.040.068.45
175.62369-U1516A-19H-7,39-4193.590.513.480.310.880.055.89
176.46369-U1516A-20H-1,74-7693.080.773.400.290.780.056.15
178.71369-U1516A-20H-2,140-15091.470.733.220.300.740.047.80
180.92369-U1516A-20H-5,19-2164.2926.6428.970.440.690.069.07
182.06369-U1516A-21F-1,74-7691.920.833.660.330.840.057.25
184.32369-U1516A-21F-2,142-15291.901.264.020.390.820.056.84
186.76369-U1516A-22F-1,74-7691.111.454.180.340.810.057.44
189.71369-U1516A-22F-3,70-7288.922.665.730.570.910.068.42
190.43369-U1516A-22F-4,39-4190.402.196.370.451.240.077.41
191.02369-U1516A-22F-CC,19-2490.082.274.970.350.800.057.65
191.46369-U1516A-23F-1,74-7689.281.935.470.411.050.068.79
192.22369-U1516A-23F-1,142-15290.103.025.850.350.840.066.88
194.43369-U1516A-23F-3,69-7165.2226.3329.300.540.880.108.45
195.07369-U1516A-23F-4,31-3361.5028.8931.920.600.900.109.61
199.11369-U1516A-24F-3,70-7290.152.095.260.340.940.067.76
203.10369-U1516A-25F-2,140-15089.632.615.470.290.850.057.76
208.51369-U1516A-26F-3,71-7390.722.745.370.290.780.056.54
212.50369-U1516A-27F-2,140-15092.852.074.400.270.690.055.08
217.91369-U1516A-28F-3,70-7292.331.984.000.280.600.045.69
220.40369-U1516A-29F-1,141-15193.102.193.940.260.520.044.72