Staniszewska, Kasia; Reyes, Alberto; Cooke, Colin; Miller, Brooklyn; Woywitka, Robin (2021): Old Crow River - Hydrochemistry data for thaw slump upstream, downstream, and rill samples, July 2019 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.935073, In: Staniszewska, K et al. (2021): Old Crow River, Tributary, and Thaw Slump Sampling 2019, Yukon, Canada [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.935074

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
Hydrochemistry data for thaw slump upstream, downstream, and rill samples, collected between July 21 - 27, 2019.
Keyword(s):
major ion; mercury; Old Crow; Old Crow River; river; sediment; thaw slump; trace element; tributary; Vantat; Vuntut; water quality
Coverage:
Median Latitude: 67.923250 * Median Longitude: -139.798450 * South-bound Latitude: 67.808700 * West-bound Longitude: -139.886400 * North-bound Latitude: 68.100800 * East-bound Longitude: -139.710600
Date/Time Start: 2019-07-23T01:00:00 * Date/Time End: 2019-07-25T18:00:00
Event(s):
OCRT19_ThawSlump1 * Latitude: 68.100800 * Longitude: -139.835100 * Date/Time Start: 2019-07-23T01:00:00 * Date/Time End: 2019-07-23T02:00:00 * Method/Device: Water sample (WS)
OCRT19_ThawSlump2 * Latitude: 67.808700 * Longitude: -139.886400 * Date/Time Start: 2019-07-24T18:30:00 * Date/Time End: 2019-07-24T19:30:00 * Method/Device: Water sample (WS)
OCRT19_ThawSlump3 * Latitude: 67.879800 * Longitude: -139.761700 * Date/Time Start: 2019-07-25T01:00:00 * Date/Time End: 2019-07-25T01:00:00 * Method/Device: Water sample (WS)
Comment:
Total and dissolved mercury were measured using oxidation, purge and trap, and Cold Vapor Atomic Fluorescence Spectrometry on a Tekran 2600 Total Mercury Analyzer.
Methylmercury and dissolved methylmercury were measured by isotope dilution, distillation, aqueous ethylation, purge and trap, gas chromatography and inductively coupled plasma mass spectrometry using a Tekran 2750 Methyl Mercury Distillation System, Tekran 2700 Methyl Mercury Analyzer, and Agilent 7900 ICP-MS.
Filterable and nonfilterable residue concentrations (i.e., total dissolved and total suspended solids; TDS and TSS) were derived from masses of, respectively, evaporated, and dried materials of known original volumes.
MDL: method detection limit
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventStaniszewska, Kasia
2DATE/TIMEDate/TimeStaniszewska, KasiaGeocode – UTC
3LATITUDELatitudeStaniszewska, KasiaGeocode
4LONGITUDELongitudeStaniszewska, KasiaGeocode
5Sample IDSample IDStaniszewska, Kasia
6IdentificationIDStaniszewska, KasiaThaw Slump Number
7Sample typeSamp typeStaniszewska, Kasia
8Mercury, totalHg totng/lStaniszewska, KasiaSee description in dataset commentMDL < 0.06 ng/l
9Mercury, dissolvedHg dissng/lStaniszewska, KasiaSee description in dataset commentMDL < 0.08 ng/l
10Methylmercury, totalMeHg totng/lStaniszewska, KasiaSee description in dataset commentMDL < 0.01 ng/l
11Methylmercury, dissolvedMeHg dissng/lStaniszewska, KasiaSee description in dataset commentMDL < 0.01 ng/l
12Nitrogen in nitrite + nitrateN-[NO2]- + [NO3]-µg/lStaniszewska, KasiaMDL < 2 µg/l
13Nitrogen in nitriteN-[NO2]-µg/lStaniszewska, KasiaFlow injection analysisMDL < 1 µg/l; analyzed on a Lachat QuickChem QC8500 FIA Automated Ion Analyzer
14Nitrogen in ammoniumN-[NH4]+µg/lStaniszewska, KasiaFlow injection analysisMDL < 3 µg/l; analyzed on a Lachat QuickChem QC8500 FIA Automated Ion Analyzer
15Nitrogen, totalTNµg/lStaniszewska, KasiaFlow injection analysisMDL < 6 µg/l; analyzed on a Lachat QuickChem QC8500 FIA Automated Ion Analyzer
16Nitrogen, total dissolvedTDNµg/lStaniszewska, KasiaFlow injection analysisMDL < 6 µg/l; analyzed on a Lachat QuickChem QC8500 FIA Automated Ion Analyzer
17Nitrogen, total KjeldahlTKNµg/lStaniszewska, KasiaFlow injection analysisMDL < 6 µg/l; analyzed on a Lachat QuickChem QC8500 FIA Automated Ion Analyzer
18Phosphorus, reactive solubleSRPµg/lStaniszewska, KasiaFlow injection analysisMDL < 1 µg/L; analyzed on a Lachat QuickChem QC8500 FIA Automated Ion Analyzer
19Phosphorus, totalTPµg/lStaniszewska, KasiaFlow injection analysisMDL < 1 µg/l; analyzed on a Lachat QuickChem QC8500 FIA Automated Ion Analyzer
20Phosphorus, dissolvedTDPµg/lStaniszewska, KasiaFlow injection analysisMDL < 2 µg/l; analyzed on a Lachat QuickChem QC8500 FIA Automated Ion Analyzer
21AluminiumAlµg/lStaniszewska, KasiaICAP-AES, Inductively coupled argon plasma - atomic emission spectroscopyMDL < 3.6 µg/l; cations
22CalciumCamg/lStaniszewska, KasiaICAP-AES, Inductively coupled argon plasma - atomic emission spectroscopyMDL < 0.01 mg/l; cations
23PotassiumKmg/lStaniszewska, KasiaICAP-AES, Inductively coupled argon plasma - atomic emission spectroscopyMDL < 0.01 mg/l; cations
24MagnesiumMgmg/lStaniszewska, KasiaICAP-AES, Inductively coupled argon plasma - atomic emission spectroscopyMDL < 0.01 mg/l; cations
25SodiumNamg/lStaniszewska, KasiaICAP-AES, Inductively coupled argon plasma - atomic emission spectroscopyMDL < 0.02 mg/l; cations
26ChlorideCl-mg/lStaniszewska, KasiaIon chromatographyMDL < 0.03 mg/l; anions
27Sulfate[SO4]2-mg/lStaniszewska, KasiaIon chromatographyMDL < 0.04 mg/l; anions
28Carbon, organic, dissolvedDOCmg/lStaniszewska, KasiaShimadzu Total Organic Carbon Analyzer (TOC-5000A)MDL < 0.1 mg/l; measured by Shimadzu analysis
29Carbon, inorganic, dissolvedDICmg/lStaniszewska, KasiaMDL < 0.2 mg/l; measured by Shimadzu analysis
30pHpHStaniszewska, KasiaTitrationusing electrometric PC-Titrate instrumentation
31Alkalinity, totalATmg/lStaniszewska, KasiaTitrationMDL < 3 mg/l; using electrometric PC-Titrate instrumentation
32Conductivity, electricalCond electrµS/cmStaniszewska, KasiaTitrationusing electrometric PC-Titrate instrumentation
