Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Wegener, Gunter; van Erk, Marit R; Teske, Andreas P (2021): Concentrations of dissolved anions in porewater and gaseous alkanes in sediments retrieved from the Guaymas Basin hydrothermal sediments in 2018 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.931866

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
The Guaymas Basin hydrothermal vents in the Gulf of California (Mexico) were visited with the research vessel RV Atlantis in November to December 2018 (mission AT 42-05). Due to its proximity to land, this area is covered with thick organic-rich sediments. In the subsurface heated fluids enrich in hydrocarbons gases, leading to complex biogeochemical reactions in surface sediments (Teske et al., 2016; doi:10.3389/fmicb.2016.00075). We used the submarine ALVIN to collect sediments with push cores at sites covered with different mat types and surrounding areas. Aim of this effort was to describe the biogeochemistry and the fluxes of dissolved species in these sediments. We collected porewater from these push cores using Rhizon technology (Seeberg-Elverfeldt et al., 2005; doi:10.4319/lom.2005.3.361). Porewater sampling was performed in anoxic tents to preserve oxygen-sensitive dissolved metal species. Samples were preserved according to established protocols. In the home laboratory we measured concentrations of dissolved inorganic carbon, chloride, sulfate, sulfide, dissolved inorganic carbon, nitrate, nitrite, ammonium, phosphate and silicate and concentrations of dissolved iron using two approaches and manganese were assessed. Sediment cores is the direct vicinity of these cores were taken as replicates for the measurement of dissolved gases. Cores were sectioned and 2 ml sediments were sampled into glass-vials filled with 5 ml sodium hydroxide solutions and were sealed gas-tight. Concentrations of the hydrocarbon gases methane, ethane, propane, i-butane and butane were measured using gas chromatography coupled to flame ionization detection.
Keyword(s):
butane; Ethane; hydrothermal vent; Methane; porewater; propane; sediment
Coverage:
Median Latitude: 27.010814 * Median Longitude: -111.404795 * South-bound Latitude: 27.006900 * West-bound Longitude: -111.409000 * North-bound Latitude: 27.012200 * East-bound Longitude: -111.403800
Date/Time Start: 2018-11-17T21:40:00 * Date/Time End: 2018-11-25T20:12:00
Minimum DEPTH, sediment/rock: 0.005 m * Maximum DEPTH, sediment/rock: 0.240 m
Event(s):
AT42-05_4991-13 (orange mat) * Latitude: 27.011400 * Longitude: -111.404500 * Date/Time: 2018-11-17T21:40:00 * Elevation: -2014.0 m * Location: Guaymas Basin * Campaign: AT42-05 (Guaymas Basin) * Basis: Atlantis (1997) * Method/Device: Push corer (PUC) * Comment: Southern Axial Valley; Cathedral Hill; Replicate to other measurement: porewater geochemistry
AT42-05_4991-14 (orange mat) * Latitude: 27.011400 * Longitude: -111.404500 * Date/Time: 2018-11-17T21:40:00 * Elevation: -2014.0 m * Location: Guaymas Basin * Campaign: AT42-05 (Guaymas Basin) * Basis: Atlantis (1997) * Method/Device: Push corer (PUC) * Comment: Southern Axial Valley; Cathedral Hill; Replicate to other measurement: Hydrocarbon gases; replicate to 4991-13
AT42-05_4991-17 (orange mat) * Latitude: 27.011400 * Longitude: -111.404500 * Date/Time: 2018-11-17T21:40:00 * Elevation: -2014.0 m * Location: Guaymas Basin * Campaign: AT42-05 (Guaymas Basin) * Basis: Atlantis (1997) * Method/Device: Push corer (PUC) * Comment: Southern Axial Valley; Cathedral Hill; Replicate to other measurement: porewater geochemistry
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventTeske, Andreas P
2Station labelStationWegener, Gunter
3Sample IDSample IDWegener, Gunter
4Latitude of eventLatitudeTeske, Andreas P
5Longitude of eventLongitudeTeske, Andreas P
6Date/Time of eventDate/TimeTeske, Andreas P
7Elevation of eventElevationmTeske, Andreas P
8DEPTH, sediment/rockDepth sedmWegener, GunterRuler stick (RULER)Geocode
9Carbon, inorganic, dissolvedDICmmol/lWegener, GunterFlow injection analysis (Hall and Aller 1992)
10Sulfate[SO4]2-mmol/lWegener, GunterIon chromatography (Metrohm 930 Compact IC)
11Sulfide, totalTS2-mmol/lWegener, GunterSpectrophotometry
12ChlorideCl-mmol/lWegener, GunterIon chromatography (Metrohm 930 Compact IC)
13AmmoniaNH3µmol/lWegener, GunterContinuous Segmented Flow Analyzer, SEAL Analytical, QuAAtro39
14Phosphate[PO4]3-µmol/lWegener, GunterContinuous Segmented Flow Analyzer, SEAL Analytical, QuAAtro39
15SilicateSi(OH)4µmol/lWegener, GunterContinuous Segmented Flow Analyzer, SEAL Analytical, QuAAtro39
16Iron 2+Fe2+µmol/lWegener, GunterAtomic absorption spectrometry (AAS) (Thermo iCE3000)dissolved; From porewater fixed with HCl (200µl 1M + 1 ml Sample)
17ManganeseMnµmol/lWegener, GunterAtomic absorption spectrometry (AAS) (Thermo iCE3000)dissolved; From porewater fixed with HCl (200µl 1M + 1 ml Sample)
18Iron 2+Fe2+µmol/lvan Erk, Marit RSpectrophotometryFerronize method
19MethaneCH4mmol/lWegener, GunterGas chromatography - Flame Ionization Detection (GC-FID)
20EthaneC2H6mmol/lWegener, GunterGas chromatography - Flame Ionization Detection (GC-FID)
21PropaneC3H8mmol/lWegener, GunterGas chromatography - Flame Ionization Detection (GC-FID)
22Isobutanei-C4H10mmol/lWegener, GunterGas chromatography - Flame Ionization Detection (GC-FID)
23n-Butanen-C4H10mmol/lWegener, GunterGas chromatography - Flame Ionization Detection (GC-FID)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1238 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML