Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Krisch, Stephan; Roig, Stéphane; Lodeiro, Pablo Fernandez; Yong, Jaw-Chuen; Herzberg, Nicola; Evers, Florian; Achterberg, Eric Pieter; Steffens, Tim (2021): Dissolved trace elements (Fe, Mn, Co, Ni, Cu, Zn, Cd and Pb) measured on water bottle samples from ultra clean CTD/Water sampler-system during POLARSTERN cruise PS100 / GN05 (ARK-XXX/2) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.933431

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
This dataset contains measured dissolved trace element concentrations (Fe, Mn, Co, Ni, Cu, Zn, Cd and Pb) of station depth profiles sampled in Fram Strait (North Greenland Sea) during GEOTRACES expedition GN05 (PS100) between 21 July and 1 September 2016. Samples were collected strictly following GEOTRACES guidelines (Cutter et al., 2017; https://www.geotraces.org) and analysed exactly as per Rapp et al., 2017 ( Anal. Chim. Acta; doi:10.1016/j.aca.2017.05.008). Concentrations were intercalibrated with GEOTRACES reference materials SAFe S and GSC (Bruland Research Lab), with exception of dissolved Cd data. Information on the analytical procedure including reference materials and limits of detection can be found in related published manuscripts, the PhD thesis of Stephan Krisch (Christian-Albrechts-Universität zu Kiel) or can be obtained from the authors upon request. Table caption: Measured concentrations of dissolved trace elements in Fram Strait sampled during GEOTRACES expedition GN05 (PS100) between 21 July-1 September 2006. Uncertainty is calculated as one standard deviation (1σ, STD) to replicate measurements via ICP-MS. ND = no data. Use of quality flags (QF) according to GEOTRACES policy (https://www.geotraces.org/geotraces-quality-flag-policy/). Plesae note, dissolved Cd data is not quality controlled. Somes samples were pooled (indicated in column "Bottle") from different bottles at one depth; the concentrations reflects the mean and the corresponding uncertainty is calculated as the standard deviation to replicate measurements. Trace metal concentrations at station 24 may show larger variations between different bottles at one specific depth. Because station 24 is located at Dijmphna Sund entrance sill, we associate these discrepancies to the water column's strong lateral and vertical turbulence (see ucCTD physical oceanography data) (e.g. Mortensen et al. 2011, 2013, Carroll et al. 2017) that goes in hand with localized TM aggregation-dissolution and sediment resuspension processes, thus affecting TM fractionation (e.g. Homoky et al. 2012).
Keyword(s):
Arctic; Fram Strait; GN05; Greenland Sea; micronutrients; Polarstern; PS100; trace elements; trace metals
Related to:
Krause, Jana; Hopwood, Mark James; Höfer, Juan; Krisch, Stephan; Achterberg, Eric Pieter; Alarcon, Emilio; Carroll, Dustin; González, Humberto E; Juul-Pedersen, Thomas; Liu, Te; Lodeiro, Pablo Fernandez; Meire, Lorenz; Rosing, Minik T (2021): Trace Element (Fe, Co, Ni and Cu) Dynamics Across the Salinity Gradient in Arctic and Antarctic Glacier Fjords. Frontiers in Earth Science, 9, https://doi.org/10.3389/feart.2021.725279
Krisch, Stephan; Browning, Thomas J; Graeve, Martin; Ludwichowski, Kai-Uwe; Lodeiro, Pablo Fernandez; Hopwood, Mark James; Roig, Stéphane; Yong, Jaw-Chuen; Kanzow, Torsten; Achterberg, Eric Pieter (2020): The influence of Arctic Fe and Atlantic fixed N on summertime primary production in Fram Strait, North Greenland Sea. Scientific Reports, 10(1), 15230, https://doi.org/10.1038/s41598-020-72100-9
Krisch, Stephan; Hopwood, Mark James; Schaffer, Janin; Al Hashem,, A; Höfer, Juan; Rutgers van der Loeff, Michiel M; Conway, Tim M; Summers, Brent A; Lodeiro, Pablo Fernandez; Ardiningsih, Indah; Steffens, Tim; Achterberg, Eric Pieter (2021): The 79°N Glacier cavity modulates subglacial iron export to the NE Greenland Shelf. Nature Communications, 12(1), 3030, https://doi.org/10.1038/s41467-021-23093-0
Coverage:
Median Latitude: 79.115283 * Median Longitude: -5.653493 * South-bound Latitude: 76.801500 * West-bound Longitude: -19.518000 * North-bound Latitude: 80.853170 * East-bound Longitude: 9.277000
Date/Time Start: 2016-07-21T09:36:00 * Date/Time End: 2016-09-01T17:17:00
Minimum DEPTH, water: 4.8 m * Maximum DEPTH, water: 3121.1 m
Event(s):
