Ewald, Jessica M; Awad, Andrew M; Martinez, Andres; Hornbuckle, Keri C; Schnoor, Jerald L; Mattes, Timothy E (2021): Concentration of individual polychlorinated biphenyl congeners in surficial freshwater sediments from a contaminated wastewater lagoon [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.933459
Always quote citation above when using data! You can download the citation in several formats below.
Abstract:
We report the results of individual polychlorinated biphenyl (PCB) congeners in the surficial freshwater sediment from a wastewater lagoon located in Virginia (USA). PCB congeners were measured using tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM), a method that provides a high-level selectivity and sensitivity for PCBs in complex environmental samples. The PCB concentrations (sum of 171 congeners or coeluting peaks) range from 6,340 to 12,700,000 ng/g dry weight (d.w.). PCB congener profile of samples resembles commercial mixture Aroclor 1248, with the exception of one sample.
Related to:
Mattes, Timothy E; Ewald, Jessica M; Liang, Yi; Martinez, Andres; Awad, Andrew M; Richards, Patrick; Hornbuckle, Keri C; Schnoor, Jerald L (2018): PCB dechlorination hotspots and reductive dehalogenase genes in sediments from a contaminated wastewater lagoon. Environmental Science and Pollution Research, 25(17), 16376-16388, https://doi.org/10.1007/s11356-017-9872-x
Funding:
National Institute of Environmental Health Sciences (NIEHS), grant/award no. 3P42ES013661-14S1: Superfund Research Program
Coverage:
Median Latitude: 37.113850 * Median Longitude: -79.272789 * South-bound Latitude: 37.113076 * West-bound Longitude: -79.273733 * North-bound Latitude: 37.114489 * East-bound Longitude: -79.271934
Date/Time Start: 2015-09-15T00:00:00 * Date/Time End: 2015-09-15T00:00:00
Minimum Elevation: 167.0 m * Maximum Elevation: 167.0 m
Event(s):
Comment:
Individual PCB congener in surficial sediment using GC-MS/MS * Values = 0 indicates non-detected or below the limit of quantification.
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Sample code/label | Sample label | Mattes, Timothy E | |||
2 | Method comment | Method comm | Mattes, Timothy E | |||
3 | LATITUDE | Latitude | Mattes, Timothy E | Geocode | ||
4 | LONGITUDE | Longitude | Mattes, Timothy E | Geocode | ||
5 | Date | Date | Mattes, Timothy E | |||
6 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB1 |
7 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB2 |
8 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB3 |
9 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB4 |
10 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB5 |
11 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB6 |
12 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB7 |
13 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB8 |
14 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB9 |
15 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB10 |
16 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB11 |
17 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB12+13 |
18 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB15 |
19 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB16 |
20 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB17 |
21 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB18+30 |
22 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB19 |
23 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB20+28 |
24 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB21+33 |
25 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB22 |
26 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB23 |
27 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB24 |
28 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB25 |
29 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB26+29 |
30 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB27 |
31 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB31 |
32 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB32 |
33 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB34 |
34 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB35 |
35 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB36 |
36 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB37 |
37 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB38 |
38 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB39 |
39 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB40+71 |
40 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB41 |
41 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB42 |
42 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB43 |
43 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB44+47+65 |
44 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB45 |
45 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB46 |
46 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB48 |
47 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB49+69 |
48 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB50+53 |
49 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB51 |
50 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB52 |
51 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB54 |
52 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB55 |
53 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB56 |
54 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB57 |
55 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB58 |
56 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB59+62+75 |
57 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB60 |
58 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB61+70+74+76 |
59 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB63 |
60 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB64 |
61 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB66 |
62 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB67 |
63 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB68 |
64 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB72 |
65 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB73 |
66 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB77 |
67 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB78 |
68 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB79 |
69 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB80 |
70 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB81 |
71 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB82 |
72 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB83 |
73 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB84 |
74 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB85+116 |
75 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB86+97+109+119 |
76 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB88 |
77 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB89 |
78 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB90+101+113 |
79 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB91 |
80 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB92 |
81 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB93+100 |
82 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB94 |
83 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB95 |
84 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB96 |
85 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB87+125 |
86 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB98 |
87 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB99 |
88 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB102 |
89 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB103 |
90 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB104 |
91 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB105 |
92 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB106 |
93 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB108 |
94 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB107+124 |
95 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB110 |
96 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB111 |
97 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB112 |
98 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB114 |
99 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB115 |
100 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB117 |
101 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB118 |
102 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB120 |
103 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB121 |
104 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB122 |
105 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB123 |
106 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB126 |
107 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB127 |
108 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB129+138+163 |
109 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB130 |
110 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB131 |
111 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB132 |
112 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB133 |
113 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB134 |
114 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB135+151 |
115 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB136 |
116 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB137 |
117 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB139+140 |
118 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB141 |
119 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB143 |
120 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB142 |
121 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB144 |
122 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB145 |
123 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB146 |
124 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB147+149 |
125 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB148 |
126 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB150 |
127 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB152 |
128 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB153+168 |
129 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB154 |
130 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB155 |
131 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB156+157 |
132 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB158 |
133 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB159 |
134 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB160 |
135 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB161 |
136 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB162 |
137 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB164 |
138 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB165 |
139 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB167 |
140 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB169 |
141 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB170 |
142 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB171+173 |
143 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB172 |
144 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB174 |
145 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB175 |
146 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB176 |
147 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB177 |
148 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB178 |
149 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB179 |
150 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB180+193 |
151 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB181 |
152 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB182 |
153 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB183 |
154 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB184 |
155 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB185 |
156 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB186 |
157 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB187 |
158 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB188 |
159 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB189 |
160 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB190 |
161 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB191 |
162 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB192 |
163 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB194 |
164 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB195 |
165 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB196 |
166 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB197 |
167 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB198+199 |
168 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB200 |
169 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB201 |
170 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB202 |
171 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB203 |
172 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB205 |
173 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB206 |
174 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB207 |
175 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB208 |
176 | Polychlorinated biphenyl, per unit sediment dry mass | PCB/sed dm | ng/g | Mattes, Timothy E | tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM) | PCB209 |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
4698 data points
Download Data
View dataset as HTML (shows only first 2000 rows)