Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Klotz, Franziska; Pester, Michael (2021): Ammonium and nitrate concentrations in Lake Constance, Germany [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.934378, In: Klotz, F; Pester, M (2021): Archaeal nitrification in Lake Constance, Germany [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.934577

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
This dataset is part of a study investigating the freshwater Nitrososphaeria and their impact on the nitrogen cycling in lakes. It includes monthly measurements of nitrate and ammonia concentrations in the whole water column (1-135 m) in Lake Constance (Germany) from November 2017 to November 2019. Water was taken with a Niskin bottle and pre-filtered on board directly through 0.2µm. The indicated time represents the sampling time.
Keyword(s):
freshwater lake; hypolimnion; nitrification rate; Thaumarchaeota
Related to:
Holmes, Robert M; Aminot, A; Kerouel, Roger; Hooker, Bethanie A; Peterson, Bruce J (1999): A simple and precise method for measuring ammonium in marine and freshwater ecosystems. Canadian Journal of Fisheries and Aquatic Sciences, 56(10), 1801-1808, https://doi.org/10.1139/f99-128
Klotz, Franziska; Kitzinger, Katharina; Ngugi, David Kamanda; Büsing, Petra; Littmann, Sten; Kuypers, Marcel MM; Schink, Bernhard; Pester, Michael (2021): Quantification of archaea-driven freshwater nitrification: from single cell to ecosystem level. bioRxiv, https://doi.org/10.1101/2021.07.22.453385
Coverage:
Latitude: 47.757880 * Longitude: 9.126170
Date/Time Start: 2017-11-21T11:00:00 * Date/Time End: 2019-11-04T12:22:00
Minimum DEPTH, water: m * Maximum DEPTH, water: 135 m
Event(s):
Lake-Constance_Nitrification_2017-2019 * Latitude: 47.757880 * Longitude: 9.126170 * Date/Time Start: 2017-11-08T00:00:00 * Date/Time End: 2019-11-19T00:00:00 * Elevation: -140.0 m * Location: Lake Constance * Method/Device: Multiple investigations (MULT)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DATE/TIMEDate/TimeKlotz, FranziskaGeocode
DEPTH, waterDepth watermKlotz, FranziskaGeocode
Ammonium[NH4]+µmol/lKlotz, Franziskasee Method comment
Nitrate[NO3]-µmol/lKlotz, Franziskasee Method comment
LocationLocationKlotz, Franziska
LATITUDELatitudeKlotz, FranziskaGeocode
LONGITUDELongitudeKlotz, FranziskaGeocode
Method commentMethod commKlotz, FranziskaAmmonium concentration
Method commentMethod commKlotz, FranziskaNitrate concentration
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1228 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Date/Time

Depth water [m]

[NH4]+ [µmol/l]

[NO3]- [µmol/l]

Location

Latitude

Longitude

Method comm
(Ammonium concentration)

Method comm
(Nitrate concentration)
2017-11-21T11:0010.120030.95Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:0550.170030.34Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:10100.170031.88Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:15150.150032.13Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:20200.160031.41Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:25300.060041.41Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:30400.170041.62Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:35500.110039.95Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:40600.100041.66Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:45850.100025.77Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:501100.130028.24Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-11-21T11:551350.250031.20Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T11:5610.360030.27Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:0150.370033.23Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:06100.110030.99Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:11150.120030.06Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:16200.120031.59Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:21300.200032.63Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:26400.180032.66Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:31500.140033.41Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:36600.120032.73Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:41850.120034.34Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:461100.050033.84Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2017-12-19T12:511350.100033.77Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T11:5910.110033.84Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:0450.110031.52Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:09100.090033.81Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:14150.040035.30Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:19200.140035.45Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:24300.100035.84Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:29400.050036.30Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:34500.040037.13Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:39600.060036.73Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:44850.040037.80Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:491100.040038.52Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-01-09T12:541350.060037.34Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T12:5010.140037.00Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T12:5550.110033.36Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:00100.080033.13Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:05150.060032.59Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:10200.060031.74Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:15300.020031.81Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:20400.040037.67Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:25500.020038.14Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:30600.030037.63Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:35850.060034.27Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:401100.040037.46Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-02-06T13:451350.020038.64Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:0510.040034.63Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:1050.060034.59Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:15100.040034.66Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:20150.050034.07Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:25200.050034.79Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:30300.090034.59Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:35400.060034.53Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:40500.050033.07Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:45600.120037.31Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:50850.080036.86Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T11:551100.070037.26Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-03-13T12:001350.090035.24Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T10:4610.120033.79Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T10:5150.140033.91Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T10:56100.200034.89Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T11:01150.190034.44Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T11:06200.170034.94Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T11:11300.140034.69Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T11:16400.170029.76Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T11:21500.050038.14Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T11:26600.060034.98Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T11:31850.070034.53Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T11:361100.060036.62Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-04-24T11:411350.060034.03Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T10:5310.120032.20Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T10:5850.100031.86Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:03100.200031.90Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:08150.310031.60Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:13200.410034.82Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:18300.310036.90Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:23400.170034.71Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:28500.130033.25Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:33600.080031.26Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:38850.040032.68Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:431100.030033.25Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-05-22T11:481350.040031.78Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T10:5210.210046.01Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T10:5750.300044.27Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:02100.240045.78Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:07150.460064.26Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:12200.260075.49Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:17300.100075.04Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:22400.050071.02Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:27500.030071.20Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:32600.040071.45Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:37850.060073.09Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:421100.040073.81Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-06-19T11:471350.050072.91Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T11:4010.120029.36Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T11:4550.100027.22Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T11:50100.090038.82Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T11:55150.170055.15Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T12:00200.080059.29Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T12:05300.090056.05Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T12:10400.060065.98Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T12:15500.060064.79Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T12:20600.040064.03Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T12:25850.040064.49Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T12:301100.020066.73Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-07-17T12:351350.060061.52Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:0610.300021.65Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:1150.290022.33Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:16100.250036.08Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:21150.150045.53Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:26200.060050.73Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:31300.060050.28Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:36400.040050.63Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:41500.030049.90Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:46600.020050.38Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:51850.010049.93Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T11:561100.020050.51Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-08-14T12:011350.090051.31Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T12:2010.250018.86Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T12:2550.230018.25Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T12:30100.340021.87Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T12:35150.360040.45Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T12:40200.110043.54Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T12:45300.030043.55Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T12:50400.030043.17Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T12:55500.070042.34Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T13:00600.060041.55Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T13:05850.060040.65Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T13:101100.260036.29Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-09-11T13:151350.040040.40Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T10:5510.350022.11Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:0050.360023.38Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:05100.390024.09Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:10150.380023.04Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:15200.110037.80Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:20300.040042.50Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:25400.040042.82Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:30500.100041.45Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:35600.040043.09Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:40850.020042.32Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:451100.020043.51Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-10-23T11:501350.080044.41Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T12:4610.140050.48Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T12:5150.180049.55Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T12:56100.160050.66Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T13:01150.200050.76Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T13:06200.170051.90Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T13:11300.200049.58Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T13:16400.220050.05Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T13:21500.160053.12Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T13:26600.200052.98Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T13:31850.140058.19Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T13:361100.110056.97Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2018-12-18T13:411350.120054.05Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:0110.100054.40Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:0650.100054.19Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:11100.090055.87Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:16150.050053.44Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:21200.050053.76Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:26300.040055.26Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:31400.040053.01Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:36500.030055.19Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:41600.020054.76Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:46850.040053.94Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:511100.020054.94Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-01-11T13:561350.040054.97Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T10:4510.120050.51Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T10:5050.100052.58Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T10:55100.050052.12Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:00150.050053.44Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:05200.050053.40Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:10250.060052.90Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:15300.110052.58Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:20400.100046.98Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:25500.060052.90Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:30600.100051.80Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:35850.140051.12Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:401100.100050.41Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-02-12T11:451350.090050.91Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T12:2210.170045.27Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T12:2750.130044.44Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T12:32100.120044.94Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T12:37150.120044.41Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T12:42200.180044.16Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T12:47250.250048.26Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T12:52300.110046.01Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T12:57400.350051.01Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T13:02500.190048.58Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T13:07600.170048.30Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T13:12850.080049.55Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T13:171100.100049.05Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-04-25T13:221350.090050.12Lake Constance, Germany47.757889.12617Seal analytics methods G-171-96 Rev. 14Seal analytics methods G-172-96 Rev. 12
2019-07-02T09:0710.610645.55Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:1250.313148.99Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:17100.128147.90Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:22150.081560.55Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:27200.095264.94Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:32250.489867.52Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:37300.184168.40Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:42400.048765.74Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:47500.026061.50Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:52600.023267.50Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T09:57850.039167.40Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T10:021100.032177.77Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-07-02T10:071350.044274.43Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:1410.074219.54Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:1950.096644.87Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:24100.016536.06Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:291553.30Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:34200.238267.33Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:39250.262656.66Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:44300.112168.70Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:49400.166168.63Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:54500.171659.13Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T09:596069.27Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T10:04850.046979.85Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T10:091100.191378.21Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-08-28T10:141350.033770.14Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:0510.115652.10Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:1050.080944.39Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:15100.250740.45Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:20150.214555.80Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:25200.048562.49Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:30250.218553.49Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:35300.050779.88Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:40400.154959.34Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:45500.190254.97Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:50600.058263.97Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T11:55850.122263.40Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T12:001100.089668.64Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-09-24T12:051350.101564.53Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T11:2210.500748.24Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T11:2750.586353.47Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T11:32100.544547.67Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T11:37150.543152.89Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T11:42200.124952.54Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T11:47250.088257.91Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T11:52300.079751.89Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T11:57400.097056.33Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T12:02500.060960.81Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T12:07600.075069.66Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T12:12850.069153.21Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T12:171100.069058.60Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)
2019-11-04T12:221350.134355.17Lake Constance, Germany47.757889.12617ortho-phthaldialdehyde method after Holmes et al. (1999; doi:10.1139/f99-128)ion chromatography (S150 Chromatography System, SYKAM)