PS100/013-1 * Latitude: 77.499000 * Longitude: 9.277000 * Date/Time: 2016-07-21T09:36:00 * Elevation: -1964.6 m * Location: North Greenland Sea * Campaign: PS100 (ARK-XXX/2, GN05) * Basis: Polarstern * Method/Device: CTD/Rosette, ultra clean (CTD-UC)
PS100/015-1 * Latitude: 79.001170 * Longitude: 8.328330 * Date/Time: 2016-07-22T19:15:00 * Elevation: -793.2 m * Location: North Greenland Sea * Campaign: PS100 (ARK-XXX/2, GN05) * Basis: Polarstern * Method/Device: CTD/Rosette, ultra clean (CTD-UC)
PS100/021-1 * Latitude: 79.000330 * Longitude: 7.498330 * Date/Time: 2016-07-24T00:25:00 * Elevation: -1223.9 m * Location: North Greenland Sea * Campaign: PS100 (ARK-XXX/2, GN05) * Basis: Polarstern * Method/Device: CTD/Rosette, ultra clean (CTD-UC)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Cruise/expeditionExpeditionKrisch, Stephan
2Event labelEventKrisch, Stephan
3Station labelStationKrisch, Stephan
4Longitude of eventLongitudeKrisch, Stephan
5Latitude of eventLatitudeKrisch, Stephan
6Date/Time of eventDate/TimeKrisch, Stephan
7Elevation of eventElevationmKrisch, Stephan
8DEPTH, waterDepth watermKrisch, StephanGeocode
9Bottle numberBottleKrisch, Stephan
10Manganese, dissolvedMn dissnmol/lKrisch, StephanInductively coupled plasma - mass spectrometry (ICP-MS)
11Manganese, dissolved, standard deviationMn diss std dev±Krisch, Stephancalculated, 1 sigma
12Standard deviation, relativeStd dev r%Krisch, StephanManganese, dissolved
13Quality flagQFKrisch, StephanSeadatanet flag: Data quality control procedures according to SeaDataNet (2010)Manganese, dissolved
14Iron, dissolvedFe dissnmol/lKrisch, StephanInductively coupled plasma - mass spectrometry (ICP-MS)
15Iron, dissolved, standard deviationFe diss std dev±Krisch, Stephancalculated, 1 sigma
16Standard deviation, relativeStd dev r%Krisch, StephanIron, dissolved
17Quality flagQFKrisch, StephanSeadatanet flag: Data quality control procedures according to SeaDataNet (2010)Iron, dissolved
18Cobalt, dissolvedCo dissnmol/lKrisch, StephanInductively coupled plasma - mass spectrometry (ICP-MS)
19Cobalt, dissolved, standard deviationCo diss std dev±Krisch, Stephancalculated, 1 sigma
20Standard deviation, relativeStd dev r%Krisch, StephanCobalt, dissolved
21Quality flagQFKrisch, StephanSeadatanet flag: Data quality control procedures according to SeaDataNet (2010)Cobalt, dissolved
22Nickel, dissolvedNi dissnmol/lKrisch, StephanInductively coupled plasma - mass spectrometry (ICP-MS)
23Nickel, dissolved, standard deviationNi diss std dev±Krisch, Stephancalculated, 1 sigma
24Standard deviation, relativeStd dev r%Krisch, StephanNickel, dissolved
25Quality flagQFKrisch, StephanSeadatanet flag: Data quality control procedures according to SeaDataNet (2010)Nickel, dissolved
26Copper, dissolvedCu dissnmol/lKrisch, StephanInductively coupled plasma - mass spectrometry (ICP-MS)
27Copper, dissolved, standard deviationCu diss std dev±Krisch, Stephancalculated, 1 sigma
28Standard deviation, relativeStd dev r%Krisch, StephanCopper, dissolved
29Quality flagQFKrisch, StephanSeadatanet flag: Data quality control procedures according to SeaDataNet (2010)Copper, dissolved
30Zinc, dissolvedZn dissnmol/lKrisch, StephanInductively coupled plasma - mass spectrometry (ICP-MS)
31Zinc, dissolved, standard deviationZn diss std dev±Krisch, Stephancalculated, 1 sigma
32Standard deviation, relativeStd dev r%Krisch, StephanZinc, dissolved
33Quality flagQFKrisch, StephanSeadatanet flag: Data quality control procedures according to SeaDataNet (2010)Zinc, dissolved
34Lead, dissolvedPb disspmol/lKrisch, StephanInductively coupled plasma - mass spectrometry (ICP-MS)
35Lead, standard deviationPb std dev±Krisch, Stephancalculated, 1 sigma
36Standard deviation, relativeStd dev r%Krisch, StephanLead, dissolved
37Quality flagQFKrisch, StephanSeadatanet flag: Data quality control procedures according to SeaDataNet (2010)Lead, dissolved
38Cadmium, dissolvedCd dissnmol/lKrisch, StephanInductively coupled plasma - mass spectrometry (ICP-MS)
39Cadmium, dissolved, standard deviationCd diss std dev±Krisch, Stephancalculated, 1 sigma
40Standard deviation, relativeStd dev r%Krisch, StephanCadmium, dissolved
41Quality flagQFKrisch, StephanSeadatanet flag: Data quality control procedures according to SeaDataNet (2010)Cadmium, dissolved
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
16511 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)