33Turbidity (Nephelometric turbidity unit)TurbidityNTUStaniszewska, KasiaLaboratory Turbidity meter, Hach, 2100NMDL unknown
34Total dissolved solidsTDSmg/lStaniszewska, KasiaSee description in dataset commentMDL < 0.05 mg/l
35Suspended solids, totalTSSmg/lStaniszewska, KasiaSee description in dataset commentMDL < 0.05 mg/l
36δ Deuterium, waterδD H2O‰ SMOWStaniszewska, KasiaCavity ring-down spectroscopy (CRDS), L2130-i, Picarro Inc.relative to Vienna Standard Mean Ocean Water (VSMOW)
37δ18O, waterδ18O H2O‰ SMOWStaniszewska, KasiaCavity ring-down spectroscopy (CRDS), L2130-i, Picarro Inc.relative to Vienna Standard Mean Ocean Water (VSMOW)
38Aluminium, totalAl totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 4 µg/l
39Antimony, totalSb totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.008 µg/l
40Arsenic, totalAs totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.01 µg/l
41Barium, totalBa totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.05 µg/l
42Beryllium, totalBe totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.003 µg/l
43Bismuth, totalBi totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.003 µg/l
44Boron, totalB totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.2 µg/l
45Cadmium, totalCd totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.01 µg/l
46Calcium, totalCa totmg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.01 mg/l
47Chlorine, totalCl totmg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.03 mg/l
48Chromium, totalCr totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.1 µg/l
49Cobalt, totalCo totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.002 µg/l
50Copper, totalCu totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.08 µg/l
51Iron, totalFe totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 6 µg/l
52Lead, totalPb totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.004 µg/l
53Lithium, totalLi totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.007 µg/l
54Manganese, totalMn totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.04 µg/l
55Molybdenum, totalMo totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.002 µg/l
56Nickel, totalNi totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.03 µg/l
57Selenium, totalSe totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.2 µg/l
58Silver, totalAg totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.001 µg/l
59Strontium, totalSr totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.07 µg/l
60Thallium, totalTl totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.002 µg/l
61Thorium, totalTh totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.002 µg/l
62Tin, totalSn totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.06 µg/l
63Titanium, totalTi totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.03 µg/l
64Uranium, totalU totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.002 µg/l
65Vanadium, totalV totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.007 µg/l
66Zinc, totalZn totµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.2 µg/l
67Aluminium, dissolvedAl dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.4 µg/l
68Antimony, dissolvedSb dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.09 µg/l
69Arsenic, dissolvedAs dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.01 µg/l
70Barium, dissolvedBa dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.05 µg/l
71Beryllium, dissolvedBe dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.004 µg/l
72Bismuth, dissolvedBi dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.003 µg/l
73Boron, dissolvedB dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.2 µg/l
74Cadmium, dissolvedCd dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.002 µg/l
75Calcium, dissolvedCa dissmg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.03 mg/l
76Chlorine, dissolvedCl dissmg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.2 mg/l
77Chromium, dissolvedCr dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.3 µg/l
78Cobalt, dissolvedCo dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.006 µg/l
79Copper, dissolvedCu dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.08 µg/l
80Iron, dissolvedFe dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 2 µg/l
81Lead, dissolvedPb dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.02 µg/l
82Lithium, dissolvedLi dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.02 µg/l
83Manganese, dissolvedMn dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.01 µg/l
84Molybdenum, dissolvedMo dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.005 µg/l
85Nickel, dissolvedNi dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.03 µg/l
86Selenium, dissolvedSe dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.2 µg/l
87Silver, dissolvedAg dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.003 µg/l
88Strontium, dissolvedSr dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.07 µg/l
89Thallium, dissolvedTl dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.002 µg/l
90Thorium, dissolvedTh dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.002 µg/l
91Tin, dissolvedSn dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.06 µg/l
92Titanium, dissolvedTi dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.03 µg/l
93Uranium, dissolvedU dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.002 µg/l
94Vanadium, dissolvedV dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.006 µg/l
95Zinc, dissolvedZn dissµg/lStaniszewska, KasiaInductively coupled plasma mass spectrometry (ICP-MS)MDL < 0.3 µg/l
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1092 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML